913 resultados para repetition tunable


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the LTP (Long-Term Potentiation) model of learning and memory formation, elaborated in the context of molecular neurobiology, the opening of NMDA (N-Metyl-D-Aspartate) channels to entry of calcium ions into the post-synaptic neuron depends on two excitatory events: the repeated activation of the post-synaptic neuron by only one pre-synaptic neuron (Alternative 1), or its concomitant activation by two or more pre-synaptic neurons (Alternative 2). With the purpose of testing these alternatives, in the context of Cognitive Psychology, we presented to 73 university students a sequence of slides, with the duration of 6 seconds each, containing sentences (one for each slide) considered as being relevant or irrelevant for the subjects. Relevant sentences (R1) were presented only one time, while irrelevant ones were divided in three groups: the first one with sentences presented only one time (I1), the second with sentences presented three times (I3) and the third with sentences presented five times (I5). We conjectured that relevant sentences presented only one time would mobilize two or more brain excitatory pathways (corresponding to Alternative 2 above), while repeated irrelevant sentences would progressively activate the same sensory pathway. After the presentation of the sentences, the subjects answered a written questionnaire with questions about each presented sentence. The results indicate a prevalence of correct answers to R1 over I1, I3 and I5, suggesting that the relevance factor has greater weight than repetition in the induction of declarative memories

Relevância:

10.00% 10.00%

Publicador:

Resumo:

After the discovery of ionizing radiation, its applications in various fields of science began to take significant proportions. In the case of medicine, there are the application areas in radiotherapy, diagnostic radiology and nuclear medicine. It was then necessary to create the field of radiological protection to establish the conditions necessary for the safe use of such ionizing radiation. Apply knowledge obtained during the graduation stage and in the practice of radiological protection in the areas of nuclear medicine and diagnostic radiology. In the area of nuclear medicine, tests were made in the Geiger-Muller counters (GM) and the dose calibrator (curiometer), the monitoring tests of radiation, waste management, clean of the Therapeutic room and testing the quality control of gamma-chambers. In the area of radiology, were performed tests of quality control equipment for conventional X-ray equipment and x-ray fluoroscopy, all following the rules of the National Health Surveillance Agency (ANVISA), and reporting of tests. The routine developed in the fields of nuclear medicine in hospitals has proved very useful, since the quality control of GM counters contribute to the values of possible contamination are more reliable. The control of dose calibrator enables the patient not to receive different doses of the recommended amounts, which prevents the repetition of tests and unnecessary exposure to radiation. The management of waste following the rules and laws established and required for its management. Tests for quality control of gamma chambers help to evaluate its medical performance through image. In part of diagnostic radiology, tests for quality control are performed in order to verify that the equipment is acceptable for usage or if repairs are needed. The knowledge acquired at the internship consolidated the learning of graduation course

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to determine surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence dosimetry. Twenty seven exams from different dogs were performed at the Faculdade de Medicina Veterinária e Zootecnia da Universidade Estadual Paulista (FMVZ-UNESP/Botucatu). The doses were evaluated using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN). The pulmonary metastasis exams are carried out in three projections, one dorsal-ventral and two lateral-lateral. During the procedures the projection thicknesses and source-skin surface distances were registered. To simulate the dog phantom the dosimeters were positioned in a cubic simulator (30x30x30 cm) of polymethylmethacrylate (PMMA) filled with water and irradiated according to the parameters of projections with the X-ray energies ranging from 45 to 70 kV. To estimate the surface skin dose the dose-response curves were obtained for X-ray energies of 50 and 70 kV using the diagnostic X-ray beam machine of the Instruments Calibration Laboratory of IPEN for doses of 1.5, 2.0, 2.5, 3.5 and 4.0 mGy. The main difficulty of this work was the dog immobilization that is reflected in poor-quality diagnostic imaging and, consequently, demands the repetition of the exams, which contributes to the increase of the doses received by the animals being studied and the clinical staff. The doses evaluated in this type of procedure are between 0.43 and 4.22 mGy. This research has shown to be extremely important for the assessment of doses involved in veterinary diagnostic radiology procedures, and as a parameter in the individual monitoring of pet’s owners who assist the animal positioning and occupationally exposed workers of the Department of Veterinary Radiology

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Produção Vegetal) - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Produção Vegetal) - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective – To correlate facial type measurements of Caucasian individuals with transverse dimensions of normal occlusion arches. Methods – Twenty-one pairs of dental models were selected according to the following inclusion criteria: presence of all permanent teeth from 1 st molar to 1 st molar; normal occlusion; no prosthetic crowns; no previous orthodontic treatment and 2 mm or less of crow- dings or spacings. The cephalometric measurements of lateral cephalometric X-ray of the same individuals were taken and tabulat ed. To evaluate the repetition of arch measurements, paired Student’s t-test and Pearson's correlation coefficient were used. The r elationship between the measurements was analysed by using the Pearson’s correlation. Results – The repetition of the measurements showed high correlation and no systematic error. In the comparison between the measurements, a moderate negative correlation was observed b et- ween facial axis angle and the measurements Upper and Lower 6-6, whereas a positive correlation was observed between dentition height and the latter. Conclusion – It was observed a negative correlation between facial axis angle and upper and lower inter-molar distance as well as a positive correlation between dentition height and upper and lower inter-molar distance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study focuses on the presence of covert contrasts in the speech of children with a phonological disorder. The hypothesis is that children with phonological disorders manipulate secondary acoustic cues in an attempt to distinguish the phonological contrasts. We used five audio recordings of the speech of five children with speech disorders, between four and five years of age, who showed the so-called “phonic substitution” involving the sound group of the fricatives. The data were edited and analyzed using the software PRAAT. A phonetic transcription of the first repetition of each child was performed by three evaluators, reaching a 66% agreement level. After the transcription, we carried out a contrastive phonological analysis of the production of the five children and, finally, an acoustic analysis of all the “substitutions”, based on six parameters. We discovered the existence of covert contrasts in the productions auditorily regarded as homophones by the evaluators, representing a total of 54% of total substitutions identified through an impressionistic approach by the evaluators. Children with phonological disorders are seen to rely on secondary acoustic cues in an attempt to distinguish fricative phonemes. The data obtained in this study allow us to reflect on the importance of considering the phonetic detail within the phonological models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Matemática - IBILCE

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The physic nut can be propagated asexually or sexually. Using cuttings have been earlier yield and more fidelity characteristics of the parent plant. However, there is less initial vegetative growth. The seeds from the plants have increased genetic variability, are more vigorous and begin production later. To get quality changes, the substrate is an important factor. With that the objective was to taste pre-germinated treatments and different substrate on seeds emergence and quality physic nut seedlings. The experimental design was completely randomized, in factorial scheme 6 x 3 (pre-germinated treatments x substrate), 18 treatments and 4 repetition, 8 seeds to each repetition. It was evaluated six pre-germination treatments: T1: witness (without treatments); T2: water immersion for 12 hours; T3: water immersion for 24 hours; T4: mechanical scarification; T5: mechanical scarification + water immersion for 12 hours; T6: mechanical scarification + water immersion for 24 hours, using as substrate: commercial, expanded vermiculite and sand washed. The mechanical scarification was realized opposite the micropyle using sandpaper n. 60. After the pre-germination treatments, the seeds were emergence in plastic cups (200mL) with substrates. We evaluated the characteristics: percentage, beginning and emergence speed index, mean length of plant, diameter of plant stem, SPAD index, fresh and dry shoot and root. The results showed that in seeds of Jatropha do not need pre-germinative treatments; and the use of commercial substrate showed seedling development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)