998 resultados para Radiology technicians


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cerebral perfusion-weighted imaging (PWI) in neonates is known to be technically difficult and there are very few published studies on its use in preterm infants. In this paper, we describe one convenient method to perform PWI in neonates, a method only recently used in newborns. A device was used to manually inject gadolinium contrast material intravenously in an easy, quick and reproducible way. We studied 28 newborn infants, with various gestational ages and weights, including both normal infants and those suffering from different brain pathologies. A signal intensity-time curve was obtained for each infant, allowing us to build perfusion maps. This technique offered a fast and easy method to manually inject a bolus gadolinium contrast material, which is essential in performing PWI in neonates. Cerebral PWI is technically feasible and reproducible in neonates of various gestational age and with various pathologies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To study the anti-tumoral effect of sunitinib eluting beads in the rabbit VX2 tumor modelMaterials: VX2 tumor were implanted in the left liver lobe of New-Zealand white rabbits. Seven animals received 0.2ml of DC Beads loaded with 6mg of sunitinb (group 1), 6 animals received 0.2ml of DC Beads (group 2) and 6 animals received NaCl 0.9% intra arterially in the left hepatic artery. One animal in each group was sacrificed at 24 hours and the others were left to survive. Liver enzyme were measured daily. In group 1 plasmatic sunitinib concentration were measured daily by LC MS/MS tandem mass spectroscopy. At day 15 all living animals were sacrficed. After sacrifice, or premature euthanasia the livers were harvested for determination of the VEGF receptor tyrosine kinase activity by western blot and histopathological examination.Results: In group 1, no animal died during follow-up. In group 2 and 3, respectively 2 and 3 animals died during follow-up. In group 1 plasmatic sunitinib level remained under therapeutic concentration during the whole experiment. There was an evident lack of phosphorylation of the RTK In group 1 and there was an augmentation of the RTK phosphorylation in group 2 at 24 hours. No difference in RTK activity was noticable at 15 days. From the histopathological point of view it was unpossible to differentiate treatment induced from spontaneous necrosis of tumors.Conclusions: Administration of sunitinib eluting Beads in VX2 carrying rabbits inhibits the activation of RTK's triggered by ischemia. It also seems to prolong survival of the treated animals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: The purpose of this study was the investigation of the impact of real-time adaptive motion correction on image quality in navigator-gated, free-breathing, double-oblique three-dimensional (3D) submillimeter right coronary magnetic resonance angiography (MRA). MATERIALS AND METHODS: Free-breathing 3D right coronary MRA with real-time navigator technology was performed in 10 healthy adult subjects with an in-plane spatial resolution of 700 x 700 microm. Identical double-oblique coronary MR-angiograms were performed with navigator gating alone and combined navigator gating and real-time adaptive motion correction. Quantitative objective parameters of contrast-to-noise ratio (CNR) and vessel sharpness and subjective image quality scores were compared. RESULTS: Superior vessel sharpness, increased CNR, and superior image quality scores were found with combined navigator gating and real-time adaptive motion correction (vs. navigator gating alone; P < 0.01 for all comparisons). CONCLUSION: Real-time adaptive motion correction objectively and subjectively improves image quality in 3D navigator-gated free-breathing double-oblique submillimeter right coronary MRA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Portal vein embolization (PVE) has been developed to increase the size of the future remnant liver (FRL) left in place after major hepatectomy, thus reducing the risk of postoperative liver insufficiency. PVE consist in embolizing preoperatively portal branches of the segments that will be resected. Indication is based on preoperative measurements of the FRL by computed tomography and its ratio with either the theoretical liver volume or by direct measurement of the functional liver volume. After PVE, the volume and function of the FRL increases in 3 to 6 weeks, permitting extensive resections in patients otherwise contraindicated for liver resection. The PVE technique is variable from one center to another; however n-butyl-cyano-acrylate provides an interesting compromise between hypertrophy rate and procedure risk.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Performing a post-mortem multidetector CT (MDCT) scan has already become routine in some institutes of forensic medicine. To better visualize the vascular system, different techniques of post-mortem CT-angiography have been explored, which can essentially be divided into partial- and whole-body angiography techniques. Probably the most frequently applied technique today is the so-called multiphase post-mortem CT-angiography (MPMCTA) a standardized method for investigating the vessels of the head, thorax and abdomen. Different studies exist, describing its use for medicolegal investigations, and its advantages as well as its artefacts and pitfalls. With the aim to investigate the performance of PMCTA and to develop and validate techniques, an international working group was created in 2012 called the "Technical Working Group Post-mortem Angiography Methods" (TWGPAM). Beyond its primary perspective, the goals of this group include creating recommendations for the indication of the investigation and for the interpretation of the images and to distribute knowledge about PMCTA. This article provides an overview about the different approaches that have been developed and tested in recent years and an update about ongoing research in this field. It will explain the technique of MPMCTA in detail and give an outline of its indications, application, advantages and limitations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multidisciplinary management of colorectal liver metastases allows an increase of about 20% in the resection rate of liver metastases. It includes chemotherapy, interventional radiology and surgery. In 2013, the preliminary results of the in-situ split of the liver associated with portal vein ligation (ALLPS) are promising with unprecedented mean hypertrophy up to 70% at day 9. However, the related morbidity of this procedure is about 40% and hence should be performed in the setting of study protocol only. For pancreatic cancer, the future belongs to the use of adjuvant and neo adjuvant therapies in order to increase the resection rate. Laparoscopic and robot-assisted surgery is still in evolution with significant benefits in the reduction of cost, hospital stay, and postoperative morbidity. Finally, enhanced recovery pathways (ERAS) have been validated for colorectal surgery and are currently assessed in other fields of surgery like HPB and upper GI surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose was to evaluate the influence of radiologist's experience on the diagnostic yield and complications of a percutaneous liver biopsy (PLB) method. Six hundred patients underwent an ultrasound-guided PLB by an inexperienced operator in 25.2% of cases (experience of less than 15 percutaneous liver biopsies performed alone--group I) or by an experienced operator (experience of more than 150 percutaneous liver biopsies--group II). The two groups were well-matched with respect to sex, age, percentage with viral hepatitis without histological cirrhosis, number of needle passes, history of liver biopsy and pain before the biopsy. A histological diagnosis was available in 97.3% of cases without any significant difference between the two groups ( P=0.25). However, group II samples were significantly longer and contained more portal tracts ( P=0.01). Pain was mild immediately and 6 h after the biopsy, without significant difference between both groups. Eight vasovagal reactions (five in group II) and one arteriobiliary fistula (in group II) occurred. With the method of PLB used for this study, operator's experience did not influence either the final histological diagnosis or the degree of pain suffered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: This study analyzes CT examinations in Switzerland. MATERIALS AND METHODS: Using different sources (administrative data on the equipment, a 1998 nationwide inquiry into practices, and data provided by the Swiss University Hospitals of Basel, Zurich, and Lausanne), we determined the frequency of CT examinations (hospitals and private radiologists) in 1998 according to different descriptive variables and studied the progression in CT use over time. RESULTS: CT scanners increased by 7% between 1998 and 2004. The average annual number of CT examinations in 1998 was 46.3/1000 population, 3.4% of all radiological examinations in Switzerland in 1997-1998. The most frequent examination was CT of the skull (24%), while private radiology institutes perform more CTs of the spine. More CT examinations were performed for men than for women (sex ratio M/F=1.17). The average annual increase in CT in Swiss hospitals varied from 8% for Basel to 18% for Lausanne. Finally, the proportion of pediatric examinations was 5%; their numbers appear to be stabilizing. CONCLUSION: There is a significant increase in CT examinations. It is hoped that our study will heighten awareness among doctors of CT examinations in order to optimize their use.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To present in vitro loading and release characteristics of idarubicin with ONCOZENE (CeloNova BioSciences, Inc, San Antonio, Texas) drug-eluting embolic (DEE) agents and in vivo pharmacokinetics data after transarterial chemoembolization with idarubicin-loaded ONCOZENE DEE agents in patients with hepatocellular carcinoma. MATERIALS AND METHODS: Loading efficacy of idarubicin with ONCOZENE DEE agents 100 µm and DC Bead (Biocompatibles UK Ltd, Farnham, United Kingdom) DEE agents 100-300 µm was monitored at 10, 20, and 30 minutes loading time by high-pressure liquid chromatography. A T-apparatus was used to monitor the release of idarubicin from the two types of DEE agents over 12 hours. Clinical and 24-hour pharmacokinetics data were recorded after transarterial chemoembolization with idarubicin-loaded ONCOZENE DEE agents in four patients with unresectable hepatocellular carcinoma. RESULTS: Idarubicin loading in ONCOZENE DEE agents was > 99% at 10 minutes. Time to reach 75% of the release plateau level was 37 minutes ± 6 for DC Bead DEE agents and 170 minutes ± 19 for ONCOZENE DEE agents both loaded with idarubicin 10 mg/mL. After transarterial chemoembolization with idarubicin-loaded ONCOZENE DEE agents, three partial responses and one complete response were observed with only two asymptomatic grade 3 biologic adverse events. Median time to maximum concentration for idarubicin in patients was 10 minutes, and mean maximum concentration was 4.9 µg/L ± 1.7. Mean area under the concentration-time curve from 0-24 hours was equal to 29.5 µg.h/L ± 20.5. CONCLUSIONS: ONCOZENE DEE agents show promising results with very fast loading ability, a favorable in vivo pharmacokinetics profile with a sustained release of idarubicin during the first 24 hours, and encouraging safety and responses. Histopathologic and clinical studies are needed to evaluate idarubicin release around the DEE agents in tumor tissue and to confirm safety and efficacy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Forensic imaging and especially forensic radiology is a new trend in forensic medicine. More and more forensic institutes set up their own CT-scanner in order to perform postmortem cross-sectional imaging. Due to this trend, a new subspecialty was born: the forensic radiology. To image the vascular system after death, a postmortem CT- angiography can be performed. Methods and materials: In the Institute of Forensic Medicine in Lausanne, a science group has been created with specialists of different medical fields that has set up a new technique of forensic CT-angiography. The method consists in the creation of a postmortem circulation by the use of a modified heart lung machine. As circulating liquid Angiofil, an oily contrast agent, is injected. Results: With the aid of this technique, the whole vascular system of a deceased person can be imaged in detail without autopsy. The circulating contrast allows demonstrating the vascular system when it is under pressure, similarly to living patients. First experiences showed, that vascular pathologies such as cardiac tamponade and aortic dissection can be well demonstrated. Since the oily Angiofil strictly remains in the intravascular space, no artifacts had been observed during the CT-examination and the later performed autopsy. Conclusion: Post-mortem dynamic CT angiography is of great advantage in forensic pathology, because the detailed mapping of the entire vascular system is almost impossible with conventional autopsy tools.