971 resultados para Removable partial denture. Dental impression technique. Mandible.Partially edentulous arch
Resumo:
The moisture content and its spatial distribution has a great influence on the durability properties of concrete structures. Several non-destructive techniques have been used for the determination of the total water content, but moisture distribution is difficult to determine. In this paper impedance spectroscopy is used to study the water distribution in concrete samples with controlled and homogeneously distributed moisture contents. The technique is suitable for the determination of water distribution inside the sample, using the appropriate equivalent circuits. It is shown that using the selected drying procedures there is no change in the solid phase of the samples, although the technique can only be used for the qualitative study of variations in the solid phase when samples are too thick. The results of this work show that for a wide range of concrete percentages of saturation, from full to 18 % saturation, practically all the pores keep at least a thin layer of electrolyte covering their walls, since the capacitance measurement results are practically independent of the saturation degree.
Resumo:
In this paper a new technique for partial product reduction based on the use of look-up tables for efficient processing is presented. We describe how to construct counter devices with pre-calculated data and their subsequent integration into the whole operation. The development of reduction trees organizations for this kind of devices uses the inherent integration benefits of computer memories and offers an alternative implementation to classic operation methods. Therefore, in our experiments we compare our implementation model with CMOS technology model in homogeneous terms.
Resumo:
Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.
Resumo:
Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.
Resumo:
An unabridged specimen of the work in its revised form was issued anonymously in 1902 under title "L'imprimerie hors l'Europe", but later withdrawn from circulation.
Resumo:
A new mesosuchian crocoddian from the Nova Olinda Member of the Crato Formation (Lower Cretaceous, Aptian) of north-eastern Brazil is described. Susisuchus anatoceps gen. et sp. nov. is the first crocodillan to be reported from this formation. It is represented by an incomplete, partially articulated skeleton: the skull and mandible, partial postcranial axial skeleton, forelimbs and portions of the osteodermal skeleton. Preservation of soft tissues includes the skin surrounding both forelimbs and the digits of the right hand. The state of preservation of the specimen suggests that it was incorporated into the basin as a desiccated carcass. Susisuchus anatoceps is one of the oldest crocodilians with a eusuchian-type dorsal shield, comprising a tetraserial paravertebral shield and, either side of this, two sagittal rows of accessory osteoderms. It also possesses amphicoelous thoracic, lumbar and caudal vertebrae. This combination of postcranial features have never before been seen in a crocodilian and warrant the erection of a new family within Mesosuchia: Susisuchidae. Taxonomically, S. anatoceps is similar to a number of Lower Cretaceous mesosuchians previously considered to have given rise to eusuchians, most notably the Glen Rose crocodilian and a new, but as yet undescribed crocodillan from the Lower Cretaceous Winton Formation of western Queensland, Australia. Preliminary preparation of the Winton crocodilian indicates that it may belong to Susisuchidae, supporting the hypotheses of interchange between the vertebrate faunas of South America and Australia during the Lower Cretaceous.
Resumo:
Different as-cast microstructures of an AlSi7Mg alloy were produced by controlling the solidification conditions. The as-cast grain size ranged from 1.4 mm to 160 mum and the morphology varied from dendritic to rosette-like to globular. The as-cast materials were then partially remelted and isothermally held at 580degreesC for microstructure evolution. The final microstructure depended on the initial as-cast microstructure and the isothermal holding time. After partial remelting and isothermal holding, coarse-grained dendritic structures were not able to evolve to a globular structure, while structures with medium sized dendritic grains evolved to a globular structure with a relatively large particle size after a long isothermal holding time. Fine-grained structures evolved to well-rounded globular grains within times ranging front 10 min to 5 min as the dendritic nature of the starting structure diminished. An empirical equation has been established to describe the relationship between the evolved microstructure and the as-cast microstructure. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
To study the phase relations in the Bi-2212 and Yb2O3 system, Bi2Sr2Ca1-xYbxCu2Oy thick films are prepared by partial melt processing via an intermediate reaction between Bi-2212 and Yb2O3. When Bi-2212 and Yb2O3 are partially melted and then slowly cooled, solid solutions of Bi2Sr2Ca1-xYbxCu2Oy form by reactions between liquid and solid phases which contain Yb. Following these reactions, Ca is partially replaced in Bi-2212 matrix and participates in the formation of secondary phases, such as Bi-free, (Ca, Sr)O-x and CaO. Variation of the Bi-2212-Yb2O3 ratios and processing parameters changes the balance between the phases and leads to different Yb:Ca ratios in the Bi-2212 matrix of processed thick films. When the partial melting process is optimized for each sample to minimize the growth of secondary phases, x = 0.42-0.46 for the samples prepared at pO(2) = 0.01 atm, x = 0.24-0.29 for the samples prepared at pO(2) = 0.21 atm, x = 0.18-0.23 for the samples prepared at pO(2) = 0.99 atm are obtained regardless to the starting compositions. It is found that superconducting properties of Bi2Sr2Ca1-xYbxCu2Oy thick films strongly depend on the processing conditions, because the conditions result in different Yb content in the Bi-2212 matrix and the volume fraction of the secondary phases. The highest T-c(0) of 77, 90 and 91 K were obtained for the samples processed at 0.01, 0.21 and 0.99 atm of O-2, respectively.
Resumo:
Given a partial K-4-design (X, P), if x is an element of X is a vertex which occurs in exactly one block of P, then call x a free vertex. In this paper, a technique is described for obtaining a cubic embedding of any partial K-4-design with the property that every block in the partial design contains at least two free vertices.
Resumo:
Due to complex field/tissue interactions, high-field magnetic resonance (MR) images suffer significant image distortions that result in compromised diagnostic quality. A new method that attempts to remove these distortions is proposed in this paper and is based on the use of transceiver-phased arrays. The proposed system uses, in the examples presented herein, a shielded four-element transceive-phased array head coil and involves performing two separate scans of the same slice with each scan using different excitations during transmission. By optimizing the amplitudes and phases for each scan, antipodal signal profiles can be obtained, and by combining both the images together, the image distortion can be reduced several fold. A combined hybrid method of moments (MoM)/finite element method (FEM) and finite-difference time-domain (FDTD) technique is proposed and used to elucidate the concept of the new method and to accurately evaluate the electromagnetic field (EMF) in a human head model. In addition, the proposed method is used in conjunction with the generalized auto-calibrating partially parallel acquisitions (GRAPPA) reconstruction technique to enable rapid imaging of the two scans. Simulation results reported herein for 11-T (470-MHz) brain imaging applications show that the new method with GRAPPA reconstruction theoretically results in improved image quality and that the proposed combined hybrid MoM/FEM and FDTD technique is. suitable for high-field magnetic resonance imaging (MRI) numerical analysis.
Resumo:
Este estudo objetiva encontrar a forma e dimensão de arcos dentais para definir a forma de um arco contínuo que possa ser utilizado na técnica lingual. A amostra foi composta de 70 indivíduos brasileiros, leucodermas, com oclusão normal natural, que apresentaram no mínimo quatro das seis chaves de oclusão de Andrews. Esta amostra possui 40% de indivíduos do sexo masculino (28 homens) e 60% do sexo feminino (42 mulheres) com idade média de 16,4a. Os modelos dos arcos dentais da maxila e mandíbula foram digitalizados (3D) e as imagens exportadas para o software Delcam Power SHAPE® 2010 (Birmingham, U.K.). Foram selecionados pontos nas superfícies linguais dos dentes e traçadas 14 medidas para determinar a forma e a dimensão do arco dental. O teste de Shapiro-Wilk possibilitou definir uma forma de arco pequeno utilizando o percentil 25% (P25%), um arco médio (média) e uma forma de arco grande pelo percentil 75% (P75%). O teste t-student comparou se houve uma diferença entre os sexos, e foram encontrados 12 tamanhos de arcos dentais (6 para o sexo feminino e 6 para o sexo masculino). Em todos os testes estatísticos foi adotado nível de significância de 5% (p<0,05). A partir dos resultados obtidos, foi possível definir uma forma de arco contínuo para ser utilizado na técnica Lingual Straight Wire (LSW) - parábola levemente achatada na região anterior - e, devido à similaridade entre alguns tamanhos de arcos dentais, encontrados pelo dimorfismo sexual, pôde ser elaborado um diagrama de arcos de maneira mais simplificada.
Resumo:
This study examines the effect of budgetary participation on departmental performance via budget adequacy, organisational commitment and role ambiguity. The responses of 108 budget preparers and budget users drawn from a cross-section of Malaysian local authorities, to a questionnaire survey were analysed by using mediation analysis, path analysis and Pearson Product-Moment Correlation technique. The results suggest that budget adequacy, organisational commitment, and role ambiguity are important links in the process. The results of this study suggest that the relationship between budget participation and departmental performance is statistically, significantly, positively and marginally correlated. Of more interest was the finding that budget adequacy, organisational commitment, and role ambiguity are important intervening variables in the relationship between budget participation and departmental performance. The test for mediation effect, demonstrated that budget adequacy, organisational commitment, and role ambiguity had partially mediated the relationship of budget participation and departmental performance. These three variables act as partial mediators when they significantly reduced or decreased the path coefficient of budget participation and departmental performance rather than eliminating the relationship. Furthermore, the test for direct and indirect effect of budget participation on departmental performance, suggests that budget participation predicted or affected departmental performance more strongly in the indirect way than it did in a direct way. This suggests that, even though the correlation between budget participation and departmental performance was significant, the path interpretation suggests that the correlation arose because budget participation was correlated with other variables that have direct effect upon departmental performance not budget participation itself directly predicted departmental performance. Therefore, there is enough evidence to suggest that budget participation of budget preparers and budget users affects departmental performance of Malaysian local authorities indirectly via budget adequacy, organisational commitment and role ambiguity. Among the indirect effects, the link between budget participation, budget adequacy, organisational commitment, role ambiguity and departmental performance may be the most important in term of this study’s contribution. The decomposition of the observed correlation between budget participation, budget adequacy, organisational commitment and role ambiguity showed that budget 3 participation of budget preparers and budget users of Malaysian local authorities in the budget setting has direct effect on budget adequacy, organisational commitment and role ambiguity. Budget adequacy and organisational commitment was directly related. However, the relationship of role ambiguity and organisational commitment in this study was indirectly related. This suggests that participation of budget preparers and budget users in the budget setting of Malaysian local authorities lead to decrease role ambiguity that provide adequate budgetary supports, which lead to increase organisational commitment and thus enhance departmental performance. In relation to the strength of the relationships of the variables undertaken for the study, the overall relationships between variables are significant and positively related except that of role ambiguity relationship. The relationships of role ambiguity with budget participation, budget adequacy, organisational performance and departmental performance are negatively related.