975 resultados para Unmanned air vehicle
Resumo:
An examination of the impact in the US and EU markets of two major innovations in the provision of air services on thin routes - regional jet technology and the low-cost business model - reveals significant differences. In the US, regional airlines monopolize a high proportion of thin routes, whereas low-cost carriers are dominant on these routes in Europe. Our results have different implications for business and leisure travelers, given that regional services provide a higher frequency of flights (at the expense of higher fares), while low-cost services offer lower fares (at the expense of lower flight frequencies).
Resumo:
A photonic system has been developed that enables sensitive quantitative determination of reactive oxygen species (ROS) - mainly hydrogen peroxide (H2O2) - in aerosol samples such as airborne nanoparticles and exhaled air from patients. The detection principle relies on the amplification of the absorbance under multiple scattering conditions due to optical path lengthening [1] and [2]. In this study, the presence of cellulose membrane that acts as random medium into the glass optical cell considerably improved the sensitivity of the detection based on colorimetric FOX assay (FeII/orange xylenol). Despite the loss of assay volume (cellulose occupies 75% of cell volume) the limit of detection is enhanced by one order of magnitude reaching the value of 9 nM (H2O2 equivalents). Spectral analysis is performed automatically with a periodicity of 5 to 15 s, giving rise to real-time ROS measurements. Moreover, the elution of air sample into the collection chamber via a micro-diffuser (impinger) enables quantitative determination of ROS contained in or generated from airborne samples. As proof-of-concept the photonic ROS detection system was used in the determination of both ROS generated from traffic pollution and ROS contained in the exhaled breath as lung inflammation biomarkers.
Resumo:
L'exposition professionnelle aux nanomatériaux manufacturés dans l'air présente des risques potentiels pour la santé des travailleurs dans les secteurs de la nanotechnologie. Il est important de comprendre les scénarios de libération des aérosols de nanoparticules dans les processus et les activités associées à l'exposition humaine. Les mécanismes de libération, y compris les taux de libération et les propriétés physico-chimiques des nanoparticules, déterminent leurs comportements de transport ainsi que les effets biologiques néfastes. La distribution de taille des particules d'aérosols est l'un des paramètres les plus importants dans ces processus. La stabilité mécanique d'agglomérats de nanoparticules affecte leurs distributions de tailles. Les potentiels de désagglomération de ces agglomérats déterminent les possibilités de leur déformation sous énergies externes. Cela rend les changements possibles dans leur distribution de taille et de la concentration en nombre qui vont finalement modifier leurs risques d'exposition. Les conditions environnementales, telles que l'humidité relative, peuvent influencer les processus de désagglomération par l'adhérence de condensation capillaire de l'humidité. L'objectif général de cette thèse était d'évaluer les scénarios de libération des nanomatériaux manufacturés des processus et activités sur le lieu de travail. Les sous-objectifs étaient les suivants: 1. Etudier les potentiels de désagglomération des nanoparticules dans des conditions environnementales variées. 2. Etudier la libération des nano-objets à partir de nanocomposites polymères; 3. Evaluer la libération de nanoparticules sur le lieu de travail dans des situations concrètes. Nous avons comparé différents systèmes de laboratoire qui présentaient différents niveau d'énergie dans l'aérosolisation des poudres. Des nanopoudres de TiO2 avec des hydrophilicités de surface distinctes ont été testées. Un spectromètre à mobilité électrique (SMPS), un spectromètre à mobilité aérodynamique (APS) et un spectromètre optique (OPC) ont été utilisés pour mesurer la concentration de particules et la distribution de taille des particules. La microscopie électronique à transmission (TEM) a été utilisée pour l'analyse morphologique d'échantillons de particules dans l'air. Les propriétés des aérosols (distribution de taille et concentration en nombre) étaient différentes suivant la méthode employée. Les vitesses des flux d'air d'aérosolisation ont été utilisées pour estimer le niveau d'énergie dans ces systèmes, et il a été montré que les tailles modales des particules étaient inversement proportionnelles à la vitesse appliquée. En général, les particules hydrophiles ont des diamètres plus grands et des nombres inférieurs à ceux des particules hydrophobes. Toutefois, cela dépend aussi des méthodes utilisées. La vitesse de l'air peut donc être un paramètre efficace pour le classement de l'énergie des procédés pour des systèmes d'aérosolisation similaires. Nous avons développé un système laboratoire pour tester les potentiels de désagglomération des nanoparticules dans l'air en utilisant des orifices critiques et un humidificateur. Sa performance a été comparée à un système similaire dans un institut partenaire. Une variété de nanopoudres différentes a été testée. Le niveau d'énergie appliquée et l'humidité ont été modifiés. Le SMPS et l'OPC ont été utilisés pour mesurer la concentration de particules et la distribution de la taille. Un TEM a été utilisé pour l'analyse morphologique d'échantillons de particules dans l'air. Le diamètre moyen des particules a diminué et la concentration en nombre s'est accrue lorsque des énergies externes ont été appliquées. Le nombre de particules inférieures à 100 nm a été augmenté, et celui au-dessus de 350 nm réduits. Les conditions humides ont faits exactement le contraire, en particulier pour les petites particules. En outre, ils ont réduits les effets de la différence de pression due à l'orifice. Les résultats suggèrent que la désagglomération d'agglomérats de nanoparticules dans l'air est possible dans la gamme d'énergie appliquée. Cependant, l'atmosphère humide peut favoriser leur agglomération et améliorer leurs stabilités en réduisant la libération de nanoparticules dans l'environnement. Nous proposons d'utiliser notre système pour le test de routine des potentiels de désagglomération des nanomatériaux manufacturés et de les classer. Un tel classement faciliterait la priorisation de l'exposition et du risque encouru en fonction du niveau d'ENM. Un système de perçage automatique et un système de sciage manuel ont été développés pour étudier la libération de nanoparticules à partir de différents types de nanocomposites. La vitesse de perçage et taille de la mèche ont été modifiées dans les expériences. La distribution de taille des particules et leur concentration en nombre ont été mesurées par un SMPS et un miniature diffusion size classifier (DISCmini). Les distributions de nanoparticules dans les composites et les particules libérées ont été analysés par un TEM et un microscope électronique à balayage (SEM). Les tests de perçage ont libérés un plus grand nombre de particules que le sciage. Des vitesses de perçage plus rapide et les mèches plus grandes ont augmentés la génération de particules. Les charges de nanoparticules manufacturées dans les composites ne modifient pas leurs comportements de libération dans les expériences de perçage. Toutefois, le sciage différencie les niveaux de libération entre les composites et les échantillons blancs. De plus, les vapeurs de polymères ont été générées par la chaleur de sciage. La plupart des particules libérées sont des polymères contenant des nanoparticules ou sur leurs surface. Les résultats ont souligné l'importance du type de processus et paramètres pour déterminer la libération de nanoparticules de composites. Les émissions secondaires telles que les fumées polymères appellent à la nécessité d'évaluations de l'exposition et de risque pour de tels scénarios. Une revue systématique de la littérature sur le sujet de libérations de nanoparticules dans l'air dans les secteurs industriels et laboratoires de recherche a été effectuée. Des stratégies de recherche des informations pertinentes et de stockage ont été développées. Les mécanismes de libération, tels que la taille de particules d'aérosol et de leur concentration en nombre, ont été comparés pour différentes activités. La disponibilité de l'information contextuelle qui est pertinente pour l'estimation de l'exposition humaine a été évaluée. Il a été constaté que les données relatives à l'exposition ne sont pas toujours disponibles dans la littérature actuelle. Les propriétés des aérosols libérés semblent dépendre de la nature des activités. Des procédés à haute énergie ont tendance à générer des plus hauts niveaux de concentrations de particules dans les gammes de plus petite taille. Les résultats peuvent être utiles pour déterminer la priorité des procédés industriels pour l'évaluation les risques associés dans une approche à plusieurs niveaux. Pour l'évaluation de l'exposition, la disponibilité de l'information peut être améliorée par le développement d'une meilleure méthode de communication des données.
Resumo:
Objective The authors have sought to study the calibration of a clinical PKA meter (Diamentor E2) and a calibrator for clinical meters (PDC) in the Laboratory of Ionizing Radiation Metrology at Instituto de Energia e Ambiente - Universidade de São Paulo. Materials and Methods Different qualities of both incident and transmitted beams were utilized in conditions similar to a clinical setting, analyzing the influence from the reference dosimeter, from the distance between meters, from the filtration and from the average beam energy. Calibrations were performed directly against a standard 30 cm3 cylindrical chamber or a parallel-plate monitor chamber, and indirectly against the PDC meter. Results The lowest energy dependence was observed for transmitted beams. The cross calibration between the Diamentor E2 and the PDC meters, and the PDC presented the greatest propagation of uncertainties. Conclusion The calibration coefficient of the PDC meter showed to be more stable with voltage, while the Diamentor E2 calibration coefficient was more variable. On the other hand, the PDC meter presented greater uncertainty in readings (5.0%) than with the use of the monitor chamber (3.5%) as a reference.
Resumo:
The authors report a case of umbilical venous catheter malposition with air in the portal venous system in a preterm neonate. Initially, the hypothesis of necrotizing enterocolitis was considered, but the newborn progressed with no finding of disease and the air disappeared at follow-up radiography. The differential diagnosis of such a finding can avoid unnecessary clinical treatments.
Resumo:
A capillary microtrap thermal desorption module is developed for near real-time analysis of volatile organic compounds (VOCs) at sub-ppbv levels in air samples. The device allows the direct injection of the thermally desorbed VOCs into a chromatographic column. It does not use a second cryotrap to focalize the adsorbed compounds before entering the separation column so reducing the formation of artifacts. The connection of the microtrap to a GC–MS allows the quantitative determination of VOCs in less than 40 min with detection limits of between 5 and 10 pptv (25 °C and 760 mmHg), which correspond to 19–43 ng m−3, using sampling volumes of 775 cm3. The microtrap is applied to the analysis of environmental air contamination in different laboratories of our faculty. The results obtained indicate that most volatile compounds are easily diffused through the air and that they also may contaminate the surrounding areas when the habitual safety precautions (e.g., working under fume hoods) are used during the manipulation of solvents. The application of the microtrap to the analysis of VOCs in breath samples suggest that 2,5-dimethylfuran may be a strong indicator of a person's smoking status
Resumo:
Aquest projecte té com a objectiu la simulació numérica de la carrosseria d’ un vehicle de curses de muntanya de categoria CM
Resumo:
Hybrid electric vehicles (HEV) have attracted very much attention during the latest years. Increasing environmental concern and an increase in fuel prices are key factors for the growing interest towards the HEV. In a hybrid electric vehicle the power train consists of both a mechanical power system and an electric power transmission system. The major subsystems in the mechanical power system are the internal combustion engine which powers the vehicle; electric power transmission including an energy storage, power electronic inverter, hybrid control system; the electric motor drive that runs either in the generating mode or in the motoring mode to process the power flow between the energy storage and the electrical machine. This research includes two advanced electric motors for a parallel hybrid: induction machine and permanent magnets synchronous machine. In the thesis an induction motor and a permanent magnet motor are compared as propulsion motors. Electric energy storages are also studied.
Resumo:
Case-crossover is one of the most used designs for analyzing the health-related effects of air pollution. Nevertheless, no one has reviewed its application and methodology in this context. Objective: We conducted a systematic review of case-crossover (CCO) designs used to study the relationship between air pollution and morbidity and mortality, from the standpoint of methodology and application.Data sources and extraction: A search was made of the MEDLINE and EMBASE databases.Reports were classified as methodologic or applied. From the latter, the following information was extracted: author, study location, year, type of population (general or patients), dependent variable(s), independent variable(s), type of CCO design, and whether effect modification was analyzed for variables at the individual level. Data synthesis: The review covered 105 reports that fulfilled the inclusion criteria. Of these, 24 addressed methodological aspects, and the remainder involved the design’s application. In the methodological reports, the designs that yielded the best results in simulation were symmetric bidirectional CCO and time-stratified CCO. Furthermore, we observed an increase across time in the use of certain CCO designs, mainly symmetric bidirectional and time-stratified CCO. The dependent variables most frequently analyzed were those relating to hospital morbidity; the pollutants most often studied were those linked to particulate matter. Among the CCO-application reports, 13.6% studied effect modification for variables at the individual level.Conclusions: The use of CCO designs has undergone considerable growth; the most widely used designs were those that yielded better results in simulation studies: symmetric bidirectional and time-stratified CCO. However, the advantages of CCO as a method of analysis of variables at the individual level are put to little use
Resumo:
Most modern passenger aeroplanes use air cycle cooling. A high-speed air cycle is a reliable and light option, but not very efficient. This thesis presents research work done to design a novel vapour cooling cycle for aeroplanes. Due to advancements in high-speed permanent magnet motors, the vapour cycle is seen as a competitive option for the air cycle in aeroplanes. The aerospace industry places tighter demands on the weight, reliability and environmental effects of the machinery than those met by conventional chillers, and thus modifications to conventional design are needed. The thesis is divided into four parts: the initial screening of the working fluid, 1-D design and performance values of the compressor, 1-D off-design value predictions of the compressor and the 3-D design of the compressor. The R245fa was selected as the working fluid based the study. The off-design range of the compressor was predicted to be wide and suitable for the application. The air-conditioning system developed is considerably smaller than previous designs using centrifugal compressors.
Resumo:
The promotion of energy-efficient appliances is necessary to reduce the energetic and environmental burden of the household sector. However, many studies have reported that a typical consumer underestimates the benefits of energy-saving investment on the purchase of household electric appliances. To analyze this energy-efficiency gap problem, many scholars have estimated implicit discount rates that consumers use for energy-consuming durables. Although both hedonic and choice models have been used in previous studies, a comparison between two models has not yet been done. This study uses point of sale data about Japanese residential air conditioners and estimates implicit discounts rates with both hedonic and choice models. Both models demonstrate that a typical consumer underinvests in energy efficiency. Although choice models estimate a lower implicit discount rate than hedonic models, the latter models estimate the values of other product characteristics more consistently than choice models.
Resumo:
The present paper constitutes a synthesis of the results gotten during the five campaigns of air quality measurement in the years of 2003 and 2004 carried out in the Portuguese city of Viana do Castelo to characterise the reference situation and to accompany the Polis Programme, an urban re-qualification and environmental valorisation plan. The main objective of the monitoring programme consisted of the evaluation of atmospheric pollutants whose levels were susceptible of enhancement in the course of the urbanistic public works. The presented results refer to measurements performed in two distinct places of this city, comprising various consecutive days of acquisition that include, at least, one day of weekend.
Resumo:
Something on the level of pure electric vehicle communication is failing. If the benefits are so obvious: reducing emissions, existing technology, etc., why not EV, start to lead the global sales? Whose interests may be behind it?
Resumo:
Daily records of hospital admissions due to cardiorespiratory diseases and levels of PM10, SO2, CO, NO, NO2, and O3 were collected from 1999-2004 to evaluate the relationship between air pollution and morbidity in Lisbon. Generalised additive Poisson regression models were adopted, controlling for temperature, humidity, and both short and long-term seasonality. Significant positive associations, lagged by 1 or 2 days, were found between markers of traffic-related pollution (CO and NO2) and cardiocirculatory diseases in all age groups. Increased childhood emergency admissions for respiratory illness were significantly correlated with the 1-day lagged SO2 levels coming from industrial activities.