924 resultados para PL spectroscopy
Resumo:
Highly charged peptides are important components of the immune system and belong to an important family of antibiotics. Although their therapeutic activity is known, most of the molecular level mechanisms are controversial. A wide variety of different approaches are usually applied to understand their mechanisms, but light scattering techniques are frequently overlooked. Yet, light scattering is a noninvasive technique that allows insights both on the peptide mechanism of action as well as on the development of new antibiotics. Dynamic light scattering (DLS) and static light scattering (SLS) are used to measure the aggregation process of lipid vesicles upon addition of peptides and molecular properties (shape, molecular weight). The high charge of these peptides allows electrostatic attraction toward charged lipid vesicles, which is studied by zeta potential (zeta-potential) measurements. Copyright (c) 2008 European Peptide Society and John Wiley & Sons, Ltd.
Resumo:
The adduct TRIMEB:Eu(BTA)(3)center dot 2H(2)O was prepared and primarily characterized by photoluminescence (PL), and compared with free Eu(BTA)(3)center dot 2H(2)O. Both spectra show the Eu3+ ion emission, with subtle differences between lines for the free and encapsulated complex. The temperature dependence and chemical stability were studied, taking into account (in the latter case) the PL changes with time. The use of this new material as the emissive layer in OLEDs was tested by its successful incorporation into a device, using a conductive polymer as host. The use of the TRIMEB adduct increased the stability of the device (as compared with the free Eu complex). (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
This study aimed to investigate the pharmacokinetics of a hematoporphyrin derivative in colonic tumors induced by dimethylhydrazine and adjacent normal colon in Wistar rats using an in vivo fluorescence spectroscopy technique. In conventional clinical application of photodynamic therapy, the interval between photosensitizer (PS) administration and lesion illumination is often standardized without taking into account variations due to the type or localization of the tumor and intrinsic differences in the microcirculation and vascular permeability of each target organ. The analysis of the fluorescence spectra was based on the intensity of porphyrin emission band centered at around 620nm in normal colon and colon tumors. The photosensitizer fluorescence intensity rapidly grew for carcinoma and normal colon, reaching the maximum values 1 and 3 hours after PS injection, respectively. Data presented here allow us to verify that the best compromise between selectivity and drug concentration for colon carcinoma in rats took place in the interval between 1 to 4 h after PS injection.
Resumo:
Local structure around Fe ions on Pb(Fe1/2Nb1/2)O-3 ceramics was probed by x-ray absorption spectroscopy in order to settle the controversies about its structure. It is observed that the shell structure around Fe atoms exhibits a monoclinic local symmetry at 130 and 230 K, tetragonal local symmetry at room temperature, and cubic local symmetry at 410 K. Independently of the coordination, temperature, or symmetry, Fe-O mean bond-length does not vary significantly. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4709490]
Resumo:
In this work, the energy response functions of Si(Li), SDD and CdTe detectors were studied in the mammographic energy range through Monte Carlo simulation. The code was modified to take into account carrier transport effects and the finite detector energy resolution. The results obtained show that all detectors exhibit good energy response at low energies. The most important corrections for each detector were discussed, and the corrected mammographic x-ray spectra obtained with each one were compared. Results showed that all detectors provided similar corrected spectra, and, therefore, they could be used to accurate mammographic x-ray spectroscopy. Nevertheless, the SDD is particularly suitable for clinic mammographic x-ray spectroscopy due to the easier correction procedure and portability. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
This paper describes the effect of using different titanium precursors on the synthesis and physical properties of SrTiO3 powders obtained by microwave-assisted hydrothermal method. X-ray diffraction measurements, X-ray absorption near-edge structure (XANES) spectroscopy, field emission scanning electron microscopy (FE-SEM), and high-resolution transmission electron microscopy (HRTEM) were carried out to investigate the structural and optical properties of the SrTiO3 spherical and cubelike-shaped particles. The appropriate choice of the titanium precursor allowed the control of morphological and photoluminescence (PL) properties of SrTiO3 compound. The PL emission was more intense in SrTiO3 samples composed of spherelike particles. This behavior was attributed to the existence of a lower amount of defects due to the uniformity of the spherical particles.
Resumo:
The synthesis and structural characterization of a europium complexed fluorene-bipyridine copolymer are described. A level of ion insertion of 80% in molar basis was achieved, and theoretical calculations showed that it required a twist of 179 degrees (49 kJ) between the pyridine units. Spectroscopy data showed that no electronic coupling between the main backbone and the complexation sites had occurred, but these hindered the interchain aggregation observed in the non complexed polymer. Preliminary electroluminescence studies showed that the EL and PL spectra are consistent, and that the ion had a trapping effect in the charge transport. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
This work investigates pure ionic liquids (ILs) derived from an imidazolium ring with different carbonic chains and halides or bis(trifluoromethanesulfonilimide) (TFSI-) as anions, using X-ray absorption near edge spectroscopy (XANES) at different energies (N, S, O, F, and Cl edges) to probe the interionic interactions. XANES data show that the interaction with the anion is weaker when the cation is an imidazolium than when the salt is formed by smaller cations, as lithium, independently of the length of the carbonic chain attached to the imidazolium cation. The results also show that, for all studied as, it is not observed any influence of the anion on the XANES spectra of the cation, nor the opposite. 1-Methylimidazolium with Cl-, a small and strongly coordinating anion, presents in the N K XANES spectrum a splitting of the band corresponding to nitrogen in the imidazolic ring, indicating two different chemical environments. For this cation with TFSI-, on the contrary, this splitting was not observed, showing that the anion has a weaker interaction with the imidazolic ring, even without a lateral carbonic chain.
Resumo:
In this work, barium zirconate (BaZrO3) ceramics synthesized by solid state reaction method and sintered at 1670 degrees C for 4 h were characterized by X-ray diffraction (XRD), Rietveld refinement, and Fourier transform infrared (FT-IR) spectroscopy. XRD patterns, Rietveld refinement data and FT-IR spectra which confirmed that BaZrO3 ceramics have a perovskite-type cubic structure. Optical properties were investigated by ultraviolet-visible (UV-vis) absorption and photoluminescence (PL) measurements. UV-vis absorption spectra suggested an indirect allowed transition with the existence of intermediary energy levels within the band gap. Intense visible green PL emission was observed in BaZrO3 ceramics upon excitation with a 350 nm wavelength. This behavior is due to a majority of deep defects within the band gap caused by symmetry breaking in octahedral [ZrO6] clusters in the lattice. The microwave dielectric constant and quality factor were measured using the method proposed by Hakki-Coleman. The dielectric resonator antenna (DRA) was investigated experimentally and numerically using a monopole antenna through an infinite ground plane and Ansoft's high frequency structure simulator software, respectively. The required resonance frequency and bandwidth of DRA were investigated by adjusting the dimension of the same material. (C) 2011 Elsevier Ltd and Techna Group S.r.l. All rights reserved.
Resumo:
Pulse repetition rates and the number of laser pulses are among the most important parameters that do affect the analysis of solid materials by laser induced breakdown spectroscopy, and the knowledge of their effects is of fundamental importance for suggesting analytical strategies when dealing with laser ablation processes of polymers. In this contribution, the influence of these parameters in the ablated mass and in the features of craters was evaluated in polypropylene and high density polyethylene plates containing pigment-based PbCrO4. Surface characterization and craters profile were carried out by perfilometry and scanning electron microscopy. Area, volume and profile of craters were obtained using Taylor Map software. A laser induced breakdown spectroscopy system consisted of a Q-Switched Nd:YAG laser (1064 nm, 5 ns) and an Echelle spectrometer equipped with ICCD detector were used. The evaluated operating conditions consisted of 10, 25 and 50 laser pulses at 1, 5 and 10 Hz, 250 mJ/pulse (85 J cm(-2)), 2 mu s delay time and 6 mu s integration time gate. Differences in the topographical features among craters of both polymers were observed. The decrease in the repetition rate resulted in irregular craters and formation of edges, especially in polypropylene sample. The differences in the topographical features and ablated masses were attributed to the influence of the degree of crystallinity, crystalline melting temperature and glass transition temperature in the ablation process of the high density polyethylene and polypropylene. It was also observed that the intensities of chromium and lead emission signals obtained at 10 Hz were two times higher than at 5 Hz by keeping the number of laser pulses constant. (C) 2011 Elsevier B. V. All rights reserved.
Resumo:
This work reports the analytical application of surface-enhanced Raman spectroscopy (SERS) in the trace analysis of organophosphorous pesticides (trichlorfon and glyphosate) and model organophosphorous compounds (dimethyl methylphosphonate and o-ethyl methylphosphonothioate) bearing different functional groups. SERS measurements were carried out using Ag nanocubes with an edge square dimension of ca. 100 nm as substrates. Density functional theory (DFT) with the B3LYP functional was used for the optimization of ground state geometries and simulation of Raman spectra of the organophosphorous compounds and their silver complexes. Adsorption geometries and marker bands were identified for each of the investigated compound. Results indicate the usefulness of SERS methodology for the sensitive analyses of organophosphorous compounds through the use of vibrational spectroscopy.
Resumo:
Herein, it was investigated for the first time the electro-oxidation of ethanol on Pt and PtRu electrodeposits in acidic media by using in situ surface enhanced infrared absorption spectroscopy with attenuated total reflection (ATR-SEIRAS). The experimental setup circumvents the weak absorbance signals related to adsorbed species, usually observed for rough, electrodeposited surfaces, and allows a full description of the CO coverage with the potential for both catalysts. The dynamics of adsorption-oxidation of CO was accessed by ATR-SEIRAS experiments (involving four ethanol concentrations) and correlated with expressions derived from a simple kinetic model. Kinetic analysis suggests that the growing of the CO adsorbed layer is nor influenced by the presence of Ru neither by the concentration of ethanol. The results suggest that the C-C scission is not related to the presence of Ru and probably happens at Pt sites.
Resumo:
Frequency-dependent electroluminescence and electric current response spectroscopy were applied to polymeric light-emitting electrochemical cells in order to obtain information about the operation mechanism regimes of such devices. Three clearly distinct frequency regimes could be identified: a dielectric regime at high frequencies; an ionic transport regime, characterized by ionic drift and electronic diffusion; and an electrolytic regime, characterized by electronic injection from the electrodes and electrochemical doping of the conjugated polymer. From the analysis of the results, it was possible to evaluate parameters like the diffusion speed of electronic charge carriers in the active layer and the voltage drop necessary for operation. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4752438]
Resumo:
The stability of oil-in-water (O/W) emulsions used as metalworking fluids is a key factor for the economical and environmental balance of the entire metalworking process because used and broken fluids must be recycled or disposed. In this study, the ability of turbidimetric spectroscopy in the ultraviolet and visible light range to detect metalworking fluids destabilization was evaluated. Destabilization was achieved by adding calcium chloride, thus achieving accelerated aging, which leads to coalescence, creaming, and complete emulsion separation. The stability of the metalworking fluids at 5% volumetric concentration in deionized water was monitored using a spectroscopic turbidimeter composed of an optical probe for in-line measurements. Destabilization was also monitored by measuring the vertical profile of backscattered and transmitted light. The results of this offline measurement system were compared with those from the in-line spectroscopic sensor, indicating that the latter can provide local, real-time information on emulsion destabilization, thus enabling control actions.
Resumo:
In this work we report studies of the photoluminescence emission in samples based on Si/SiOx films deposited by the Pulsed Electron Beam Ablation (PEBA) technique. The samples were prepared at room temperature using targets with different Si/SiO2 concentrations. The samples were characterized using X-ray Absorption Edge Spectroscopy (XANES) at the Si-K edge, Raman spectroscopy, Photoluminescence (PL) and X-ray Photoelectron Spectroscopy (XPS). The concentration of a-Si and nc-Si in the film was dependent on the silicon concentration in the target. It was also observed that the PL is strongly dependent on the structural amorphous/crystalline arrangement. Crown Copyright (C) 2011 Published by Elsevier B.V. All rights reserved.