916 resultados para Hours of Labor
Resumo:
BACKGROUND AND PURPOSE Mechanical thrombectomy using stent retriever devices have been advocated to increase revascularization in intracranial vessel occlusion. We present the results of a large prospective study on the use of the Solitaire Flow Restoration in patients with acute ischemic stroke. METHODS Solitaire Flow Restoration Thrombectomy for Acute Revascularization was an international, multicenter, prospective, single-arm study of Solitaire Flow Restoration thrombectomy in patients with large vessel anterior circulation strokes treated within 8 hours of symptom onset. Strict criteria for site selection were applied. The primary end point was the revascularization rate (thrombolysis in cerebral infarction ≥2b) of the occluded vessel as determined by an independent core laboratory. The secondary end point was the rate of good functional outcome (defined as 90-day modified Rankin scale, 0-2). RESULTS A total of 202 patients were enrolled across 14 comprehensive stroke centers in Europe, Canada, and Australia. The median age was 72 years, 60% were female patients. The median National Institute of Health Stroke Scale was 17. Most proximal intracranial occlusion was the internal carotid artery in 18%, and the middle cerebral artery in 82%. Successful revascularization was achieved in 79.2% of patients. Device and procedure-related severe adverse events were found in 7.4%. Favorable neurological outcome was found in 57.9%. The mortality rate was 6.9%. Any intracranial hemorrhagic transformation was found in 18.8% of patients, 1.5% were symptomatic. CONCLUSIONS In this single-arm study, treatment with the Solitaire Flow Restoration device in intracranial anterior circulation occlusions results in high rates of revascularization, low risk of clinically relevant procedural complications, and good clinical outcomes in combination with low mortality at 90 days. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01327989.
Resumo:
OBJECTIVE: We sought to determine maternal and neonatal outcomes by labor onset type and gestational age. STUDY DESIGN: We used electronic medical records data from 10 US institutions in the Consortium on Safe Labor on 115,528 deliveries from 2002 through 2008. Deliveries were divided by labor onset type (spontaneous, elective induction, indicated induction, unlabored cesarean). Neonatal and maternal outcomes were calculated by labor onset type and gestational age. RESULTS: Neonatal intensive care unit admissions and sepsis improved with each week of gestational age until 39 weeks (P < .001). After adjusting for complications, elective induction of labor was associated with a lower risk of ventilator use (odds ratio [OR], 0.38; 95% confidence interval [CI], 0.28-0.53), sepsis (OR, 0.36; 95% CI, 0.26-0.49), and neonatal intensive care unit admissions (OR, 0.52; 95% CI, 0.48-0.57) compared to spontaneous labor. The relative risk of hysterectomy at term was 3.21 (95% CI, 1.08-9.54) with elective induction, 1.16 (95% CI, 0.24-5.58) with indicated induction, and 6.57 (95% CI, 1.78-24.30) with cesarean without labor compared to spontaneous labor. CONCLUSION: Some neonatal outcomes improved until 39 weeks. Babies born with elective induction are associated with better neonatal outcomes compared to spontaneous labor. Elective induction may be associated with an increased hysterectomy risk.
Resumo:
When viewing web-consumer reviews consumers encounter the reviewers in an anonymous environment. Although their interactions are only virtual they still exchange social information, e.g. often reviewers refer to their proficiency or consumption motives within the review texts. Do these social information harm the viewers’ perception of the recommended products? The present study addresses this question by applying the paradigm of social comparison (Mussweiler, 2003) to web-consumer reviews. In a laboratory experiment with a student sample (n = 120) we manipulated the perceived similarity between reviewer and viewer and the perceived proficiency of the reviewer. A measurement of achievement goals (Elliott & McGregor, 2001) and average number of hours of study prior to the experiment allowed to introduce the reviewer as high [low] in proficiency and similar [dissimilar] in achievement goals. As predicted, the viewer’s evaluation of the recommended products differed as a function of this social information. Contrasting with the reviewer led to devaluing the products recommended by a proficient but dissimilar reviewer. However, against our prediction social comparison with the reviewer did not affect the viewer`s self-evaluation. Whether social information in web-product reviews affects the viewer`s self-evaluation and induces both social comparison processes remains an open question. Future studies aim to address this by manipulating the informational focus of the viewer, rather than the perceived similarity between viewer and reviewer. So far, the present study extends the application of social comparison to consumption environments and contributes to the understanding of the virtual social identity.
Resumo:
CYP4F (Cytochrome P4504F) enzymes metabolize endogenous molecules including leukotrienes, prostaglandins and arachidonic acid. The involvement of these endogenous compounds in inflammation has led to the hypothesis that changes in the inflamed tissue environment may affect the expression of CYP4Fs during the pro-inflammatory state, which in turn may modulate inflammatory conditions during the anti-inflammatory state. We demonstrated that inflamed tissues have different levels of CYP4F isoform expression profiles in a number of human samples when compared to the average population. The CYP4F isoform expression levels change with the degree of inflammation present in tissue. Further investigation in cell culture studies revealed that inflammatory cytokines, in particular TNF-α, play a role in regulating the expression of the CYP4F family. One of the isoforms, CYP4F11, had different characteristics than that of the other five CYP4F family members. CYP4F11 metabolizes xenobiotics while the other isoforms metabolize endogenous compounds with higher affinity. CYP4F11 also was expressed at high quantities in the brain, and was up-regulated by TNF-α, while the other isoforms were not expressed at high quantities in the brain and were down-regulated by TNF-α. We identified the AP-1 protein of the JNK pathway as the signaling protein that causes significant increase in CYP4F11 expression. Since TNF-α stimulation causes a simultaneous activation of both JNK pathway and NF-κB signaling, we investigated further the role that NF-κB plays on expression of the CYP4F11 gene. We concluded that although there is a significant increase in CYP4F11 expression in the presence of TNF-α, the activation of NF-κB signaling inhibits CYP4F11 expression in a time dependent manner. The expression of CYP4F11 is only significantly increased after 24 hours of treatment with TNF-α; at shorter time points NF-κB signaling overpowers the JNK pathway activation. We believe that these findings may in the future lead to improved drug design for modulating inflammation.
Resumo:
Abstract The objectives of this study were: 1) To determine factors which inhibit and facilitate child and adolescent use of outdoor spaces for healthy physical activity by race and ethnicity in four Houston communities and 2) To propose guidelines for encouraging and maintaining child and adolescent outdoor physical activity. Using local health data and Houston Police Department crime statistics, four communities were identified for the study that had the highest concentration of crime and the racial/ ethnic groups of interest. The researchers then identified public parks in the communities. At least two parks were observed in each of the four communities from 2010 to 2011 during spring, summer, fall and winter. The parks were observed for use by children and adolescents and to describe the condition of the park spaces. The communities were Alief (Asian), Sunnyside (Black), Eldridge- West Oaks (White) and Northside- Northline (Hispanic). Observations were made at varying hours of both day and night, weekdays and weekends. Photographs were taken and the condition of the spaces noted in detail. One hundred and twenty persons, 18 years and over, using the spaces or otherwise in these communities were conveniently sampled and interviewed about their health and the extent to which they, or any children or adolescents under their care, used the outdoor spaces of interest. Data were analyzed qualitatively and with basic descriptive statistics. The photographs, journal notes and observation notes of all investigators and key personnel were analyzed. Interview data were also coded to identify patterns and themes in the responses. The findings indicate disparities in the quality and quantity of park equipment and the maintenance of the areas. Where perceptions of disorder were described, there was often visible evidence to support the perceptions. In many cases, residents' perceptions of crime were corroborated by police data. While interview reports did not seem to support the expectation that the condition of the parks was a significant deterrent to their use by children and adolescents, the condition of the parks might be said to limit the extent of that use. Specific reports of disorder that inhibited use included hearing gunfire, seeing drug dependent homeless persons and/or suspected prostitutes in an area.
Resumo:
This exploratory study was conducted to examine the relationship between nursing home organizational variables and variations in financial efficiency and effectiveness in Texas nursing homes. Efficiency was defined in terms of nursing home profit, contribution margin, and administrative costs. Effectiveness was defined as the level of the quality of care measured by Texas Department of Health annual surveys of Medicaid certified facilities.^ A sample of 318 intermediate care facilities was selected from a population of 1,026 Texas nursing homes operating in 1987. Location was not found to be related to nursing home effectiveness. Nursing home ownership was positively related to financial efficiency. A moderate amount of quality of care variation was explained by examining nursing home size, employee turnover rate, labor hours per patient day and occupancy rate.^ The number of labor hours per patient day and employee turnover rate were significantly related negatively to both measures of profitability and quality of care. ^
Resumo:
Background Atrial fibrillation (AF) is common and may have severe consequences. Continuous long-term electrocardiogram (ECG) is widely used for AF screening. Recently, commercial ECG analysis software was launched, which automatically detects AF in long-term ECGs. It has been claimed that such tools offer reliable AF screening and save time for ECG analysis. However, this has not been investigated in a real-life patient cohort. Objective To investigate the performance of automatic software-based screening for AF in long-term ECGs. Methods Two independent physicians manually screened 22,601 hours of continuous long-term ECGs from 150 patients for AF. Presence, number, and duration of AF episodes were registered. Subsequently, the recordings were screened for AF by an established ECG analysis software (Pathfinder SL), and its performance was validated against the thorough manual analysis (gold standard). Results Sensitivity and specificity for AF detection was 98.5% (95% confidence interval 91.72%–99.96%) and 80.21% (95% confidence interval 70.83%–87.64%), respectively. Software-based AF detection was inferior to manual analysis by physicians (P < .0001). Median AF duration was underestimated (19.4 hours vs 22.1 hours; P < .001) and median number of AF episodes was overestimated (32 episodes vs 2 episodes; P < .001) by the software. In comparison to extensive quantitative manual ECG analysis, software-based analysis saved time (2 minutes vs 19 minutes; P < .001). Conclusion Owing to its high sensitivity and ability to save time, software-based ECG analysis may be used as a screening tool for AF. An additional manual confirmatory analysis may be required to reduce the number of false-positive findings.
Resumo:
A new technique for the detection of microbiological fecal pollution in drinking and in raw surface water has been modified and tested against the standard multiple-tube fermentation technique (most-probable-number, MPN). The performance of the new test in detecting fecal pollution in drinking water has been tested at different incubation temperatures. The basis for the new test was the detection of hydrogen sulfide produced by the hydrogen sulfide producing bacteria which are usually associated with the coliform group. The positive results are indicated by the appearance of a brown to black color in the contents of the fermentation tube within 18 to 24 hours of incubation at 35 (+OR-) .5(DEGREES)C. For this study 158 water samples of different sources have been used. The results were analyzed statistically with the paired t-test and the one-way analysis of variance. No statistically significant difference was noticed between the two methods, when tested 35 (+OR-) .5(DEGREES)C, in detecting fecal pollution in drinking water. The new test showed more positive results with raw surface water, which could be due to the presence of hydrogen sulfide producing bacteria of non-fecal origin like Desulfovibrio and Desulfomaculum. The survival of the hydrogen sulfide producing bacteria and the coliforms was also tested over a 7-day period, and the results showed no significant difference. The two methods showed no significant difference when used to detect fecal pollution at a very low coliform density. The results showed that the new test is mostly effective, in detecting fecal pollution in drinking water, when used at 35 (+OR-) .5(DEGREES)C. The new test is effective, simple, and less expensive when used to detect fecal pollution in drinking water and raw surface water at 35 (+OR-) .5(DEGREES)C. The method can be used for qualitative and/or quantitative analysis of water in the field and in the laboratory. ^
Resumo:
BACKGROUND AND PURPOSE Intravenous thrombolysis for acute ischemic stroke is beneficial within 4.5 hours of symptom onset, but the effect rapidly decreases over time, necessitating quick diagnostic in-hospital work-up. Initial time strain occasionally results in treatment of patients with an alternate diagnosis (stroke mimics). We investigated whether intravenous thrombolysis is safe in these patients. METHODS In this multicenter observational cohort study containing 5581 consecutive patients treated with intravenous thrombolysis, we determined the frequency and the clinical characteristics of stroke mimics. For safety, we compared the symptomatic intracranial hemorrhage (European Cooperative Acute Stroke Study II [ECASS-II] definition) rate of stroke mimics with ischemic strokes. RESULTS One hundred stroke mimics were identified, resulting in a frequency of 1.8% (95% confidence interval, 1.5-2.2). Patients with a stroke mimic were younger, more often female, and had fewer risk factors except smoking and previous stroke or transient ischemic attack. The symptomatic intracranial hemorrhage rate in stroke mimics was 1.0% (95% confidence interval, 0.0-5.0) compared with 7.9% (95% confidence interval, 7.2-8.7) in ischemic strokes. CONCLUSIONS In experienced stroke centers, among patients treated with intravenous thrombolysis, only a few had a final diagnosis other than stroke. The complication rate in these stroke mimics was low.
Resumo:
INTRODUCTION Hemodynamic management in intensive care patients guided by blood pressure and flow measurements often do not sufficiently reveal common hemodynamic problems. Trans-esophageal echocardiography (TEE) allows for direct measurement of cardiac volumes and function. A new miniaturized probe for TEE (mTEE) potentially provides a rapid and simplified approach to monitor cardiac function. The aim of the study was to assess the feasibility of hemodynamic monitoring using mTEE in critically ill patients after a brief operator training period. METHODS In the context of the introduction of mTEE in a large ICU, 14 ICU staff specialists with no previous TEE experience received six hours of training as mTEE operators. The feasibility of mTEE and the quality of the obtained hemodynamic information were assessed. Three standard views were acquired in hemodynamically unstable patients: 1) for assessment of left ventricular function (LV) fractional area change (FAC) was obtained from a trans-gastric mid-esophageal short axis view, 2) right ventricular (RV) size was obtained from mid-esophageal four chamber view, and 3) superior vena cava collapsibility for detection of hypovolemia was assessed from mid-esophageal ascending aortic short axis view. Off-line blinded assessment by an expert cardiologist was considered as a reference. Inter-rater agreement was assessed using Chi-square tests or correlation analysis as appropriate. RESULTS In 55 patients, 148 mTEE examinations were performed. Acquisition of loops in sufficient quality was possible in 110 examinations for trans-gastric mid-esophageal short axis, 118 examinations for mid-esophageal four chamber and 125 examinations for mid-esophageal ascending aortic short axis view. Inter-rater agreement (Kappa) between ICU mTEE operators and the reference was 0.62 for estimates of LV function, 0.65 for RV dilatation, 0.76 for hypovolemia and 0.77 for occurrence of pericardial effusion (all P < 0.0001). There was a significant correlation between the FAC measured by ICU operators and the reference (r = 0.794, P (one-tailed) < 0.0001). CONCLUSIONS Echocardiographic examinations using mTEE after brief bed-side training were feasible and of sufficient quality in a majority of examined ICU patients with good inter-rater reliability between mTEE operators and an expert cardiologist. Further studies are required to assess the impact of hemodynamic monitoring by mTEE on relevant patient outcomes.
Resumo:
In recent years, development of information systems (IS) has rapidly changed towards increasing division of labor between firms. Two trends are emerging. First, client companies increasingly outsource software development to external service providers. Second, the formerly oligopolistic enterprise application software industry has started to disintegrate into focal partnership networks – so called platform ecosystems. Despite the increasing prominence of IS outsourcing and platform ecosystems, many of these inter-organizational partnerships fail to achieve expected benefits. Ineffective governance and control frequently plays a pivotal role in producing these failures. While designing effective governance and control mechanisms is always challenging, inter-organizational software development projects are often business-critical and exhibit additional dynamics and uncertainty. As a consequence governance and control have to be adapted over time. The three research projects included in this book provide a better understanding of how and why governance and control can be effectively adapted over time. The implications for successful management of inter-organizational software development projects are highly relevant for theory and practice.
Resumo:
Introduction Previous studies on the influence of torsion and combined torsion-compression loading revealed a positive effect on the cell viability when a repetitive short-term torsion was applied at a physiological magnitude to intervertebral disc organ culture.1 However, after an extended period (8 hours) of combined torsion-compression loading, substantial cell death was detected in the nucleus pulposus (NP).2 In this follow-up study, we aimed to investigate the relationship, if any, between the duration of torsion applied to the intervertebral disc (IVD) and the level of NP cell viability. Materials and Methods Bovine caudal discs were harvested and cultured in a custom-built multiaxis dynamic loading bioreactor.2 Torsion (± 2 degrees) was applied to the samples at a frequency of 0.2 Hz. Torsion was applied for durations of 0, 1, 4, and 8 h/d, repeated over 7 days. After the last day of loading, disc tissue was dissected for analysis of cell viability and gene expression. Results Disc NP cell viability remained above 85% after torsional loading for 0, 1, or 4 h/d. Viability was statistical significantly reduced to below 70% when torsion was applied for 8 h/d (p = 0.03) (Table 1). The daily duration of torsional loading did not affect the AF cell viability (> 80% for all loading durations). The trend of collagen 2 gene upregulation and matrix metalloproteases 13 downregulation with an increasing duration of torsion was observed in both NP and AF (Fig. 1).Conclusion We have demonstrated that an extended duration of torsion could inhibit the survival of NP cells within the IVD in organ culture. Acknowledgments Funds from the Orthopedic Department of the Insel University Hospital of Bern and a private donation from Prof. Dr. Paul Heini, Spine Surgeon, Sonnenhof Clinic Bern were received to support this work. Disclosure of Interest None declared References References 1 Chan SC, Ferguson SJ, Wuertz K, Gantenbein-Ritter B. Biological response of the intervertebral disc to repetitive short-term cyclic torsion. Spine 2011;36(24):2021–2030 2 Chan SC, Walser J, Käppeli P, Shamsollahi MJ, Ferguson SJ, Gantenbein-Ritter B. Region specific response of intervertebral disc cells to complex dynamic loading: an organ culture study using a dynamic torsion-compression bioreactor. PLoS ONE 2013;8(8):e72489
Resumo:
OBJECTIVES In cardiac muscle, ischemia reperfusion (IR) injury is attenuated by mitochondrial function, which may be upregulated by focal adhesion kinase (FAK). The aim of this study was to determine whether increased FAK levels reduced rhabdomyolysis in skeletal muscle too. MATERIAL AND METHODS In a translational in vivo experiment, rat lower limbs were subjected to 4 hours of ischemia followed by 24 or 72 hours of reperfusion. FAK expression was stimulated 7 days before (via somatic transfection with pCMV-driven FAK expression plasmid) and outcomes were measured against non-transfected and empty transfected controls. Slow oxidative (i.e., mitochondria-rich) and fast glycolytic (i.e., mitochondria-poor) type muscles were analyzed separately regarding rhabdomyolysis, apoptosis, and inflammation. Severity of IR injury was assessed using paired non-ischemic controls. RESULTS After 24 hours of reperfusion, marked rhabdomyolysis was found in non-transfected and empty plasmid-transfected fast-type glycolytic muscle, tibialis anterior. Prior transfection enhanced FAK concentration significantly (p = 0.01). Concomitantly, levels of BAX, promoting mitochondrial transition pores, were reduced sixfold (p = 0.02) together with a blunted inflammation (p = 0.01) and reduced rhabdomyolysis (p = 0.003). Slow oxidative muscle, m. soleus, reacted differently: although apoptosis was detectable after IR, rhabdomyolysis did not appear before 72 hours of reperfusion; and FAK levels were not enhanced in ischemic muscle despite transfection (p = 0.66). CONCLUSIONS IR-induced skeletal muscle rhabdomyolysis is a fiber type-specific phenomenon that appears to be modulated by mitochondria reserves. Stimulation of FAK may exploit these reserves constituting a potential therapeutic approach to reduce tissue loss following acute limb IR in fast-type muscle.