1000 resultados para FLOATING BODY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study focuses on the effect of the material type and the lubricant on the abrasive wear behaviour of two important commercially available ceramic on ceramic prosthetic systems, namely, Biolox(R) forte and Bioloxl(R) delta (CeramTec AG, Germany). A standard microabrasion wear apparatus was used to produce '3-body' abrasive wear scars with three different lubricants: ultrapure water, 25 vol% new-born calf serum solution and 1 wt% carboxymethyl cellulose sodium salt (CMC-Na) solution. 1 mu m alumina particles were used as the abrasive. The morphology of the wear scar was examined in detail using Atomic Force Microscopy (AFM) and Scanning Electron Microscopy (SEM). Subsurface damage accumulation was investigated by Focused Ion Beam (FIB) cross-sectional milling and Transmission Electron Microscopy (TEM). The effect of the lubricant on the '3-body' abrasive wear mechanisms is discussed and the effect of material properties compared. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some retrieved CoCrMo hip implants have shown that abrasive wear is one of the possible wear mechanisms invoked within such joints. To date, little work has focused on the third body abrasion of CoCrMo and therefore there is a general lack of understanding of the effect of abrasive size and volume concentration on the tribo-corrosion performance of the CoCrMo alloys. The present work assessed the tribo-corrosion behaviour of cast CoCrMo (F-75) under various abrasion-corrosion conditions by using a modified microabrasion tester incorporating a three-electrode electrochemical cell. The effects of reduced abrasive size/hardness and volume concentration, as well as the role of proteins on the tribo-corrosion performance of the cast CoCrMo alloy were addressed. The correlation between electrochemical and mechanical processes for different abrasion-corrosion test conditions has been discussed in detail. Results show that the reduction in abrasive size and volume concentration can significantly affect the abrasion-corrosion wear mechanisms and the wear-induced corrosion response of the material. The finding of this study implies that the smaller/softer third body particles generated in vivo could also result in significant wear-induced corrosion and therefore potential metal ion release, which could be potentially detrimental to both the patient health and the life span of the implants. © 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we compare a number of the classical models used to characterize fading in body area networks (BANs) with the recently proposed shadowed ț–ȝ fading model. In particular, we focus on BAN channels which are considered to be susceptible to shadowing by the human body. The measurements considered in this study were conducted at 2.45 GHz for hypothetical BAN channels operating in both anechoic and highly reverberant environments while the person was moving. Compared to the Rice, Nakagami and lognormal fading models, it was found that the recently proposed shadowed ț௅μ fading model provided an enhanced fit to the measured data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using device-to-device communications as an underlay for cellular communications will provide an exciting opportunity to increase network capacity as well as improving spectral efficiency. The unique geometry of device-to-device links, where user equipment is often held or carried at low elevation and in close proximity to the human body, will mean that they are particularly susceptible to shadowing events caused not only by the local environment but also by the user's body. In this paper, the shadowed κ - μ fading model is proposed, which is capable of characterizing shadowed fading in wireless communication channels. In this model, the statistics of the received signal are manifested by the clustering of multipath components. Within each of these clusters, a dominant signal component with arbitrary power may exist. The resultant dominant signal component, which is formed by the phasor addition of these leading contributions, is assumed to follow a Nakagami- m distribution. The probability density function, moments, and the moment-generating function are also derived. The new model is then applied to device-to-device links operating at 868 MHz in an outdoor urban environment. It was found that shadowing of the resultant dominant component can vary significantly depending upon the position of the user equipment relative to the body and the link geometry. Overall, the shadowed κ - μ fading model is shown to provide a good fit to the field data as well as providing a useful insight into the characteristics of the received signal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The association between body size and head and neck cancers (HNCA) is unclear, partly because of the biases in case–control studies. Methods: In the prospective NIH–AARP cohort study, 218,854 participants (132,288 men and 86,566 women), aged 50 to 71 years, were cancer free at baseline (1995 and 1996), and had valid anthropometric data. Cox proportional hazards regression was used to examine the associations between body size and HNCA, adjusted for current and past smoking habits, alcohol intake, education, race, and fruit and vegetable consumption, and reported as HR and 95% confidence intervals (CI). Results: Until December 31, 2006, 779 incident HNCAs occurred: 342 in the oral cavity, 120 in the oro- and hypopharynx, 265 in the larynx, 12 in the nasopharynx, and 40 at overlapping sites. There was an inverse association between HNCA and body mass index, which was almost exclusively among current smokers (HR = 0.76 per each 5 U increase; 95% CI, 0.63–0.93), and diminished as initial years of follow-up were excluded. We observed a direct association with waist-to-hip ratio (HR = 1.16 per 0.1 U increase; 95% CI, 1.03–1.31), particularly for cancers of the oral cavity (HR, 1.40; 95% CI, 1.17–1.67). Height was also directly associated with total HNCAs (P = 0.02), and oro- and hypopharyngeal cancers (P < 0.01). Conclusions: The risk of HNCAs was associated inversely with leanness among current smokers, and directly with abdominal obesity and height. Impact: Our study provides evidence that the association between leanness and risk of HNCAs may be due to effect modification by smoking. Cancer Epidemiol Biomarkers Prev; 23(11); 2422–9. ©2014 AACR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: The effect of dietary sucrose on insulin resistance and the pathogenesis of diabetes and vascular disease is unclear. We assessed the effect of 5% versus 15% sucrose intakes as part of a weight maintaining, eucaloric diet in overweight/obese subjects.

METHODS: Thirteen subjects took part in a randomised controlled crossover study (M:F 9:4, median age 46 years, range 37-56 years, BMI 31.7±0.9 kg/m(2)). Subjects completed two 6 week dietary periods separated by 4 week washout. Diets were designed to have identical macronutrient profile. Insulin action was assessed using a two-step hyperinsulinaemic euglycaemic clamp; glucose tolerance, vascular compliance, body composition and lipid profiles were also assessed.

RESULTS: There was no change in weight or body composition between diets. There was no difference in peripheral glucose utilization or suppression of endogenous glucose production. Fasting glucose was significantly lower after the 5% diet. There was no demonstrated effect on lipid profiles, blood pressure or vascular compliance.

CONCLUSION: A low-sucrose diet had no beneficial effect on insulin resistance as measured by the euglycaemic glucose clamp. However, reductions in fasting glucose, one hour insulin and insulin area under the curve with the low sucrose diet on glucose tolerance testing may indicate a beneficial effect and further work is required to determine if this is the case. Clinical Trial Registration number ISRCTN50808730.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the importance of laughter in social interactions it remains little studied in affective computing. Respiratory, auditory, and facial laughter signals have been investigated but laughter-related body movements have received almost no attention. The aim of this study is twofold: first an investigation into observers' perception of laughter states (hilarious, social, awkward, fake, and non-laughter) based on body movements alone, through their categorization of avatars animated with natural and acted motion capture data. Significant differences in torso and limb movements were found between animations perceived as containing laughter and those perceived as nonlaughter. Hilarious laughter also differed from social laughter in the amount of bending of the spine, the amount of shoulder rotation and the amount of hand movement. The body movement features indicative of laughter differed between sitting and standing avatar postures. Based on the positive findings in this perceptual study, the second aim is to investigate the possibility of automatically predicting the distributions of observer's ratings for the laughter states. The findings show that the automated laughter recognition rates approach human rating levels, with the Random Forest method yielding the best performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The propagation of UWB signals for body-centric communications within a modern classroom/conference room environment was investigated. Presented results demonstrate that the body-antenna mounting position has a marked impact on the received power levels and positioning the antenna on the chest as opposed to the shoulder or wrist creates more extreme values in receive power, mean excess delay and rms delay spread. Additionally, the best fit models for each scenario are presented and highlight the difference between the chest and other compared antenna locations. The work concluded that the chest is a poor choice of mounting position for the antenna due to significant body shadowing effects, with the wrist or shoulder considered better options for UWB systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obesity has been linked with elevated levels of C-reactive protein (CRP), and both have been associated with increased risk of mortality and cardiovascular disease (CVD). Previous studies have used a single ‘baseline’ measurement and such analyses cannot account for possible changes in these which may lead to a biased estimation of risk. Using four cohorts from CHANCES which had repeated measures in participants 50 years and older, multivariate time-dependent Cox proportional hazards was used to estimate hazard ratios (HR) and 95 % confidence intervals (CI) to examine the relationship between body mass index (BMI) and CRP with all-cause mortality and CVD. Being overweight (≥25–<30 kg/m2) or moderately obese (≥30–<35) tended to be associated with a lower risk of mortality compared to normal (≥18.5–<25): ESTHER, HR (95 % CI) 0.69 (0.58–0.82) and 0.78 (0.63–0.97); Rotterdam, 0.86 (0.79–0.94) and 0.80 (0.72–0.89). A similar relationship was found, but only for overweight in Glostrup, HR (95 % CI) 0.88 (0.76–1.02); and moderately obese in Tromsø, HR (95 % CI) 0.79 (0.62–1.01). Associations were not evident between repeated measures of BMI and CVD. Conversely, increasing CRP concentrations, measured on more than one occasion, were associated with an increasing risk of mortality and CVD. Being overweight or moderately obese is associated with a lower risk of mortality, while CRP, independent of BMI, is positively associated with mortality and CVD risk. If inflammation links CRP and BMI, they may participate in distinct/independent pathways. Accounting for independent changes in risk factors over time may be crucial for unveiling their effects on mortality and disease morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to investigate the feasibility of using a novel granulation technique, namely, fluidized hot melt granulation (FHMG), to prepare gastroretentive extended-release floating granules. In this study we have utilized FHMG, a solvent free process in which granulation is achieved with the aid of low melting point materials, using Compritol 888 ATO and Gelucire 50/13 as meltable binders, in place of conventional liquid binders. The physicochemical properties, morphology, floating properties, and drug release of the manufactured granules were investigated. Granules prepared by this method were spherical in shape and showed good flowability. The floating granules exhibited sustained release exceeding 10 h. Granule buoyancy (floating time and strength) and drug release properties were significantly influenced by formulation variables such as excipient type and concentration, and the physical characteristics (particle size, hydrophilicity) of the excipients. Drug release rate was increased by increasing the concentration of hydroxypropyl cellulose (HPC) and Gelucire 50/13, or by decreasing the particle size of HPC. Floating strength was improved through the incorporation of sodium bicarbonate and citric acid. Furthermore, floating strength was influenced by the concentration of HPC within the formulation. Granules prepared in this way show good physical characteristics, floating ability, and drug release properties when placed in simulated gastric fluid. Moreover, the drug release and floating properties can be controlled by modification of the ratio or physical characteristics of the excipients used in the formulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Body fat distribution is a heritable trait and a well-established predictor of adverse metabolic outcomes, independent of overall adiposity. To increase our understanding of the genetic basis of body fat distribution and its molecular links to cardiometabolic traits, here we conduct genome-wide association meta-analyses of traits related to waist and hip circumferences in up to 224,459 individuals. We identify 49 loci (33 new) associated with waist-to-hip ratio adjusted for body mass index (BMI), and an additional 19 loci newly associated with related waist and hip circumference measures (P < 5 × 10(-8)). In total, 20 of the 49 waist-to-hip ratio adjusted for BMI loci show significant sexual dimorphism, 19 of which display a stronger effect in women. The identified loci were enriched for genes expressed in adipose tissue and for putative regulatory elements in adipocytes. Pathway analyses implicated adipogenesis, angiogenesis, transcriptional regulation and insulin resistance as processes affecting fat distribution, providing insight into potential pathophysiological mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obesity is heritable and predisposes to many diseases. To understand the genetic basis of obesity better, here we conduct a genome-wide association study and Metabochip meta-analysis of body mass index (BMI), a measure commonly used to define obesity and assess adiposity, in up to 339,224 individuals. This analysis identifies 97 BMI-associated loci (P < 5 × 10(-8)), 56 of which are novel. Five loci demonstrate clear evidence of several independent association signals, and many loci have significant effects on other metabolic phenotypes. The 97 loci account for ∼2.7% of BMI variation, and genome-wide estimates suggest that common variation accounts for >20% of BMI variation. Pathway analyses provide strong support for a role of the central nervous system in obesity susceptibility and implicate new genes and pathways, including those related to synaptic function, glutamate signalling, insulin secretion/action, energy metabolism, lipid biology and adipogenesis.