933 resultados para cannabinoid drugs
Resumo:
In the 1980s, government agencies sought to utilize research on drug use prevention to design media campaigns. Enlisting the assistance of the national media, several campaigns were designed and initiated to bring anti-drug use messages to adolescents in the form of public service advertising. This research explores the sources of information selected by adolescents in grades 7 through 12 and how the selection of media and other sources of information relate to drug use behavior and attitudes and perceptions related to risk/harm and disapproval of friends' drug-using activities.^ Data collected from 1989 to 1992 in the Miami Coalition School Survey provided a random selection of secondary school studies. The responses of these students were analyzed using multivariate statistical techniques.^ Although many of the students selected media as the source for most of their information on the effects of drugs on the people who use them, the selection of media was found to be positively related to alcohol use and negatively related to marijuana use. The selection of friends, brothers, or sisters was a statistically significant source for adolescents who smoke cigarettes, use alcohol or marijuana.^ The results indicate that the anti-drug use messages received by students may be canceled out by media messages perceived to advocate substance use and that a more persuasive source of information for adolescents may be friends and siblings. As federal reports suggest that the economic costs of drug abuse will reach an estimated $150 billion by 1997 if current trends continue, prevention policy that addresses the glamorization of substance use remains a national priority. Additionally, programs that advocate prevention within the peer cluster must be supported, as peers are an influential source for both inspiring and possibly preventing drug use behavior. ^
Resumo:
Background HIV infection and drugs of abuse such as methamphetamine (METH), cocaine, and alcohol use have been identified as risk factors for triggering inflammation. Acute phase proteins such as C-reactive protein (CRP) and serum amyloid A (SAA) are the biomarkers of inflammation. Hence, the interactive effect of drugs of abuse with acute phase proteins in HIV-positive subjects was investigated. Methods Plasma samples were utilized from 75 subjects with METH use, cocaine use, alcohol use, and HIV-positive alone and HIV-positive METH, cocaine, and alcohol users, and age-matched control subjects. The plasma CRP and SAA levels were measured by ELISA and western blot respectively and the CD4 counts were also measured. Results Observed results indicated that the CRP and SAA levels in HIV-positive subjects who are METH, cocaine and alcohol users were significantly higher when compared with either drugs of abuse or HIV-positive alone. The CD4 counts were also dramatically reduced in HIV-positive with drugs of abuse subjects compared with only HIV-positive subjects. Conclusions These results suggest that, in HIV-positive subjects, drugs of abuse increase the levels of CRP and SAA, which may impact on the HIV infection and disease progression.
Resumo:
New designer drugs are constantly emerging onto the illicit drug market and it is often difficult to validate and maintaincomprehensive analytical methods for accurate detection of these compounds. Generally, toxicology laboratories utilize a screening method, such as immunoassay, for the presumptive identification of drugs of abuse. When a positive result occurs, confirmatory methods, such as gas chromatography (GC) or liquid chromatography (LC) coupled with mass spectrometry (MS), are required for more sensitive and specific analyses. In recent years, the need to study the activities of these compounds in screening assays as well as to develop confirmatory techniques to detect them in biological specimens has been recognized. Severe intoxications and fatalities have been encountered with emerging designer drugs, presenting analytical challenges for detection and identification of such novel compounds. The first major task of this research was to evaluate the performance of commercially available immunoassays to determine if designer drugs were cross-reactive. The second major task was to develop and validate a confirmatory method, using LC-MS, to identify and quantify these designer drugs in biological specimens.^ Cross-reactivity towards the cathinone derivatives was found to be minimal. Several other phenethylamines demonstrated cross-reactivity at low concentrations, but results were consistent with those published by the assay manufacturer or as reported in the literature. Current immunoassay-based screening methods may not be ideal for presumptively identifying most designer drugs, including the "bath salts." For this reason, an LC-MS based confirmatory method was developed for 32 compounds, including eight cathinone derivatives, with limits of quantification in the range of 1-10 ng/mL. The method was fully validated for selectivity, matrix effects, stability, recovery, precision, and accuracy. In order to compare the screening and confirmatory techniques, several human specimens were analyzed to demonstrate the importance of using a specific analytical method, such as LC-MS, to detect designer drugs in serum as immunoassays lack cross-reactivity with the novel compounds. Overall, minimal cross-reactivity was observed, highlighting the conclusion that these presumptive screens cannot detect many of the designer drugs and that a confirmatory technique, such as the LC-MS, is required for the comprehensive forensic toxicological analysis of designer drugs.^
Resumo:
Despite the ongoing "war on drugs" the seizure rates for phenethylamines and their analogues have been steadily increasing over the years. The illicit manufacture of these compounds has become big business all over the world making it all the more attractive to the inexperienced "cook". However, as a result, the samples produced are more susceptible to contamination with reactionary byproducts and leftover reagents. These impurities are useful in the analysis of seized drugs as their identities can help to determine the synthetic pathway used to make these drugs and thus, the provenance of these analytes. In the present work two fluorescent dyes, 4-fluoro-7-nitrobenzofurazan and 5-(4,6-dichlorotriazinyl)aminofluorescein, were used to label several phenethylamine analogues for electrophoretic separation with laser-induced fluorescence detection. The large scale to which law enforcement is encountering these compounds has the potential to create a tremendous backlog. In order to combat this, a rapid, sensitive method capable of full automation is required. Through the utilization of the inline derivatization method developed whereby analytes are labeled within the capillary efficiently in a minimum span of time, this can be achieved. The derivatization and separation parameters were optimized on the basis of a variety of experimentally determined factors in order to give highly resolved peaks in the fluorescence spectrum with limits of detection in the low µg/mL range.
Resumo:
Using the securitization framework to highlight the arguments that facilitated the “War on Drugs”, this paper highlights a separate war against drug traffickers. Facilitated by ideology through the rhetoric promoted by the “War on Drugs,” the fear of communist expansion and democratic contraction, the “War on Drug Traffickers” was implemented, requiring its own strategy separate from the “War on Drugs.” This is an important distinction because the play on words changes the perception of the issue from one of drug addiction to one of weak institutions and insurgent/terrorist threat to those institutions. Furthermore, one cannot propose strategy to win, lose, or retreat in a war that one has been unable to identify properly. And while the all-encompassing “War on Drugs” has motivated tremendous discourse on its failure and possible solutions to remedy its failure, the generalizations made as a result of the inability to distinguish between the policies behind drug addiction and the militarized policies behind drug trafficking have discounted the effect of violence perpetrated by the state, the rationale for the state perpetrating that violence, and the dependence that the state has on foreign actors to perpetrate such violence. This makes it impossible to not only propose effective strategy but also to persuade states that participate in the “War on Drug Traffickers” to adopt the proposed strategy.
Resumo:
TBA
Resumo:
Today, over 15,000 Ion Mobility Spectrometry (IMS) analyzers are employed at worldwide security checkpoints to detect explosives and illicit drugs. Current portal IMS instruments and other electronic nose technologies detect explosives and drugs by analyzing samples containing the headspace air and loose particles residing on a surface. Canines can outperform these systems at sampling and detecting the low vapor pressure explosives and drugs, such as RDX, PETN, cocaine, and MDMA, because these biological detectors target the volatile signature compounds available in the headspace rather than the non-volatile parent compounds of explosives and drugs. In this dissertation research volatile signature compounds available in the headspace over explosive and drug samples were detected using SPME as a headspace sampling tool coupled to an IMS analyzer. A Genetic Algorithm (GA) technique was developed to optimize the operating conditions of a commercial IMS (GE Itemizer 2), leading to the successful detection of plastic explosives (Detasheet, Semtex H, and C-4) and illicit drugs (cocaine, MDMA, and marijuana). Short sampling times (between 10 sec to 5 min) were adequate to extract and preconcentrate sufficient analytes (> 20 ng) representing the volatile signatures in the headspace of a 15 mL glass vial or a quart-sized can containing ≤ 1 g of the bulk explosive or drug. Furthermore, a research grade IMS with flexibility for changing operating conditions and physical configurations was designed and fabricated to accommodate future research into different analytes or physical configurations. The design and construction of the FIU-IMS were facilitated by computer modeling and simulation of ion’s behavior within an IMS. The simulation method developed uses SIMION/SDS and was evaluated with experimental data collected using a commercial IMS (PCP Phemto Chem 110). The FIU-IMS instrument has comparable performance to the GE Itemizer 2 (average resolving power of 14, resolution of 3 between two drugs and two explosives, and LODs range from 0.7 to 9 ng). The results from this dissertation further advance the concept of targeting volatile components to presumptively detect the presence of concealed bulk explosives and drugs by SPME-IMS, and the new FIU-IMS provides a flexible platform for future IMS research projects.
Resumo:
This study was supported by a Wellcome Trust-NIH PhD Studentship to SB, WDF and NV. Grant number 098252/Z/12/Z. SB, CHC and WDF are supported by the Intramural Research Program, NCI, NIH. NHG and WL are supported by the Intramural Research Program, NIA, NIH.
Resumo:
Funding ABK was funded by a studentship from the University of Aberdeen, Institute of Medical Sciences, and the Overseas Research Students Awards Scheme Acknowledgments We are grateful to Dr J.S. Gregory for assistance with Image J and Mr K. Mackenzie for assistance with Micro-CT analysis.
Resumo:
This work was supported by the European Union's Seventh Framework Programme for research, technological development and demonstration under grant agreement No 305316 as part of the MOTIF (Microbicides Optimisation Through Innovative Formulation for Vaginal and Rectal Delivery) project. We would like to extend our thanks to all the study participants for their invaluable contribution and to Grampian Biorepository staff for help with collection of fresh colorectal resection tissue.
Resumo:
General note: Title and date provided by Bettye Lane.
Resumo:
Thèse numérisée par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
Objective: To assess the effects of selective cyclo-oxygenase-2 (COX 2) inhibitors and traditional non-steroidal anti-inflammatory drugs (NSAIDs) on the risk of vascular events. Design: Meta-analysis of published and unpublished tabular data from randomised trials, with indirect estimation of the effects of traditional NSAIDs. Data sources: Medline and Embase (January 1966 to April 2005); Food and Drug Administration records; and data on file from Novartis, Pfizer, and Merck. Review methods: Eligible studies were randomised trials that included a comparison of a selective COX 2 inhibitor versus placebo or a selective COX 2 inhibitor versus a traditional NSAID, of at least four weeks' duration, with information on serious vascular events (defined as myocardial infarction, stroke, or vascular death). Individual investigators and manufacturers provided information on the number of patients randomised, numbers of vascular events, and the person time of follow-up for each randomised group. Results: In placebo comparisons, allocation to a selective COX 2 inhibitor was associated with a 42% relative increase in the incidence of serious vascular events (1.2%/year v 0.9%/year; rate ratio 1.42, 95% confidence interval 1.13 to 1.78; P = 0.003), with no significant heterogeneity among the different selective COX 2 inhibitors. This was chiefly attributable to an increased risk of myocardial infarction (0.6%/year v 0.3%/year; 1.86, 1.33 to 2.59; P = 0.0003), with little apparent difference in other vascular outcomes. Among trials of at least one year's duration (mean 2.7 years), the rate ratio for vascular events was 1.45 (1.12 to 1.89; P = 0.005). Overall, the incidence of serious vascular events was similar between a selective COX 2 inhibitor and any traditional NSAID (1.0%/year v 0.9/%year; 1.16, 0.97 to 1.38; P = 0.1). However, statistical heterogeneity (P = 0.001) was found between trials of a selective COX 2 inhibitor versus naproxen (1.57, 1.21 to 2.03) and of a selective COX 2 inhibitor versus non-naproxen NSAIDs (0.88, 0.69 to 1.12). The summary rate ratio for vascular events, compared with placebo, was 0.92 (0.67 to 1.26) for naproxen, 1.51 (0.96 to 2.37) for ibuprofen, and 1.63 (1.12 to 2.37) for diclofenac. Conclusions: Selective COX 2 inhibitors are associated with a moderate increase in the risk of vascular events, as are high dose regimens of ibuprofen and diclofenac, but high dose naproxen is not associated with such an excess.
Resumo:
While using the brand names seems like a trivial issue at the outset, using these names is inherently problematic. Cardiovascular drugs remain the most commonly prescribed drugs by the physicians. The junior doctors are likely to introject practices of their seniors and consequently to reciprocate from the experiences learnt from their preceptors. Using the generic names may be one way to facilitate prescription of the generic drugs who have a better cost profile and similar efficacy than the more expensive branded drugs. In this editorial, we have outlined several arguments to suggest the importance of using the generic names in academic discussions and clinical documentation.