913 resultados para Keyed One-Way Functions
Resumo:
The goal of the present study was to investigate possible differences towards strenght recovery measured by different methods and running economy (RE), after one session of downhill running (DR), in order to induce muscle damage (MD). Our hypothesis is that the strenght recovery measured by jumps is more alike RE markers, due to the measures' specificity. Ten male subjects, ages 18 to 30, apparently healthy, without any experience with strenght training at least 6 months before the tests took place in this study. After going to the lab twice (to familiarize themselves with the protocols, and determine their maximum oxygen consumption/running speeds), they went to the lab five times in the following week, in order to collect all the variables before, immediately after, and 24, 48, 72 and 96 hours in. The variables obtained were: stride frequency (SF), stride lenght (SL), oxygen volume (VO2), carbon dioxide volume (VCO2), ventilation (VE), lactate blood concentration ([Lac]), isometric peak torque (IPT), subjective pain perception (SPP), effort perception (EP), medial-portion circumference (CIR), knee movement extent (EXT), torque development rate (TDR), counter movement jump and squat jump height (HCM and HS), strenght development rate of both jumps (SDCM and SDS), and maximum soil strenght reaction (SRCM and SRS). Changes over time in all variables were verified by one way variancy analysis. Differences between the strenght measures were verified by two way variancy analysis. When significant effects were verified, Tuckey's post-hoc were applied. The significancy level taken on this study was p < 0,05. Of all indirect muscle damage markers, IPT, SPP and TDR were the only ones in which ocurred significant changes. We couldn't find the moments where this happened for TDR with the post-hoc used. On RE markers, VO2, [Lac] and VE suffered significant effects over time. About the jumps variables, only SDCM and HCM presented significant...
Resumo:
Among the numerous possibilities of physical exercise, it has been recommended that stretching routines should be incorporated into training programs focused on the elderly population, and that these routines should be preferentially performed on the same strength or aerobic training session. However, studies have shown that muscle strength production can be acutely impaired if it is preceded by static stretching exercises (AE). Although there seems to be a relationship between the number of stretched muscles and strength response, no studies were found examining such relationship in the same study, simultaneously. Thus, the objective of this study is to analyze the acute effect of stretching of different muscle groups on strength performance in older women. Nineteen physically active older women participated in the study (67.8 ± 5.3 years, 68.9 ± 12.4 kg, 157.2 ± 6.4 cm)-usar ponto final em inglês e não vírgula. The participants visited the lab for six consecutive days, three of which were intended to familiarization. Over the next three days, all the participants performed the experimental conditions: control; quadriceps stretching alone and complete stretching, involving the major extensors muscle groups of knees and hips. Both the two stretching conditions were realized with three series of 30s (total volume of 90 seconds for each exercise). All experimental conditions was be performed with an interval of at least 24 hours and order of execution was be randomized. The force transducer was connected to a leg press apparatus, where the isometric force time curve and electromyographic activity of the vastus medial and vastus lateralis were recorded. Measurements were registered immediately after each experimental condition, during five seconds. Statistical analysis comprised descriptive procedures and the One way ANOVA test for repeated measures (p<0.05). No statistically significant differences between the control and the two...
Resumo:
Several methods are used towards delayed onset muscle soreness appraisal. This study's goal was to investigate, amongst three commonly adopted methods, which one would be the most effective (the one that shows higher values) in the quantification of this phenomenon. 10 male subjects, of age 22.8 ± 3.1 years old, weight 80 ± 12.4 kg, height 174 ± 0.07 cm, without recent experience with strength training (lower limbs) and/or running took place in this study. All subjects carried out a muscle damage induction protocol, which consisted of 30 minute downhill running (-16% or -9.09º) at 80% speed compared to their maximum oxygen consumption. Muscle damage determinants such as isometric peak torque, knee joint range of motion and circumference of the medial portion of the thight were measured before, during, 24, 48, 72 and 96 hours after downhill running. The subjective pain perception was measured simultaneously with the other determinants through three different tests: sitting on and getting up of a chair; climbing and descending from a 45cm step; and self thigh palpation. After going through all subjective pain perception tests, the subjects filled out a visual analog scale with their perception of pain. Muscle damage changes over time were compared through variance analysis (ANOVA) one way for repeated measures. Subjective pain perception values obtained in all three different tests were compared through two way ANOVAs for repeated numbers. The significance level adopted in this study was z ≤ 0.05. The results showed that the step test was the on which better evaluated the delayed onset muscle soreness. No significant differences were found through the ADM and CIR recovery markers. Downhil running determined reduced of PTI (~22.4%). Significant links between pain were obtained for both subjective pain perception tests starting at 24 and 48 hours, where the highest registered average happened in the step test after 48h, with high...
Resumo:
Recent bonding systems have been advocated as multi-purpose bonding agents. The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to evaluate the radiopacity of two conventional cements (Zinc Cement and Ketac Cem Easymix), one resin-modified glass ionomer cement (RelyX Luting 2) and six resin cements (Multilink, Bistite II DC, RelyX ARC, Fill Magic Dual Cement, Enforce and Panavia F) by digitization of images. Methods. Five disc-shaped specimens (10×1.0 mm) were made for each material, according to ISO 4049. After setting of the cements, radiographs were made using occlusal films and a graduated aluminum stepwedge varying from 1.0 to 16 mm in thickness. The radiographs were digitized, and the radiopacity of the cements was compared with the aluminum stepwedge using the software VIXWIN-2000. Data (mmAl) were submitted to one-way ANOVA and Tukey's test (=0.05). Results. The Zinc Cement was the most radiopaque material tested (<0.05). The resin cements presented higher radiopacity (<0.05) than the conventional (Ketac Cem Easymix) or resin-modified glass ionomer (RelyX Luting 2) cements, except for the Fill Magic Dual Cement and Enforce. The Multilink presented the highest radiopacity (<0.05) among the resin cements. Conclusion. The glass ionomer-based cements (Ketac Cem Easymix and RelyX Luting 2) and the resin cements (Fill Magic Dual Cement and Enforce) showed lower radiopacity values than the minimum recommended by the ISO standard.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Purpose: In order to assist in the selection of artificial teeth for complete dentures, this study aimed to assess the relationship between horizontal and vertical measurements of the face and the morphology of the maxillary central incisor. Materials and Methods: This was a study of 50 plaster casts and 100 teleradiographs - 50 in lateral norm and 50 in frontal norm, belonging to 50 individuals, Caucasian, with a naturally optimal occlusion, matching at least four of the six keys of Andrews. Images of the upper central incisors were obtained by scanning the plaster casts (three-dimensional) and subjectively classified by three examiners as oval, triangular or quadrangular. Facial measures (vertical and horizontal) were defined by means of teleradiographs. In order to check inter-examiner agreement on the classification of central incisor, the Kappa test was used. To verify whether data had normal distribution, the Kolmogorov-Smirnov test was used ( P > 0.2) was used. One-way analysis of variance was employed to assess the association between variables (P > 0.05). Results: When vertical measurements were compared with the three incisor shapes, there was no statistically significant difference (P > 0.05): Triangular (0.54), oval (0.63) and quadrangular (0.51). Similarly, no difference (P > 0.05) was found for facial width (139.08, 143.37, 141.65), maxillary width (76.68, 78.99, 76.91) and mandibular width (103.47, 105.50, 103.11). Conclusions: The majority of cases showed that horizontal and vertical measurements of the face cannot be used as a reference for determining the morphology of the maxillary central incisor crown. It is relevant to analyze and compare other morphological structures to improve the oral health-related quality of life for the conventional denture wearer.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Desenvolvimento Humano e Tecnologias - IBRC