936 resultados para Reliability in automation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Non-invasive monitoring of respiratory muscle function is an area of increasing research interest, resulting in the appearance of new monitoring devices, one of these being piezoelectric contact sensors. The present study was designed to test whether the use of piezoelectric contact (non-invasive) sensors could be useful in respiratory monitoring, in particular in measuring the timing of diaphragmatic contraction.Methods: Experiments were performed in an animal model: three pentobarbital anesthetized mongrel dogs. The motion of the thoracic cage was acquired by means of a piezoelectric contact sensor placed on the costal wall. This signal is compared with direct measurements of the diaphragmatic muscle length, made by sonomicrometry. Furthermore, to assess the diaphragmatic function other respiratory signals were acquired: respiratory airflow and transdiaphragmatic pressure. Diaphragm contraction time was estimated with these four signals. Using diaphragm length signal as reference, contraction times estimated with the other three signals were compared with the contraction time estimated with diaphragm length signal.Results: The contraction time estimated with the TM signal tends to give a reading 0.06 seconds lower than the measure made with the DL signal (-0.21 and 0.00 for FL and DP signals, respectively), with a standard deviation of 0.05 seconds (0.08 and 0.06 for FL and DP signals, respectively). Correlation coefficients indicated a close link between time contraction estimated with TM signal and contraction time estimated with DL signal (a Pearson correlation coefficient of 0.98, a reliability coefficient of 0.95, a slope of 1.01 and a Spearman's rank-order coefficient of 0.98). In general, correlation coefficients and mean and standard deviation of the difference were better in the inspiratory load respiratory test than in spontaneous ventilation tests.Conclusion: The technique presented in this work provides a non-invasive method to assess the timing of diaphragmatic contraction in canines, using a piezoelectric contact sensor placed on the costal wall.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Evaluation of a French translation of the Addiction Severity Index (ASI) in 100 (78 male) alcoholic patients. METHOD: Validity of the instrument was assessed by measuring test-retest and interrater reliability, internal consistency and convergence and discrimination between items and scales. Concurrent validity was assessed by comparing the scores from the ASI with those obtained from three other clinimetric instruments. RESULTS: Test-retest reliability of ASI scores (after a 10-day interval) was good (r = 0.63 to r = 0.95). Interrater reliability was evaluated using six video recordings of patient interviews. Severity ratings assigned by six rates were significantly different (p < .05), but 72% of the ratings assigned by those who viewed the videos were within two points of the interviewer's severity ratings. Cronbach alpha coefficient of internal consistency varied from 0.58 to 0.81 across scales. The average item-to-scale convergent validity (r value) was 0.49 (range 0.0 to 0.84) for composite scores and 0.35 (range 0.00 to 0.68) for severity ratings, whereas discriminant validity was 0.11 on average (range-0.19 to 0.46) for composite scores and 0.12 (range-0.20 to 0.52) for severity ratings. Finally, concurrent validity with the following instruments was assessed: Severity of Alcoholism Dependence Questionnaire (40% shared variance with ASI alcohol scale), Michigan Alcoholism Screening Test (2% shared variance with ASI alcohol scale) and Hamilton Depression Rating Scale (31% shared variance with ASI psychiatric scale). CONCLUSIONS: The Addiction Severity Index covers a large scope of problems encountered among alcoholics and quantifies need for treatment. This French version presents acceptable criteria of reliability and validity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Few episodes of suspected infection observed in paediatric intensive care are classifiable without ambiguity by a priori defined criteria. Most require additional expert judgement. Recently, we observed a high variability in antibiotic prescription rates, not explained by the patients' clinical data or underlying diseases. We hypothesised that the disagreement of experts in adjudication of episodes of suspected infection could be one of the potential causes for this variability. During a 5-month period, we included all patients of a 19-bed multidisciplinary, tertiary, neonatal and paediatric intensive care unit, in whom infection was clinically suspected and antibiotics were prescribed ( n=183). Three experts (two senior ICU physicians and a specialist in infectious diseases) were provided with all patient data, laboratory and microbiological findings. All experts classified episodes according to a priori defined criteria into: proven sepsis, probable sepsis (negative cultures), localised infection and no infection. Episodes of proven viral infection and incomplete data sets were excluded. Of the remaining 167 episodes, 48 were classifiable by a priori criteria ( n=28 proven sepsis, n= 20 no infection). The three experts only achieved limited agreement beyond chance in the remaining 119 episodes (kappa = 0.32, and kappa = 0.19 amongst the ICU physicians). The kappa is a measure of the degree of agreement beyond what would be expected by chance alone, with 0 indicating the chance result and 1 indicating perfect agreement. CONCLUSION: agreement of specialists in hindsight adjudication of episodes of suspected infection is of questionable reliability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To demonstrate the validity and reliability of volumetric quantitative computed tomography (vQCT) with multi-slice computed tomography (MSCT) and dual energy X-ray absorptiometry (DXA) for hip bone mineral density (BMD) measurements, and to compare the differences between the two techniques in discriminating postmenopausal women with osteoporosis-related vertebral fractures from those without. METHODS: Ninety subjects were enrolled and divided into three groups based on the BMD values of the lumbar spine and/or the femoral neck by DXA. Groups 1 and 2 consisted of postmenopausal women with BMD changes <-2SD, with and without radiographically confirmed vertebral fracture (n=11 and 33, respectively). Group 3 comprised normal controls with BMD changes > or =-1SD (n=46). Post-MSCT (GE, LightSpeed16) scan reconstructed images of the abdominal-pelvic region, 1.25 mm thick per slice, were processed by OsteoCAD software to calculate the following parameters: volumetric BMD values of trabecular bone (TRAB), cortical bone (CORT), and integral bone (INTGL) of the left femoral neck, femoral neck axis length (NAL), and minimum cross-section area (mCSA). DXA BMD measurements of the lumbar spine (AP-SPINE) and the left femoral neck (NECK) also were performed for each subject. RESULTS: The values of all seven parameters were significantly lower in subjects of Groups 1 and 2 than in normal postmenopausal women (P<0.05, respectively). Comparing Groups 1 and 2, 3D-TRAB and 3D-INTGL were significantly lower in postmenopausal women with vertebral fracture(s) [(109.8+/-9.61) and (243.3+/-33.0) mg/cm3, respectively] than in those without [(148.9+/-7.47) and (285.4+/-17.8) mg/cm(3), respectively] (P<0.05, respectively), but no significant differences were evident in AP-SPINE or NECK BMD. CONCLUSION: the femoral neck-derived volumetric BMD parameters using vQCT appeared better than the DXA-derived ones in discriminating osteoporotic postmenopausal women with vertebral fractures from those without. vQCT might be useful to evaluate the effect of osteoporotic vertebral fracture status on changes in bone mass in the femoral neck.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This is an article about the theoretical model for assessing quality in health services proposed by Parasuraman, Zheitaml and Berry, in order to measure the degree of satisfaction of users. This model is based on the analysis of expectations and perceptions of users of health services, by means of five dimensions: tangibility, reliability, responsiveness, assurance and empathy. From the difference between what is expected by the user and the service offered, gaps or shortcomings are derived that may be the main obstacle for users to perceive the provision of such services with quality. It was observed that the use of the psychometric scale called Service Quality (SERVQUAL) in some studies about satisfaction, obtained very favorable results in the institutions in which it was employed. The analysis revealed the need to improve the existing models of evaluation, as well as the importance of measuring user satisfaction in health institutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Vascular reconstructions are becoming challenging due to the comorbidity of the aging population and since the introduction of minimally invasive approaches. Many sutureless anastomosis devices have been designed to facilitate the cardiovascular surgeon's work and the vascular join (VJ) is one of these. We designed an animal study to assess its reliability and long-term efficacy. METHODS: VJ allows the construction of end-to-end and end-to-side anastomoses. It consists of two metallic crowns fixed to the extremity of the two conduits so that vessel edges are joined layer by layer. There is no foreign material exposed to blood. In adult sheep both carotid arteries were prepared and severed. End-to-end anastomoses were performed using the VJ device on one side and the classical running suture technique on the other side. Animals were followed-up with Duplex-scan every 3 months and sacrificed after 12 months. Histopathological analysis was carried out. RESULTS: In 20 animals all 22 sutureless anastomoses were successfully completed in less than 2 min versus 6 +/- 3 min for running suture. Duplex showed the occlusion of three controls and one sutureless anastomosis. Two controls and one sutureless had stenosis >50%. Histology showed very thin layer of myointimal hyperplasia (50 +/- 10 microm) in the sutureless group versus 300 +/- 27 microm in the control. No significant inflammatory reaction was detected. CONCLUSIONS: VJ provides edge-to-edge vascular repair that can be considered the most physiological way to restore vessel continuity. For the first time, in healthy sheep, an anastomotic device provided better results than suture technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To translate and culturally adapt to Brazil the scale Pain Assessment in Advanced Dementia(PAINAD).Method: The cultural adaptation process followed the methodology of a theorical reference, in five steps: translation to Brazilian Portuguese, consensual version of translations, back-translation to the original language, revision by a committee of specialists in the field and a equivalency pre-test. The instrument was assessed and applied by 27 health professionals in the last step. Results: The Escala de Avaliação de Dor em Demência Avançada was culturally adapted to Brazil and presented semantic equivalency to the original, besides clarity, applicability and easy comprehension of the instrument items. Conclusion: This process secured the psychometric properties as the reliability and content validity of the referred scale.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the internal consistency of the version of the Michigan Alcoholism Screening Test – Geriatric Version (MAST-G) instrument, translated and adapted for Brazil. Method: This was a descriptive, cross-sectional study. Data were collected through a demographic questionnaire, the ICD-10 and the MAST-G, following the steps of translation and cultural adaptation. One hundred eleven elderly in the city of São Carlos, SP, Brazil were interviewed. Results: The mean age of those interviewed was 70 years, with 45% men and 55% women, with the mean education of three years; 92% resided with family; 48% of the subjects consumed alcoholic beverages. The MAST-G presented a good level of reliability, with Cronbach’s α = 0.7873, and good levels of sensitivity and specificity with a cutoff score of five positive responses. Conclusion: The Brazilian version of the MAST-G presented internal consistency values similar to the original English version,showing it to be adequate for use in the national context.





Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective Developing an instrument to evaluate the performance of primary health care in the leprosy control actions, from the perspective of users and do the face and content validation. Method This is a methodological study carried out in four stages: development of instrument, face and content validation, pre-test, and analysis of test-retest reliability. Results The initial instrument submitted to the judgment of 15 experts was composed of 157 items. The face and content validation and pre-test of instrument were essential for the exclusion of items and adjustment of instrument to evaluate the object under study. In the analysis of test-retest reliability, the instrument proved to be reliable. Conclusion The instrument is considered adequate, but further studies are needed to test the psychometric properties.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To analyze the scientific production about the validity and reliability of the Manchester Triage System (MTS) protocol. METHOD A descriptive study of an integrative literature review. Articles on the validity and reliability of the MTS developed with children and adults published between 1999 and 2013 were included. RESULTS 14 articles were selected from a total of 8438, nine of validity and five of reliability. The reliability of the MTS ranged from moderate to almost perfect, with higher intra-evaluation. Regarding validity, the results seem to point to equivalent and satisfactory sensibility and specificity levels of the MTS. The instrument proved to be a good predictor of the need for hospitalization and of hospital mortality. CONCLUSION The reliability and validity of the MTS obtained in the studies is varied. It is recommended that new studies indicate necessary modifications to the MTS so that it is more safely used by nurses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to carry out the cross-cultural adaptation of the Caregiver Reaction Assessment CRA for use in Brazil with informal caregivers of dependent elderly METHOD A methodological study, of five steps: initial translation, synthesis of translations, retro-translation, evaluation by a judge committee and a pre-test, with 30 informal caregivers of older persons in Fortaleza, Brazil. Content validity was assessed by five experts in gerontology and geriatrics. The cross-cultural adaptation was rigorously conducted, allowing for inferring credibility. RESULTS The Brazilian version of the CRA had a simple and fast application (ten minutes), easily understood by the target audience. It is semantically, idiomatically, experimentally and conceptually equivalent to the original version, with valid content to assess the burden of informal caregivers for the elderly (Content Validity Index = 0.883). CONCLUSION It is necessary that other psychometric properties of validity and reliability are tested before using in care practice and research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The goal of this study was to validate a French version of the Interpersonal Reactivity Index (IRI), a self-report questionnaire comprised of four subscales assessing affective (empathic concern and personal distress) and cognitive (fantasy and perspective taking) components of empathy. To accomplish this, 322 adults (18 to 89 years) completed the French version of the IRI (F-IRI). A confirmatory factor analysis confirmed the four-factor structure of the original IRI. The F-IRI showed good scale score reliability, test-retest reliability, and convergent validity, tested with the French version of the Empathy Quotient. These findings confirmed the reliability and validity of the F-IRI and suggest that the F-IRI is a useful instrument to measure self-reported empathy. In addition, we observed sex and age differences consistent with findings in the literature. Women reported higher scores in empathic concern and fantasy than men. Older adults reported less personal distress and less fantasy. (PsycINFO Database Record (c) 2013 APA, all rights reserved)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract OBJECTIVE To analyze the evidences of construct validity of the Katz Index for the retrospective assessment of activities of daily living (ADL) by informants, to assist neuropathological studies in the elderly. METHOD A cross-sectional study analyzed the functional ability of ADL measure by the Katz Index, of 650 cases randomly selected from the Brazilian Brain Bank of the Ageing Brain Study Group (BBBABSG) database. Sample was divided in two subsamples for the analysis (N=325, each) and then stratified according to cognitive decline assessed by the Clinical Dementia Rating Scale (CDR). Factor analyses with calculations of internal consistency and invariance were performed. RESULTS Factor analysis evidenced a unidimensional instrument with optimal internal consistency, in all subgroups. Goodness of fit indices were obtained after two treatments of covariance, indicating adequacy of the scale for assessing ADL by informants. The scale is invariant to cognitive decline meaning that it can be used for subjects with or without cognitive impairment. CONCLUSION Katz Index is valid for the retrospective assessment of basic ADL by informants, with optimal reliability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT Objective To analyze the interrater reliability of NAS among critical care nurses and managers in an ICU. Method This was a methodological study performed in an adult, general ICU in Norway. In a random selection of patients, the NAS was scored on 101 patients by three raters: a critical care nurse, an ICU physician and a nurse manager. Interrater reliability was analyzed by agreement between groups and kappa statistics. Results The mean NAS were 88.4 (SD=16.2) and 88.7 (SD=24.5) respectively for the critical care nurses and nurse managers. A lower mean of 83.7 (SD=21.1) was found for physicians. The 18 medical interventions showed higher agreement between critical care nurses and physicians (85.6%), than between critical care nurses and nurse managers (78.7). In the five nursing activities the Kappa-coefficients were low for all activities in all compared groups. Conclusion The study indicated a satisfactory agreement of nursing workload between critical care nurses and managers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: This study examined the reliability of explicit guidelines developed using the RAND-UCLA appropriateness method. METHODS: The appropriateness of over 400 indications for colonoscopy was rated by two multispecialty expert panels (United States and Switzerland). A nine-point scale was used, which was consolidated into three categories of appropriateness: appropriate, uncertain, inappropriate. The distribution of appropriateness ratings between the two panels and the intrapanel and interpanel agreement for categories of appropriateness were calculated for all possible indications. Similar statistics were calculated for a series of 577 primary care patients referred for colonoscopy in Switzerland. RESULTS: Over 80% of all indications (348) could be directly compared. The proportions of indications classified as appropriate, uncertain, or inappropriate were 28.4%, 24.7%, 46.6% and 33.0%, 23.0%, 44.0% for the U.S. and the Swiss panels, respectively. Interpanel agreement was excellent for all the possible indications (kappa value: 0.75) and lower for actual cases (kappa value: 0.51) because of lower agreement for the most frequently encountered indications. CONCLUSIONS: Good agreement between the two sets of criteria was found, pointing to the reliability of the method. Partial disagreement occurred essentially for a few, albeit frequently encountered, indications for use of colonoscopy in cases of uncomplicated lower abdominal pain or constipation.