979 resultados para modified agglutination test (MAT)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new immunosensor is presented for human chorionic gonadotropin (hCG), made by electrodepositing chitosan/gold-nanoparticles over graphene screen-printed electrode (SPE). The antibody was covalently bound to CS via its Fc-terminal. The assembly was controlled by electrochemical Impedance Spectroscopy (EIS) and followed by Fourier Transformed Infrared (FTIR). The hCG-immunosensor displayed linear response against the logarithm-hCG concentration for 0.1–25 ng/mL with limit of detection of 0.016 ng/mL. High selectivity was observed in blank urine and successful detection of hCG was also achieved in spiked samples of real urine from pregnant woman. The immunosensor showed good detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemical sensors and biosensors are widely used to detect various kinds of protein target biomolecules. Molecularly Imprinted Polymers (MIPs) have raised great interest in this area, because these act as antibody-like recognition materials, with high affinity to the template molecule. Compared to natural antibodies, these are also of lower cost and higher stability. There are different types of supports used to carry MIP materials, mostly of these made of gold, favourably assembled on a Screen Printed Electrode (SPE) strategy. For this work a new kind of support for the sensing layer was developed: conductive paper. This support was made by modifying first cellulose paper with paraffin wax (to make it waterproof), and casting a carbon-ink on it afterwards, to turn it conductive. The SPAM approach previously reported in1 was employed herein to assemble to MIP sensing material on the conductive paper. The selected charged monomers were (vinylbenzyl) trimethlammonium chloride (positive charge) or vinylbenzoic acid (negative charge), used to generate binding positions with single-type charge (positive or negative). The non-specific binding area of the MIP layer was assembled by chronoamperometry-assisted polymerization (at 1 V, for 60, 120 or 180 seconds) of vinylbenzoate, cross-linked with ethylene glycol vinyl ether. The BSA biomolecules lying within the polymeric matrix were removed by Proteinase K action. All preparation stages of the MIP assembly were followed by FTIR, Raman spectroscopy and, electrochemical analysis. In general, the best results were obtained for longer polymerization times and positively charged binding sites (which was consistent with a negatively-charged protein under physiological pH, as BSA). Linear responses against BSA concentration ranged from 0.005 to 100 mg/mL, in PBS buffer standard solutions. The sensor was further calibrated in standard solutions that were prepared in synthetic or real urine, and the analytical response became more sensitive and stable. Compared to the literature, the detection capability of the developed device is better than most of the reported electrodes. Overall, the simplicity, low cost and good analytical performance of the BSA SPE device, prepared with positively charged binding positions, seems a suitable approach for practical application in clinical context. Further studies with real samples are required, as well as gathering with electronic-supporting devices to allow on-site readings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid test based on an immunochromatography assay - Determine™ Syphilis TP (Abbott Lab.) for detecting specific antibodies to Treponema pallidum was evaluated against serum samples from patients with clinical, epidemiological and serological diagnosis of syphilis, patients with sexually transmitted disease other than syphilis, and individuals with negative serology for syphilis. The Determine™ test presented the sensitivity of 93.6%, specificity of 92.5%, and positive predictive value and negative predictive value of 95.2% and 93.7%, respectively. One serum sample from patient with recent latent syphilis showed a prozone reaction. Determine™ is a rapid assay, highly specific and easy to perform. This technique obviates the need of equipment and its diagnostic features demonstrate that it may be applicable as an alternative assay for syphilis screening under some emergency conditions or for patients living in remote localities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous experiences have demonstrated the same ABO system and P system antigens in A. lumbricoides extracts and in their hosts. The aim was to show the behavior of an A. lumbricoides extract from an O Group patient against monoclonal antibodies of different specificities. Agglutination Inhibition Tests were carried out facing the extract against monoclonal antibodies (anti A 2.23; anti B 2.54; anti B 2.62; anti AB 2.39 and anti H 2.72) in optimal concentrations. Suspensions of O Group fresh red cells were used as revealing system. The extract only inhibited the agglutination of anti H 2.72 with O erythrocytes. The semiquantitative Agglutination Inhibition Test of the extract was made against two series of anti H 2.72 dilutions by using O Group fresh red cells as revealing system. A difference of five dilutions between the titers of both series has been observed and the presence of H Antigen in the extract has been significantly confirmed. The fact that the extract did not inhibit the agglutination against anti A, anti B and anti AB has corroborated our previous observations about absence of A and B epitopes in A. lumbricoides extracts from O Group patients. The results of the preceding studies and this experience have demonstrated the membrane glycoconjugated importance in A. lumbricoides. They could be involved in molecular mimicry for this parasite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the TEC4SEA research infrastructure created in Portugal to support research, development, and validation of marine technologies. It is a multidisciplinary open platform, capable of supporting research, development, and test of marine robotics, telecommunications, and sensing technologies for monitoring and operating in the ocean environment. Due to the installed research facilities and its privileged geographic location, it allows fast access to deep sea, and can support multidisciplinary research, enabling full validation and evaluation of technological solutions designed for the ocean environment. It is a vertically integrated infrastructure, in the sense that it possesses a set of skills and resources which range from pure conceptual research to field deployment missions, with strong industrial and logistic capacities in the middle tier of prototype production. TEC4SEA is open to the entire scientific and enterprise community, with a free access policy for researchers affiliated with the research units that ensure its maintenance and sustainability. The paper describes the infrastructure in detail, and discusses associated research programs, providing a strategic vision for deep sea research initiatives, within the context of both the Portuguese National Ocean Strategy and European Strategy frameworks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presented at 23rd International Conference on Real-Time Networks and Systems (RTNS 2015). 4 to 6, Nov, 2015, Main Track. Lille, France.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis of American cutaneous leishmaniasis (ACL) is frequently based on clinical and epidemiological data associated with the results of laboratory tests. Some laboratory methods are currently being applied for the diagnosis of ACL, among them the indirect immunofluorescence reaction (IIFR), the Montenegro skin test (MST), histopathological examination, and the polymerase chain reaction (PCR). The performance of these methods varies in a considerable proportion of patients. After the standardization of an immunoenzymatic test (ELISA) for the detection of IgG in the serum of patients with ACL using a crude Leishmania braziliensis antigen, the results obtained were compared to those of other tests routinely used for the diagnosis. The tests revealed the following sensitivity, when analyzed separately: 85% for ELISA IgG, 81% for PCR, 64.4% for MST, 58.1% for IIFR, and 34% for the presence of parasites in the biopsy. ELISA was positive in 75% of patients with ACL presenting a negative MST, in 84.8% of ACL patients with negative skin or mucous biopsies for the presence of the parasite, and in 100% of cases with a negative PCR. Thus, ELISA presented a higher sensitivity than the other tests and was useful as a complementary method for the diagnosis of ACL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herpes simplex virus type 1 (HSV-1) ophthalmic disease is the most common cause of corneal blindness in humans world-wide. Current culture techniques for HSV take several days and commercially available HSV laboratory based diagnostic techniques vary in sensitivity. Our study was conducted to evaluate the use of a quicker and simpler method to herpes ophthalmic diagnosis. Corneal smears were made by firm imprints of infected mouse eyes to glass slides, after smears were fixated with cold acetone, and an indirect immunofluorescence (IIF) method was performed using monoclonal antibodies in a murine model of ophthalmic herpes. Eye swabs from infected mice were inoculated in Vero cells for virus isolation. Cytology and histology of the eye were also performed, using hematoxylin-eosin routine. Mouse eyes were examined by slit-lamp biomicroscopy for evidence of herpetic disease at various times postinoculation. We made a comparative evaluation of sensitivity, specificity and speed of methods for laboratory detection of HSV. Our results indicate that this IIF method is quick, sensitive, specific and can be useful in the diagnosis of ophthalmic herpes as demonstrated in an animal model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nucleic Acid Testing (NAT) as a tool for primary screening of blood donors became a reality in the end of the 1990 decade. We report here the development of an "in-house" RT-PCR method that allows the simultaneous (multiplex) detection of HCV and HIV-RNA in addition to an artificial RNA employed as an external control. This method detects all HIV group M subtypes, plus group N and O, with a detection threshold of 500 IU/mL. After validation, the method replaced p24 Ag testing, in use for blood donation screening since 1996 at our services. From July 2001 to February 2006, 102,469 donations were tested and 41 (0.04%) were found HIV-RNA reactive. One NAT-only reactive donation (antibody non-reactive) was observed, with subsequent seroconversion of the implied donor, giving a yield of 1:102,469. This rate is in contrast to the international experience that reports a detection of approximately 1:600,000 - 1:3,100,000 of isolated HIV-RNA donations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new environmentally friendly Au nanoparticles (Au NPs) synthesis in glycerol by using ultraviolet irradiation and without extra-added stabilizers is described. The synthesis proposed in this work may impact on the non-polluting production of noble nanoparticles with simple chemicals normally found in standard laboratories. These Au NPs were used to modify a carbon paste electrode (CPE) without having to separate them from the reaction medium. This green electrode was used as an electrochemical sensor for the nitrite detection in water. At the optimum conditions the green sensor presented a linear response in the 2.0×10−7–1.5×10−5 M concentration range, a good detection sensitivity (0.268 A L mol−1), and a low detection limit of 2.0×10−7 M of nitrite. The proposed modified green CPE was used to determine nitrite in tap water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: A growing body of evidence shows the prognostic value of oxygen uptake efficiency slope (OUES), a cardiopulmonary exercise test (CPET) parameter derived from the logarithmic relationship between O(2) consumption (VO(2)) and minute ventilation (VE) in patients with chronic heart failure (CHF). OBJECTIVE: To evaluate the prognostic value of a new CPET parameter - peak oxygen uptake efficiency (POUE) - and to compare it with OUES in patients with CHF. METHODS: We prospectively studied 206 consecutive patients with stable CHF due to dilated cardiomyopathy - 153 male, aged 53.3±13.0 years, 35.4% of ischemic etiology, left ventricular ejection fraction 27.7±8.0%, 81.1% in sinus rhythm, 97.1% receiving ACE-Is or ARBs, 78.2% beta-blockers and 60.2% spironolactone - who performed a first maximal symptom-limited treadmill CPET, using the modified Bruce protocol. In 33% of patients an cardioverter-defibrillator (ICD) or cardiac resynchronization therapy device (CRT-D) was implanted during follow-up. Peak VO(2), percentage of predicted peak VO(2), VE/VCO(2) slope, OUES and POUE were analyzed. OUES was calculated using the formula VO(2) (l/min) = OUES (log(10)VE) + b. POUE was calculated as pVO(2) (l/min) / log(10)peakVE (l/min). Correlation coefficients between the studied parameters were obtained. The prognosis of each variable adjusted for age was evaluated through Cox proportional hazard models and R2 percent (R2%) and V index (V6) were used as measures of the predictive accuracy of events of each of these variables. Receiver operating characteristic (ROC) curves from logistic regression models were used to determine the cut-offs for OUES and POUE. RESULTS: pVO(2): 20.5±5.9; percentage of predicted peak VO(2): 68.6±18.2; VE/VCO(2) slope: 30.6±8.3; OUES: 1.85±0.61; POUE: 0.88±0.27. During a mean follow-up of 33.1±14.8 months, 45 (21.8%) patients died, 10 (4.9%) underwent urgent heart transplantation and in three patients (1.5%) a left ventricular assist device was implanted. All variables proved to be independent predictors of this combined event; however, VE/VCO2 slope was most strongly associated with events (HR 11.14). In this population, POUE was associated with a higher risk of events than OUES (HR 9.61 vs. 7.01), and was also a better predictor of events (R2: 28.91 vs. 22.37). CONCLUSION: POUE was more strongly associated with death, urgent heart transplantation and implantation of a left ventricular assist device and proved to be a better predictor of events than OUES. These results suggest that this new parameter can increase the prognostic value of CPET in patients with CHF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thirty Candida albicans isolated from oral candidosis patients and 30 C. albicans isolated from control individuals were studied. In vitro susceptibility tests were performed for amphotericin B, fluconazole, 5-flucytosine and itraconazole through the Clinical and Laboratorial Standards Institute (CLSI) reference method and E test system. The results obtained were analyzed and compared. MIC values were similar for the strains isolated from oral candidosis patients and control individuals. The agreement rate for the two methods was 66.67% for amphotericin B, 53.33% for fluconazole, 65% for flucytosine and 45% for itraconazole. According to our data, E test method could be an alternative to trial routine susceptibility testing due to its simplicity. However, it can not be considered a substitute for the CLSI reference method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the behaviour of two structural adhesives modified with thermally expandable particles (TEPs) was investigated as a preliminary study for further investigations on the potential of TEPs in adhesive joints. Tensile bulk tests were performed to get the tensile properties of the adhesives and TEPs-modified adhesives. In order to determine the expansion temperature of the particles while encapsulated in these particular adhesive systems, the variation of the volume of adhesive samples modified with different TEPs concentration as a function of temperature was measured. Further, the possibility of any chemical interactions between TEPs and adhesives matrix in the TEPs-modified specimens was verified by a Fourier transform infrared spectroscopy analysis. Finally, the fracture surfaces of the unmodified and TEPs-modified specimens, as well as the dispersion and the morphology of the particles, were examined by a scanning electron microscopy analysis. It was found that the stiffness of the TEPs-modified adhesives is not affected by incorporation of TEPs in the adhesives matrix, while the tensile yield strength decreased by increasing the wt% TEPs content. In applications of such particular materials (TEPs-modified adhesives), the temperature should be controlled to stay between 90°C and 120°C in order to obtain the highest expansion ratio. At a lower temperature, not all the particles will expand, and above, the TEPs will deteriorate and as a result the TEPs-modified adhesives will deteriorate.