919 resultados para Forensic medicin
Resumo:
Liquid chromatography coupled with mass spectrometry is one of the most powerful tools in the toxicologist’s arsenal to detect a wide variety of compounds from many different matrices. However, the huge number of potentially abused substances and new substances especially designed as intoxicants poses a problem in a forensic toxicology setting. Most methods are targeted and designed to cover a very specific drug or group of drugs while many other substances remain undetected. High resolution mass spectrometry, more specifically time-of-flight mass spectrometry, represents an extremely powerful tool in analysing a multitude of compounds not only simultaneously but also retroactively. The data obtained through the time-of-flight instrument contains all compounds made available from sample extraction and chromatography, which can be processed at a later time with an improved library to detect previously unrecognised compounds without having to analyse the respective sample again. The aim of this project was to determine the utility and limitations of time-of-flight mass spectrometry as a general and easily expandable screening method. The resolution of time-of-flight mass spectrometry allows for the separation of compounds with the same nominal mass but distinct exact masses without the need to separate them chromatographically. To simulate the wide variety of potentially encountered drugs in such a general screening method, seven drugs (morphine, cocaine, zolpidem, diazepam, amphetamine, MDEA and THC) were chosen to represent this variety in terms of mass, properties and functional groups. Consequently, several liquid-liquid and solid phase extractions were applied to urine samples to determine the most general suitable and unspecific extraction. Chromatography was optimised by investigating the parameters pH, concentration, organic solvent and gradient of the mobile phase to improve data obtained by the time-of-flight instrument. The resulting method was validated as a qualitative confirmation/identification method. Data processing was automated using the software TargetAnalysis, which provides excellent analyte recognition according to retention time, exact mass and isotope pattern. The recognition of isotope patterns allows excellent recognition of analytes even in interference rich mass spectra and proved to be a good positive indicator. Finally, the validated method was applied to samples received from the A& E Department of Glasgow Royal Infirmary in suspected drug abuse cases and samples received from the Scottish Prison Service, which we received from their own prevalence study targeting drugs of abuse in the prison population. The obtained data was processed with a library established in the course of this work.
Resumo:
Esta investigación midió la percepción del personal asistencial sobre la cultura de seguridad de los pacientes en un hospital de primer nivel de complejidad por medio de un estudio descriptivo de corte transversal. Se utilizó como herramienta de medición la encuesta ‘Hospital Survey on Patient Safety Cultura’ (HSOPSC) de la Agency of Healthcare Research and Quality (AHRQ) versión en español, la cual evalúa doce dimensiones. Los resultados mostraron fortalezas como el aprendizaje organizacional, las mejoras continuas y el apoyo de los administradores para la seguridad del paciente. Las dimensiones clasificadas como oportunidades de mejora fueron la cultura no punitiva, el personal, las transferencias y transiciones y el grado en que la comunicación es abierta. Se concluyó que aunque el personal percibía como positivo el proceso de mejoramiento y apoyo de la administración también sentía que era juzgado si reportaba algún evento adverso.
Resumo:
Determinar la validez concurrente del Sistema de Observación de Tiempo de Instrucción de Condición Física (SOFIT) a través de acelerometría, como método para medir los niveles de actividad física (AF) de los escolares de 1º a 9º durante la clase de educación física en tres colegios públicos de Bogotá, Colombia. Estudio transversal entre Octubre de 2014 y Marzo de 2015. La medición se realizó en tres colegios públicos de Bogotá. Participaron 48 estudiantes (25 niñas; 23 niños), entre 5 y 17 años, seleccionados de acuerdo al protocolo de SOFIT. El resultado se categoriza en porcentaje de tiempo en comportamiento sedentario, AF moderada, AF vigorosa, y AF moderada a vigorosa. Se validó utilizando como patrón de oro la acelerometría en las mismas categorías. Se realizó diferencia de medias, regresión lineal y modelo de efectos fijos. La correlación entre SOFIT y acelerometría fue buena para AF moderada (rho=,958; p=0,000), AF vigorosa (rho=,937; p=0,000) y AF de moderada a vigorosa (rho=0,962; p=0,000). Al igual que utilizando un modelo de efectos fijos, AF moderada (β1=0,92; p=0,00), vigorosa (β1=0,94; p=0,00) y AF de moderada a vigorosa (β1=0,95; p=0,00), mostrando ausencia de diferencias significativas entre los dos métodos para la medición de los niveles de AF. El comportamiento sedentario correlacionó positivamente en Spearman (rho=,0965; p=0,000), El sistema SOFIT demostró ser válido para medir niveles de AF en clases de educación física, tras buena correlación y concordancia con acelerometría. SOFIT es un instrumento de fácil acceso y de bajo costo para la medición de la AF durante las clases de educación física en el contexto escolar y se recomienda su uso en futuros estudios.
Resumo:
Objetivo: Evaluar las propiedades psicométricas de los instrumentos para la medición de la actividad física en adultos de 18-65 años con discapacidad física por lesión de médula espinal. Materiales y métodos: Revisión sistemática. Las bases de datos de Medline, Scopus, Web of Science y 19 revistas especializadas fueron consultadas durante once días entre abril de 2015 y febrero de 2016 para identificar estudios originales de validación, sin límite de tiempo y que estuvieran publicados en español, francés y/o inglés. La calidad metodológica de los instrumentos de medición se evaluó usando las diferentes cajas de propiedades de la lista COSMIN. Resultados: Se identificaron 9229 referencias, de las cuales sólo 12 cumplieron los criterios de inclusión, dando como resultado 13 instrumentos de medición. Se evaluaron seis propiedades psicométricas. La propiedad más común fue la confiabilidad, además se observó que la calidad metodológica de los estudios incluidos no representa los resultados de las propiedades psicométricas de los instrumentos de medición. La calidad metodológica de los instrumentos para la evaluación de la actividad física en población con lesión medular espinal es “baja” para propiedades como consistencia interna, error de medición, sensibilidad, validez de criterio (con excepción del WISCI II que tiene buena validez) y excelente para validez de contenido y fiabilidad. Conclusión: Se ha encontrado que instrumentos empleados hasta el presente en la medición de la actividad física en población con discapacidad física relacionada con lesión de médula espinal han sido creados para otros tipos de discapacidad y otros instrumentos deben ser validados en futuros estudios.
Resumo:
Values of ultraviolet global solar radiation were measured with an ultraviolet radiometer and also predicted with an atmospheric spectral model. The values obtained with the atmospheric spectral model, which is physically based, were analyzed and compared with the experimental values measured in situ. The measurements were performed for different zenith angles under clear skies conditions in Heredia, Costa Rica. The necessary input data include latitude, altitude, surface albedo, Earth-Sun distance, as well as atmospheric characteristics: atmospheric turbidity, precipitable water and atmospheric ozone. The comparisons between the measured and predicted values gave satisfactory results.
Resumo:
In this Ph.D. project, original and innovative approaches for the quali-quantitative analysis of abuse substances, as well as therapeutic agents with abuse potential and related compounds were designed, developed and validated for application to different fields such as forensics, clinical and pharmaceutical. All the parameters involved in the developed analytical workflows were properly and accurately optimised, from sample collection to sample pretreatment up to the instrumental analysis. Advanced dried blood microsampling technologies have been developed, able of bringing several advantages to the method as a whole, such as significant reduction of solvent use, feasible storage and transportation conditions and enhancement of analyte stability. At the same time, the use of capillary blood allows to increase subject compliance and overall method applicability by exploiting such innovative technologies. Both biological and non-biological samples involved in this project were subjected to optimised pretreatment techniques developed ad-hoc for each target analyte, making also use of advanced microextraction techniques. Finally, original and advanced instrumental analytical methods have been developed based on high and ultra-high performance liquid chromatography (HPLC,UHPLC) coupled to different detection means (mainly mass spectrometry, but also electrochemical, and spectrophotometric detection for screening purpose), and on attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) for solid-state analysis. Each method has been designed to obtain highly selective, sensitive yet sustainable systems and has been validated according to international guidelines. All the methods developed herein proved to be suitable for the analysis of the compounds under investigation and may be useful tools in medicinal chemistry, pharmaceutical analysis, within clinical studies and forensic investigations.
Resumo:
Introduction. Synthetic cannabinoid receptor agonists (SCRAs) represent the widest group of New Psychoactive Substances (NPS) and, around 2021-2022, new compounds emerged on the market. The aims of the present research were to identify suitable urinary markers of Cumyl-CB-MEGACLONE, Cumyl-NB-MEGACLONE, Cumyl-NB-MINACA, 5F-EDMB-PICA, EDMB-PINACA and ADB-HEXINACA, to present data on their prevalence and to adapt the methodology from the University of Freiburg to the University of Bologna. Materials and methods. Human phase-I metabolites detected in 46 authentic urine samples were confirmed in vitro with pooled human liver microsomes (pHLM) assays, analyzed by liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-qToF-MS). Prevalence data were obtained from urines collected for abstinence control programs. The method to study SCRAs metabolism in use at the University of Freiburg was adapted to the local facilities, tested in vitro with 5F-EDMB-PICA and applied to the study of ADB-HEXINACA metabolism. Results. Metabolites built by mono, di- and tri-hydroxylation were recommended as specific urinary biomarkers to monitor the consumption of SCRAs bearing a cumyl moiety. Monohydroxylated and defluorinated metabolites were suitable proof of 5F-EDMB-PICA consumption. Products of monohydroxylation and amide or ester hydrolysis, coupled to monohydroxylation or ketone formation, were recognized as specific markers for EDMB-PINACA and ADB-HEXINACA. The LC-qToF-MS method was successfully adapted to the University of Bologna, as tested with 5F-EDMB-PICA in vitro metabolites. Prevalence data showed that 5F-EDMB-PINACA and EDMB-PINACA were more prevalent than ADB-HEXINACA, but for a limited period. Conclusion. Due to undetectability of parent compounds in urines and to shared metabolites among structurally related compounds, the identification of specific urinary biomarkers as unequivocal proofs of SCRAs consumption remains challenging for forensic laboratories. Urinary biomarkers are necessary to monitor SCRAs abuse and prevalence data could help in establishing tailored strategies to prevent their spreading, highlighting the role for legal medicine as a service to public health.
Resumo:
New DNA-based predictive tests for physical characteristics and inference of ancestry are highly informative tools that are being increasingly used in forensic genetic analysis. Two eye colour prediction models: a Bayesian classifier - Snipper and a multinomial logistic regression (MLR) system for the Irisplex assay, have been described for the analysis of unadmixed European populations. Since multiple SNPs in combination contribute in varying degrees to eye colour predictability in Europeans, it is likely that these predictive tests will perform in different ways amongst admixed populations that have European co-ancestry, compared to unadmixed Europeans. In this study we examined 99 individuals from two admixed South American populations comparing eye colour versus ancestry in order to reveal a direct correlation of light eye colour phenotypes with European co-ancestry in admixed individuals. Additionally, eye colour prediction following six prediction models, using varying numbers of SNPs and based on Snipper and MLR, were applied to the study populations. Furthermore, patterns of eye colour prediction have been inferred for a set of publicly available admixed and globally distributed populations from the HGDP-CEPH panel and 1000 Genomes databases with a special emphasis on admixed American populations similar to those of the study samples.
Resumo:
The use of screening techniques, such as an alternative light source (ALS), is important for finding biological evidence at a crime scene. The objective of this study was to evaluate whether biological fluid (blood, semen, saliva, and urine) deposited on different surfaces changes as a function of the age of the sample. Stains were illuminated with a Megamaxx™ ALS System and photographed with a Canon EOS Utility™ camera. Adobe Photoshop™ was utilized to prepare photographs for analysis, and then ImageJ™ was used to record the brightness values of pixels in the images. Data were submitted to analysis of variance using a generalized linear mixed model with two fixed effects (surface and fluid). Time was treated as a random effect (through repeated measures) with a first-order autoregressive covariance structure. Means of significant effects were compared by the Tukey test. The fluorescence of the analyzed biological material varied depending on the age of the sample. Fluorescence was lower when the samples were moist. Fluorescence remained constant when the sample was dry, up to the maximum period analyzed (60 days), independent of the substrate on which the fluid was deposited, showing the novelty of this study. Therefore, the forensic expert can detect biological fluids at the crime scene using an ALS even several days after a crime has occurred.
Resumo:
Using a desorption/ionization technique, easy ambient sonic-spray ionization coupled to mass spectrometry (EASI-MS), documents related to the 2nd generation of Brazilian Real currency (R$) were screened in the positive ion mode for authenticity based on chemical profiles obtained directly from the banknote surface. Characteristic profiles were observed for authentic, seized suspect counterfeit and counterfeited homemade banknotes from inkjet and laserjet printers. The chemicals in the authentic banknotes' surface were detected via a few minor sets of ions, namely from the plasticizers bis(2-ethylhexyl)phthalate (DEHP) and dibutyl phthalate (DBP), most likely related to the official offset printing process, and other common quaternary ammonium cations, presenting a similar chemical profile to 1st-generation R$. The seized suspect counterfeit banknotes, however, displayed abundant diagnostic ions in the m/z 400-800 range due to the presence of oligomers. High-accuracy FT-ICR MS analysis enabled molecular formula assignment for each ion. The ions were separated by 44 m/z, which enabled their characterization as Surfynol® 4XX (S4XX, XX=40, 65, and 85), wherein increasing XX values indicate increasing amounts of ethoxylation on a backbone of 2,4,7,9-tetramethyl-5-decyne-4,7-diol (Surfynol® 104). Sodiated triethylene glycol monobutyl ether (TBG) of m/z 229 (C10H22O4Na) was also identified in the seized counterfeit banknotes via EASI(+) FT-ICR MS. Surfynol® and TBG are constituents of inks used for inkjet printing.
Resumo:
With a huge amount of printed documents nowadays, identifying their source is useful for criminal investigations and also to authenticate digital copies of a document. In this paper, we propose novel techniques for laser printer attribution. Our solutions do not need very high resolution scanning of the investigated document and explore the multidirectional, multiscale and low-level gradient texture patterns yielded by printing devices. The main contributions of this work are: (1) the description of printed areas using multidirectional and multiscale co-occurring texture patterns; (2) description of texture on low-level gradient areas by a convolution texture gradient filter that emphasizes textures in specific transition areas and (3) the analysis of printer patterns in segments of interest, which we call frames, instead of whole documents or only printed letters. We show by experiments in a well documented dataset that the proposed methods outperform techniques described in the literature and present near-perfect classification accuracy being very promising for deployment in real-world forensic investigations.
Resumo:
The aim of this study was to develop a methodology using Raman hyperspectral imaging and chemometric methods for identification of pre- and post-blast explosive residues on banknote surfaces. The explosives studied were of military, commercial and propellant uses. After the acquisition of the hyperspectral imaging, independent component analysis (ICA) was applied to extract the pure spectra and the distribution of the corresponding image constituents. The performance of the methodology was evaluated by the explained variance and the lack of fit of the models, by comparing the ICA recovered spectra with the reference spectra using correlation coefficients and by the presence of rotational ambiguity in the ICA solutions. The methodology was applied to forensic samples to solve an automated teller machine explosion case. Independent component analysis proved to be a suitable method of resolving curves, achieving equivalent performance with the multivariate curve resolution with alternating least squares (MCR-ALS) method. At low concentrations, MCR-ALS presents some limitations, as it did not provide the correct solution. The detection limit of the methodology presented in this study was 50μgcm(-2).
Resumo:
In this review recent methods developed and applied to solve criminal occurences related to documentoscopy, ballistic and drugs of abuse are discussed. In documentoscopy, aging of ink writings, the sequence of line crossings and counterfeiting of documents are aspects to be solved with reproducible, fast and non-destructive methods. In ballistic, the industries are currently producing ''lead-free'' or ''nontoxic'' handgun ammunitions, so new methods of gunshot residues characterization are being presented. For drugs analysis, easy ambient sonic-spray ionization mass spectrometry (EASI-MS) is shown to provide a relatively simple and selective screening tool to distinguish m-CPP and amphetamines (MDMA) tablets, cocaine and LSD.
Resumo:
Este artigo de revisão sistemática tem por objetivo citar os métodos de identificação humana por meio da radiologia, utilizados em odontologia legal. Para isso, realizou-se revisão de literatura com 19 trabalhos selecionados dentre 45 encontrados, após aplicação de critérios de inclusão. Há diversas técnicas radiológicas que podem ser utilizadas para auxiliar na identificação humana, tanto individual como geral, incluindo a determinação do gênero, do grupo étnico e, principalmente, da idade. A análise de radiografias e tomografias ante-mortem e post-mortem tornou-se uma ferramenta fundamental nos processos de identificação em odontologia legal, principalmente com o refinamento das técnicas adquiridas com o avanço da própria radio-logia e com a incorporação da informática. Conclui-se que a partir do conhecimento adequado dos métodos disponíveis, o profissional em odontologia legal pode optar pelo método que melhor preencha as características necessárias para o sucesso da identificação, tendo cuidado na aplicação correta da técnica e na interpretação precisa das informações obtidas.
Resumo:
Designer drug is a term used to describe psychoactive drugs of abuse which are usually synthesized by modifying the molecular structures of existing drugs of abuse. The term gained widespread popularity when MDMA (ecstasy) experienced a popularity boom in the mid 1980´s. In Brazil, designer drugs seizures have increased in the last few years, and actually tablets with unknown psychoactive compounds began to be forwarded to the Forensic Laboratories. This work describes the analytical assays that were performed to identify the chlorophenylpiperazine, a psychoactive substance first time identified in seized tablets in Sao Paulo state.