936 resultados para Polymer liquid crystal
Resumo:
A generic LC-MS approach for the absolute quantification of undigested peptides in plasma at mid-picomolar levels is described. Nine human peptides namely, brain natriuretic peptide (BNP), substance P (SubP), parathyroid hormone 1-34 (PTH), C-peptide, orexines A and B (Orex-A and -B), oxytocin (Oxy), gonadoliberin-1 (gonadothropin releasing-hormone or luteinizing hormone-releasing hormone, LHRH) and α-melanotropin (α-MSH) were targeted. Plasma samples were extracted via a 2-step procedure: protein precipitation using 1vol of acetonitrile followed by ultrafiltration of supernatants on membranes with a MW cut-off of 30 kDa. By applying a specific LC-MS setup, large volumes of filtrates (e.g., 2×750 μL) were injected and the peptides were trapped on a 1mm i.d.×10 mm length C8 column using a 10× on-line dilution. Then, the peptides were back-flushed and a second on-line dilution (2×) was applied during the transfer step. The refocalized peptides were resolved on a 0.3mm i.d. C18 analytical column. Extraction recovery, matrix effect and limits of detection were evaluated. Our comprehensive protocol demonstrates a simple and efficient sample preparation procedure followed by the analysis of peptides with limits of detection in the mid-picomolar range. This generic approach can be applied for the determination of most therapeutic peptides and possibly for endogenous peptides with latest state-of-the-art instruments.
Resumo:
A selective and sensitive method was developed for the simultaneous quantification of seven typical antipsychotic drugs (cis-chlorprothixene, flupentixol, haloperidol, levomepromazine, pipamperone, promazine and zuclopenthixol) in human plasma. Ultra-high performance liquid chromatography (UHPLC) was used for complete separation of the compounds in less than 4.5min on an Acquity UPLC BEH C18 column (2.1mm×50mm; 1.7μm), with a gradient elution of ammonium formate buffer pH 4.0 and acetonitrile at a flow rate of 400μl/min. Detection was performed on a tandem quadrupole mass spectrometer (MS/MS) equipped with an electrospray ionization interface. A simple protein precipitation procedure with acetonitrile was used for sample preparation. Thanks to the use of stable isotope-labeled internal standards for all analytes, internal standard-normalized matrix effects were in the range of 92-108%. The method was fully validated to cover large concentration ranges of 0.2-90ng/ml for haloperidol, 0.5-90ng/ml for flupentixol, 1-450ng/ml for levomepromazine, promazine and zuclopenthixol and 2-900ng/ml for cis-chlorprothixene and pipamperone. Trueness (89.1-114.8%), repeatability (1.8-9.9%), intermediate precision (1.9-16.3%) and accuracy profiles (<30%) were in accordance with the latest international recommendations. The method was successfully used in our laboratory for routine quantification of more than 500 patient plasma samples for therapeutic drug monitoring. To the best of our knowledge, this is the first UHPLC-MS/MS method for the quantification of the studied drugs with a sample preparation based on protein precipitation.
Resumo:
Kinetics of crystal growth and equilibrium domains in eclogite of the Sesia Zone, Western Alps Darbellay Bastien Institut de Minéralogie et Géochimie Résumé grand public Comme toute matière, la roche est sensible à son environnement et cherche à s'adapter pour acquérir un état stable (état d'équilibre). Les changements des conditions physiques (température et pression) vont ainsi impliquer des modifications dans la roche. Le métamorphisme est l'étude de ces changements. Les minéraux qui constituent la roche peuvent modifier, leur structure, leur chimie ou être remplacer par d'autres minéraux plus stables. Il est ainsi crucial de déterminer les processus responsables et limitant de la croissance minérale. Trois processus permettent la croissance ; (1) la dissolution des éléments du réactant, (2) le transport de ces éléments vers le site de croissance, (3) l'incorporation de ces éléments dans la nouvelle structure. Cette thèse se focalise sur les structures des minéraux de haute pression (forme, zonation chimique, structure interne) pour essayer de déterminer les facteurs importants à l'origine de leur état final. Les zones d'étude se situent dans la zone de Sésia. La première partie traite de la problématique liée à l'incorporation d'un élément dans une structure minérale. A l'image de la croissance humaine, les irrégularités minéralogiques permettent de mettre en lumière un dysfonctionnement de la croissance due à un excès ou à une carence d'un élément. Bien dosé, cet élément est cependant essentiel à la croissance. Les zoisites (épidotes) des métabasites de la région de Cima di Bonze montrent une zonation chimique en sablier. Dans cette zonation la teneur en fer excède la capacité maximum que peut contenir la structure orthorhombique de la zoisite. Des défauts de structure permettent l'accommodation de cet excès. La zoisite peut ainsi adapter sa structure pour permettre l'incorporation d'une relativement grande quantité de fer. Les études précédentes montraient, pour des conditions similaires, la formation de deux épidotes distinctes. La deuxième partie se penche sur la compétition entre le minéral qui fait sa croissance et les minéraux (réactants) qui l'entourent. Les métapélites de la région du Monte Mucrone contiennent des grenats atollaires. Des études détaillées de la texture et de la zonation chimique du grenat ainsi qu'une modélisation thermodynamique ont permis de mieux cerner les facteurs importants responsables de la forme atollaire. Cette structure est obtenue par un changement du comportement de la croissance du grenat le long d'un chemin P-T hercynien. Dans un premier stade, le grenat croît rapidement et consume peu le quartz de la matrice. La croissance se fait ainsi le long des jointures des grains de quartz. Dans un second temps, les changements de conditions PT donnent une croissance lente du grenat et une forte consommation du quartz. Le grenat peut ainsi développer sa forme dodécaédrale classique. La troisième partie s'intéresse aux distances de transport par diffusion d'un élément (ici l'argon) durant la haute pression. Pour ce faire, un profile d'âges 40Ar/39Ar sur biotite a été mesuré depuis un veine de haute pression riche en argon jusque dans son encaissant (granitoïd du Monte Mucrone). Le profile montre une répartition des âges suivant une courbe de diffusion. Le transport se fait sur une longueur de deux centimètre avec l'aide d'un fluide. Il est réduit à une échelle millimétrique quand la phase fluide disparaît. Cette étude montre ainsi les difficultés de transport des éléments durant la haute pression ne permettant pas un rééquilibrage de la roche à grande échelle. Kinetics of crystal growth and equilibrium domains in eclogite of the Sesia Zone, Western Alps Darbellay Bastien Institut de Minéralogie et Géochimie Résumé de thèse Les processus de croissance (diffusion des éléments et les réactions d'interface) et les conditions dans lesquelles les minéraux grandissent (température, pression, fluide, composition chimique de la roche), déterminent la texture ainsi que la zonation des minéraux. Cette thèse se focalise, par le biais de textures peu communes, sur trois différents processus impliqués dans la croissance minérale à haute pression (Zone de Sésia, Alpes de l'Ouest, Italie). L'incorporation d'un élément dans une structure minérale ne peut se faire que dans des sites en accord avec la taille et la charge ionique de l'élément. De plus, la balance de charge doit être maintenue dans le minéral. La régularité de la structure cristalline fixe ainsi une limite maximum de concentration d'un élément donné. Les zoisites provenant des métabasites de la région de Cima di Bonze montrent des zonations en sablier caractérisées par une concentration anormale en fer. La zonation se marque par une différente teinte de biréfringence et par un plus grand angle d'extinction que le reste de la zoisite. Une inter-croissance de clinozoisite à l'intérieur de la structure orthorhombique de la zoisite peut ainsi être suspectée. Les analyses XRD (diffraction des rayons x) ainsi que les analyses Raman ne confirment pas cette suspicion. Seules les analyses TEM (microscope à électrons transmis) montrent des défauts de structure pouvant être interprétés comme des modules de clinozoisite. Ils ne peuvent cependant pas être considérés comme une phase thermodynamique. Un nouveau trou d'immiscibilité entre deux zoisite (X ep= 0.1 and Xep = 0.15) a ainsi pu être établi. Dans les métapélites la région du Monte Mucrone, des grenats fortement zonés montrent une évolution texturale singulière. Ils présentent une forme initiale de `champignon' qui se développe pour former une structure atollaire finale. L'étude conjuguée de la structure 3D et des zonations, ainsi que l'établissement d'un model thermodynamique, indiquent que ces structures proviennent de deux épisodes de croissances : (1) La croissance du grenat durant un chemin prograde hercynien (de 525 °C et 6.2 kbar à 640 °C et 9 kbar) permet la formation des textures atollaires. Elles sont le résultat d'une croissance poecilitique initiale suivie d'une croissance idiomorphique du grenat. (2) La structure est rendue plus complexe par la cristallisation d'un grenat homogène tout autour ainsi qu'à l'intérieur du grenat hercynien durant la haute pression alpine (550 °C and 20 kbar). L'arrivée de l'eau durant la haute pression facilite le transport d'éléments et permet une cristallisation rapide du grenat. La diffusion peut être un facteur limitant de la croissance minéralogique. Elle a aussi une grande importance pour la géochronologie. Une veine de haute pression à l'intérieur du granitoïde du Monte Mucrone a été étudiée dans le but de déterminer la distance de diffusion de l'argon. Le profile d'âges 40Ar/39Ar sur biotites, établi de la veine vers le métagranitoïde, suit une courbe de diffusion. Les âges sont élevés proche de la veine (800 Ma) puis décroissent jusqu'à des âges homogènes (170-150 Ma) à deux centimètres de la veine. La présence de fluide, marqué par de hautes concentrations en chlore, permet une diffusion centimétrique. Cependant, la distance est réduite à une échelle millimétrique quand le fluide est absent. Les très faibles distances de diffusion préservent les âges pré-alpins et impliquent un événement géologique pour les âges de 170-150 Ma. Kinetics of crystal growth and equilibrium domains in eclogite of the Sesia Zone, Western Alps Darbellay Bastien Institut de Minéralogie et Géochimie Thesis abstract Rock textures and zonings are the consequence of growth processes (element diffusion and interface reaction) steered by the environment in which they grew (pressure, differential stress, temperature, fluid and rock composition). The thesis presented here focuses on three different topics, each of it dealing with aspects of mineral growth processes during subduction, in a high-pressure environment. All studies were conducted in the Sesia Zone of the Western European Alps, Italy. The first study addresses the crystallography and geochemistry of element incorporation in zoisite, one of the major hydrous minerals found in subduction zone rocks. Elements can be incorporated into a mineral structure only on crystallographic sites that offer enough space for the ion and the overall charge balance has to be maintained. Element concentrations are hence limited. Incorporation of some elements produces complex zoning, including hourglass like patterns, which are the focus of the first contribution. Zoisites from Cima di Bonze (Sesia Zone) show spectacular hourglass zoning defined by Fe-content variations. The hourglass zones have a distinct birefringence and a different extinction angle than the regular part of the zoisite. We show by detailed XRD (X-ray diffraction) and confocal Raman analyses that the high Fe-zones are nevertheless zoisite, and not clinozoisite as one might expect. High resolution TEM (transmission electron microscopy) analyses show planar defects on (100) that can be interpreted as small-scale clinozoisite modules. However, these clinozoisites cannot be interpreted as a distinctive thermodynamic phase and the entire mineral has to be considered as zoisite. The miscibility gap between two zoisites (Xep = 0.1 and Xep = 0.15) can be then definite at 550 ± 50°C and 14 to 20 Kbar. Strongly zoned garnets in quartz rich metapelite from the Monte Mucrone area (Sesia Zone) show evolution form 3D mushroom to atoll structure. The second contribution presents textural investigations, garnet zoning and thermodynamic modeling that demonstrate that atoll garnets are the result of two distinctive growth events. (1) Garnet atoll structure is already formed during a prograde Hercynian path from 525 °C and 6.2 kbar to 640 °C and 9 kbar. It results in an initial poikilitic growth followed by a final idiomorphic growth event. (2) Alpine HP garnet are homogenous (550 °C and 20 kbar) and grew around and also inside the Hercynian garnet. Lack of prograde Alpine garnet and fast growth of the HP garnet is explained by the absence of water during much of the prograde path. Water saturation was only observed towards the end, close towards the peak metamorphic conditions. Diffusion could be a limiting factor for crystal growth. It has also a great importance in geochronology. HP vein inside the metagranitoide of the Monte Mucrone (~300 Ma) was investigated to determine argon diffusion scales during high-pressure metamorphism. 40Ar/39Ar biotite ages profile from the vein toward the metagranodiorite show a diffusion curve: old ages (800 Ma) located close to the vein decrease until homogenous 170-150 Ma ages are obtained, two centimeter away from the vein. Centimeter-scale diffusion occurs with help of a fluid phase marked by high chlorine concentrations. Argon diffusion is reduced to a millimeter scale when free fluid is absent. Very short diffusion distance permits to preserve pre-Alpine ages. The 170-150 Ma ages are considered to be geologic meaningful, probably resulting from the extensional tectonics linked to opening of the Tethian ocean.
Resumo:
Fiber reinforced polymer (FRP) composite materials are making an entry into the construction market in both buildings and pavements. The application to pavements so far has come in the form of joint reinforcement (dowels and tie bars). FRP resistance to salt corrosion in dowels has made it an alternative to standard epoxy-coated steel dowels for pavements. Iowa State University has completed a large amount of laboratory research to determine the diameter, spacing, and durability of FRP dowels. This report documents the performance of elliptical FRP dowels installed in a field situation. Ten joints were monitored in three consecutive test sections, for each of three dowel spacings (10, 12, and 15 inches) including one instrumented dowel in each test section. The modulus of dowel bar support was determined using falling weight deflectometer (FWD) testing and a loaded crawl truck. FWD testing was also used to determine load transfer efficiency across the joint. The long-term performance and durability of the concrete was also evaluated by monitoring faulting and joint opening measurements and performing visual distress surveys at each joint. This report also contains similar information for standard round, medium elliptical, and heavy elliptical steel dowels in a portion of the same highway. In addition, this report provides a summary of theoretical analysis used to evaluate joint differential deflection for the dowels.
Resumo:
Huntington's disease (HD) is a monogenic neurodegenerative disease that affects the efferent neurons of the striatum. The protracted evolution of the pathology over 15 to 20 years, after clinical onset in adulthood, underscores the potential of therapeutic tools that would aim at protecting striatal neurons. Proteins with neuroprotective effects in the adult brain have been identified, among them ciliary neurotrophic factor (CNTF), which protected striatal neurons in animal models of HD. Accordingly, we have carried out a phase I study evaluating the safety of intracerebral administration of this protein in subjects with HD, using a device formed by a semipermeable membrane encapsulating a BHK cell line engineered to synthesize CNTF. Six subjects with stage 1 or 2 HD had one capsule implanted into the right lateral ventricle; the capsule was retrieved and exchanged for a new one every 6 months, over a total period of 2 years. No sign of CNTF-induced toxicity was observed; however, depression occurred in three subjects after removal of the last capsule, which may have correlated with the lack of any future therapeutic option. All retrieved capsules were intact but contained variable numbers of surviving cells, and CNTF release was low in 13 of 24 cases. Improvements in electrophysiological results were observed, and were correlated with capsules releasing the largest amount of CNTF. This phase I study shows the safety, feasibility, and tolerability of this gene therapy procedure. Heterogeneous cell survival, however, stresses the need for improving the technique.
Resumo:
Fiber composite materials (FRP) are making an entry into the construction market in both buildings and pavements. The application to pavements comes in the form of joint reinforcement (dowels and tie bars) to date. FRP resistance to salt corrosion in dowels has made it an alternative to standard epoxy coated dowels for pavements. Iowa State University has completed a large amount of laboratory research into the determination of diameter, spacing, and durability of FRP dowels. This report documents the installation of a series of FRP elliptical-shaped dowel joints (including instrumented units) in a field situation and the beginning of a two-year study to compare laboratory results to in-service pavements. Ten joints were constructed for each of three dowel spacings of 10, 12, and 15 inches ( 254, 305, and 381 mm) with one instrumented joint in each test section. The instrumented bars will be load tested with a loaded truck and FWD testing.
Resumo:
Voriconazole (VRC) is a broad-spectrum antifungal triazole with nonlinear pharmacokinetics. The utility of measurement of voriconazole blood levels for optimizing therapy is a matter of debate. Available high-performance liquid chromatography (HPLC) and bioassay methods are technically complex, time-consuming, or have a narrow analytical range. Objectives of the present study were to develop new, simple analytical methods and to assess variability of voriconazole blood levels in patients with invasive mycoses. Acetonitrile precipitation, reverse-phase separation, and UV detection were used for HPLC. A voriconazole-hypersusceptible Candida albicans mutant lacking multidrug efflux transporters (cdr1Delta/cdr1Delta, cdr2Delta/cdr2Delta, flu1Delta/flu1Delta, and mdr1Delta/mdr1Delta) and calcineurin subunit A (cnaDelta/cnaDelta) was used for bioassay. Mean intra-/interrun accuracies over the VRC concentration range from 0.25 to 16 mg/liter were 93.7% +/- 5.0%/96.5% +/- 2.4% (HPLC) and 94.9% +/- 6.1%/94.7% +/- 3.3% (bioassay). Mean intra-/interrun coefficients of variation were 5.2% +/- 1.5%/5.4% +/- 0.9% and 6.5% +/- 2.5%/4.0% +/- 1.6% for HPLC and bioassay, respectively. The coefficient of concordance between HPLC and bioassay was 0.96. Sequential measurements in 10 patients with invasive mycoses showed important inter- and intraindividual variations of estimated voriconazole area under the concentration-time curve (AUC): median, 43.9 mg x h/liter (range, 12.9 to 71.1) on the first and 27.4 mg x h/liter (range, 2.9 to 93.1) on the last day of therapy. During therapy, AUC decreased in five patients, increased in three, and remained unchanged in two. A toxic encephalopathy probably related to the increase of the VRC AUC (from 71.1 to 93.1 mg x h/liter) was observed. The VRC AUC decreased (from 12.9 to 2.9 mg x h/liter) in a patient with persistent signs of invasive aspergillosis. These preliminary observations suggest that voriconazole over- or underexposure resulting from variability of blood levels might have clinical implications. Simple HPLC and bioassay methods offer new tools for monitoring voriconazole therapy.
Resumo:
The anti-diuretic neurohypophysial hormone Vasopressin (Vp) and its synthetic analogue Desmopressin (Dp, 1-desamino-vasopressin) have received considerable attention from doping control authorities due to their impact on physiological blood parameters. Accordingly, the illicit use of Desmopressin in elite sport is sanctioned by the World Anti-Doping Agency (WADA) and the drug is classified as masking agent. Vp and Dp are small (8-9 amino acids) peptides administered orally as well as intranasally. Within the present study a method to determine Dp and Vp in urinary doping control samples by means of liquid chromatography coupled to quadrupole high resolution time-of-flight mass spectrometry was developed. After addition of Lys-Vasopressin as internal standard and efficient sample clean up with a mixed mode solid phase extraction (weak cation exchange), the samples were directly injected into the LC-MS system. The method was validated considering the parameters specificity, linearity, recovery (80-100%), accuracy, robustness, limit of detection/quantification (20/50 pg mL(-1)), precision (inter/intra-day<10%), ion suppression and stability. The analysis of administration study urine samples collected after a single intranasal or oral application of Dp yielded in detection windows for the unchanged target analyte for up to 20 h at concentrations between 50 and 600 pg mL(-1). Endogenous Vp was detected in concentrations of approximately 20-200 pg mL(-1) in spontaneous urine samples obtained from healthy volunteers. The general requirements of the developed method provide the characteristics for an easy transfer to other anti-doping laboratories and support closing another potential gap for cheating athletes.
Resumo:
Solid-phase extraction (SPE) in tandem with dispersive liquid-liquid microextraction (DLLME) has been developed for the determination of mononitrotoluenes (MNTs) in several aquatic samples using gas chromatography-flame ionization (GC-FID) detection system. In the hyphenated SPE-DLLME, initially MNTs were extracted from a large volume of aqueous samples (100 mL) into a 500-mg octadecyl silane (C(18) ) sorbent. After the elution of analytes from the sorbent with acetonitrile, the obtained solution was put under the DLLME procedure, so that the extra preconcentration factors could be achieved. The parameters influencing the extraction efficiency such as breakthrough volume, type and volume of the elution solvent (disperser solvent) and extracting solvent, as well as the salt addition, were studied and optimized. The calibration curves were linear in the range of 0.5-500 μg/L and the limit of detection for all analytes was found to be 0.2 μg/L. The relative standard deviations (for 0.75 μg/L of MNTs) without internal standard varied from 2.0 to 6.4% (n=5). The relative recoveries of the well, river and sea water samples, spiked at the concentration level of 0.75 μg/L of the analytes, were in the range of 85-118%.
Resumo:
RATIONALE The choice of containers for storage of aqueous samples between their collection, transport and water hydrogen (2H) and oxygen (18O) stable isotope analysis is a topic of concern for a wide range of fields in environmental, geological, biomedical, food, and forensic sciences. The transport and separation of water molecules during water vapor or liquid uptake by sorption or solution and the diffusive transport of water molecules through organic polymer material by permeation or pervaporation may entail an isotopic fractionation. An experiment was conducted to evaluate the extent of such fractionation. METHODS Sixteen bottle-like containers of eleven different organic polymers, including low and high density polyethylene (LDPE and HDPE), polypropylene (PP), polycarbonate (PC), polyethylene terephthalate (PET), and perfluoroalkoxy-Teflon (PFA), of different wall thickness and size were completely filled with the same mineral water and stored for 659?days under the same conditions of temperature and humidity. Particular care was exercised to keep the bottles tightly closed and prevent loss of water vapor through the seals. RESULTS Changes of up to +5 parts per thousand for d2H values and +2.0 parts per thousand for d18O values were measured for water after more than 1?year of storage within a plastic container, with the magnitude of change depending mainly on the type of organic polymer, wall thickness, and container size. The most important variations were measured for the PET and PC bottles. Waters stored in glass bottles with Polyseal (TM) cone-lined PP screw caps and thick-walled HDPE or PFA containers with linerless screw caps having an integrally molded inner sealing ring preserved their original d2H and d18O values. The carbon, hydrogen, and oxygen stable isotope compositions of the organic polymeric materials were also determined. CONCLUSIONS The results of this study clearly show that for precise and accurate measurements of the water stable isotope composition in aqueous solutions, rigorous sampling and storage procedures are needed both for laboratory standards and for unknown samples. Copyright (c) 2012 John Wiley & Sons, Ltd.
Resumo:
There is increasing evidence that the clinical efficacy of tamoxifen, the first and most widely used targeted therapy for estrogen-sensitive breast cancer, depends on the formation of the active metabolites 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen (endoxifen). Large inter-individual variability in endoxifen plasma concentrations has been observed and related both to genetic and environmental (i.e. drug-induced) factors altering CYP450s metabolizing enzymes activity. In this context, we have developed an ultra performance liquid chromatography-tandem mass spectrometry method (UPLC-MS/MS) requiring 100 μL of plasma for the quantification of tamoxifen and three of its major metabolites in breast cancer patients. Plasma is purified by a combination of protein precipitation, evaporation at room temperature under nitrogen, and reconstitution in methanol/20 mM ammonium formate 1:1 (v/v), adjusted to pH 2.9 with formic acid. Reverse-phase chromatographic separation of tamoxifen, N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen is performed within 13 min using elution with a gradient of 10 mM ammonium formate and acetonitrile, both containing 0.1% formic acid. Analytes quantification, using matrix-matched calibration samples spiked with their respective deuterated internal standards, is performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection in the positive mode. The method was validated according to FDA recommendations, including assessment of relative matrix effects variability, as well as tamoxifen and metabolites short-term stability in plasma and whole blood. The method is precise (inter-day CV%: 2.5-7.8%), accurate (-1.4 to +5.8%) and sensitive (lower limits of quantification comprised between 0.4 and 2.0 ng/mL). Application of this method to patients' samples has made possible the identification of two further metabolites, 4'-hydroxy-tamoxifen and 4'-hydroxy-N-desmethyl-tamoxifen, described for the first time in breast cancer patients. This UPLC-MS/MS assay is currently applied for monitoring plasma levels of tamoxifen and its metabolites in breast cancer patients within the frame of a clinical trial aiming to assess the impact of dose increase on tamoxifen and endoxifen exposure.
Resumo:
Introduction: Oseltamivir phosphate (OP), the prodrug of oseltamivir carboxylate (OC; active metabolite), is marketed since 10 years for the treatment of seasonal influenza flu. It has recently received renewed attention because of the threat of avian flu H5N1 in 2006-7 and the 2009-10 A/H1N1 pandemic. However, relatively few studies have been published on OP and OC clinical pharmacokinetics. The disposition of OC and the dosage adaptation of OP in specific populations, such as young children or patients undergoing extrarenal epuration, have also received poor attention. An analytical method was thus developed to assess OP and OC plasma concentrations in patients receiving OP and presenting with comorbidities or requiring intensive care. Methods: A high performance liquid chromatography coupled to tandem mass spectrometry method (HPLC-MS/MS) requiring 100-µL aliquot of plasma for quantification within 6 min of OP and OC was developed. A combination of protein precipitation with acetonitrile, followed by dilution of supernant in suitable buffered solvent was used as an extraction procedure. After reverse phase chromatographic separation, quantification was performed by electro-spray ionization-triple quadrupole mass spectrometry. Deuterated isotopic compounds of OP and OC were used as internal standards. Results: The method is sensitive (lower limit of quantification: 5 ng/mL for OP and OC), accurate (intra-/inter-assay bias for OP and OC: 8.5%/5.5% and 3.7/0.7%, respectively) and precise (intra-/inter-assay CV%: 5.2%/6.5% and 6.3%/9.2%, respectively) over the clinically relevant concentration range (upper limits of quantification 5000 ng/mL). Of importance, OP, as in other previous reports, was found not to be stable ex vivo in plasma on standard anticoagulants (i.e. EDTA, heparin or citrate). This poor stability of OP has been prevented by collecting blood samples on commercial fluoride/oxalate tubes. Conclusions: This new simple, rapid and robust HPLC-MS/MS assay for quantification of OP and OC plasma concentrations offers an efficient tool for concentration monitoring of OC. Its exposure can probably be controlled with sufficient accuracy by thorough dosage adjustment according to patient characteristics (e.g. renal clearance). The usefulness of systematic therapeutic drug monitoring in patients appears therefore questionable. However, pharmacokinetic studies are still needed to extend knowledge to particular subgroups of patients or dosage regimens.
Resumo:
Impairment of lung liquid absorption can lead to severe respiratory symptoms, such as those observed in pulmonary oedema. In the adult lung, liquid absorption is driven by cation transport through two pathways: a well-established amiloride-sensitive Na(+) channel (ENaC) and, more controversially, an amiloride-insensitive channel that may belong to the cyclic nucleotide-gated (CNG) channel family. Here, we show robust CNGA1 (but not CNGA2 or CNGA3) channel expression principally in rat alveolar type I cells; CNGA3 was expressed in ciliated airway epithelial cells. Using a rat in situ lung liquid clearance assay, CNG channel activation with 1 mM 8Br-cGMP resulted in an approximate 1.8-fold stimulation of lung liquid absorption. There was no stimulation by 8Br-cGMP when applied in the presence of either 100 μM L: -cis-diltiazem or 100 nM pseudechetoxin (PsTx), a specific inhibitor of CNGA1 channels. Channel specificity of PsTx and amiloride was confirmed by patch clamp experiments showing that CNGA1 channels in HEK 293 cells were not inhibited by 100 μM amiloride and that recombinant αβγ-ENaC were not inhibited by 100 nM PsTx. Importantly, 8Br-cGMP stimulated lung liquid absorption in situ, even in the presence of 50 μM amiloride. Furthermore, neither L: -cis-diltiazem nor PsTx affected the β(2)-adrenoceptor agonist-stimulated lung liquid absorption, but, as expected, amiloride completely ablated it. Thus, transport through alveolar CNGA1 channels, located in type I cells, underlies the amiloride-insensitive component of lung liquid reabsorption. Furthermore, our in situ data highlight the potential of CNGA1 as a novel therapeutic target for the treatment of diseases characterised by lung liquid overload.
Resumo:
UV−excimer laser photoablation was used, in combination with surface blocking techniques, to pattern proteins on the surfaces of polyimide and poly(ethylene terephthalate). This technique involves physical adsorption of avidin through laser-defined openings in low-temperature laminates or adsorbed protein blocking layers. Visualization of biomolecular patterns were monitored using avidin and fluorescein-labeled biotin as a model receptor−ligand couple. Adsorbed proteins could be shown to bind to UV-laser-treated polymer surfaces up to three times higher than on commercially available polymers. UV-laser photoablation was also used for the generation of three-dimensional structure, which leads to the possibility of biomolecule patterning within polymer-based microanalytical systems. The simplicity and easy handling of the described technique facilitate its application in microdiagnostic devices.
Resumo:
A procedure using a chirobiotic V column is presented which allows separation of the enantiomers of citalopram and its two N-demethylated metabolites, and of the internal standard, alprenolol, in human plasma. Citalopram, demethylcitalopram and didemethylcitalopram, as well as the internal standard, were recovered from plasma by liquid-liquid extraction. The limits of quantification were found to be 5 ng/ml for each enantiomer of citalopram and demethylcitalopram, and 7.5 ng/ml for each enantiomer of didemethylcitalopram. Inter- and intra-day coefficients of variation varied from 2.4% to 8.6% for S- and R-citalopram, from 2.9% to 7.4% for S- and R-demethylcitalopram, and from 5.6% to 12.4% for S- and R- didemethylcitalopram. No interference was observed from endogenous compounds following the extraction of plasma samples from 10 different patients treated with citalopram. This method allows accurate quantification for each enantiomer and is, therefore, well suited for pharmacokinetic and drug interaction investigations. The presented method replaces a previously described highly sensitive and selective high-performance liquid chromatography procedure using an acetylated 3-cyclobond column which, because of manufactural problems, is no longer usable for the separation of the enantiomers of citalopram and its demethylated metabolites.