999 resultados para Facsimile transmission


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wind-excited vibrations in the frequency range of 10 to 50 Hz due to vortex shedding often cause fatigue failures in the cables of overhead transmission lines. Damping devices, such as the Stockbridge dampers, have been in use for a long time for supressing these vibrations. The dampers are conveniently modelled by means of their driving point impedance, measured in the lab over the frequency range under consideration. The cables can be modelled as strings with additional small bending stiffness. The main problem in modelling the vibrations does however lay in the aerodynamic forces, which usually are approximated by the forces acting on a rigid cylinder in planar flow. In the present paper, the wind forces are represented by stochastic processes with arbitrary crosscorrelation in space; the case of a Kármán vortex street on a rigid cylinder in planar flow is contained as a limit case in this approach. The authors believe that this new view of the problem may yield useful results, particularly also concerning the reliability of the lines and the probability of fatigue damages. © 1987.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have investigated and extensively tested three families of non-convex optimization approaches for solving the transmission network expansion planning problem: simulated annealing (SA), genetic algorithms (GA), and tabu search algorithms (TS). The paper compares the main features of the three approaches and presents an integrated view of these methodologies. A hybrid approach is then proposed which presents performances which are far better than the ones obtained with any of these approaches individually. Results obtained in tests performed with large scale real-life networks are summarized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To study translocation of Xylella fastidiosa to citrus rootstocks, budsticks from citrus variegated chlorosis (CVC)-affected cv. Pera sweet orange (Citrus sinenesis (L.) Osb.) were top grafted on 15 citrus rootstocks. Disease symptoms were conspicuous 3 months later on all 15 rootstocks tested. The presence of X. fastidiosa was confirmed by light microscopy, double-antibody sandwich enzyme-linked immunosorbent assays, and polymerase chain reaction in rootlets and main roots of CVC-symptomatic Pera sweet orange in 11 of the 15 rootstocks tested. These results suggest that bacterial translocation from the aerial plant parts to the root system occurs but is not essential for X. fastidiosa to induce symptoms in the aerial parts. Bacterial translocation to the roots was not correlated with CVC leaf-symptom severity in the Pera scion. To determine if CVC disease could be transmitted by natural root grafts, two matched seedlings of each of four sweet orange cultivars (Pera, Natal, Valencia, and Caipira) were transplanted into single pots. One seedling rootstock of each pair was inoculated by top grafting with a CVC-contaminated budstick while the other seedling rootstock was cut but not graft inoculated. Transmission of X. fastidiosa from an inoculated plant to a noninoculated plant sharing the same pot was observed in all four sweet orange cultivars tested. Transmission was confirmed by observation of natural roots grafts between the two plants, presence of X. fastidiosa in the root grafts, and disease development in the uninoculated plants. This is the first report of transmission of CVC disease through natural root grafts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Silicon crystal exhibits a ductile regime during machining prior to the onset of fracture when appropriate cutting conditions are applied. The present study shows that the ductile regime is a result of a phase transformation which is indirectly evidenced by the amorphous phase detected in the machined surface. Transmission electron microscopy (TEM) planar view studies were successfully performed on monocrystalline silicon (1 0 0) single point diamond turned. TEM electron diffraction patterns show that the machined surface presents diffuse rings along with traces of crystalline material. This is attributed to crystalline silicon immersed in an amorphous matrix. Furthermore, only diffuse rings in the diffraction patterns of the ductile chip are detected, indicating that it is totally amorphous. © 2000 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Xylella fastidiosa, a xylem-limited bacterium, causes several economically important diseases in North, Central, and South America. These diseases are transmitted by sharpshooter insects, contaminated budwood, and natural root-grafts. X. fastidiosa extensively colonizes the xylem vessels of susceptible plants. Citrus fruit have a well-developed vascular system, which is continuous with the vascular system of the plant. Citrus seeds develop very prominent vascular bundles, which are attached through ovular and seed bundles to the xylem system of the fruit. Sweet orange (Citrus sinensis) fruit of cvs. Pera, Natal, and Valencia with characteristic symptoms of citrus variegated chlorosis disease were collected for analysis. X. fastidiosa was detected by polymerase chain reaction (PCR) in all main fruit vascular bundles, as well as in the seed and in dissected seed parts. No visual abnormalities were observed in seeds infected with the bacterium. However, the embryos of the infected seeds weighed 25% less than those of healthy seeds, and their germination rate was lower than uninfected seeds. There were about 2,500 cells of X. fastidiosa per infected seed of sweet orange, as quantified using real-time PCR techniques. The identification of X. fastidiosa in the infected seeds was confirmed by cloning and sequencing the specific amplification product, obtained by standard PCR with specific primers. X. fastidiosa was also detected in and recovered from seedlings by isolation in vitro. Our results show that X. fastidiosa can infect and colonize fruit tissues including the seed. We also have shown that X. fastidiosa can be transmitted from seeds to seedlings of sweet orange. To our knowledge, this is the first report of the presence of X. fastidiosa in seeds and its transmission to seedlings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper a method for solving the Short Term Transmission Network Expansion Planning (STTNEP) problem is presented. The STTNEP is a very complex mixed integer nonlinear programming problem that presents a combinatorial explosion in the search space. In this work we present a constructive heuristic algorithm to find a solution of the STTNEP of excellent quality. In each step of the algorithm a sensitivity index is used to add a circuit (transmission line or transformer) to the system. This sensitivity index is obtained solving the STTNEP problem considering as a continuous variable the number of circuits to be added (relaxed problem). The relaxed problem is a large and complex nonlinear programming and was solved through an interior points method that uses a combination of the multiple predictor corrector and multiple centrality corrections methods, both belonging to the family of higher order interior points method (HOIPM). Tests were carried out using a modified Carver system and the results presented show the good performance of both the constructive heuristic algorithm to solve the STTNEP problem and the HOIPM used in each step.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an alternative methodology for loading margin improvement and total real power losses reduction by using a continuation method. In order to attain this goal, a parameterizing equation based on the total real power losses and the equations of the reactive power at the slack and generation buses are added to the conventional power flow equations. The voltages at these buses are considered as control variables and a new parameter is chosen to reduce the real power losses in the transmission lines. The results show that this procedure leads to maximum loading point increase and consequently, in static voltage stability margin improvement. Besides, this procedure also takes to a reduction in the operational costs and, simultaneously, to voltage profile improvement. Another important result of this methodology is that the resulting operating points are close to that provided by an optimal power flow program. © 2004 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analysis of the performances of three important methods for generators and loads loss allocation is presented. The discussed methods are: based on pro-rata technique; based on the incremental technique; and based on matrices of circuit. The algorithms are tested considering different generation conditions, using a known electric power system: IEEE 14 bus. Presented and discussed results verify: the location and the magnitude of generators and loads; the possibility to have agents well or poorly located in each network configuration; the discriminatory behavior considering variations in the power flow in the transmission lines. © 2004 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a branch-and-bound algorithm to solve the multi-stage transmission expansion planning problem. The well known transportation model is employed, nevertheless the algorithm can be extended to hybrid models or to more complex ones such as the DC model. Tests with a realistic power system were carried out in order to show the performance of the algorithm for the expansion plan executed for different time frames. © 2005 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this paper is to show an alternative methodology to calculate transmission line parameters per unit length. With this methodology the transmission line parameters can be obtained starting from the phase currents and voltages in one terminal of the line. First, the article shows the classical methodology to calculate frequency dependent transmission line parameters by using Carson's and Pollaczeck's equations for representing the ground effect and Bessel's functions to represent the skin effect. After that, it is shown a new procedure to calculate frequency dependent transmission line parameters directly from currents and voltages of the line that is already built. Then, this procedure is applied in a two-phase transmission line whose parameters have been previously calculated by using the classical methodology. Finally, the results obtained by using the new procedure and by using the classical methodology are compared. ©2005 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a mathematical model and a methodology to solve the transmission network expansion planning problem with security constraints in full competitive market, assuming that all generation programming plans present in the system operation are known. The methodology let us find an optimal transmission network expansion plan that allows the power system to operate adequately in each one of the generation programming plans specified in the full competitive market case, including a single contingency situation with generation rescheduling using the security (n-1) criterion. In this context, the centralized expansion planning with security constraints and the expansion planning in full competitive market are subsets of the proposal presented in this paper. The model provides a solution using a genetic algorithm designed to efficiently solve the reliable expansion planning in full competitive market. The results obtained for several known systems from the literature show the excellent performance of the proposed methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cleft lip and/or palate (CL/P) is a major congenital defect with complex etiology, including multiple genetic and environmental factors. Approximately two thirds of the cases are not accompanied by other anomalies and are called nonsyndromic (NS). In the present study, we performed transmission distortion analysis of the MSX1-CA, TGFB3-CA and MTHFR-C677T polymorphisms in 60 parent-child triads, in which the NS-CL/ P affected child had at least one affected parent. No association with genes MSX1 or TGFB3 was found, but the results were suggestive of an association of the MTHFR-C677T polymorphism with NS-CL/P. © 2006 Sociedade Brasileira de Genética.