963 resultados para Modified Information Criteria


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new immunosensor is presented for human chorionic gonadotropin (hCG), made by electrodepositing chitosan/gold-nanoparticles over graphene screen-printed electrode (SPE). The antibody was covalently bound to CS via its Fc-terminal. The assembly was controlled by electrochemical Impedance Spectroscopy (EIS) and followed by Fourier Transformed Infrared (FTIR). The hCG-immunosensor displayed linear response against the logarithm-hCG concentration for 0.1–25 ng/mL with limit of detection of 0.016 ng/mL. High selectivity was observed in blank urine and successful detection of hCG was also achieved in spiked samples of real urine from pregnant woman. The immunosensor showed good detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemical sensors and biosensors are widely used to detect various kinds of protein target biomolecules. Molecularly Imprinted Polymers (MIPs) have raised great interest in this area, because these act as antibody-like recognition materials, with high affinity to the template molecule. Compared to natural antibodies, these are also of lower cost and higher stability. There are different types of supports used to carry MIP materials, mostly of these made of gold, favourably assembled on a Screen Printed Electrode (SPE) strategy. For this work a new kind of support for the sensing layer was developed: conductive paper. This support was made by modifying first cellulose paper with paraffin wax (to make it waterproof), and casting a carbon-ink on it afterwards, to turn it conductive. The SPAM approach previously reported in1 was employed herein to assemble to MIP sensing material on the conductive paper. The selected charged monomers were (vinylbenzyl) trimethlammonium chloride (positive charge) or vinylbenzoic acid (negative charge), used to generate binding positions with single-type charge (positive or negative). The non-specific binding area of the MIP layer was assembled by chronoamperometry-assisted polymerization (at 1 V, for 60, 120 or 180 seconds) of vinylbenzoate, cross-linked with ethylene glycol vinyl ether. The BSA biomolecules lying within the polymeric matrix were removed by Proteinase K action. All preparation stages of the MIP assembly were followed by FTIR, Raman spectroscopy and, electrochemical analysis. In general, the best results were obtained for longer polymerization times and positively charged binding sites (which was consistent with a negatively-charged protein under physiological pH, as BSA). Linear responses against BSA concentration ranged from 0.005 to 100 mg/mL, in PBS buffer standard solutions. The sensor was further calibrated in standard solutions that were prepared in synthetic or real urine, and the analytical response became more sensitive and stable. Compared to the literature, the detection capability of the developed device is better than most of the reported electrodes. Overall, the simplicity, low cost and good analytical performance of the BSA SPE device, prepared with positively charged binding positions, seems a suitable approach for practical application in clinical context. Further studies with real samples are required, as well as gathering with electronic-supporting devices to allow on-site readings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper formulates a novel expression for entropy inspired in the properties of Fractional Calculus. The characteristics of the generalized fractional entropy are tested both in standard probability distributions and real world data series. The results reveal that tuning the fractional order allow an high sensitivity to the signal evolution, which is useful in describing the dynamics of complex systems. The concepts are also extended to relative distances and tested with several sets of data, confirming the goodness of the generalization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO - A preocupação com os conhecimentos, atitudes, crenças e práticas, no que concerne à utilização de radiações ionizantes para fins de diagnóstico, e a sensibilização de todos os agentes envolvidos, médicos, técnicos, físicos, utentes e responsáveis pela Saúde Publica, relativamente aos níveis de radiação emitida nos exames de Tomografia Computorizada (TC), assume particular importância no domínio da Saúde Pública, na medida em que é necessário influenciar o desenvolvimento de práticas que promovam, auditem e garantam a prestação do controlo da qualidade radiológica e dosimétrica nos serviços de Radiologia a nível Nacional. Para tal, e no âmbito da publicação de estudos já realizados ao nível da União Europeia, ―Orientações Europeias dos Critérios de Qualidade para a Tomografia Computorizada (1999) ‖, é proposto estabelecer orientações na realização de estudos que permitam, numa primeira fase, estabelecer a comparação com os resultados obtidos pelos mecanismos de Controlo da Qualidade (CQ), analisar e proceder aos ajustes (se necessário) e, numa segunda fase, implementar uma moldura sistemática de avaliação periódica dos níveis de dose de radiação por exame TC e que permita a monitorização dos dados. Nesse sentido, propõe-se a realização de um Estudo Nacional que envolva a rede hospitalar pública, privada e universitária, partindo da metodologia utilizada em estudos prévios noutros países da Europa, como seja, selecção do equipamento de TC existente na Instituição Hospitalar, onde serão reunidas informações através do preenchimento de questionários relativos ao equipamento a utilizar. Serão recolhidos dados relativos ao utente, ao equipamento e parâmetros de aquisição de imagem, que permitam identificar os níveis de referência de diagnóstico (NRD) em TC, na realidade Portuguesa. Foi efectuado um estudo piloto numa instituição EPE e os valores obtidos não são significativos, nem podem assumir valor preditivo dado o reduzido tamanho da amostra. Apesar disso, sugerem a existência de parâmetros que podem ser alterados e com isso podem fazer variar a dose de radiação utilizada. ENSP/UNL Maria de Fátima Vaz de Carvalho 5 Espera-se obter com este estudo, como foi referido, a base do estabelecimento dos NRD em TC em Portugal. ----------------- ABSTRACT - The purpose of this study, in an empirical point of view, emerges from concern with the knowledge, attitudes, beliefs and practices regarding the use of ionizing radiation for diagnostic purposes and awareness of all actors involved, medical physical, technical, and responsible public health for the development of practices that promote, audited and ensure the provision of radiological quality control and dosing in radiology service at national level. In view of the complexity and characteristics involved in relation to ionizing radiation, all assume their part in protecting the physical integrity of each user and a global perspective, to ensure the safeguarding of public health, while global and globalizing factor. To this end, and in the context of the publication of studies already carried out at European Union level, "European guidelines for quality criteria for computed tomography", it is proposed to establish guidelines in conducting studies to initially establish the comparison with the results obtained by QC and make adjustments if necessary, and subsequently implement a systematic periodic assessment frame that allows monitoring of data. Accordingly, it is proposed to conduct a national study involving the public network, private and University hospitals, that extends from the methodology used in previous studies in other countries of Europe, as is, selection of equipment of existing CT in Hospital Institution, where information will be gathered by filling out questionnaires concerning the equipment to be used. Data will be collected for the wearer, equipment and parameters of image acquisition, identifying diagnostic reference levels (NRD) in CT in Portuguese fact. A pilot study was carried out in an institution EPE and the values obtained are not significant, nor can they take predictive value given the small sample size. Despite this, suggest the existence of parameters that can be changed and this can vary the dose of radiation used It is hoped to get with this study, as mentioned, the basis of the establishment of NRD in CT in Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Workshop on ns-3 (WNS '15). 13, May, 2015. Castelldefels, Spain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a hybrid coordinated manoeuvre for docking an autonomous surface vehicle with an autonomous underwater vehicle. The control manoeuvre uses visual information to estimate the AUV relative position and attitude in relation to the ASV and steers the ASV in order to dock with the AUV. The AUV is assumed to be at surface with only a small fraction of its volume visible. The system implemented in the autonomous surface vehicle ROAZ, developed by LSA-ISEP to perform missions in river environment, test autonomous AUV docking capabilities and multiple AUV/ASV coordinated missions is presented. Information from a low cost embedded robotics vision system (LSAVision), along with inertial navigation sensors is fused in an extended Kalman filter and used to determine AUV relative position and orientation to the surface vehicle The real time vision processing system is described and results are presented in operational scenario.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, three approaches for the assessment of credibility in a web environment will be presented, namely the checklists model, the cognitive authority model and the contextual model. This theoretical framework was used to conduct a study about the assessment of web resources credibility among a sample of 195 students, from elementary and secondary schools in a municipality in Oporto district (Portugal). The practices that young people and children claim to use regarding the use of criteria for web resources selection will be presented. In addition, these results will be discussed and compared with the perceptions that these respondents have demonstrated for the use of criteria to establish or assess authorship, originality, or information resources structure. These results will be also discussed and compared with the perceptions that these respondents have demonstrated for the elements that make up each of these criteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This communication aims to present some reflections regarding the importance of information in organizational context, especially in business context. The ability to produce and to share expertise and knowledge among its employees is now a key factor in the success of any organization. However, it’s also true that workers are increasingly feeling that too much information can hurt their performance. The existence of skilled professionals able to organize, evaluate, select and disseminate information in organizations appears to be a prerequisite for success. The skills necessary for the formation of a professional devoted to the management of information and knowledge in the context of business organizations will be analysed. Then data collected in two focus group discussion with students from a graduate course in Business Information, from Polytechnic Institute of Porto, Portugal, a will be examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proceedings of the 12th Conference on 'Dynamical Systems -Theory and Applications'

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An adaptive control damping the forced vibration of a car while passing along a bumpy road is investigated. It is based on a simple kinematic description of the desired behavior of the damped system. A modified PID controller containing an approximation of Caputo’s fractional derivative suppresses the high-frequency components related to the bumps and dips, while the low frequency part of passing hills/valleys are strictly traced. Neither a complete dynamic model of the car nor ’a priori’ information on the surface of the road is needed. The adaptive control realizes this kinematic design in spite of the existence of dynamically coupled, excitable internal degrees of freedom. The method is investigated via Scicos-based simulation in the case of a paradigm. It was found that both adaptivity and fractional order derivatives are essential parts of the control that can keep the vibration of the load at bay without directly controlling its motion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os modelos de maturidade são instrumentos facilitadores da gestão das organizações, incluindo a gestão da sua função sistemas de informação, não sendo exceção as organizações hospitalares. Neste artigo apresenta-se uma investigação inicial que visa o desenvolvimento de um abrangente modelo de maturidade para a gestão dos sistemas de informação hospitalares. O desenvolvimento deste modelo justifica-se porque os modelos de maturidade atuais no domínio da gestão dos sistemas informação hospitalares ainda se encontram numa fase embrionária de desenvolvimento, sobretudo porque são pouco detalhados, não disponibilizam ferramentas para determinação da maturidade e não apresentam as características dos estágios de maturidade estruturadas por diferentes fatores de influência.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to undertake a comparative analysis of the practices and information behaviour of European information users who visit information units specialising in European information in Portugal and Spain. The study used a quantitative methodology based on a questionnaire containing closed questions and one open question. The questions covered the general sociological profile of the respondents and their use of European Document Centres, in addition to analysing aspects associated with information behaviour relating to European themes. The study therefore examined data on the preferred means and sources for accessing European information, types of documents and the subjects investigated most. The use of European databases and the Internet to access material on Europe was also studied, together with the reasons which users considered made it easy or difficult to access European information, and the aspects they valued most in accessing this information. The questionnaire was administered in European Document Centres in 2008 and 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new environmentally friendly Au nanoparticles (Au NPs) synthesis in glycerol by using ultraviolet irradiation and without extra-added stabilizers is described. The synthesis proposed in this work may impact on the non-polluting production of noble nanoparticles with simple chemicals normally found in standard laboratories. These Au NPs were used to modify a carbon paste electrode (CPE) without having to separate them from the reaction medium. This green electrode was used as an electrochemical sensor for the nitrite detection in water. At the optimum conditions the green sensor presented a linear response in the 2.0×10−7–1.5×10−5 M concentration range, a good detection sensitivity (0.268 A L mol−1), and a low detection limit of 2.0×10−7 M of nitrite. The proposed modified green CPE was used to determine nitrite in tap water samples.