1000 resultados para Fe:YAP
Resumo:
Nanoparticles are of immense importance both from the fundamental and application points of view. They exhibit quantum size effects which are manifested in their improved magnetic and electric properties. Mechanical attrition by high energy ball milling (HEBM) is a top down process for producing fine particles. However, fineness is associated with high surface area and hence is prone to oxidation which has a detrimental effect on the useful properties of these materials. Passivation of nanoparticles is known to inhibit surface oxidation. At the same time, coating polymer film on inorganic materials modifies the surface properties drastically. In this work a modified set-up consisting of an RF plasma polymerization technique is employed to coat a thin layer of a polymer film on Fe nanoparticles produced by HEBM. Ball-milled particles having different particle size ranges are coated with polyaniline. Their electrical properties are investigated by measuring the dc conductivity in the temperature range 10–300 K. The low temperature dc conductivity (I–V ) exhibited nonlinearity. This nonlinearity observed is explained on the basis of the critical path model. There is clear-cut evidence for the occurrence of intergranular tunnelling. The results are presented here in this paper
Resumo:
Metglas 2826 MB having a nominal composition of Fe40Ni38Mo4B18 is an excellent soft magnetic material and finds application in sensors and memory heads. However, the thin-film forms of Fe40Ni38Mo4B18 are seldom studied, although they are important in micro-electro-mechanical systems/nano-electromechanical systems devices. The stoichiometry of the film plays a vital role in determining the structural and magnetic properties of Fe40Ni38Mo4B18 thin films: retaining the composition in thin films is a challenge. Thin films of 52 nm thickness were fabricated by RF sputtering technique on silicon substrate from a target of nominal composition of Fe40Ni38Mo4B18. The films were annealed at temperatures of 400 °C and 600 °C. The micro-structural studies of films using glancing x-ray diffractometer (GXRD) and transmission electron microscope (TEM) revealed that pristine films are crystalline with (FeNiMo)23B6 phase. Atomic force microscope (AFM) images were subjected to power spectral density analysis to understand the probable surface evolution mechanism during sputtering and annealing. X-ray photoelectron spectroscopy (XPS) was employed to determine the film composition. The sluggish growth of crystallites with annealing is attributed to the presence of molybdenum in the thin film. The observed changes in magnetic properties were correlated with annealing induced structural, compositional and morphological changes
Resumo:
The Raman and FTIR spectra of [C(NH2)3]2M(SO4)2 ·6H2O (withM= Co, Fe, Ni) were recorded and analysed. The observed spectral bands are assigned in terms of vibrations of guanidinium ions, sulphate groups and water molecules. The analysis shows that the sulphate tetrahedra are distorted from their free state symmetry Td to C1. This is attributed to the presence of hydrogen bonds from water molecules. The order of distortion of the metal oxygen octahedra influenced the distortion of the sulphate tetrahedra. The appearance of 1– 3 modes of water molecules above 3300 cm−1 indicates the presence of weak hydrogen bonds
Resumo:
Magnetism and magnetic materials have been playing a lead role in improving the quality of life. They are increasingly being used in a wide variety of applications ranging from compasses to modern technological devices. Metallic glasses occupy an important position among magnetic materials. They assume importance both from a scientific and an application point of view since they represent an amorphous form of condensed matter with significant deviation from thermodynamic equilibrium. Metallic glasses having good soft magnetic properties are widely used in tape recorder heads, cores of high-power transformers and metallic shields. Superconducting metallic glasses are being used to produce high magnetic fields and magnetic levitation effect. Upon heat treatment, they undergo structural relaxation leading to subtle rearrangements of constituent atoms. This leads to densification of amorphous phase and subsequent nanocrystallisation. The short-range structural relaxation phenomenon gives rise to significant variations in physical, mechanical and magnetic properties. Magnetic amorphous alloys of Co-Fe exhibit excellent soft magnetic properties which make them promising candidates for applications as transformer cores, sensors, and actuators. With the advent of microminiaturization and nanotechnology, thin film forms of these alloys are sought after for soft under layers for perpendicular recording media. The thin film forms of these alloys can also be used for fabrication of magnetic micro electro mechanical systems (magnetic MEMS). In bulk, they are drawn in the form of ribbons, often by melt spinning. The main constituents of these alloys are Co, Fe, Ni, Si, Mo and B. Mo acts as the grain growth inhibitor and Si and B facilitate the amorphous nature in the alloy structure. The ferromagnetic phases such as Co-Fe and Fe-Ni in the alloy composition determine the soft magnetic properties. The grain correlation length, a measure of the grain size, often determines the soft magnetic properties of these alloys. Amorphous alloys could be restructured in to their nanocrystalline counterparts by different techniques. The structure of nanocrystalline material consists of nanosized ferromagnetic crystallites embedded in an amorphous matrix. When the amorphous phase is ferromagnetic, they facilitate exchange coupling between nanocrystallites. This exchange coupling results in the vanishing of magnetocrystalline anisotropy which improves the soft magnetic properties. From a fundamental perspective, exchange correlation length and grain size are the deciding factors that determine the magnetic properties of these nanocrystalline materials. In thin films, surfaces and interfaces predominantly decides the bulk property and hence tailoring the surface roughness and morphology of the film could result in modified magnetic properties. Surface modifications can be achieved by thermal annealing at various temperatures. Ion irradiation is an alternative tool to modify the surface/structural properties. The surface evolution of a thin film under swift heavy ion (SHI) irradiation is an outcome of different competing mechanism. It could be sputtering induced by SHI followed by surface roughening process and the material transport induced smoothening process. The impingement of ions with different fluence on the alloy is bound to produce systematic microstructural changes and this could effectively be used for tailoring magnetic parameters namely coercivity, saturation magnetization, magnetic permeability and remanence of these materials. Swift heavy ion irradiation is a novel and an ingenious tool for surface modification which eventually will lead to changes in the bulk as well as surface magnetic property. SHI has been widely used as a method for the creation of latent tracks in thin films. The bombardment of SHI modifies the surfaces or interfaces or creates defects, which induces strain in the film. These changes will have profound influence on the magnetic anisotropy and the magnetisation of the specimen. Thus inducing structural and morphological changes by thermal annealing and swift heavy ion irradiation, which in turn induce changes in the magnetic properties of these alloys, is one of the motivation of this study. Multiferroic and magneto-electrics is a class of functional materials with wide application potential and are of great interest to material scientists and engineers. Magnetoelectric materials combine both magnetic as well as ferroelectric properties in a single specimen. The dielectric properties of such materials can be controlled by the application of an external magnetic field and the magnetic properties by an electric field. Composites with magnetic and piezo/ferroelectric individual phases are found to have strong magnetoelectric (ME) response at room temperature and hence are preferred to single phasic multiferroic materials. Currently research in this class of materials is towards optimization of the ME coupling by tailoring the piezoelectric and magnetostrictive properties of the two individual components of ME composites. The magnetoelectric coupling constant (MECC) (_ ME) is the parameter that decides the extent of interdependence of magnetic and electric response of the composite structure. Extensive investigates have been carried out in bulk composites possessing on giant ME coupling. These materials are fabricated by either gluing the individual components to each other or mixing the magnetic material to a piezoelectric matrix. The most extensively investigated material combinations are Lead Zirconate Titanate (PZT) or Lead Magnesium Niobate-Lead Titanate (PMNPT) as the piezoelectric, and Terfenol-D as the magnetostrictive phase and the coupling is measured in different configurations like transverse, longitudinal and inplane longitudinal. Fabrication of a lead free multiferroic composite with a strong ME response is the need of the hour from a device application point of view. The multilayer structure is expected to be far superior to bulk composites in terms of ME coupling since the piezoelectric (PE) layer can easily be poled electrically to enhance the piezoelectricity and hence the ME effect. The giant magnetostriction reported in the Co-Fe thin films makes it an ideal candidate for the ferromagnetic component and BaTiO3 which is a well known ferroelectric material with improved piezoelectric properties as the ferroelectric component. The multilayer structure of BaTiO3- CoFe- BaTiO3 is an ideal system to understand the underlying fundamental physics behind the ME coupling mechanism. Giant magnetoelectric coupling coefficient is anticipated for these multilayer structures of BaTiO3-CoFe-BaTiO3. This makes it an ideal candidate for cantilever applications in magnetic MEMS/NEMS devices. SrTiO3 is an incipient ferroelectric material which is paraelectric up to 0K in its pure unstressed form. Recently few studies showed that ferroelectricity can be induced by application of stress or by chemical / isotopic substitution. The search for room temperature magnetoelectric coupling in SrTiO3-CoFe-SrTiO3 multilayer structures is of fundamental interest. Yet another motivation of the present work is to fabricate multilayer structures consisting of CoFe/ BaTiO3 and CoFe/ SrTiO3 for possible giant ME coupling coefficient (MECC) values. These are lead free and hence promising candidates for MEMS applications. The elucidation of mechanism for the giant MECC also will be the part of the objective of this investigation.
Resumo:
La publicación contiene índice de figuras, de cuadros, de gráficos, de fotografías y de actividades de trabajo.
Resumo:
Debido a la gran cantidad de muestras arqueológicas impregnadas con PEG que se encuentran contaminadas por compuestos insolubles de hierro, se plantea la posible extracción y formación de complejos Fe-L (L=PBTC) y sus efectos en (i) la estructura de la matriz orgánica, (ii) la estructura y propiedades físicas del PEG y (iii) el comportamiento de la muestra en la etapa posterior de almacenamiento. El proyecto analiza la formación de compuestos químicos y posibles modificaciones estructurales en el proceso de extracción del hierro. Consiste en un estudio sistemático de un sistema químico y su influencia en los procesos de precipitación de Fe3+ en medio acuoso. El proyecto se fundamenta en: (1) desarrollar un proceso experimental de optimización para la extracción de las sales contaminantes y (2) encontrar las técnicas analíticas óptimas que permitan apreciar modificaciones estructurales de los diferentes sistemas. Se determina la cantidad de hierro extraído mediante A.A. Las interacciones entre PBTC y PEG se analizan por IR. Las modificaciones de determinadas propiedades físicas se determinan por DSC y las estructurales mediante SEM. En las condiciones termodinámicas óptimas se obtiene una extracción superficial del hierro (30-35%). La disolución del PEG origina modificaciones de la masa y el volumen de la muestra
Resumo:
Debido a que el 12% de la población tendrá un cálculo en uréter hacia la mitad de su vida y a que las tasas de recurrencia en los que ya lo presentan son del 50% es necesario estudiar esta patología para aproximarse a un manejo adecuado en el servicio de urgencias. La literatura identifica un conjunto de factores que pueden contribuir a un cambio en el manejo médico. Objetivo: El objetivo de este estudio fue determinar los factores demográficos y clínicos asociados a manejo hospitalario en los pacientes con diagnóstico de cálculo ureteral menor de 10 mm. Métodos: Se diseñó un estudio de casos y controles no emparejados. Un caso fue definido como un paciente de 18 o más años con diagnóstico de urolitiasis con cálculo menor a 10 mm realizado por urotac que consultó (por primera vez para ese episodio) al servicio de urgencias de la Fundación Santa Fe de Bogotá entre el 1 de marzo de 2007 y 30 de abril de 2012. Se indagaron factores como edad, sexo, tamaño y localización del cálculo, respuesta a los analgésicos, evidencia de obstrucción e infección urinaria, además de otros antecedentes medicamentosos y clínicos. Se utilizó regresión logística no condicional bivariada y multivariada para evaluar la asociación entre tipo de manejo (hospitalario o ambulatorio) y las variables recolectadas, calculando odds ratio (OR) e intervalos de confianza al 95% (IC95%). Resultados: El riesgo de hospitalización se incrementó con: 1. La localización del cálculo en tercio superior o medio (OR=1.49; IC95%: 0.751-2.966) al comparar con el inferior, 2. El aumento del tamaño del cálculo (OR=1.49; IC95%: 0.751-2.966, por cada milímetro de incremento), y 3: Por la evidencia de obstrucción o infección urinaria y elevación de azoados. Por el contrario, hubo menos riesgo de hospitalización en aquellos pacientes con una respuesta analgésica apropiada en urgencias.
Resumo:
Objetivo: Caracterizar a los pacientes que recibieron ventilación mecánica en las unidades de cuidado intensivo (UCI) de la Fundación Santa Fe de Bogotá entre los años 2009 y 2013. Metodología: Se analizó una cohorte retrospectiva de los pacientes en UCI que requirieron soporte ventilatorio mecánico al ingreso a la unidad independientemente de la causa. Resultados: La media de edad de los pacientes fue 63,83 años; el diagnóstico más frecuente de ingreso fue revascularización miocárdica, seguido por neumonía y recambio valvular aórtico; en el 43% de los casos la causa de la falla fue el estado postoperatorio. Los modos ventilatorios más frecuentemente utilizados fueron SIMV (27,5%) y ventilación asistida controlada (26,12%). El 50% de los pacientes fueron ventilados con PEEP < 6 cmH2O. La mortalidad bruta fue del 15%. 22% de los pacientes tuvieron estancia prolongada en UCI. Se aplicó protocolo de retiro de ventilación mecánica en el 77% de los pacientes. La duración de la ventilación mecánica es mayor a medida que aumenta la edad del paciente entre los 60 y los 80 años. La mortalidad es cercana al 50% alrededor de los 50 años y mayor a 80% después de los 80 años. El soporte ventilatorio por cinco o más días aumentó la mortalidad a 80% o más. Discusión y Conclusiones: Estos resultados son comparables a los encontrados en estudios previos. Este estudio puede ser considerado como el primer paso para generar un registro adecuado de la ventilación de la mecánica de las unidades de cuidado intensivo del país.
Resumo:
Introducción: En los pacientes críticamente enfermos la terapia transfusional es una práctica común. Dentro de los estudios realizados no se han incluido a las ciudades a mayor altura. Este estudio pretende determinar los niveles de hemoglobina sobre los cuales se está transfundiendo a los pacientes en la unidad de cuidados intensivos del Hospital Universitario Fundación Santa Fe de Bogotá a 2600 metros sobre el nivel del mar, para determinar si los niveles de hemoglobina a los que se transfunde a nuestra altura son los óptimos. Métodos: Se realizó un estudio descriptivo retrospectivo, de los pacientes que fueron hospitalizados en la Unidad de Cuidado Intensivo del Hospital Universitario Fundación Santa Fe de Bogotá a partir del 01 de Junio de 2011 y hasta el 31 de Mayo de 2012. Resultados: Del total de los registros analizados el 13,8% de los pacientes presentaron una hemoglobina ≤ 7 y todos fueron transfundidos con glóbulos rojos; y en el rango de 7,1-9 se presentó el mayor porcentaje de transfusión. Se observó que los pacientes con hemoglobina ≤ 7 tienen 18,8 veces mayor riego de fallecimiento, lo que fue estadísticamente significativo (p:0,000). Conclusiones: Encontramos que la terapia transfusional en la unidad de cuidado intensivo, se realiza de acuerdo a recomendaciones dadas por las guías de manejo universalmente aceptadas. Dentro de los resultados de nuestro estudio podemos resaltar una tasa de mortalidad más alta en los pacientes en los cuales se instaura terapia transfusional con un nivel de hemoglobina por debajo de 7g/dl.
Resumo:
La Organización Mundial de la Salud define la Medicina Nuclear como una especialidad que se ocupa del diagnóstico, tratamiento e investigación básica o clínica mediante el uso de trazadores radiactivos en medicina cuyo origen estuvo dirigido a estudios dinámicos y funcionales, realizado por primera vez en seres humano por Hevesy en 1.935. En Colombia, la medicina nuclear nace el 28 de julio de 1.955 cuando el Dr. Jaime Cortazar administra la primera dosis de I-131 en un paciente con hipetiroidismo en el Instituto Nacional de Radium, hoy en día conocido como el instituto Nacional de Cancerología. La primera gamacámaras, llegaron al país en la década de los años 70 como parte del Plan nacional hospitalario y fueron instaladas en el Instituto Nacional de Cancerología, y el hospital Militar Central, donde surgieron las primeras escuela de Medicina nuclear del país. En la actualidad, el Hospital de San José y la Fundación CardioInfaltil, también ofrecen esta profesión.
Resumo:
en el presente estudio se ha analizado el recurso humano de cuatro localidades de Santa Fe de Bogotá, con el fin de crear un sistema que mejore los procesos de contratación, capacitación, remuneración y motivación de las personas.
Resumo:
Analizar comparativamente las características morfo-funcionales de las Unidades motoras reclutadas durante la realización de una RM en el músculo recto anterior (cuadriceps bilateral) en futbolistas entre 15 a 20 años del equipo de fútbol de la división sub-21 de Santa fe por medio de la electromiografia. La medición electromiográfica ha demostrado que el reclutamiento de fibras es mayor, en deportistas en comparación con personas sedentarias debido a que tienen un manejo diferente de la potencia, entendiendo esta como la integración de la velocidad con fuerza máxima, una cualidad determinante en cualquier tipo de salto, o cambios rápidos de dirección, como en la potencia de despegue, arranque, aceleración y/o desaceleración.
Resumo:
Específicamente en el sector salud tantas veces motivo de discusión, la mayoría de sus proyectos afectan directa o indirectamente la calidad de vida de las personas de forma no claramente cuantificable, siendo las externalidades positivas o negativas
Resumo:
El hombre como ser social siente la necesidad de organizarse para satisfacer sus necesidades y las de su contexto, es por eso que utilizamos estrategias de vinculación de individuos y establecemos relaciones que nos permiten el intercambio de experiencias, metodologías y recursos que orientan nuestro quehacer, como en la labor de cuidar; la cual requiere de varias acciones encaminadas hacia el desarrollo optimo de su tarea y demanda del apoyo adecuado que facilite su desempeño. Esta labor se hace aún más dispendiosa cuando se tiene bajo el cuidado un miembro cercano de nuestra familia o una persona a quien le tenemos gran afecto y debemos gran respeto, como sucede con un adulto mayor en situación de discapacidad.
Resumo:
se logró diseñar una serie de estrategias y programas , específicos para cada uno de los postgrados y fijar un plazo estricto para su cumplimiento.