984 resultados para Female image


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes an evaluation framework that allows a standardized and quantitative comparison of IVUS lumen and media segmentation algorithms. This framework has been introduced at the MICCAI 2011 Computing and Visualization for (Intra)Vascular Imaging (CVII) workshop, comparing the results of eight teams that participated. We describe the available data-base comprising of multi-center, multi-vendor and multi-frequency IVUS datasets, their acquisition, the creation of the reference standard and the evaluation measures. The approaches address segmentation of the lumen, the media, or both borders; semi- or fully-automatic operation; and 2-D vs. 3-D methodology. Three performance measures for quantitative analysis have been proposed. The results of the evaluation indicate that segmentation of the vessel lumen and media is possible with an accuracy that is comparable to manual annotation when semi-automatic methods are used, as well as encouraging results can be obtained also in case of fully-automatic segmentation. The analysis performed in this paper also highlights the challenges in IVUS segmentation that remains to be solved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Work-life issues have become a major concern across Western societies with the objective to promote women's careers and well-being. However, despite growing attempts to increase the number of women in senior management positions in European countries, such as Switzerland, they remain highly underrepresented. Inspired from the cultural approach in psychology, this article focuses on these women's concrete everyday life to understand how they articulate different life domains and how this influences their subjective well-being. A narrative approach based on reflexivity is adopted to analyze women's activity. Results show meaning intertwinements between life priorities that are often conflicting. Two psychological functions are identified: the feeling of control and the letting go of control. Each of these contributes to women's subjective well-being through the use of diversified supports, but their structuring roles appear only in relation to one another. Results are discussed in the light of existing literature and of their implications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

TUTKIMUKSEN TAVOITTEET Tutkielman tavoitteena oli luoda ensin yleiskäsitys tuotemerkkimarkkinoinnin roolista teollisilla markkinoilla, sekä suhdemarkkinoinnin merkityksestä teollisessa merkkituotemarkkinoinnissa. Toisena oleellisena tavoitteena oli kuvata teoreettisesti merkkituoteidentiteetin rakenne teollisessa yrityksessä ja sen vaikutukset myyntihenkilöstöön, ja lisäksi haluttiin tutkia tuotemerkkien lisäarvoa sekä asiakkaalle että myyjälle. Identiteetti ja sen vaikutukset, erityisesti imago haluttiin tutkia myös empiirisesti. LÄHDEAINEISTO JA TUTKIMUSMENETELMÄT Tämän tutkielman teoreettinen osuus perustuu kirjallisuuteen, akateemisiin julkaisuihin ja aikaisempiin tutkimuksiin; keskittyen merkkituotteiden markkinointiin, identiteettiin ja imagoon, sekä suhdemarkkinointiin osana merkkituotemarkkinointia. Tutkimuksen lähestymistapa on kuvaileva eli deskriptiivinen ja sekä kvalitatiivinen että kvantitatiivinen. Tutkimus on tapaustutkimus, jossa caseyritykseksi valittiin kansainvälinen pakkauskartonki-teollisuuden yritys. Empiirisen osuuden toteuttamiseen käytettiin www-pohjaista surveytä, jonka avulla tietoja kerättiin myyntihenkilöstöltä case-yrityksessä. Lisäksi empiiristä osuutta laajennettiin tutkimalla sekundäärilähteitä kuten yrityksen sisäisiä kirjallisia dokumentteja ja tutkimuksia. TULOKSET. Teoreettisen ja empiirisen tutkimuksen tuloksena luotiin malli jota voidaan hyödyntää merkkituotemarkkinoinnin päätöksenteon tukena pakkauskartonki-teollisuudessa. Teollisen brandinhallinnan tulee keskittyä erityisesti asiakas-suhteiden brandaukseen – tätä voisi kutsua teolliseksi suhdebrandaukseksi. Tuote-elementit ja –arvot, differointi ja positiointi, sisäinen yrityskuva ja viestintä ovat teollisen brandi-identiteetin peruskiviä, jotka luovat brandi-imagon. Case-yrityksen myyntihenkilöstön tuote- ja yritysmielikuvat osoittautuivat kokonaisuudessaan hyviksi. Paras imago on CKB tuotteilla, kun taas heikoin on WLC tuotteilla. Teolliset brandit voivat luoda monenlaisia lisäarvoja sekä asiakas- että myyjäyritykselle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND AIMS: Formerly obese patients having undergone Roux-en-Y gastric bypass (RYGB) display both an accelerated digestion and absorption of carbohydrate and an increased plasma glucose clearance rate after meal ingestion. How RYGB effects postprandial kinetics of dietary lipids has yet not been investigated. METHODS: Plasma triglyceride (TG), apoB48, total apoB, bile acids (BA), fibroblast growth factor 19 (FGF19), and cholecystokinin (CCK) were measured in post-absorptive conditions and over 4-h following the ingestion of a mixed test meal in a cross-sectional, pilot study involving 11 formerly obese female patients 33.8 ± 16.4 months after RYGB surgery and in 11 weight- and age-matched female control participants. RESULTS: Compared to controls, RYGB patients had faster (254 ± 14 vs. 327 ± 7 min, p < 0.05) and lower (0.14 ± 0.04 vs. 0.35 ± 0.07 mM, p < 0.05) peak TG responses, but their peak apoB48 responses tended to be higher (2692 ± 336 vs. 1841 ± 228 ng/ml, p = 0.09). Their postprandial total BA concentrations were significantly increased and peaked earlier after meal ingestion than in controls. Their FGF19 and CCK concentrations also peaked earlier and to a higher value. CONCLUSIONS: The early postprandial apoB48 and BA responses indicate that RYGB accelerated the rate of dietary lipid absorption. The lower postprandial peak TG strongly suggests that the RYGB simultaneously increased the clearance of TG-rich lipoproteins. CLINICAL TRIAL REGISTRATION: NCT01891591.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser diffraction (LD) and static image analysis (SIA) of rectangular particles [United States Pharmacopeia, USP30-NF25, General Chapter <776>, Optical Miroscopy.] have been systematically studied. To rule out sample dispersion and particle orientation as the root cause of differences in size distribution profiles, we immobilize powder samples on a glass plate by means of a dry disperser. For a defined region of the glass plate, we measure the diffraction pattern as induced by the dispersed particles, and the 2D dimensions of the individual particles using LD and optical microscopy, respectively. We demonstrate a correlation between LD and SIA, with the scattering intensity of the individual particles as the dominant factor. In theory, the scattering intensity is related to the square of the projected area of both spherical and rectangular particles. In traditional LD the size distribution profile is dominated by the maximum projected area of the particles (A). The diffraction diameters of a rectangular particle with length L and breadth B as measured by the LD instrument approximately correspond to spheres of diameter ØL and ØB respectively. Differences in the scattering intensity between spherical and rectangular particles suggest that the contribution made to the overall LD volume probability distribution by each rectangular particle is proportional to A2/L and A2/B. Accordingly, for rectangular particles the scattering intensity weighted diffraction diameter (SIWDD) explains an overestimation of their shortest dimension and an underestimation of their longest dimension. This study analyzes various samples of particles whose length ranges from approximately 10 to 1000 μm. The correlation we demonstrate between LD and SIA can be used to improve validation of LD methods based on SIA data for a variety of pharmaceutical powders all with a different rectangular particle size and shape.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To improve coronary magnetic resonance angiography (MRA) by combining a two-dimensional (2D) spatially selective radiofrequency (RF) pulse with a T2 -preparation module ("2D-T2 -Prep"). METHODS: An adiabatic T2 -Prep was modified so that the first and last pulses were of differing spatial selectivity. The first RF pulse was replaced by a 2D pulse, such that a pencil-beam volume is excited. The last RF pulse remains nonselective, thus restoring the T2 -prepared pencil-beam, while tipping the (formerly longitudinal) magnetization outside of the pencil-beam into the transverse plane, where it is then spoiled. Thus, only a cylinder of T2 -prepared tissue remains for imaging. Numerical simulations were followed by phantom validation and in vivo coronary MRA, where the technique was quantitatively evaluated. Reduced field-of-view (rFoV) images were similarly studied. RESULTS: In vivo, full field-of-view 2D-T2 -Prep significantly improved vessel sharpness as compared to conventional T2 -Prep, without adversely affecting signal-to-noise (SNR) or contrast-to-noise ratios (CNR). It also reduced respiratory motion artifacts. In rFoV images, the SNR, CNR, and vessel sharpness decreased, although scan time reduction was 60%. CONCLUSION: When compared with conventional T2 -Prep, the 2D-T2 -Prep improves vessel sharpness and decreases respiratory ghosting while preserving both SNR and CNR. It may also acquire rFoV images for accelerated data acquisition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article provides expert opinion on the use of cardiovascular magnetic resonance (CMR) in young patients with congenital heart disease (CHD) and in specific clinical situations. As peculiar challenges apply to imaging children, paediatric aspects are repeatedly discussed. The first section of the paper addresses settings and techniques, including the basic sequences used in paediatric CMR, safety, and sedation. In the second section, the indication, application, and clinical relevance of CMR in the most frequent CHD are discussed in detail. In the current era of multimodality imaging, the strengths of CMR are compared with other imaging modalities. At the end of each chapter, a brief summary with expert consensus key points is provided. The recommendations provided are strongly clinically oriented. The paper addresses not only imagers performing CMR, but also clinical cardiologists who want to know which information can be obtained by CMR and how to integrate it in clinical decision-making.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: For free-breathing cardiovascular magnetic resonance (CMR), the self-navigation technique recently emerged, which is expected to deliver high-quality data with a high success rate. The purpose of this study was to test the hypothesis that self-navigated 3D-CMR enables the reliable assessment of cardiovascular anatomy in patients with congenital heart disease (CHD) and to define factors that affect image quality. METHODS: CHD patients ≥2 years-old and referred for CMR for initial assessment or for a follow-up study were included to undergo a free-breathing self-navigated 3D CMR at 1.5T. Performance criteria were: correct description of cardiac segmental anatomy, overall image quality, coronary artery visibility, and reproducibility of great vessels diameter measurements. Factors associated with insufficient image quality were identified using multivariate logistic regression. RESULTS: Self-navigated CMR was performed in 105 patients (55% male, 23 ± 12y). Correct segmental description was achieved in 93% and 96% for observer 1 and 2, respectively. Diagnostic quality was obtained in 90% of examinations, and it increased to 94% if contrast-enhanced. Left anterior descending, circumflex, and right coronary arteries were visualized in 93%, 87% and 98%, respectively. Younger age, higher heart rate, lower ejection fraction, and lack of contrast medium were independently associated with reduced image quality. However, a similar rate of diagnostic image quality was obtained in children and adults. CONCLUSION: In patients with CHD, self-navigated free-breathing CMR provides high-resolution 3D visualization of the heart and great vessels with excellent robustness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND AIMS: Smoking is a crucial environmental factor in inflammatory bowel disease (IBD). However, knowledge on patient characteristics associated with smoking, time trends of smoking rates, gender differences and supportive measures to cease smoking provided by physicians is scarce. We aimed to address these questions in Swiss IBD patients. METHODS: Prospectively obtained data from patients participating in the Swiss IBD cohort study was analysed and compared to the general Swiss population (GSP) matched by age, sex and year. RESULTS: Among a total of 1770 IBD patients analysed (49.1% male), 29% are current smokers. More than twice as many patients with Crohn's disease (CD) are active smokers compared to ulcerative colitis (UC, 39.6% vs. 15.3%, p<0.001). In striking contrast to the GSP, significantly more women than men with CD smoke (42.8% vs. 35.8%, p=0.025), with also an overall significantly increased smoking rate compared to the GSP in women but not men. The vast majority of smoking IBD patients (90.5%) claim to never have received any support to achieve smoking cessation, significantly more in UC compared to CD. We identify a significantly negative association of smoking and primary sclerosing cholangitis, indicative of a protective effect. Psychological distress in CD is significantly higher in smokers compared to non-smokers, but does not differ in UC CONCLUSIONS: Despite well-established detrimental effects, smoking rates in CD are alarmingly high with persistent and stagnating elevations compared to the GSP, especially in female patients. Importantly, there appears to be an unacceptable underuse of supportive measures to achieve smoking cessation.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le nombre d'examens tomodensitométriques (Computed Tomography, CT) effectués chaque année étant en constante augmentation, différentes techniques d'optimisation, dont les algorithmes de reconstruction itérative permettant de réduire le bruit tout en maintenant la résolution spatiale, ont étés développées afin de réduire les doses délivrées. Le but de cette étude était d'évaluer l'impact des algorithmes de reconstruction itérative sur la qualité image à des doses effectives inférieures à 0.3 mSv, comparables à celle d'une radiographie thoracique. Vingt CT thoraciques effectués à cette dose effective ont été reconstruits en variant trois paramètres: l'algorithme de reconstruction, rétroprojection filtrée versus reconstruction itérative iDose4; la matrice, 5122 versus 7682; et le filtre de résolution en densité (mou) versus spatiale (dur). Ainsi, 8 séries ont été reconstruites pour chacun des 20 CT thoraciques. La qualité d'image de ces 8 séries a d'abord été évaluée qualitativement par deux radiologues expérimentés en aveugle en se basant sur la netteté des parois bronchiques et de l'interface entre le parenchyme pulmonaire et les vaisseaux, puis quantitativement en utilisant une formule de merit, fréquemment utilisée dans le développement de nouveaux algorithmes et filtres de reconstruction. La performance diagnostique de la meilleure série acquise à une dose effective inférieure à 0.3 mSv a été comparée à celle d'un CT de référence effectué à doses standards en relevant les anomalies du parenchyme pulmonaire. Les résultats montrent que la meilleure qualité d'image, tant qualitativement que quantitativement a été obtenue en utilisant iDose4, la matrice 5122 et le filtre mou, avec une concordance parfaite entre les classements quantitatif et qualitatif des 8 séries. D'autre part, la détection des nodules pulmonaires de plus de 4mm étaient similaire sur la meilleure série acquise à une dose effective inférieure à 0.3 mSv et le CT de référence. En conclusion, les CT thoraciques effectués à une dose effective inférieure à 0.3 mSv reconstruits avec iDose4, la matrice 5122 et le filtre mou peuvent être utilisés avec confiance pour diagnostiquer les nodules pulmonaires de plus de 4mm.