990 resultados para instantaneous frequency measurement
Resumo:
Abstract : The occupational health risk involved with handling nanoparticles is the probability that a worker will experience an adverse health effect: this is calculated as a function of the worker's exposure relative to the potential biological hazard of the material. Addressing the risks of nanoparticles requires therefore knowledge on occupational exposure and the release of nanoparticles into the environment as well as toxicological data. However, information on exposure is currently not systematically collected; therefore this risk assessment lacks quantitative data. This thesis aimed at, first creating the fundamental data necessary for a quantitative assessment and, second, evaluating methods to measure the occupational nanoparticle exposure. The first goal was to determine what is being used where in Swiss industries. This was followed by an evaluation of the adequacy of existing measurement methods to assess workplace nanopaiticle exposure to complex size distributions and concentration gradients. The study was conceived as a series of methodological evaluations aimed at better understanding nanoparticle measurement devices and methods. lt focused on inhalation exposure to airborne particles, as respiration is considered to be the most important entrance pathway for nanoparticles in the body in terms of risk. The targeted survey (pilot study) was conducted as a feasibility study for a later nationwide survey on the handling of nanoparticles and the applications of specific protection means in industry. The study consisted of targeted phone interviews with health and safety officers of Swiss companies that were believed to use or produce nanoparticles. This was followed by a representative survey on the level of nanoparticle usage in Switzerland. lt was designed based on the results of the pilot study. The study was conducted among a representative selection of clients of the Swiss National Accident Insurance Fund (SUVA), covering about 85% of Swiss production companies. The third part of this thesis focused on the methods to measure nanoparticles. Several pre- studies were conducted studying the limits of commonly used measurement devices in the presence of nanoparticle agglomerates, This focus was chosen, because several discussions with users and producers of the measurement devices raised questions about their accuracy measuring nanoparticle agglomerates and because, at the same time, the two survey studies revealed that such powders are frequently used in industry. The first preparatory experiment focused on the accuracy of the scanning mobility particle sizer (SMPS), which showed an improbable size distribution when measuring powders of nanoparticle agglomerates. Furthermore, the thesis includes a series of smaller experiments that took a closer look at problems encountered with other measurement devices in the presence of nanoparticle agglomerates: condensation particle counters (CPC), portable aerosol spectrometer (PAS) a device to estimate the aerodynamic diameter, as well as diffusion size classifiers. Some initial feasibility tests for the efficiency of filter based sampling and subsequent counting of carbon nanotubes (CNT) were conducted last. The pilot study provided a detailed picture of the types and amounts of nanoparticles used and the knowledge of the health and safety experts in the companies. Considerable maximal quantities (> l'000 kg/year per company) of Ag, Al-Ox, Fe-Ox, SiO2, TiO2, and ZnO (mainly first generation particles) were declared by the contacted Swiss companies, The median quantity of handled nanoparticles, however, was 100 kg/year. The representative survey was conducted by contacting by post mail a representative selection of l '626 SUVA-clients (Swiss Accident Insurance Fund). It allowed estimation of the number of companies and workers dealing with nanoparticles in Switzerland. The extrapolation from the surveyed companies to all companies of the Swiss production sector suggested that l'309 workers (95%-confidence interval l'073 to l'545) of the Swiss production sector are potentially exposed to nanoparticles in 586 companies (145 to l'027). These numbers correspond to 0.08% (0.06% to 0.09%) of all workers and to 0.6% (0.2% to 1.1%) of companies in the Swiss production sector. To measure airborne concentrations of sub micrometre-sized particles, a few well known methods exist. However, it was unclear how well the different instruments perform in the presence of the often quite large agglomerates of nanostructured materials. The evaluation of devices and methods focused on nanoparticle agglomerate powders. lt allowed the identification of the following potential sources of inaccurate measurements at workplaces with considerable high concentrations of airborne agglomerates: - A standard SMPS showed bi-modal particle size distributions when measuring large nanoparticle agglomerates. - Differences in the range of a factor of a thousand were shown between diffusion size classifiers and CPC/SMPS. - The comparison between CPC/SMPS and portable aerosol Spectrometer (PAS) was much better, but depending on the concentration, size or type of the powders measured, the differences were still of a high order of magnitude - Specific difficulties and uncertainties in the assessment of workplaces were identified: the background particles can interact with particles created by a process, which make the handling of background concentration difficult. - Electric motors produce high numbers of nanoparticles and confound the measurement of the process-related exposure. Conclusion: The surveys showed that nanoparticles applications exist in many industrial sectors in Switzerland and that some companies already use high quantities of them. The representative survey demonstrated a low prevalence of nanoparticle usage in most branches of the Swiss industry and led to the conclusion that the introduction of applications using nanoparticles (especially outside industrial chemistry) is only beginning. Even though the number of potentially exposed workers was reportedly rather small, it nevertheless underscores the need for exposure assessments. Understanding exposure and how to measure it correctly is very important because the potential health effects of nanornaterials are not yet fully understood. The evaluation showed that many devices and methods of measuring nanoparticles need to be validated for nanoparticles agglomerates before large exposure assessment studies can begin. Zusammenfassung : Das Gesundheitsrisiko von Nanopartikel am Arbeitsplatz ist die Wahrscheinlichkeit dass ein Arbeitnehmer einen möglichen Gesundheitsschaden erleidet wenn er diesem Stoff ausgesetzt ist: sie wird gewöhnlich als Produkt von Schaden mal Exposition gerechnet. Für eine gründliche Abklärung möglicher Risiken von Nanomaterialien müssen also auf der einen Seite Informationen über die Freisetzung von solchen Materialien in die Umwelt vorhanden sein und auf der anderen Seite solche über die Exposition von Arbeitnehmenden. Viele dieser Informationen werden heute noch nicht systematisch gesarnmelt und felilen daher für Risikoanalysen, Die Doktorarbeit hatte als Ziel, die Grundlagen zu schaffen für eine quantitative Schatzung der Exposition gegenüber Nanopartikel am Arbeitsplatz und die Methoden zu evaluieren die zur Messung einer solchen Exposition nötig sind. Die Studie sollte untersuchen, in welchem Ausmass Nanopartikel bereits in der Schweizer Industrie eingesetzt werden, wie viele Arbeitnehrner damit potentiel] in Kontakt komrrien ob die Messtechnologie für die nötigen Arbeitsplatzbelastungsmessungen bereits genügt, Die Studie folcussierte dabei auf Exposition gegenüber luftgetragenen Partikel, weil die Atmung als Haupteintrittspforte iïlr Partikel in den Körper angesehen wird. Die Doktorarbeit besteht baut auf drei Phasen auf eine qualitative Umfrage (Pilotstudie), eine repräsentative, schweizerische Umfrage und mehrere technische Stndien welche dem spezitischen Verständnis der Mëglichkeiten und Grenzen einzelner Messgeräte und - teclmikeri dienen. Die qualitative Telephonumfrage wurde durchgeführt als Vorstudie zu einer nationalen und repräsentativen Umfrage in der Schweizer Industrie. Sie zielte auf Informationen ab zum Vorkommen von Nanopartikeln, und den angewendeten Schutzmassnahmen. Die Studie bestand aus gezielten Telefoninterviews mit Arbeit- und Gesundheitsfachpersonen von Schweizer Unternehmen. Die Untemehmen wurden aufgrund von offentlich zugànglichen lnformationen ausgewählt die darauf hinwiesen, dass sie mit Nanopartikeln umgehen. Der zweite Teil der Dolctorarbeit war die repräsentative Studie zur Evalniernng der Verbreitnng von Nanopaitikelanwendungen in der Schweizer lndustrie. Die Studie baute auf lnformationen der Pilotstudie auf und wurde mit einer repräsentativen Selektion von Firmen der Schweizerischen Unfall Versicherungsanstalt (SUVA) durchgeüihxt. Die Mehrheit der Schweizerischen Unternehmen im lndustrieselctor wurde damit abgedeckt. Der dritte Teil der Doktorarbeit fokussierte auf die Methodik zur Messung von Nanopartikeln. Mehrere Vorstudien wurden dnrchgefîihrt, um die Grenzen von oft eingesetzten Nanopartikelmessgeräten auszuloten, wenn sie grösseren Mengen von Nanopartikel Agglomeraten ausgesetzt messen sollen. Dieser F okns wurde ans zwei Gründen gewählt: weil mehrere Dislcussionen rnit Anwendem und auch dem Produzent der Messgeràte dort eine Schwachstelle vermuten liessen, welche Zweifel an der Genauigkeit der Messgeräte aufkommen liessen und weil in den zwei Umfragestudien ein häufiges Vorkommen von solchen Nanopartikel-Agglomeraten aufgezeigt wurde. i Als erstes widmete sich eine Vorstndie der Genauigkeit des Scanning Mobility Particle Sizer (SMPS). Dieses Messgerät zeigte in Präsenz von Nanopartikel Agglorneraten unsinnige bimodale Partikelgrössenverteilung an. Eine Serie von kurzen Experimenten folgte, welche sich auf andere Messgeräte und deren Probleme beim Messen von Nanopartikel-Agglomeraten konzentrierten. Der Condensation Particle Counter (CPC), der portable aerosol spectrometer (PAS), ein Gerät zur Schàtzung des aerodynamischen Durchniessers von Teilchen, sowie der Diffusion Size Classifier wurden getestet. Einige erste Machbarkeitstests zur Ermittlnng der Effizienz von tilterbasierter Messung von luftgetragenen Carbon Nanotubes (CNT) wnrden als letztes durchgeiührt. Die Pilotstudie hat ein detailliiertes Bild der Typen und Mengen von genutzten Nanopartikel in Schweizer Unternehmen geliefert, und hat den Stand des Wissens der interviewten Gesundheitsschntz und Sicherheitsfachleute aufgezeigt. Folgende Typen von Nanopaitikeln wurden von den kontaktierten Firmen als Maximalmengen angegeben (> 1'000 kg pro Jahr / Unternehrnen): Ag, Al-Ox, Fe-Ox, SiO2, TiO2, und ZnO (hauptsächlich Nanopartikel der ersten Generation). Die Quantitäten von eingesetzten Nanopartikeln waren stark verschieden mit einem ein Median von 100 kg pro Jahr. ln der quantitativen Fragebogenstudie wurden l'626 Unternehmen brieflich kontaktiert; allesamt Klienten der Schweizerischen Unfallversicherringsanstalt (SUVA). Die Resultate der Umfrage erlaubten eine Abschätzung der Anzahl von Unternehmen und Arbeiter, welche Nanopartikel in der Schweiz anwenden. Die Hochrechnung auf den Schweizer lndnstriesektor hat folgendes Bild ergeben: ln 586 Unternehmen (95% Vertrauensintervallz 145 bis 1'027 Unternehmen) sind 1'309 Arbeiter potentiell gegenüber Nanopartikel exponiert (95%-Vl: l'073 bis l'545). Diese Zahlen stehen für 0.6% der Schweizer Unternehmen (95%-Vl: 0.2% bis 1.1%) und 0.08% der Arbeiternehmerschaft (95%-V1: 0.06% bis 0.09%). Es gibt einige gut etablierte Technologien um die Luftkonzentration von Submikrometerpartikel zu messen. Es besteht jedoch Zweifel daran, inwiefern sich diese Technologien auch für die Messurrg von künstlich hergestellten Nanopartikeln verwenden lassen. Aus diesem Grund folcussierten die vorbereitenden Studien für die Arbeitsplatzbeurteilnngen auf die Messung von Pulverri, welche Nan0partike1-Agg10merate enthalten. Sie erlaubten die ldentifikation folgender rnöglicher Quellen von fehlerhaften Messungen an Arbeitsplätzen mit erhöhter Luft-K0nzentrati0n von Nanopartikel Agglomeratenz - Ein Standard SMPS zeigte eine unglaubwürdige bimodale Partikelgrössenverteilung wenn er grössere Nan0par'til<e1Agg10merate gemessen hat. - Grosse Unterschiede im Bereich von Faktor tausend wurden festgestellt zwischen einem Diffusion Size Classiîier und einigen CPC (beziehungsweise dem SMPS). - Die Unterschiede zwischen CPC/SMPS und dem PAS waren geringer, aber abhängig von Grosse oder Typ des gemessenen Pulvers waren sie dennoch in der Grössenordnung von einer guten Grössenordnung. - Spezifische Schwierigkeiten und Unsicherheiten im Bereich von Arbeitsplatzmessungen wurden identitiziert: Hintergrundpartikel können mit Partikeln interagieren die während einem Arbeitsprozess freigesetzt werden. Solche Interaktionen erschweren eine korrekte Einbettung der Hintergrunds-Partikel-Konzentration in die Messdaten. - Elektromotoren produzieren grosse Mengen von Nanopartikeln und können so die Messung der prozessbezogenen Exposition stören. Fazit: Die Umfragen zeigten, dass Nanopartikel bereits Realitàt sind in der Schweizer Industrie und dass einige Unternehmen bereits grosse Mengen davon einsetzen. Die repräsentative Umfrage hat diese explosive Nachricht jedoch etwas moderiert, indem sie aufgezeigt hat, dass die Zahl der Unternehmen in der gesamtschweizerischen Industrie relativ gering ist. In den meisten Branchen (vor allem ausserhalb der Chemischen Industrie) wurden wenig oder keine Anwendungen gefunden, was schliessen last, dass die Einführung dieser neuen Technologie erst am Anfang einer Entwicklung steht. Auch wenn die Zahl der potentiell exponierten Arbeiter immer noch relativ gering ist, so unterstreicht die Studie dennoch die Notwendigkeit von Expositionsmessungen an diesen Arbeitsplätzen. Kenntnisse um die Exposition und das Wissen, wie solche Exposition korrekt zu messen, sind sehr wichtig, vor allem weil die möglichen Auswirkungen auf die Gesundheit noch nicht völlig verstanden sind. Die Evaluation einiger Geräte und Methoden zeigte jedoch, dass hier noch Nachholbedarf herrscht. Bevor grössere Mess-Studien durgefîihrt werden können, müssen die Geräte und Methodem für den Einsatz mit Nanopartikel-Agglomeraten validiert werden.
Resumo:
The purpose of this study was to adjust equations that establish relationships between rainfall events with different duration and data from weather stations in the state of Santa Catarina, Brazil. In this study, the relationships between different duration heavy rainfalls from 13 weather stations of Santa Catarina were analyzed. From series of maximum annual rainfalls, and using the Gumbel-Chow distribution, the maximum rainfall for durations between 5 min and 24 h were estimated considering return periods from 2 to 100 years. The data fit to the Gumbel-Chow model was verified by the Kolmogorov-Smirnov test at 5 % significance. The coefficients of Bell's equation were adjusted to estimate the relationship between rainfall duration t (min) and the return period T (y) in relation to the maximum rainfall with a duration of 1 hour and a 10 year return period. Likewise, the coefficients of Bell's equation were adjusted based on the maximum rainfall with a duration of 1 day and a 10 year return period. The results showed that these relationships are viable to estimate short-duration rainfall events at locations where there are no rainfall records.
Resumo:
We present a Bayesian approach for estimating the relative frequencies of multi-single nucleotide polymorphism (SNP) haplotypes in populations of the malaria parasite Plasmodium falciparum by using microarray SNP data from human blood samples. Each sample comes from a malaria patient and contains one or several parasite clones that may genetically differ. Samples containing multiple parasite clones with different genetic markers pose a special challenge. The situation is comparable with a polyploid organism. The data from each blood sample indicates whether the parasites in the blood carry a mutant or a wildtype allele at various selected genomic positions. If both mutant and wildtype alleles are detected at a given position in a multiply infected sample, the data indicates the presence of both alleles, but the ratio is unknown. Thus, the data only partially reveals which specific combinations of genetic markers (i.e. haplotypes across the examined SNPs) occur in distinct parasite clones. In addition, SNP data may contain errors at non-negligible rates. We use a multinomial mixture model with partially missing observations to represent this data and a Markov chain Monte Carlo method to estimate the haplotype frequencies in a population. Our approach addresses both challenges, multiple infections and data errors.
Resumo:
We have designed and built an experimental device, which we called a "thermoelectric bridge." Its primary purpose is simultaneous measurement of the relative Peltier and Seebeck coefficients. The systematic errors for both coefficients are equal with this device and manipulation is not necessary between the measurement of one coefficient and the other. Thus, this device is especially suitable for verifying their linear relation postulated by Lord Kelvin. Also, simultaneous measurement of thermal conductivity is described in the text. A sample is made up of the couple nickel¿platinum, taking measurements in the range of ¿20¿60°C and establishing the dependence of each coefficient with temperature, with nearly equal random errors ±0.2%, and systematic errors estimated at ¿0.5%. The aforementioned Kelvin relation is verified in this range from these results, proving that the behavioral deviations are ¿0.3% contained in the uncertainty ±0.5% caused by the propagation of errors
Resumo:
We investigate within mean-field theory the influence of a one-dimensional optical lattice and of trapped degenerate fermions on the critical rotational frequency for vortex line creation in a Bose-Einstein condensate. We consider laser intensities of the lattice such that quantum coherence across the condensate is ensured. We find a sizable decrease of the thermodynamic critical frequency for vortex nucleation with increasing applied laser strength and suggest suitable parameters for experimental observation. Since 87Rb-40K mixtures may undergo collapse, we analyze the related question of how the optical lattice affects the mechanical stability of the system.
Resumo:
The evolution of continuous traits is the central component of comparative analyses in phylogenetics, and the comparison of alternative models of trait evolution has greatly improved our understanding of the mechanisms driving phenotypic differentiation. Several factors influence the comparison of models, and we explore the effects of random errors in trait measurement on the accuracy of model selection. We simulate trait data under a Brownian motion model (BM) and introduce different magnitudes of random measurement error. We then evaluate the resulting statistical support for this model against two alternative models: Ornstein-Uhlenbeck (OU) and accelerating/decelerating rates (ACDC). Our analyses show that even small measurement errors (10%) consistently bias model selection towards erroneous rejection of BM in favour of more parameter-rich models (most frequently the OU model). Fortunately, methods that explicitly incorporate measurement errors in phylogenetic analyses considerably improve the accuracy of model selection. Our results call for caution in interpreting the results of model selection in comparative analyses, especially when complex models garner only modest additional support. Importantly, as measurement errors occur in most trait data sets, we suggest that estimation of measurement errors should always be performed during comparative analysis to reduce chances of misidentification of evolutionary processes.
Resumo:
We present a high‐resolution electron microscopy study of the microstructure of boron nitride thin films grown on silicon (100) by radio‐frequency plasma‐assisted chemical vapor deposition using B2H6 (1% in H2) and NH3 gases. Well‐adhered boron nitride films grown on the grounded electrode show a highly oriented hexagonal structure with the c‐axis parallel to the substrate surface throughout the film, without any interfacial amorphous layer. We ascribed this textured growth to an etching effect of atomic hydrogen present in the gas discharge. In contrast, films grown on the powered electrode, with compressive stress induced by ion bombardment, show a multilayered structure as observed by other authors, composed of an amorphous layer, a hexagonal layer with the c‐axis parallel to the substrate surface and another layer oriented at random
Resumo:
At seismic frequencies, wave-induced fluid flow is a major cause of P-wave attenuation in partially saturated porous rocks. Attenuation is of great importance for the oil industry in the interpretation of seismic field data. Here, the effects on P-wave attenuation resulting from changes in oil saturation are studied for media with coexisting water, oil, and gas. For that, creep experiments are numerically simulated by solving Biot's equations for consolidation of poroelastic media with the finite-element method. The experiments yield time-dependent stress?strain relations that are used to calculate the complex P-wave modulus from which frequency-dependent P-wave attenuation is determined. The models are layered media with periodically alternating triplets of layers. Models consisting of triplets of layers having randomly varying layer thicknesses are also considered. The layers in each triplet are fully saturated with water, oil, and gas. The layer saturated with water has lower porosity and permeability than the layers saturated with oil and gas. These models represent hydrocarbon reservoirs in which water is the wetting fluid preferentially saturating regions of lower porosity. The results from the numerical experiments showed that increasing oil saturation, connected to a decrease in gas saturation, resulted in a significant increase of attenuation at low frequencies (lower than 2 Hz). Furthermore, replacing the oil with water resulted in a distinguishable behavior of the frequency-dependent attenuation. These results imply that, according to the physical mechanism of wave-induced fluid flow, frequency-dependent attenuation in media saturated with water, oil, and gas is a potential indicator of oil saturation.
Resumo:
Detailed knowledge on water percolation into the soil in irrigated areas is fundamental for solving problems of drainage, pollution and the recharge of underground aquifers. The aim of this study was to evaluate the percolation estimated by time-domain-reflectometry (TDR) in a drainage lysimeter. We used Darcy's law with K(θ) functions determined by field and laboratory methods and by the change in water storage in the soil profile at 16 points of moisture measurement at different time intervals. A sandy clay soil was saturated and covered with plastic sheet to prevent evaporation and an internal drainage trial in a drainage lysimeter was installed. The relationship between the observed and estimated percolation values was evaluated by linear regression analysis. The results suggest that percolation in the field or laboratory can be estimated based on continuous monitoring with TDR, and at short time intervals, of the variations in soil water storage. The precision and accuracy of this approach are similar to those of the lysimeter and it has advantages over the other evaluated methods, of which the most relevant are the possibility of estimating percolation in short time intervals and exemption from the predetermination of soil hydraulic properties such as water retention and hydraulic conductivity. The estimates obtained by the Darcy-Buckingham equation for percolation levels using function K(θ) predicted by the method of Hillel et al. (1972) provided compatible water percolation estimates with those obtained in the lysimeter at time intervals greater than 1 h. The methods of Libardi et al. (1980), Sisson et al. (1980) and van Genuchten (1980) underestimated water percolation.
Resumo:
In this study, we present a detailed structural characterization by means of transmission electron microscopy and Raman spectroscopy of polymorphous silicon (pm-Si:H) thin films deposited using radio-frequency dust-forming plasmas of SiH4 diluted in Ar. Square-wave modulation of the plasma and gas temperature was varied to obtain films with different nanostructures. Transmission electron microscopy and electron diffraction have shown the presence of Si crystallites of around 2 nm in the pm-Si:H films, which are related to the nanoparticles formed in the plasma gas phase coming from their different growth stages, named particle nucleation and coagulation. Raman scattering has proved the role of the film nanostructure in the crystallization process induced ¿in situ¿ by laser heating.
Resumo:
The substrate tuning technique was applied to a radio frequency magnetron sputtering system to obtain a variable substrate bias without an additional source. The dependence of the substrate bias on the value of the external impedance was studied for different values of chamber pressure, gas composition and rf input power. A qualitative explanation of the results is given, based on a simple model, and the role of the stray capacitance is clearly disclosed. Langmuir probe measurements show that this system allows independent control of the ion flux and the ion energy bombarding the growing film. For an argon flow rate of 2.8 sccm and a radio frequency power of 300 W (intermediate values of the range studied) the ion flux incident on the substrate was 1.3 X 1020-m-2-s-1. The maximum ion energy available in these conditions can be varied in the range 30-150 eV. As a practical application of the technique, BN thin films were deposited under different ion bombardment conditions. An ion energy threshold of about 80 eV was found, below which only the hexagonal phase was present in the films, while for higher energies both hexagonal and cubic phase were present. A cubic content of about 60% was found for an ion energy of 120 V.
Resumo:
The influence of radio frequency (rf) power and pressure on deposition rate and structural properties of hydrogenated amorphous silicon (a-Si:H) thin films, prepared by rf glow discharge decomposition of silane, have been studied by phase modulated ellipsometry and Fourier transform infrared spectroscopy. It has been found two pressure regions separated by a threshold value around 20 Pa where the deposition rate increases suddenly. This behavior is more marked as rf power rises and reflects the transition between two rf discharges regimes. The best quality films have been obtained at low pressure and at low rf power but with deposition rates below 0.2 nm/s. In the high pressure region, the enhancement of deposition rate as rf power increases first gives rise to a reduction of film density and an increase of content of hydrogen bonded in polyhydride form because of plasma polymerization reactions. Further rise of rf power leads to a decrease of polyhydride bonding and the material density remains unchanged, thus allowing the growth of a-Si:H films at deposition rates above 1 nm/s without any important detriment of material quality. This overcoming of deposition rate limitation has been ascribed to the beneficial effects of ion bombardment on the a-Si:H growing surface by enhancing the surface mobility of adsorbed reactive species and by eliminating hydrogen bonded in polyhydride configurations.