977 resultados para TOTAL ARTIFICIAL-HEART


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia e Gestão Industrial

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 868 (84.89%) patients diagnosed with tetanus were studied, out of the 1,024 tetanus patients hospitalized at Couto Maia Hospital (Salvador, Bahia, Brazil), during the period between 1986 and 1997. Of this group (n = 868), 63.5% (n = 551) were discharged, 35.4% (n = 307) died, and 1.1% (n = 10) were transferred. The average age of the deceased patients (38.73 ± 23.31 years) was significantly greater (p < 0.0001) than the age of those who survived (29.21 ± 20.05 years). Analyzing the variables of the logistic regression model with statistic significance (p £ 0.25) for univariate analysis, we observed a greater association of risk for worst prognosis (death) in patients aged ³ 51 years; time of illness < 48 hours; time of incubation < 168 hours; neck rigidity; spasms; opisthotonos; body temperature ³ 37.7 ºC; heart beat ³ 111 beats/minute; sympathetic hyperactivity and association with pneumonia. Among the group of those who survived, patients with 1 to 5 of those variables (n = 398; 76.8%) were more frequent, while among patients of the group of the deceased, 70.3% (n = 206) presented 6 to 10 of those variables, with a highly significant difference (p < 10-8). In conclusion, the indicators described provide early information that may guide the prognosis and medical and nurse care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work measures and tries to compare the Antioxidant Capacity (AC) of 50 commercial beverages of different kinds: 6 wines, 12 beers, 18 soft drinks and 14 flavoured waters. Because there is no reference procedure established for this purpose, three different optical methods were used to analyse these samples: Total Radical trapping Antioxidant Parameter (TRAP), Trolox Equivalent Antioxidant Capacity (TEAC) and Ferric ion Reducing Antioxidant Parameter (FRAP). These methods differ on the chemical background and nature of redox system. The TRAP method involves the transfer of hydrogen atoms while TEAC and FRAP involves electron transfer reactions. The AC was also assessed against three antioxidants of reference, Ascorbic acid (AA), Gallic acid (GA) and 6-hydroxy-2,5,7,8-tetramethyl- 2-carboxylic acid (Trolox). The results obtained were analyzed statistically. Anova one-way tests were applied to all results and suggested that methods and standards exhibited significant statistical differences. The possible effect of sample features in the AC, such as gas, flavours, food colouring, sweeteners, acidity regulators, preservatives, stabilizers, vitamins, juice percentage, alcohol percentage, antioxidants and the colour was also investigated. The AC levels seemed to change with brand, kind of antioxidants added, and kind of flavour, depending on the sample. In general, higher ACs were obtained for FRAP as method, and beer for kind of sample, and the standard expressing the smaller AC values was GA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel artificial antibody for troponin T (TnT) was synthesized by molecular imprint (MI) on the surface of multiwalled carbon nanotubes (MWCNT). This was done by attaching TnT to the MWCNT surface, and filling the vacant spaces by polymerizing under mild conditions acrylamide (monomer) in N,N′-methylenebisacrylamide (cross-linker) and ammonium persulphate (initiator). After removing the template, the obtained biomaterial was able to rebind TnT and discriminate it among other interfering species. Stereochemical recognition of TnT was confirmed by the non-rebinding ability displayed by non-imprinted (NI) materials, obtained by imprinting without a template. SEM and FTIR analysis confirmed the surface modification of the MWCNT. The ability of this biomaterial to rebind TnT was confirmed by including it as electroactive compound in a PVC/plasticizer mixture coating a wire of silver, gold or titanium. Anionic slopes of 50 mV decade−1 were obtained for the gold wire coated with MI-based membranes dipped in HEPES buffer of pH 7. The limit of detection was 0.16 μg mL−1. Neither the NI-MWCNT nor the MWCNT showed the ability to recognize the template. Good selectivity was observed against creatinine, sucrose, fructose, myoglobin, sodium glutamate, thiamine and urea. The sensor was tested successfully on serum samples. It is expected that this work opens new horizons on the design of new artificial antibodies for complex protein structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular imprinting is a useful technique for the preparation of functional materials with molecular recognition properties. A Biomimetic Sensor Potentiometric System was developed for assessment of doxycycline (DOX) antibiotic. The molecularly imprinted polymer (MIP) was synthesized by using doxycycline as a template molecule, methacrylic acid (MAA) and/or acrylamide (AA) as a functional monomer and ethylene glycol dimethacrylat (EGDMA) as a cross-linking agent. The sensing elements were fabricated by the inclusion of DOX imprinted polymers in polyvinyl chloride (PVC) matrix. The sensors showed a high selectivity and a sensitive response to the template in aqueous system. Electrochemical evaluation of these sensors under static (batch) mode of operation reveals near-Nernstian response. MIP/MAA membrane sensor was incorporated in flow-through cells and used as detectors for flow injection analysis (FIA) of DOX. The method has the requisite accuracy, sensitivity and precision to assay DOX in tablets and biological fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary sarcoma of the heart is a rare disease that has an ominous prognosis with either medical or surgical therapy. We report a case of a 25-year-old woman with sarcoma of the heart who received a transplant and is clinically well after 7 years. We believe that transplantation must be considered in this kind of pathology for selected cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

4º Festival Nacional de Robótica - Actas do Encontro Científico - Proceedings of the Scientific Meeting, Biblioteca Almeida Garrett, Palácio de Cristal – Porto, 23-24 Abril 2004

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Surgery for congenital heart disease (CHD) has changed considerably during the last three decades. The results of primary repair have steadily improved, to allow treating almost all patients within the pediatric age; nonetheless an increasing population of adult patients requires surgical treatment. The objective of this study is to present the early surgical results of patients who require surgery for CHD in the adult population within a multicentered European study population. METHODS: Data relative to the hospital course of 2,012 adult patients (age > or = 18 years) who required surgical treatment for CHD from January 1, 1997 through December 31, 2004 were reviewed. Nineteen cardiothoracic centers from 13 European countries contributed to the data collection. RESULTS: Mean age at surgery was 34.4 +/- 14.53 years. Most of the operations were corrective procedures (1,509 patients, 75%), followed by reoperations (464 patients, 23.1%) and palliative procedures (39 patients, 1.9%). Six hundred forty-nine patients (32.2%) required surgical closure of an isolated ostium secundum atrial septal defect. Overall hospital mortality was 2%. Preoperative cyanosis, arrhythmias, and NYHA class III-IV, proved significant risk factors for hospital mortality. Follow-up data were available in 1,342 of 1,972 patients (68%) who were discharged home. Late deaths occurred in 6 patients (0.5%). Overall survival probability was 97% at 60 months, which is higher for corrective procedures (98.2%) if compared with reoperations (94.1%) and palliations (86.1%). CONCLUSIONS: Surgical treatment of CHD in adult patients, in specialized cardiac units, proved quite safe, beneficial, and low-risk.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the late 1960s, Melanoides tuberculatus snails were introduced in Brazil from North/East Africa and Southeast Asia. The first records of specimens infected with cercariae were registered in Rio de Janeiro State in 2001. The present study reports the occurrence of M. tuberculatus infected with larval trematodes in Rio de Janeiro City. Bottom sediment was collected with dip nets and sieved through 0.25 inch-mesh screening. Snails were transported to the laboratory in vials with stream water, then measured and individually isolated in glass vials with distilled water. They were exposed to artificial light and temperature to induce cercarial emergence. The most actively emerging cercariae were processed by differential staining and silver nitrate impregnation methods. Negative snails were subsequently dissected. Approximately 700 snails were collected. Snail total lengths ranged from 1.2 to 3.3 cm. The prevalence rate was 15.76% although 53.76% of the snails were found infected in one of the sites. Infected snails were infected with rediae and pleurolophocercous cercariae. Cercarial morphology and chaetotaxy were consistent with those of the family Heterophyidae mostly due to the presence of median dorsal and ventral fins on the tail and the absence of CI dorsal sensory receptors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Obesity is an important risk factor for the development of diabetes, hypertension, coronary disease, left ventricular dysfunction, stroke and cardiac arrhythmias. Paradoxically, previous studies in patients undergoing elective coronary angioplasty showed a reduction in hospital and long-term mortality in obese patients. The relation with body mass index (BMI) has been less studied in the context of primary angioplasty. OBJECTIVES: To evaluate the impact of obesity on the results of ST-segment elevation acute myocardial infarction treated by primary angioplasty. METHODS: This was a study of 464 consecutive patients with ST-segment elevation acute myocardial infarction undergoing primary angioplasty, 78% male, mean age 61 +/- 13 years. We assessed in-hospital, 30-day and one-year mortality according to BMI. Patients were divided into three groups according to BMI: normal--18-24.9 kg/m2 (n = 171); overweight--25-29.9 kg/m2 (n = 204); and obese-- > 30 kg/m2 (n = 89). RESULTS: Obese patients were younger (ANOVA, p < 0.001) and more frequently male (p = 0.014), with more hypertension (p = 0.001) and dyslipidemia (p = 0.006). There were no differences in the prevalence of diabetes, previous cardiac history, heart failure on admission, anterior location, multivessel disease, peak total CK or medication prescribed, except that obese patients received more beta-blockers (p = 0.049). In-hospital mortality was 9.9% for patients with normal BMI, 3.4% for overweight patients and 6.7% for obese patients (p = 0.038). Mortality at 30 days was 11 4.4% and 7.8% (p = 0.032) and at one year 12.9%, 4.9% and 9% (p = 0.023), respectively. On univariate analysis, overweight was the only BMI category with a protective effect; however, after multivariate logistic regression analysis, adjusted for confounding variables, none of the BMI categories could independently predict outcome. CONCLUSIONS: Overweight patients had a better prognosis after primary angioplasty for ST-segment elevation acute myocardial infarction compared with other BMI categories, but this was dependent on other potentially confounding variables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Adults with repaired tetralogy of Fallot (TOF) may be at risk for progressive right ventricular (RV) dilatation and dysfunction, which is commonly associated with arrhythmic events. In frequently volume-overloaded patients with congenital heart disease, tissue Doppler imaging (TDI) is particularly useful for assessing RV function. However, it is not known whether RV TDI can predict outcome in this population. OBJECTIVE: To evaluate whether RV TDI parameters are associated with supraventricular arrhythmic events in adults with repaired TOF. METHODS: We studied 40 consecutive patients with repaired TOF (mean age 35 +/- 11 years, 62% male) referred for routine echocardiographic exam between 2007 and 2008. The following echocardiographic measurements were obtained: left ventricular (LV) ejection fraction, LV end-systolic volume, LV end-diastolic volume, RV fractional area change, RV end-systolic area, RV end-diastolic area, left and right atrial volumes, mitral E and A velocities, RV myocardial performance index (Tei index), tricuspid annular plane systolic excursion (TAPSE), myocardial isovolumic acceleration (IVA), pulmonary regurgitation color flow area, TDI basal lateral, septal and RV lateral peak diastolic and systolic annular velocities (E' 1, A' 1, S' 1, E' s, A' s, S' s, E' rv, A' rv, S' rv), strain, strain rate and tissue tracking of the same segments. QRS duration on resting ECG, total duration of Bruce treadmill exercise stress test and presence of exercise-induced arrhythmias were also analyzed. The patients were subsequently divided into two groups: Group 1--12 patients with previous documented supraventricular arrhythmias (atrial tachycardia, fibrillation or flutter) and Group 2 (control group)--28 patients with no previous arrhythmic events. Univariate and multivariate analysis was used to assess the statistical association between the studied parameters and arrhythmic events. RESULTS: Patients with previous events were older (41 +/- 14 vs. 31 +/- 6 years, p = 0.005), had wider QRS (173 +/- 20 vs. 140 +/- 32 ms, p = 0.01) and lower maximum heart rate on treadmill stress testing (69 +/- 35 vs. 92 +/- 9%, p = 0.03). All patients were in NYHA class I or II. Clinical characteristics including age at corrective surgery, previous palliative surgery and residual defects did not differ significantly between the two groups. Left and right cardiac chamber dimensions and ventricular and valvular function as evaluated by conventional Doppler parameters were also not significantly different. Right ventricular strain and strain rate were similar between the groups. However, right ventricular myocardial TDI systolic (Sa: 5.4+2 vs. 8.5 +/- 3, p = 0.004) and diastolic indices and velocities (Ea, Aa, septal E/Ea, and RV free wall tissue tracking) were significantly reduced in patients with arrhythmias compared to the control group. Multivariate linear regression analysis identified RV early diastolic velocity as the sole variable independently associated with arrhythmic history (RV Ea: 4.5 +/- 1 vs. 6.7 +/- 2 cm/s, p = 0.01). A cut-off for RV Ea of < 6.1 cm/s identified patients in the arrhythmic group with 86% sensitivity and 59% specificity (AUC = 0.8). CONCLUSIONS: Our results suggest that TDI may detect RV dysfunction in patients with apparently normal function as assessed by conventional echocardiographic parameters. Reduction in RV early diastolic velocity appears to be an early abnormality and is associated with occurrence of arrhythmic events. TDI may be useful in risk stratification of patients with repaired tetralogy of Fallot.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies periodic gaits of multi-legged locomotion systems based on dynamic models. The purpose is to determine the system performance during walking and the best set of locomotion variables. For that objective the prescribed motion of the robot is completely characterized in terms of several locomotion variables such as gait, duty factor, body height, step length, stroke pitch, foot clearance, legs link lengths, foot-hip offset, body and legs mass and cycle time. In this perspective, we formulate three performance measures of the walking robot namely, the mean absolute energy, the mean power dispersion and the mean power lost in the joint actuators per walking distance. A set of model-based experiments reveals the influence of the locomotion variables in the proposed indices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cavopulmonary connections have been extensively used in the palliation of complex forms of congenital heart disease requiring some form of right heart bypass. We examine the mid term outcomes of pulmonary ventricle bypass operations in a single institution and performed by the same surgical team. POPULATION: Between March 1999 and April 2006, 62 patients underwent pulmonary ventricle bypass operations: bidirectional cavopulmonary anastomosis (Glenn procedure), total cavopulmonary connections (Fontan procedure) and one and a half ventricle correction in two cases. Age at operation averaged three years (range: 0.42-25 years) for the Glenn procedure and seven years (range: 3-14 years) for the Fontan procedure. There were 36 male patients (58%) and 26 female patients (42%). The most common indication for surgery was the single ventricle defect, present in 66% of patients. Associated lesions included: transposition of the great arteries in 16 patients (35.6%), bilateral superior vena cava in four patients (8.9%), situs ambigus in five patients (11%), situs inversus in another patient (2.2%), Ebstein disease in one patient (2.2) and coronary fistula in another patient (2.2%). Sub-aortic stenosis was present in one patient (2.2%). Palliative surgery was performed in all, but three patients (5%), before the Fontan procedure. RESULTS: Thirty two patients underwent bidirectional cavopulmonary anastomosis and thirty patients underwent cavopulmonary connections, total or 2nd stage. Mean cardiopulmonary bypass times were 50.6+/-21.9 minutes for the Glenn procedure and 88.5+/-26.3 minutes for the Fontan procedure. There was no intra-operative mortality, but two patients (3.2% (died in the first month after surgery; one due to failure of the Glenn circuit and sepsis and the other due to a low cardiac output syndrome and multi-organ dysfunction. Mean ventilation time was 5.2+/-1.7 hours for the Glenn operation and 6.2+/-3.2 hours for the Fontan operation. The mean length of stay in ICU was 3.4+/-2.8 days for patients undergoing the Glenn operation and 4.6+/-3.1 days for patients undergoing the Fontan operation and the mean length of hospital stay was 10.6+/-5.8 days for the Glenn operation and 19.1+/-12.6 days for the Fontan operation respectively. The mean follow up time was 4+/-2.1 years (minimum 0 years and maximum seven years), most patients being in NYHA class I. Epicardiac pacemakers were implanted in three patients due to arrhythmias. Two re-operations (6.7%) were needed, both in the same patient, after the Fontan procedure, this patient eventually died a few years after surgery. CONCLUSIONS: The immediate and mid term outcomes of pulmonary ventricle bypass operations can have excellent results. From our point of view there has been an improvement, namely in the use of the extracardiac conduit technique in the 2nd stage of the Fontan operation.