919 resultados para spool-and-line device
Resumo:
In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensure that the planned dosimetric coverage of the tumor volume is actually realized in the patient. Since the direction of setup fields often deviates from the direction of the treatment beams, extra dose is delivered to the patient during the acquisition of these portal images which may reach clinical relevance. The aim of this work was to develop a new acquisition mode for the PortalVision aS500 electronic portal imaging device from Varian Medical Systems that allows one to take portal images with reduced dose while keeping good image quality. The new acquisition mode, called RadMode, selectively enables and disables beam pulses during image acquisition allowing one to stop wasting valuable dose during the initial acquisition of "reset frames." Images of excellent quality can be taken with 1 MU only. This low dose per image facilitates daily setup verification with considerably reduced extra dose.
Resumo:
BACKGROUND AND PURPOSE: The purpose of the study was to compare efficacy and potential complications of 2 commercially available devices for mechanical thromboembolectomy. METHODS: Devices were tested in an established animal model allowing the use of routine angiography catheters and thrombectomy devices. Radio-opaque thrombi were used for visualization of thrombus-device interaction during angiography. The Merci Retrieval System and the Catch Thromboembolectomy System were assessed each in 10 vessel occlusions. For every occluded vessel up to 5 retrieval attempts were performed. RESULTS: Sufficient recanalization was achieved with the Merci Retriever in 90% of occlusions, and with the Catch device recanalization was achieved in 70% of occlusions. Recanalization at the first attempt occurred significantly more often with the Merci Retriever compared to the Catch device (OR, 21; 95% CI, 1.78-248.11). Consequently, significantly more attempts (P=0.02) had to be performed with the Catch device; therefore, time to recanalization was longer. Thrombus fragmentations during retrieval were caused more often by the Catch device compared to the Merci Retriever (OR, 15.6; 95% CI, 1.73-140.84), resulting in a higher distal embolization rate. During retrieval both devices lost thrombotic material at the tip of the guide catheter, which was then aspirated in most cases. CONCLUSIONS: Both distal devices are effective for thromboembolectomy. To avoid loss of thrombotic material and distal embolization, the use of large luminal balloon guide catheters and aspiration during retrieval seems to be mandatory. The design of the Merci Retriever appears to be more efficient during thrombus mobilization and retrieval with less fragmentation compared to the Catch Thromboembolectomy System.
Resumo:
OBJECTIVES: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California). BACKGROUND: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis. METHODS: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support. RESULTS: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%. CONCLUSIONS: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.
Resumo:
Non-invasive documentation methods such as surface scanning and radiological imaging are gaining in importance in the forensic field. These three-dimensional technologies provide digital 3D data, which are processed and handled in the computer. However, the sense of touch gets lost using the virtual approach. The haptic device enables the use of the sense of touch to handle and feel digital 3D data. The multifunctional application of a haptic device for forensic approaches is evaluated and illustrated in three different cases: the representation of bone fractures of the lower extremities, by traffic accidents, in a non-invasive manner; the comparison of bone injuries with the presumed injury-inflicting instrument; and in a gunshot case, the identification of the gun by the muzzle imprint, and the reconstruction of the holding position of the gun. The 3D models of the bones are generated from the Computed Tomography (CT) images. The 3D models of the exterior injuries, the injury-inflicting tools and the bone injuries, where a higher resolution is necessary, are created by the optical surface scan. The haptic device is used in combination with the software FreeForm Modelling Plus for touching the surface of the 3D models to feel the minute injuries and the surface of tools, to reposition displaced bone parts and to compare an injury-causing instrument with an injury. The repositioning of 3D models in a reconstruction is easier, faster and more precisely executed by means of using the sense of touch and with the user-friendly movement in the 3D space. For representation purposes, the fracture lines of bones are coloured. This work demonstrates that the haptic device is a suitable and efficient application in forensic science. The haptic device offers a new way in the handling of digital data in the virtual 3D space.
Resumo:
AIM: We sought to investigate the prevalence of posttraumatic stress disorder, anxiety, and depression in patients and their partners after implantation of a mechanical assist device as a bridge to heart transplantation. METHODS: This was a retrospective assessment of 41 patients (age 46.3 +/- 12.0 years; male-female ratio, 38:3; time since transplantation, 55.3 +/- 34.2 months [range, 7-122 months) and 27 partners (male-female ratio 2:25) by standardized instruments (Impact of Event Scale, Hospital Anxiety and Depression Scale), in 2 University Heart Transplant Centers (Vienna, Austria, Munster, Germany). The duration of the support systems (MicroMed DeBakey-VAD in 17 patients, Novacor in 10, Thoratec in 8, TCI HeartMate in 5, and Berlin Heart Incor in 1 patient) ranged from 28 to 711 (176 +/- 146) days. RESULTS: None of the patients, but 23% of the partners (n = 6), met the criteria for posttraumatic stress disorder (Maercker cutoff >0). The Impact of Event Scale (IES) sum scales differed significantly between the 2 groups (21.2 +/- 15.1, mean +/- SD) for the patients versus 38.1 +/- 27.8 for the partners, respectively; P = .001). Two percent of the patients, but 19% of the partners, showed mild to moderate depression; 4% of patients, but 23% of their partners, reported mild to moderate anxiety. None of the results were significantly influenced by the time since transplantation, patient age, diagnoses, type of assist device, or indication for heart transplantation. CONCLUSIONS: Despite patients being much closer to a life threat, their partners experience significantly more psychologic distress even in the long run. Our findings highlight the need for attention to the supporting persons.
Resumo:
BACKGROUND: We evaluated previously established regimens of capecitabine plus vinorelbine in older patients with advanced breast cancer stratified for presence versus absence of bone metastases. PATIENTS AND METHODS: Patients > or =65 years who had received no prior chemotherapy for advanced breast cancer received up to six 21-day cycles of vinorelbine 20 mg/m(2) i.v. on days 1 + 8 with oral capecitabine on days 1-14 (1,000 vs. 1,250 mg/m(2) daily in patients with vs. without bone involvement). RESULTS: Median age was 72 years in patients with bone metastases (n = 47) and 75 years in patients without bone metastases (n = 23). Response rates were 43% (95% confidence interval, CI, 28.3-58.8) and 57% (95% CI = 34.5-76.8), respectively. Median time to progression was 4.3 (95% CI = 3.5-6.0 months) and 7.0 months (CI = 4.1-8.3), respectively. Neutropenia was the most common toxicity, with grade 3/4 occurring in 43 and 39%, respectively. Pulmonary embolism was seen in 5 and grade 3 thrombosis in 3 patients. Other toxicities were mild to moderate. CONCLUSIONS: These regimens of capecitabine and vinorelbine are active and well tolerated in patients with advanced breast cancer > or =65 years. Response rates were comparable to published results. The lower capecitabine doses appeared appropriate given the advanced age, bone involvement and prior radiotherapy.
Resumo:
OBJECTIVES: Many flow-cytometric cell characterization methods require costly markers and colour reagents. We present here a novel device for cell discrimination based on impedance measurement of electrical cell properties in a microfluidic chip, without the need of extensive sample preparation steps and the requirement of labelling dyes. MATERIALS AND METHODS, RESULTS: We demonstrate that in-flow single cell measurements in our microchip allow for discrimination of various cell line types, such as undifferentiated mouse fibroblasts 3T3-L1 and adipocytes on the one hand, or human monocytes and in vitro differentiated dendritic cells and macrophages on the other hand. In addition, viability and apoptosis analyses were carried out successfully for Jurkat cell models. Studies on several species, including bacteria or fungi, demonstrate not only the capability to enumerate these cells, but also show that even other microbiological life cycle phases can be visualized. CONCLUSIONS: These results underline the potential of impedance spectroscopy flow cytometry as a valuable complement to other known cytometers and cell detection systems.
Resumo:
This study investigated the uptake, kinetics and cellular distribution of different surface coated quantum dots (QDs) before relating this to their toxicity. J774.A1 cells were treated with organic, COOH and NH2 (PEG) surface coated QDs (40 nM). Model 20 nm and 200 nm COOH-modified coated polystyrene beads (PBs) were also examined (50 microg ml(-1)). The potential for uptake of QDs was examined by both fixed and live cell confocal microscopy as well as by flow cytometry over 2 h. Both the COOH 20 nm and 200 nm PBs were clearly and rapidly taken up by the J774.A1 cells, with uptake of 20 nm PBs being relatively quicker and more extensive. Similarly, COOH QDs were clearly taken up by the macrophages. Uptake of NH2 (PEG) QDs was not detectable by live cell imaging however, was observed following 3D reconstruction of fixed cells, as well as by flow cytometry. Cells treated with organic QDs, monitored by live cell imaging, showed only a small amount of uptake in a relatively small number of cells. This uptake was insufficient to be detected by flow cytometry. Imaging of fixed cells was not possible due to a loss in cell integrity related to cytotoxicity. A significant reduction (p<0.05) in the fluorescent intensity in a cell-free environment was found with organic QDs, NH2 (PEG) QDs, 20 nm and 200 nm PBs at pH 4.0 (indicative of an endosome) after 2 h, suggesting reduced stability. No evidence of exocytosis was found over 2 h. These findings confirm that surface coating has a significant influence on the mode of NP interaction with cells, as well as the subsequent consequences of that interaction.
Resumo:
Satellite measurement validations, climate models, atmospheric radiative transfer models and cloud models, all depend on accurate measurements of cloud particle size distributions, number densities, spatial distributions, and other parameters relevant to cloud microphysical processes. And many airborne instruments designed to measure size distributions and concentrations of cloud particles have large uncertainties in measuring number densities and size distributions of small ice crystals. HOLODEC (Holographic Detector for Clouds) is a new instrument that does not have many of these uncertainties and makes possible measurements that other probes have never made. The advantages of HOLODEC are inherent to the holographic method. In this dissertation, I describe HOLODEC, its in-situ measurements of cloud particles, and the results of its test flights. I present a hologram reconstruction algorithm that has a sample spacing that does not vary with reconstruction distance. This reconstruction algorithm accurately reconstructs the field to all distances inside a typical holographic measurement volume as proven by comparison with analytical solutions to the Huygens-Fresnel diffraction integral. It is fast to compute, and has diffraction limited resolution. Further, described herein is an algorithm that can find the position along the optical axis of small particles as well as large complex-shaped particles. I explain an implementation of these algorithms that is an efficient, robust, automated program that allows us to process holograms on a computer cluster in a reasonable time. I show size distributions and number densities of cloud particles, and show that they are within the uncertainty of independent measurements made with another measurement method. The feasibility of another cloud particle instrument that has advantages over new standard instruments is proven. These advantages include a unique ability to detect shattered particles using three-dimensional positions, and a sample volume size that does not vary with particle size or airspeed. It also is able to yield two-dimensional particle profiles using the same measurements.
Resumo:
The application of photonic crystal technology on metal-oxide film is a very promising field for future optical telecommunication systems. Band gap and polarization effects in lithium niobate (LiNbO3) photonic crystals and bismuth-substituted iron garnets (BiYIG) photonic crystals are investigated in this work reported here. The design and fabrication process are similar for these two materials while the applications are different, involving Bragg filtering in lithium niobate and polarization rotation in nonreciprocal iron garnets. The research of photonic structures in LiNbO3 is of high interest for integrated device application due to its remarkable electro-optical characteristics. This work investigated the photonic band gap in high quality LiNbO3 single crystalline thin film by ion implantation to realize high efficiency narrow bandwidth filters. LiNbO3 thin film detachment by bonding is also demonstrated for optical device integration. One-dimensional Bragg BiYIG waveguides in gyrotropic system are found to have multiple stopbands and evince enhancement of polarization rotation efficiency. Previous photon trapping theory cannot explain the phenomena because of the presence of linear birefringence. This work is aimed at investigating the mechanism with the support of experiments. The results we obtained show that selective suppression of Bloch states in gyrotropic bandgaps is the key mechanism for the observed phenomena. Finally, the research of ferroelectric single crystal PMN-PT with ultra high piezoelectric coefficient as a biosensor is also reported. This work presents an investigation and results on higher sensitivity effects than conventional materials such as quartz and lithium niobate.
Resumo:
The Michigan Department of Transportation is evaluating upgrading their portion of the Wolverine Line between Chicago and Detroit to accommodate high speed rail. This will entail upgrading the track to allow trains to run at speeds in excess of 110 miles per hour (mph). An important component of this upgrade will be to assess the requirement for ballast material for high speed rail. In the event that the existing ballast materials do not meet specifications for higher speed train, additional ballast will be required. The purpose of this study, therefore, is to investigate the current MDOT railroad ballast quality specifications and compare them to both the national and international specifications for use on high speed rail lines. The study found that while MDOT has quality specifications for railroad ballast it does not have any for high speed rail. In addition, the American Railway Engineering and Maintenance-of-Way Association (AREMA), while also having specifications for railroad ballast, does not have specific specifications for high speed rail lines. The AREMA aggregate specifications for ballast include the following tests: (1) LA Abrasion, (2) Percent Moisture Absorption, (3) Flat and Elongated Particles, (4) Sulfate Soundness test. Internationally, some countries do require a highly standard for high speed rail such as the Los Angeles (LA) Abrasion test, which is uses a higher standard performance and the Micro Duval test, which is used to determine the maximum speed that a high speed can operate at. Since there are no existing MDOT ballast specification for high speed rail, it is assumed that aggregate ballast specifications for the Wolverine Line will use the higher international specifications. The Wolverine line, however, is located in southern Michigan is a region of sedimentary rocks which generally do not meet the existing MDOT ballast specifications. The investigation found that there were only 12 quarries in the Michigan that meet the MDOT specification. Of these 12 quarries, six were igneous or metamorphic rock quarries, while six were carbonate quarries. Of the six carbonate quarries four were locate in the Lower Peninsula and two in the Upper Peninsula. Two of the carbonate quarries were located in near proximity to the Wolverine Line, while the remaining quarries were at a significant haulage distance. In either case, the cost of haulage becomes an important consideration. In this regard, four of the quarries were located with lake terminals allowing water transportation to down state ports. The Upper Peninsula also has a significant amount of metal based mining in both igneous and metamorphic rock that generate significant amount of waste rock that could be used as a ballast material. The main drawback, however, is the distance to the Wolverine rail line. One potential source is the Cliffs Natural Resources that operates two large surface mines in the Marquette area with rail and water transportation to both Lake Superior and Lake Michigan. Both mines mine rock with a very high compressive strength far in excess of most ballast materials used in the United States and would make an excellent ballast materials. Discussions with Cliffs, however, indicated that due to environmental concerns that they would most likely not be interested in producing a ballast material. In the United States carbonate aggregates, while used for ballast, many times don't meet the ballast specifications in addition to the problem of particle degradation that can lead to fouling and cementation issues. Thus, many carbonate aggregate quarries in close proximity to railroads are not used. Since Michigan has a significant amount of carbonate quarries, the research also investigated using the dynamic properties of aggregate as a possible additional test for aggregate ballast quality. The dynamic strength of a material can be assessed using a split Hopkinson Pressure Bar (SHPB). The SHPB has been traditionally used to assess the dynamic properties of metal but over the past 20 years it is now being used to assess the dynamic properties of brittle materials such as ceramics and rock. In addition, the wear properties of metals have been related to their dynamic properties. Wear or breakdown of railroad ballast materials is one of the main problems with ballast material due to the dynamic loading generated by trains and which will be significantly higher for high speed rails. Previous research has indicated that the Port Inland quarry along Lake Michigan in the Southern Upper Peninsula has significant dynamic properties that might make it potentially useable as an aggregate for high speed rail. The dynamic strength testing conducted in this research indicate that the Port Inland limestone in fact has a dynamic strength close to igneous rocks and much higher than other carbonate rocks in the Great Lakes region. It is recommended that further research be conducted to investigate the Port Inland limestone as a high speed ballast material.
Resumo:
The integration of block-copolymers and nanoimprint lithography presents a novel and cost-effective approach to achieving nanoscale patterning capabilities. The authors demonstrate the fabrication of a surface-enhanced Raman scattering device using templates created by the block-copolymers nanoimprint lithography integrated method.
Resumo:
OBJECTIVES: The C-Port System (Cardica, Inc, Redwood City, Calif) integrates in one tool all functions necessary to enable rapid automated distal coronary anastomoses. The goal of this prospective, nonrandomized, and multicenter study is to determine the safety and efficacy of this novel anastomotic system. METHODS: Five centers enrolled 133 patients awaiting elective coronary artery bypass grafting surgery. Outcome variables were intraoperative device performance, incidence of device-related adverse events, predischarge and 6-month angiographic graft patency, and 12-month clinical outcome. Independent core laboratories performed qualitative and quantitative angiographic and computed tomographic assessments. RESULTS: The C-Port was used to perform a vein-to-coronary anastomosis in 130 patients. Intraoperative conversion to a hand-sewn anastomosis was necessary in 11 patients because of inadequate target site preparation, inappropriate target vessel selection, or both. Inadequate blood flow related to poor runoff required conversion in 3 additional patients. Three patients died before discharge of causes unrelated to the device. At discharge, 113 patients had a C-Port implant in place, and 104 C-Port anastomoses were studied by means of angiography, resulting in 100 FitzGibbon A, 3 FitzGibbon B, and 1 FitzGibbon 0 classifications. At 6 months, one additional patient died of a device-unrelated cause, and 98 patients were evaluated by means of angiography (n = 89). Overall patency (FitzGibbon A) was 92.1%. Three C-Port anastomoses were rated FitzGibbon B, and 4 were rated FitzGibbon 0. At 12 months, 107 (98.2%) of 109 alive patients were followed up, without any reports of device-related major adverse cardiac events. CONCLUSIONS: The C-Port System allows for a rapid, reliable, and compliant distal anastomosis and yields favorable 6-month angiographic and 12-month clinical results when compared with published studies.