984 resultados para Lung volume measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vision of the Internet of Things (IoT) includes large and dense deployment of interconnected smart sensing and monitoring devices. This vast deployment necessitates collection and processing of large volume of measurement data. However, collecting all the measured data from individual devices on such a scale may be impractical and time consuming. Moreover, processing these measurements requires complex algorithms to extract useful information. Thus, it becomes imperative to devise distributed information processing mechanisms that identify application-specific features in a timely manner and with a low overhead. In this article, we present a feature extraction mechanism for dense networks that takes advantage of dominance-based medium access control (MAC) protocols to (i) efficiently obtain global extrema of the sensed quantities, (ii) extract local extrema, and (iii) detect the boundaries of events, by using simple transforms that nodes employ on their local data. We extend our results for a large dense network with multiple broadcast domains (MBD). We discuss and compare two approaches for addressing the challenges with MBD and we show through extensive evaluations that our proposed distributed MBD approach is fast and efficient at retrieving the most valuable measurements, independent of the number sensor nodes in the network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: O aumento da aurícula esquerda (AE) é um marcador de mortalidade na população geral. Os doentes com miocardiopatia dilatada (MCD) têm um amplo espetro de tamanhos deAE, mas a importância clínica desta observação tem sido pouco estudada. Objectivo: Avaliar a importância prognóstica a longo prazo do volume da AE (VAE) em doentes com MCD. Métodos: Estudo prospetivo de doentes admitidos durante o ano de 2004 com o diagnóstico deMCD, em ritmo sinusal. Foi realizado estudo ecocardiográfico completo em repouso e após stress farmacológico. O endpoint composto considerou a assistência ventricular mecânica (AVM), a transplantação cardíaca ou a morte. Resultados: Foram incluídos 35 doentes (68,6% sexo masculino, idade média 52,0), 82,9% etiologia não isquémica. Fração ejeção em repouso 31,1 ± 9,4%.Durante o seguimento, oito doentes morreram, um foi colocado em AVM e um foi transplantado. A análise de Cox univariável revelou potenciais marcadores ecocardiográficos de prognóstico na amostra tais como a dimensão da AE em modo M (HR-1,12; IC: 0,99-1,26;p = 0,067); VAE (HR-1,02; IC: 1,00-1,04; p = 0,046); VAE ajustado à superfície corporal (HR-1,03;IC: 1,00-1,07; p = 0,049); E/A (HR-0,99; IC: 0,99-1,81; p = 0,060); E/A > 2 (HR-7,00; IC:1,48-32,43; p = 0,014) e E/E’ mitral (HR-1,04; IC: 1,00-1,09; p = 0,074). Na análise multivariável a única variável que permaneceu no modelo foi o VAE com o ponto de corte de 63 ml (HR-7,7, IC:0,97-60,61, p = 0,05).Conclusão: Nesta amostra, o VAE foi o único parâmetro ecocardiográfico determinante de AVM,transplantação cardíaca ou morte. Os parâmetros ecocardiográficos habitualmente utilizadospara estratificação de risco, tais como a fração ejeção do ventrículo esquerdo, a dimensão do ventrículo esquerdo e a reserva contrátil não tiveram valor prognóstico na nossa amostra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A crescente incorporação das evoluções tecnológicas nos equipamentos médicos modernos, além de os tornar mais compactos e precisos, proporciona igualmente ganhos de outros benefícios importantes, especialmente ao nível da eficiência das terapias prescritas aos pacientes. Os sofisticados ventiladores pulmonares de cuidados intensivos do presente espelham perfeitamente esta realidade e por isso necessitam de procedimentos técnicos de verificação metrológica – calibrações, também eles mais exatos e rastreáveis, de modo a fornecerem informações corretas sobre se o estado de funcionamento de um determinado ventilador cumpre ou não as tolerâncias declaradas pelo seu fabricante. Através da presente dissertação pretendeu-se desenvolver um procedimento técnico de calibração dos ventiladores de cuidados intensivos tendo-se estudado, para esta finalidade, os equipamentos de calibração específicos disponíveis no mercado, a normalização e o enquadramento regulamentar do controlo metrológico aplicáveis, bem como o princípio de funcionamento do ventilador pulmonar e a evolução da ventilação mecânica ocorrida. No domínio da abordagem efetuada sobre o âmbito da metrologia, implementou-se a determinação das incertezas dos resultados das calibrações efetuadas pelo procedimento técnico desenvolvido, de acordo com a metodologia constante do GUM1. Considerando ainda os défices significativos de conhecimento da metrologia e da prática do controlo metrológico no setor da saúde, a par dos riscos inerentes para os próprios pacientes, procura-se contribuir com este trabalho, de uma forma transversal e ampla, para uma maior consciencialização, quer dos profissionais de saúde, quer dos gestores envolvidos, para a relevância da realização das calibrações periódicas dos complexos equipamentos de suporte de vida que são os ventiladores pulmonares de cuidados intensivos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO Tratando-se a asma de uma doença respiratória, desde há várias décadas que tem sido abordada a hipótese de que factores ambientais, nomeadamente os relacionados com a qualidade do ar inalado, possam contribuir para o seu agravamento. Para além dos aeroalergenos, outros factores ambientais como a poluição atmosférica estarão associados às doenças respiratórias. O ar respirado contém uma variedade de poluentes atmosféricos, provenientes quer de fontes naturais quer de origem antropogénica, nomeadamente de actividades industriais, domésticas ou das emissões de veículos. Estes poluentes, tradicionalmente considerados como um problema de foro ambiental, têm sido cada vez mais encarados como um problema de saúde pública. Também a qualidade do ar interior, tem sido associada a queixas respiratórias, não só em termos ocupacionais mas também em exposições domésticas. Dentro dos principais poluentes, encontramos a matéria particulada (como as PM10), o O3, NO2, e os compostos orgânicos voláteis (COVs). Se é verdade que os três primeiros têm como principais fontes de exposição a combustão fóssil associada aos veículos automóveis, já os COVs (como o benzeno, tolueno, xileno, etilbenzeno e formaldeído) são poluentes mais característicos do ar interior. Os mecanismos fisiopatológicos subjacentes à agressão dos poluentes do ar não se encontram convenientemente esclarecidos. Pensa-se que após a sua inalação, induzam um grau crescente de stress oxidativo que será responsável pelo desenvolvimento da inflamação das vias aéreas. A progressão do stress oxidativo e da inflamação, associarse- ão posteriormente a lesão local (pulmonar) e sistémica. Neste trabalho pretendeu-se avaliar os efeitos da exposição individual a diversos poluentes, do ar exterior e interior, sobre as vias aéreas, recorrendo a parâmetros funcionais, inflamatórios e do estudo do stress oxidativo. Neste sentido, desenvolveu-se um estudo de painel na cidade de Viseu, em que foram acompanhadas durante 18 meses, 51 crianças com história de sibilância, identificadas pelo questionário do estudo ISAAC. As crianças foram avaliadas em quatro Visitas (quatro medidas repetidas), através de diversos exames, que incluíram execução de espirometria com broncodilatação, medição ambulatória do PEF, medição de FENO e estudo do pH no condensado brônquico do ar exalado. O estudo dos 8-isoprostanos no condensado brônquico foi efectuado somente em duas Visitas, e o do doseamento de malonaldeído urinário somente na última Visita. Para além da avaliação do grau de infestação de ácaros do pó do colchão, para cada criança foi calculado o valor de exposição individual a PM10, O3, NO2, benzeno, tolueno, xileno, etilbenzeno e formaldeído, através de uma complexa metodologia que envolveu técnicas de modelação associadas a medições directas do ar interior (na casa e escola da criança) e do ar exterior. Para a análise de dados foram utilizadas equações de estimação generalizadas com uma matriz de correlação de trabalho uniforme, com excepção do estudo das associações entre poluentes, 8-isoprostanos e malonaldeído. Verificou-se na análise multivariável a existência de uma associação entre o agravamento dos parâmetros espirométricos e a exposição aumentada a PM10, NO2, benzeno, tolueno e etilbenzeno. Foram também encontradas associações entre diminuição do pH do EBC e exposição crescente a PM10, NO2, benzeno e etilbenzeno e associações entre valores aumentados de FENO e exposição a etilbenzeno e tolueno. O benzeno, o tolueno e o etilbenzeno foram associados com maior recurso a broncodilatador nos 6 meses anteriores à Visita e o tolueno com deslocações ao serviço de urgência. Os resultados dos modelos de regressão que incluíram o efeito do poluente ajustado para o grau de infestação de ácaros do pó foram, de uma forma geral, idênticos ao da análise multivariável anterior, com excepção das associações para com o FENO. Nos modelos de exposição com dois poluentes, com o FEV1 como variável resposta, somente o benzeno persistiu com significado estatístico. No modelo com dois poluentes tendo o pH do EBC como variável resposta, somente persistiram as PM10. Os 8-isoprostanos correlacionaram-se com alguns COVs, designadamente etilbenzeno, xileno, tolueno e benzeno. Os valores de malonaldeído urinário não se correlacionaram com os valores de poluentes. Verificou-se no entanto que de uma forma geral, e em particular mais uma vez para os COVs, as crianças mais expostas a poluentes, apresentaram valores superiores de malonaldeído na urina. Verificou-se que os poluentes do ar em geral, e os COVs em particular, se associaram com uma deterioração das vias aéreas. A exposição crescente a poluentes associou-se não só com obstrução brônquica, mas também com FENO aumentado e maior acidez das vias aéreas. A exposição crescente a COVs correlacionou-se com um maior stress oxidativo das vias aéreas (medido pelos 8-isoprostanos). As crianças com exposição superior a COVs apresentaram maiores valores de malonaldeído urinário. Este trabalho sugere uma associação entre exposição a poluentes, inflamação das vias aéreas e stress oxidativo. Vem reforçar o interesse dos poluentes do ar, nomeadamente os associados a ambientes interiores, frequentemente esquecidos e que poderão ser explicativos do agravamento duma criança com sibilância.-----------ABSTRACT: Asthma is a chronic respiratory disease that could be influenced by environmental factors, as allergens and air pollutants. The air breathed contains a diversity of air pollutants, both from natural or anthropogenic sources. Atmospheric pollution, traditionally considered an environmental problem, is nowadays looked as an important public health problem. Indoor air pollutants are also related with respiratory diseases, not only in terms of occupational exposures but also in domestic activities. Particulate matter (such as PM10), O3, NO2 and volatile organic compounds (VOCs) are the main air pollutants. The main source for PM10, O3, NO2 exposure is traffic exhaust while for VOCs (such as benzene, toluene, xylene, ethylbenzene and phormaldehyde) the main sources for exposure are located in indoor environments. The pathophysiologic mechanisms underlying the aggression of air pollutants are not properly understood. It is thought that after inhalation, air pollutants could induce oxidative stress, which would be responsible for airways inflammation. The progression of oxidative stress and airways inflammation, would contribute for the local and systemic effects of the air pollutants. The present study aimed to evaluate the effects of individual exposure to various pollutants over the airways, through lung function tests, inflammatory and oxidative stress biomarkers. In this sense, we developed a panel study in the city of Viseu, that included 51 children with a history of wheezing. Those children that were identified by the ISAAC questionnaire, were followed for 18 months. Children were assessed four times (four repeated measures) through the following tests: spirometry with bronchodilation test, PEF study, FENO evaluation and exhaled breath condensate pH measurement. 8-isoprostane in the exhaled breath condensate were also measured but only in two visits. Urinary malonaldehyde measurement was performed only in the last visit. Besides the assessment of the house dust mite infestation, we calculated for each child the value of individual exposure to a wide range of pollutants: PM10, O3, NO2, benzene, toluene, xylene, ethyl benzene and formaldehyde. This strategy used a complex methodology that included air pollution modelling techniques and direct measurements indoors (homes and schools) and outdoors. Generalized estimating equations with an exchangeable working correlation matrix were used for the analysis of the data. Exceptions were for the study of associations between air pollutants, malonaldehyde and 8-isoprostanes. In the multivariate analysis we found an association between worsening of spirometric outcomes and increased exposure to PM10, NO2, benzene, toluene and ethylbenzene. In the multivariate analysis we found also negative associations between EBC pH and exposure to PM10, NO2, benzene, ethylbenzene and positive associations between FENO and exposure to ethylbenzene and toluene. Benzene, toluene and ethylbenzene were associated with increased use of bronchodilator in the 6 months prior to the visit and toluene with emergency department visits. Results of the regression models that included also the effect of the pollutant adjusted for the degree of infestation to house dust mites, were identical to the previous models. Exceptions were for FENO associations. In the two-pollutant models, with the FEV1 as dependent variable, only benzene persisted with statistical significance. In the two pollutant model with pH of EBC as dependent variable, only PM10 persisted. 8-isoprostanes were well correlated with some VOCs, namely with ethylbenzene, xylene, toluene and benzene. Urinary malonaldehyde did not present any correlation with air pollutants exposure. However, those children more exposed to air pollutants (namely to VOCs), presented higher values of malonaldehyde. It was found that air pollutants in general, and namely VOCs, were associated with deterioration of the airways. The increased exposure to air pollutants was associated not only with airways obstruction, but also with increased FENO and higher acidity of the airways. The increased exposure to VOCs was correlated with increased airways oxidative stress (measured by 8-isoprostane). Children with higher levels of exposure to VOCs had higher values of urinary malonaldehyde. This study suggests a relation between air pollution, airways inflammation and oxidative stress. It suggests also that attention should be dedicated to air quality as air pollutants could cause airways deterioration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Budesonide (800 mg bid, for 2 months) was administered to 12 asthmatic children (mean age, 11.293.3 years) with lung hyperinflation (TGV]130% predicted and:or RV]140% predicted) in a randomised, placebo controlled, double blind, crossover study. Body plethysmography (panting frequency controlled at 1·s 1) was performed at the beginning, 2 months afterwards (before crossover) and at the end of the study. Budesonide significantly reduced TGV (2.3590.90 l BTPS or 126924% predicted) compared with placebo (2.5491.08 l BTPS, P 0.014 or 140921% predicted, PB0.05). In addition, budesonide significantly increased mean specific conductance (0.0690.02 cm H2O 1 l s 1 to 0.0790.01 cm H2O 1 l s 1, PB0.05). It was concluded that budesonide reduced lung hyperinflation most likely by decreasing airway inflammation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do Grau de Mestre em Engenharia Biomédica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO - Objetivos: Estudos anteriores demonstraram a existência de uma relação inversa entre melhores outcomes e volume hospitalar. Tendo este fenómeno em consideração, o objetivo deste estudo foi analisar esta relação a um nível populacional em Portugal. Métodos: Análise da base de dados Portuguesa dos GDH relativos ao ano financeiro de 2009. Todas as STA e STJ foram contabilizadas e critérios de exclusão determinados, para selecionar duas amostras homogéneas, analisadas por volume hospitalar. O volume hospitalar foi definido em três grupos: HVB, HVM, HVE de acordo com o volume anual de procedimentos efetuado por cada hospital individual durante o período do estudo. Os outcomes avaliados incluíram a mortalidade, presença de pelo menos uma complicação cirúrgica, estadia prolongada assim como a média de dias de internamento. A idade e sexo foram controlados como possíveis fatores de confundimento. Resultados: A investigação principal consistiu na análise de 4615 STA e 5904 STJ. Os resultados indicam que os eventos adversos (mortalidade e complicações cirúrgicas) são pouco comuns nestes procedimentos, produzindo resultados sem significância estatística. A estadia prolongada estabeleceu uma clara e significativa relação inversa com o volume hospitalar. A estadia prolongada foi superior em hospitais de volume baixo (STA OR 2.71; STJ OR 2.17) e hospitais de volume médio (STA OR 1.72; STJ OR 1.73) quando comparados com hospitais de volume elevado. Os dias de internamento médios produziram uma associação semelhante, sendo possível estimar quase oito milhões e meio de euros de custos evitáveis no ano de 2009, em ambos os procedimentos. Conclusões: O volume hospitalar não apresentou relações significativas com a mortalidade e complicações cirúrgicas, devido ao baixo número de eventos adversos registados. Verificou-se, no entanto, uma associação significativa com os dias de internamento e estadia prolongada. As STA e STJ realizadas em hospitais de volume elevado poderão reduzir custos, ao diminuir os dias de internamento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Mestrado Integrado em Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation to obtain a Master degree in Biotechnology

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A medida dos diâmetros longitudinal e transverso de uma lesão ulcerada na leishmaniose tegumentar não reflete a profundidade, a qual também tem importância na avaliação da cura. A proposta deste estudo foi avaliar o volume da úlcera leishmaniõtica, através da moldagem seriada, antes e após o tratamento. A moldagem da cavidade, apôs assepsia local com água e sabão, foi feita com material plástico gelatinoso ã base de sílica, alginato de potássio, sulfato de cálcio e óxido de magnésio, comercializado sob o nome de jeltrate® (Dentsply Laboratory). Dissolveu-se 9,5g de jeltrate® em 20ml de água e aplicou-se o gel sobre a úlcera, o qual se solidificou em cinco minutos. Este molde foi então preenchido com acrílico autopolimerizante e o seu volume mensurado através do peso, usando-se balança analítica (Técnica 1) ou através do deslocamento da água, aplicando o princípio de Arquimedes (Técnica 2). Mostramos os dados de um estudo i-ealizado numa área de transmissão de Leishmania (Viannia) braziliensis onde 20 pacientes foram tratados com três diferentes esquemas: sete pacientes receberam isotianato depentamidina, sete receberam sulfato de aminosidine e seis antimoniato de meglumina. Os resultados mostram em todos os pacientes redução uniforme do volume das úlceras melhor avaliada por qualquer uvta das duas técnicas utilizadas. Em relação aos esquemas terapêuticos houve diferença estatística significante entre os três esquemas usando o teste T de student, o qual mostrou que o sulfato de aminosidine produziu maior redução de volume que os outros compostos. Moldagens seriadas são registros permanentes e refletem melhor a cura clínica. Concluímos que a medida da lesão ulcerada é útil na avaliação terapêutica como procedimento prático, barato e que pode ser utilizado em estudos de campo.