897 resultados para evaluation studies group


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several hypnosis monitoring systems based on the processed electroencephalogram (EEG) have been developed for use during general anesthesia. The assessment of the analgesic component (antinociception) of general anesthesia is an emerging field of research. This study investigated the interaction of hypnosis and antinociception, the association of several physiological variables with the degree of intraoperative nociception, and aspects of EEG Bispectral Index Scale (BIS) monitoring during general anesthesia. In addition, EEG features and heart rate (HR) responses during desflurane and sevoflurane anesthesia were compared. A propofol bolus of 0.7 mg/kg was more effective than an alfentanil bolus of 0.5 mg in preventing the recurrence of movement responses during uterine dilatation and curettage (D C) after a propofol-alfentanil induction, combined with nitrous oxide (N2O). HR and several HR variability-, frontal electromyography (fEMG)-, pulse plethysmography (PPG)-, and EEG-derived variables were associated with surgery-induced movement responses. Movers were discriminated from non-movers mostly by the post-stimulus values per se or normalized with respect to the pre-stimulus values. In logistic regression analysis, the best classification performance was achieved with the combination of normalized fEMG power and HR during D C (overall accuracy 81%, sensitivity 53%, specificity 95%), and with the combination of normalized fEMG-related response entropy, electrocardiography (ECG) R-to-R interval (RRI), and PPG dicrotic notch amplitude during sevoflurane anesthesia (overall accuracy 96%, sensitivity 90%, specificity 100%). ECG electrode impedances after alcohol swab skin pretreatment alone were higher than impedances of designated EEG electrodes. The BIS values registered with ECG electrodes were higher than those registered simultaneously with EEG electrodes. No significant difference in the time to home-readiness after isoflurane-N2O or sevoflurane-N2O anesthesia was found, when the administration of the volatile agent was guided by BIS monitoring. All other early and intermediate recovery parameters were also similar. Transient epileptiform EEG activity was detected in eight of 15 sevoflurane patients during a rapid increase in the inspired volatile concentration, and in none of the 16 desflurane patients. The observed transient EEG changes did not adversely affect the recovery of the patients. Following the rapid increase in the inhaled desflurane concentration, HR increased transiently, reaching its maximum in two minutes. In the sevoflurane group, the increase was slower and more subtle. In conclusion, desflurane may be a safer volatile agent than sevoflurane in patients with a lowered seizure threshold. The tachycardia induced by a rapid increase in the inspired desflurane concentration may present a risk for patients with heart disease. Designated EEG electrodes may be superior to ECG electrodes in EEG BIS monitoring. When the administration of isoflurane or sevoflurane is adjusted to maintain BIS values at 50-60 in healthy ambulatory surgery patients, the speed and quality of recovery are similar after both isoflurane-N2O and sevoflurane-N2O anesthesia. When anesthesia is maintained by the inhalation of N2O and bolus doses of propofol and alfentanil in healthy unparalyzed patients, movement responses may be best avoided by ensuring a relatively deep hypnotic level with propofol. HR/RRI, fEMG, and PPG dicrotic notch amplitude are potential indicators of nociception during anesthesia, but their performance needs to be validated in future studies. Combining information from different sources may improve the discrimination of the level of nociception.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aromatic aldehydes and aryl isocyanates do not react at room temperature. However, we have shown for the first time that in the presence of catalytic amounts of group(IV) n-butoxide, they undergo metathesis at room temperature to produce imines with the extrusion of carbon dioxide. The mechanism of action has been investigated by a study of stoichiometric reactions. The insertion of aryl isocyanates into the metal n-butoxide occurs very rapidly. Reaction of the insertion product with the aldehyde is responsible for the metathesis. Among the n-butoxides of group(IV) metals, Ti((OBu)-Bu-n)(4) (8aTi) was found to be more efficient than Zr((OBu)-Bu-n)(4) (8aZr) and Hf((OBu)-Bu-n)(4) (8aHf) in carrying out metathesis. The surprisingly large difference in the metathetic activity of these alkoxides has been probed computationally using model complexes Ti(OMe)(4) (8bTi), Zr(OMe)(4) (8bZr) and Hf(OMe)(4) (8bHf) at the B3LYP/LANL2DZ level of theory. These studies indicate that the insertion product formed by Zr and Hf are extremely stable compared to that formed by Ti. This makes subsequent reaction of Zr and Hf complexes unfavorable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

3C resonances of carbonyl and methyl groups in amides are shifted down-field on interaction with alkali and alkaline earth metal salts. The magnitude of the shift depends on the ionic potential of the cation. Ions like Li+ bind to the amide carbonyl group both in neat amide solutions as well as in concentrated salt solutions in water.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The 270 MHz 1H n.m.r. spectrum of benzyloxycarbonyl-Pro-N-methylamide in CDCl3 is exchange broadened at 293° K. Spectral lines due to two species are frozen out at 253° K and a dynamically averaged spectrum is obtained at 323° K. A selective broadening of the Cβ and Cγ resonances in the 13C n.m.r. spectrum is observed at 253° K, with a splitting of the Cβ and Cγ resonances into a pair of lines of unequal intensity. A similar broadening of Cβ and Cγ peaks is also detected in pivaloyl-Pro-N-methylamide where cis-trans interconversion about the imide bond is precluded by the bulky t-butyl group. The rate process is thus attributed to rotation about the Cα-CO bond (ψ) and a barrier (ΔG#) of 14kcal mol-1 is estimated. 13C n.m.r. data for pivaloyl-Pro-N-methylamide in a number of solvents is presented and the differences in the Cβ and Cγ chemical shifts are interpreted in terms of rotational isomerism about the Cα-CO bond.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The benzylic methylene protons in a large number of benzyloxycarbonyl alpha-aminoisobutyric acid (Z-Aib) containing peptides, show chemical shift nonequivalence. The magnitude of the geminal nonequivalence is correlated with the involvement of the urethane carbonyl group, in an intramolecular hydrogen bond. Studies of the model compounds Z-Aib-Aib-Ala-NHMe, and Z-Aib-Aib-Aib-Pro-OMe clearly establish the presence of intramolecular hydrogen bonds, involving the urethane CO group. In both compounds marked anisochrony of the benzylic methylene protons is demonstrated. In Z-Aib-Aib-Pro-OMe, where a 4 leads to 1 hydrogen bonded beta-turn is not possible, the benzylic-CH2-protons appear as a singlet in CDCl3 and have a very small chemical shift difference in (CD3)2SO. The observation of such nonequivalence is of value in establishing whether the amino terminal Aib-Pro beta-turn is retained in large peptide-fragments of alamethicin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pivaloyl-L-Pro-Aib-N-methylamihdaes been shown to possess one intramolecular hydrogen bond in (CD&SO solution, by 'H-nmr methods, suggesting the existence of p-turns, with Pro-Aib as the corner residues. Theoretical conformational analysis suggests that Type II P-turn conformations are about 2 kcal mol-' more stable than Type 111 structures. A crystallographic study has established the Type I1 /%turn in the solid state. The molecule crystallizes in the space group P21 with a = 5.865 8, b = 11.421 A, c = 12.966 A, /3 = 97.55", and 2 = 2. The structure has been refined to a final R value of 0.061. The Type I1 p-turn conformation is stabilized by an intramolecular 4 - 1 hydrogen bond between the methylamide NH and the pivaloyl CO group. The conformational angles are @pro= -57.8", $pro = 139.3', @Aib = 61.4', and $Ajb = 25.1'. The Type 11 /%turn conformation for Pro-Aib in this peptide is compared with the Type I11 structures observed for the same segment in larger peptides.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main obstacle for the application of high quality diamond-like carbon (DLC) coatings has been the lack of adhesion to the substrate as the coating thickness is increased. The aim of this study was to improve the filtered pulsed arc discharge (FPAD) method. With this method it is possible to achieve high DLC coating thicknesses necessary for practical applications. The energy of the carbon ions was measured with an optoelectronic time-of-flight method. An in situ cathode polishing system used for stabilizing the process yield and the carbon ion energies is presented. Simultaneously the quality of the coatings can be controlled. To optimise the quality of the deposition process a simple, fast and inexpensive method using silicon wafers as test substrates was developed. This method was used for evaluating the suitability of a simplified arc-discharge set-up for the deposition of the adhesion layer of DLC coatings. A whole new group of materials discovered by our research group, the diamond-like carbon polymer hybrid (DLC-p-h) coatings, is also presented. The parent polymers used in these novel coatings were polydimethylsiloxane (PDMS) and polytetrafluoroethylene (PTFE). The energy of the plasma ions was found to increase when the anode-cathode distance and the arc voltage were increased. A constant deposition rate for continuous coating runs was obtained with an in situ cathode polishing system. The novel DLC-p-h coatings were found to be water and oil repellent and harder than any polymers. The lowest sliding angle ever measured from a solid surface, 0.15 ± 0.03°, was measured on a DLC-PDMS-h coating. In the FPAD system carbon ions can be accelerated to high energies (≈ 1 keV) necessary for the optimal adhesion (the substrate is broken in the adhesion and quality test) of ultra thick (up to 200 µm) DLC coatings by increasing the anode-cathode distance and using high voltages (up to 4 kV). An excellent adhesion can also be obtained with the simplified arc-discharge device. To maintain high process yield (5µm/h over a surface area of 150 cm2) and to stabilize the carbon ion energies and the high quality (sp3 fraction up to 85%) of the resulting coating, an in situ cathode polishing system must be used. DLC-PDMS-h coating is the superior candidate coating material for anti-soiling applications where also hardness is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this series of studies was to evaluate the biocompatibility of poly (ortho) ester (POE), copolymer of ε-caprolactone and D,L-lactide [P (ε-CL/DL-LA)] and the composite of P(ε-CL/DL-LA) and tricalciumphosphate (TCP) as bone filling material in bone defects. Tissue reactions and resorption times of two solid POE-implants (POE 140 and POE 46) with different methods of sterilization (gamma- and ethylene oxide sterilization), P(ε-CL/DL-LA)(40/60 w/w) in paste form and 50/50 w/w composite of 40/60 w/w P(ε-CL/DL-LA) and TCP and 27/73 w/w composite of 60/40 w/w P(ε-CL/DL-LA) and TCP were examined in experimental animals. The follow-up times were from one week to 52 weeks. The bone samples were evaluated histologically and the soft tissue samples histologically, immunohistochemically and electronmicroscopically. The results showed that the resorption time of gamma sterilized POE 140 was eight weeks and ethylene oxide sterilized POE 140 13 weeks in bone. The resorption time of POE 46 was more than 24 weeks. The gamma sterilized rods started to erode from the surface faster than ethylene oxide sterilized rods for both POEs. Inflammation in bone was from slight to moderate with POE 140 and moderate with POE 46. No highly fluorescent layer of tenascin or fibronectin was found in the soft tissue. Bone healing at the sites of implantation was slower than at control sites with the copolymer in small bone defects. The resorption time for the copolymer was over one year. Inflammation in bone was mostly moderate. Bone healing at the sites of implantation was also slower than at the control sites with the composite in small and large mandibular bone defects. Bone formation had ceased at both sites by the end of follow-up in large mandibular bone defects. The ultrastructure of the connective tissue was normal during the period of observation. It can be concluded that the method of sterilization influenced the resorption time of both POEs. Gamma sterilized POE 140 could have been suitable material for filling small bone defects, whereas the degradation times of solid EO-sterilized POE 140 and POE 46 were too slow to be considered as bone filling material. Solid material is difficult to contour, which can be considered as a disadvantage. The composites were excellent to handle, but the degradation time of the polymer and the composites were too slow. Therefore, the copolymer and the composite can not be recommended as bone filling material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Spirometry is the most widely used lung function test in the world. It is fundamental in diagnostic and functional evaluation of various pulmonary diseases. In the studies described in this thesis, the spirometric assessment of reversibility of bronchial obstruction, its determinants, and variation features are described in a general population sample from Helsinki, Finland. This study is a part of the FinEsS study, which is a collaborative study of clinical epidemiology of respiratory health between Finland (Fin), Estonia (Es), and Sweden (S). Asthma and chronic obstructive pulmonary disease (COPD) constitute the two major obstructive airways diseases. The prevalence of asthma has increased, with around 6% of the population in Helsinki reporting physician-diagnosed asthma. The main cause of COPD is smoking with changes in smoking habits in the population affecting its prevalence with a delay. Whereas airway obstruction in asthma is by definition reversible, COPD is characterized by fixed obstruction. Cough and sputum production, the first symptoms of COPD, are often misinterpreted for smokers cough and not recognized as first signs of a chronic illness. Therefore COPD is widely underdiagnosed. More extensive use of spirometry in primary care is advocated to focus smoking cessation interventions on populations at risk. The use of forced expiratory volume in six seconds (FEV6) instead of forced vital capacity (FVC) has been suggested to enable office spirometry to be used in earlier detection of airflow limitation. Despite being a widely accepted standard method of assessment of lung function, the methodology and interpretation of spirometry are constantly developing. In 2005, the ATS/ERS Task Force issued a joint statement which endorsed the 12% and 200 ml thresholds for significant change in forced expiratory volume in one second (FEV1) or FVC during bronchodilation testing, but included the notion that in cases where only FVC improves it should be verified that this is not caused by a longer exhalation time in post-bronchodilator spirometry. This elicited new interest in the assessment of forced expiratory time (FET), a spirometric variable not usually reported or used in assessment. In this population sample, we examined FET and found it to be on average 10.7 (SD 4.3) s and to increase with ageing and airflow limitation in spirometry. The intrasession repeatability of FET was the poorest of the spirometric variables assessed. Based on the intrasession repeatability, a limit for significant change of 3 s was suggested for FET during bronchodilation testing. FEV6 was found to perform equally well as FVC in the population and in a subgroup of subjects with airways obstruction. In the bronchodilation test, decreases were frequently observed in FEV1 and particularly in FVC. The limit of significant increase based on the 95th percentile of the population sample was 9% for FEV1 and 6% for FEV6 and FVC; these are slightly lower than the current limits for single bronchodilation tests (ATS/ERS guidelines). FEV6 was proven as a valid alternative to FVC also in the bronchodilation test and would remove the need to control duration of exhalation during the spirometric bronchodilation test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Continuous epidural analgesia (CEA) and continuous spinal postoperative analgesia (CSPA) provided by a mixture of local anaesthetic and opioid are widely used for postoperative pain relief. E.g., with the introduction of so-called microcatheters, CSPA found its way particularly in orthopaedic surgery. These techniques, however, may be associated with dose-dependent side-effects as hypotension, weakness in the legs, and nausea and vomiting. At times, they may fail to offer sufficient analgesia, e.g., because of a misplaced catheter. The correct position of an epidural catheter might be confirmed by the supposedly easy and reliable epidural stimulation test (EST). The aims of this thesis were to determine a) whether the efficacy, tolerability, and reliability of CEA might be improved by adding the α2-adrenergic agonists adrenaline and clonidine to CEA, and by the repeated use of EST during CEA; and, b) the feasibility of CSPA given through a microcatheter after vascular surgery. Studies I IV were double-blinded, randomized, and controlled trials; Study V was of a diagnostic, prospective nature. Patients underwent arterial bypass surgery of the legs (I, n=50; IV, n=46), total knee arthroplasty (II, n=70; III, n=72), and abdominal surgery or thoracotomy (V, n=30). Postoperative lumbar CEA consisted of regular mixtures of ropivacaine and fentanyl either without or with adrenaline (2 µg/ml (I) and 4 µg/ml (II)) and clonidine (2 µg/ml (III)). CSPA (IV) was given through a microcatheter (28G) and contained either ropivacaine (max. 2 mg/h) or a mixture of ropivacaine (max. 1 mg/h) and morphine (max. 8 µg/h). Epidural catheter tip position (V) was evaluated both by EST at the moment of catheter placement and several times during CEA, and by epidurography as reference diagnostic test. CEA and CSPA were administered for 24 or 48 h. Study parameters included pain scores assessed with a visual analogue scale, requirements of rescue pain medication, vital signs, and side-effects. Adrenaline (I and II) had no beneficial influence as regards the efficacy or tolerability of CEA. The total amounts of epidurally-infused drugs were even increased in the adrenaline group in Study II (p=0.02, RM ANOVA). Clonidine (III) augmented pain relief with lowered amounts of epidurally infused drugs (p=0.01, RM ANOVA) and reduced need for rescue oxycodone given i.m. (p=0.027, MW-U; median difference 3 mg (95% CI 0 7 mg)). Clonidine did not contribute to sedation and its influence on haemodynamics was minimal. CSPA (IV) provided satisfactory pain relief with only limited blockade of the legs (no inter-group differences). EST (V) was often related to technical problems and difficulties of interpretation, e.g., it failed to identify the four patients whose catheters were outside the spinal canal already at the time of catheter placement. As adjuvants to lumbar CEA, clonidine only slightly improved pain relief, while adrenaline did not provide any benefit. The role of EST applied at the time of epidural catheter placement or repeatedly during CEA remains open. The microcatheter CSPA technique appeared effective and reliable, but needs to be compared to routine CEA after peripheral arterial bypass surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The outcome of the successfully resuscitated patient is mainly determined by the extent of hypoxic-ischemic cerebral injury, and hypothermia has multiple mechanisms of action in mitigating such injury. The present study was undertaken from 1997 to 2001 in Helsinki as a part of the European multicenter study Hypothermia after cardiac arrest (HACA) to test the neuroprotective effect of therapeutic hypothermia in patients resuscitated from out-of-hospital ventricular fibrillation (VF) cardiac arrest (CA). The aim of this substudy was to examine the neurological and cardiological outcome of these patients, and especially to study and develop methods for prediction of outcome in the hypothermia-treated patients. A total of 275 patients were randomized to the HACA trial in Europe. In Helsinki, 70 patients were enrolled in the study according to the inclusion criteria. Those randomized to hypothermia were actively cooled externally to a core temperature 33 ± 1ºC for 24 hours with a cooling device. Serum markers of ischemic neuronal injury, NSE and S-100B, were sampled at 24, 36, and 48 hours after CA. Somatosensory and brain stem auditory evoked potentials (SEPs and BAEPs) were recorded 24 to 28 hours after CA; 24-hour ambulatory electrocardiography recordings were performed three times during the first two weeks and arrhythmias and heart rate variability (HRV) were analyzed from the tapes. The clinical outcome was assessed 3 and 6 months after CA. Neuropsychological examinations were performed on the conscious survivors 3 months after the CA. Quantitative electroencephalography (Q-EEG) and auditory P300 event-related potentials were studied at the same time-point. Therapeutic hypothermia of 33ºC for 24 hours led to an increased chance of good neurological outcome and survival after out-of-hospital VF CA. In the HACA study, 55% of hypothermia-treated patients and 39% of normothermia-treated patients reached a good neurological outcome (p=0.009) at 6 months after CA. Use of therapeutic hypothermia was not associated with any increase in clinically significant arrhythmias. The levels of serum NSE, but not the levels of S-100B, were lower in hypothermia- than in normothermia-treated patients. A decrease in NSE values between 24 and 48 hours was associated with good outcome at 6 months after CA. Decreasing levels of serum NSE but not of S-100B over time may indicate selective attenuation of delayed neuronal death by therapeutic hypothermia, and the time-course of serum NSE between 24 and 48 hours after CA may help in clinical decision-making. In SEP recordings bilaterally absent N20 responses predicted permanent coma with a specificity of 100% in both treatment arms. Recording of BAEPs provided no additional benefit in outcome prediction. Preserved 24- to 48-hour HRV may be a predictor of favorable outcome in CA patients treated with hypothermia. At 3 months after CA, no differences appeared in any cognitive functions between the two groups: 67% of patients in the hypothermia and 44% patients in the normothermia group were cognitively intact or had only very mild impairment. No significant differences emerged in any of the Q-EEG parameters between the two groups. The amplitude of P300 potential was significantly higher in the hypothermia-treated group. These results give further support to the use of therapeutic hypothermia in patients with sudden out-of-hospital CA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A Pt-Au alloy catalyst of varying compositions is prepared by codeposition of Pt and Au nanoparticles onto a carbon support to evaluate its electrocatalytic activity toward an oxygen reduction reaction (ORR) with methanol tolerance in direct methanol fuel cells. The optimum atomic weight ratio of Pt to Au in the carbon-supported Pt-Au alloy (Pt-Au/C) as established by cell polarization, linear-sweep voltammetry (LSV), and cyclic voltammetry (CV) studies is determined to be 2:1. A direct methanol fuel cell (DMFC) comprising a carbon-supported Pt-Au (2:1) alloy as the cathode catalyst delivers a peak power density of 120 mW/cm2 at 70 °C in contrast to the peak power density value of 80 mW/cm2 delivered by the DMFC with carbon-supported Pt catalyst operating under identical conditions. Density functional theory (DFT) calculations on a small model cluster reflect electron transfer from Pt to Au within the alloy to be responsible for the synergistic promotion of the oxygen-reduction reaction on a Pt-Au electrode.