915 resultados para Design Driven Innovation
Resumo:
In the race to obtain protons with higher energies, using more compact systems at the same time, laser-driven plasma accelerators are becoming an interesting possibility. But for now, only beams with extremely broad energy spectra and high divergence have been produced. The driving line of this PhD thesis was the study and design of a compact system to extract a high quality beam out of the initial bunch of protons produced by the interaction of a laser pulse with a thin solid target, using experimentally reliable technologies in order to be able to test such a system as soon as possible. In this thesis, different transport lines are analyzed. The first is based on a high field pulsed solenoid, some collimators and, for perfect filtering and post-acceleration, a high field high frequency compact linear accelerator, originally designed to accelerate a 30 MeV beam extracted from a cyclotron. The second one is based on a quadruplet of permanent magnetic quadrupoles: thanks to its greater simplicity and reliability, it has great interest for experiments, but the effectiveness is lower than the one based on the solenoid; in fact, the final beam intensity drops by an order of magnitude. An additional sensible decrease in intensity is verified in the third case, where the energy selection is achieved using a chicane, because of its very low efficiency for off-axis protons. The proposed schemes have all been analyzed with 3D simulations and all the significant results are presented. Future experimental work based on the outcome of this thesis can be planned and is being discussed now.
Resumo:
This thesis discusses the design of a system to use wave energy to pump oxygen-rich surface water towards the bottom of the sea. A simple device, called OXYFLUX, is proposed in a scale model and tested in a wave flume in order to validate its supposed theoretical functioning. Once its effectiveness has been demonstrated, a overset mesh, CFD model has been developed and validated by means of the physical model results. Both numerical and physical results show how wave height affects the behavior of the device. Wave heights lower than about 0.5 m overtop the floater and fall into it. As the wave height increases, phase shift between water surface and vertical displacement of the device also increases its influence on the functioning mechanism. In these situations, with wave heights between 0.5 and 0.9 m, the downward flux is due to the higher head established in the water column inside the device respect to the outside wave field. Furthermore, as the wave height grows over 0.9 m, water flux inverts the direction thanks to depression caused by the wave crest pass over the floater. In this situation the wave crest goes over the float but does not go into it and it draws water from the bottom to the surface through the device pipe. By virtue of these results a new shape of the floater has been designed and tested in CFD model. Such new geometry is based on the already known Lazzari’s profile and it aims to grab as much water as possible from the wave crest during the emergence of the floater from the wave field. Results coming from the new device are compared with the first ones in order to identify differences between the two shapes and their possible areas of application.
Resumo:
In the past two decades the work of a growing portion of researchers in robotics focused on a particular group of machines, belonging to the family of parallel manipulators: the cable robots. Although these robots share several theoretical elements with the better known parallel robots, they still present completely (or partly) unsolved issues. In particular, the study of their kinematic, already a difficult subject for conventional parallel manipulators, is further complicated by the non-linear nature of cables, which can exert only efforts of pure traction. The work presented in this thesis therefore focuses on the study of the kinematics of these robots and on the development of numerical techniques able to address some of the problems related to it. Most of the work is focused on the development of an interval-analysis based procedure for the solution of the direct geometric problem of a generic cable manipulator. This technique, as well as allowing for a rapid solution of the problem, also guarantees the results obtained against rounding and elimination errors and can take into account any uncertainties in the model of the problem. The developed code has been tested with the help of a small manipulator whose realization is described in this dissertation together with the auxiliary work done during its design and simulation phases.
Resumo:
Management Control System (MCS) research is undergoing turbulent times. For a long time related to cybernetic instruments of management accounting only, MCS are increasingly seen as complex systems comprising not only formal accounting-driven instruments, but also informal mechanisms of control based on organizational culture. But not only have the means of MCS changed; researchers increasingly ap-ply MCS to organizational goals other than strategy implementation.rnrnTaking the question of "How do I design a well-performing MCS?" as a starting point, this dissertation aims at providing a comprehensive and integrated overview of the "current-state" of MCS research. Opting for a definition of MCS, broad in terms of means (all formal as well as informal MCS instruments), but focused in terms of objectives (behavioral control only), the dissertation contributes to MCS theory by, a) developing an integrated (contingency) model of MCS, describing its contingencies, as well as its subcomponents, b) refining the equifinality model of Gresov/Drazin (1997), c) synthesizing research findings from contingency and configuration research concerning MCS, taking into account case studies on research topics such as ambi-dexterity, equifinality and time as a contingency.
Resumo:
With this dissertation research we investigate intersections between design and marketing and in this respect, which factors do contribute that a product design becomes brand formative. We have developed a Brand Formative Design (BFD) framework, which investigates individual design features in a holistic, comparable, brand relevant, and consumer specific context. We discuss what kinds of characteristics contribute to BFD but also illuminate how they should be applied and examine: rnA holistic framework leading to Brand Formative Design. Identification and assessment of BFD Drivers. The dissection of products into three Distinctive Design Levels. The detection of surprising design preferences. The appropriate degree of scheme deviation with evolutionary design. Simulated BFD development processes with three different products and the integration of consumers. Future oriented objectification, comparability and assessment of design. Recommendations for the management of design in a brand specific context. Design is a product feature, which contributes significantly to the success of products. However, the development of new design contains challenges. Design can hardly be objectified; many people have an opinion concerning the attractiveness of new products but cannot formulate their future preferences. Product design is widely developed based on intuition, which can be difficult for the management of design. Here the concept of Brand Formative Design can provide a framework which contributes to structure, objectify, develop and assess new evolutionary design in brand and future relevant contexts, but also integrates consumers and their preferences without restricting creativity too much.
Resumo:
Published evidence suggests that aspects of trial design lead to biased intervention effect estimates, but findings from different studies are inconsistent. This study combined data from 7 meta-epidemiologic studies and removed overlaps to derive a final data set of 234 unique meta-analyses containing 1973 trials. Outcome measures were classified as "mortality," "other objective," "or subjective," and Bayesian hierarchical models were used to estimate associations of trial characteristics with average bias and between-trial heterogeneity. Intervention effect estimates seemed to be exaggerated in trials with inadequate or unclear (vs. adequate) random-sequence generation (ratio of odds ratios, 0.89 [95% credible interval {CrI}, 0.82 to 0.96]) and with inadequate or unclear (vs. adequate) allocation concealment (ratio of odds ratios, 0.93 [CrI, 0.87 to 0.99]). Lack of or unclear double-blinding (vs. double-blinding) was associated with an average of 13% exaggeration of intervention effects (ratio of odds ratios, 0.87 [CrI, 0.79 to 0.96]), and between-trial heterogeneity was increased for such studies (SD increase in heterogeneity, 0.14 [CrI, 0.02 to 0.30]). For each characteristic, average bias and increases in between-trial heterogeneity were driven primarily by trials with subjective outcomes, with little evidence of bias in trials with objective and mortality outcomes. This study is limited by incomplete trial reporting, and findings may be confounded by other study design characteristics. Bias associated with study design characteristics may lead to exaggeration of intervention effect estimates and increases in between-trial heterogeneity in trials reporting subjectively assessed outcomes.
Resumo:
A prototype vortex-driven air lift pump was developed and experimentally evaluated. It was designed to be easily manufactured and scalable for arbitrary riser diameters. The model tested fit in a 2 inch diameter riser with six air injection nozzles through which airwas injected helically around the perimeter of the riser at an angle of 70º from pure tangential injection. The pump was intended to transport both water and sediment over a large range of submergence ratios. A test apparatus was designed to be able to simulate deep water or oceanic environments. The resulting test setup had a finite reservoir; over the course of a test, the submergence ratio varied from 0.48 to 0.39. For air injection pressures ranging from 10 to 60 psig and for air flow rates of 6 to 15 scfm, the induced water discharge flow rates varied only slightly, due to the limited range of available submergence ratios. The anticipated simulation of deep water environment, with a corresponding equivalent increase in thesubmergence ratio, proved unattainable. The pump prototype successfully transported both water and sediment (sand). Thepercent volume yield of the sediment was in an acceptable range. The pump design has been subsequently used successfully in a 4 inch configuration in a follow-on project. A computer program was written in Matlab to simulate the pump characteristics. The program output water pressures at the location of air injection which were physicallycompatible with the experimental data.
Resumo:
A significant cost for foundations is the design and installation of piles when they are required due to poor ground conditions. Not only is it important that piles be designed properly, but also that the installation equipment and total cost be evaluated. To assist in the evaluation of piles a number of methods have been developed. In this research three of these methods were investigated, which were developed by the Federal Highway Administration, the US Corps of Engineers and the American Petroleum Institute (API). The results from these methods were entered into the program GRLWEAPTM to assess the pile drivability and to provide a standard base for comparing the three methods. An additional element of this research was to develop EXCEL spreadsheets to implement these three methods. Currently the Army Corps and API methods do not have publicly available software and must be performed manually, which requires that data is taken off of figures and tables, which can introduce error in the prediction of pile capacities. Following development of the EXCEL spreadsheet, they were validated with both manual calculations and existing data sets to ensure that the data output is correct. To evaluate the three pile capacity methods data was utilized from four project sites from North America. The data included site geotechnical data along with field determined pile capacities. In order to achieve a standard comparison of the data, the pile capacities and geotechnical data from the three methods were entered into GRLWEAPTM. The sites consisted of both cohesive and cohesionless soils; where one site was primarily cohesive, one was primarily cohesionless, and the other two consisted of inter-bedded cohesive and cohesionless soils. Based on this limited set of data the results indicated that the US Corps of Engineers method more closely compared with the field test data, followed by the API method to a lesser degree. The DRIVEN program compared favorably in cohesive soils, but over predicted in cohesionless material.
Resumo:
During locomotion, turning is a common and recurring event which is largely neglected in the current state-of-the-art ankle-foot prostheses, forcing amputees to use different steering mechanisms for turning, compared to non-amputees. A better understanding of the complexities surrounding lower limb prostheses will lead to increased health and well-being of amputees. The aim of this research is to develop a steerable ankle-foot prosthesis that mimics the human ankle mechanical properties. Experiments were developed to estimate the mechanical impedance of the ankle and the ankles angles during straight walk and step turn. Next, this information was used in the design of a prototype, powered steerable ankle-foot prosthesis with two controllable degrees of freedom. One of the possible approaches in design of the prosthetic robots is to use the human joints’ parameters, especially their impedance. A series of experiments were conducted to estimate the stochastic mechanical impedance of the human ankle when muscles were fully relaxed and co-contracting antagonistically. A rehabilitation robot for the ankle, Anklebot, was employed to provide torque perturbations to the ankle. The experiments were performed in two different configurations, one with relaxed muscles, and one with 10% of maximum voluntary contraction (MVC). Surface electromyography (sEMG) was used to monitor muscle activation levels and these sEMG signals were displayed to subjects who attempted to maintain them constant. Time histories of ankle torques and angles in the lateral/medial (LM) directions, inversion-eversion (IE), and dorsiflexionplantarflexion (DP) were recorded. Linear time-invariant transfer functions between the measured torques and angles were estimated providing an estimate of ankle mechanical impedance. High coherence was observed over a frequency range up to 30 Hz. The main effect of muscle activation was to increase the magnitude of ankle mechanical impedance in all degrees of freedom of the ankle. Another experiment compared the three-dimensional angles of the ankle during step turn and straight walking. These angles were measured to be used for developing the control strategy of the ankle-foot prosthesis. An infrared camera system was used to track the trajectories and angles of the foot and leg. The combined phases of heel strike and loading response, mid stance, and terminal stance and pre-swing were determined and used to measure the average angles at each combined phase. The Range of motion (ROM) in IE increased during turning while ML rotation decreased and DP changed the least. During the turning step, ankle displacement in DP started with similar angles to straight walk and progressively showed less plantarflexion. In IE, the ankle showed increased inversion leaning the body toward the inside of the turn. ML rotation initiated with an increased medial rotation during the step turn relative to the straight walk transitioning to increased lateral rotation at the toe off. A prototype ankle-foot prosthesis capable of controlling both DP and IE using a cable driven mechanism was developed and assessed as part of a feasibility study. The design is capable of reproducing the angles required for straight walk and step turn; generates 712N of lifting force in plantarflexion, and shows passive stiffness comparable to a nonload bearing ankle impedance. To evaluate the performance of the ankle-foot prosthesis, a circular treadmill was developed to mimic human gait during steering. Preliminary results show that the device can appropriately simulate human gait with loading and unloading the ankle joint during the gait in circular paths.
Resumo:
In the realm of computer programming, the experience of writing a program is used to reinforce concepts and evaluate ability. This research uses three case studies to evaluate the introduction of testing through Kolb's Experiential Learning Model (ELM). We then analyze the impact of those testing experiences to determine methods for improving future courses. The first testing experience that students encounter are unit test reports in their early courses. This course demonstrates that automating and improving feedback can provide more ELM iterations. The JUnit Generation (JUG) tool also provided a positive experience for the instructor by reducing the overall workload. Later, undergraduate and graduate students have the opportunity to work together in a multi-role Human-Computer Interaction (HCI) course. The interactions use usability analysis techniques with graduate students as usability experts and undergraduate students as design engineers. Students get experience testing the user experience of their product prototypes using methods varying from heuristic analysis to user testing. From this course, we learned the importance of the instructors role in the ELM. As more roles were added to the HCI course, a desire arose to provide more complete, quality assured software. This inspired the addition of unit testing experiences to the course. However, we learned that significant preparations must be made to apply the ELM when students are resistant. The research presented through these courses was driven by the recognition of a need for testing in a Computer Science curriculum. Our understanding of the ELM suggests the need for student experience when being introduced to testing concepts. We learned that experiential learning, when appropriately implemented, can provide benefits to the Computer Science classroom. When examined together, these course-based research projects provided insight into building strong testing practices into a curriculum.
Resumo:
Surgery and other invasive therapies are complex interventions, the assessment of which is challenged by factors that depend on operator, team, and setting, such as learning curves, quality variations, and perception of equipoise. We propose recommendations for the assessment of surgery based on a five-stage description of the surgical development process. We also encourage the widespread use of prospective databases and registries. Reports of new techniques should be registered as a professional duty, anonymously if necessary when outcomes are adverse. Case series studies should be replaced by prospective development studies for early technical modifications and by prospective research databases for later pre-trial evaluation. Protocols for these studies should be registered publicly. Statistical process control techniques can be useful in both early and late assessment. Randomised trials should be used whenever possible to investigate efficacy, but adequate pre-trial data are essential to allow power calculations, clarify the definition and indications of the intervention, and develop quality measures. Difficulties in doing randomised clinical trials should be addressed by measures to evaluate learning curves and alleviate equipoise problems. Alternative prospective designs, such as interrupted time series studies, should be used when randomised trials are not feasible. Established procedures should be monitored with prospective databases to analyse outcome variations and to identify late and rare events. Achievement of improved design, conduct, and reporting of surgical research will need concerted action by editors, funders of health care and research, regulatory bodies, and professional societies.
Resumo:
Research on surgical interventions is associated with several methodological and practical challenges of which few, if any, apply only to surgery. However, surgical evaluation is especially demanding because many of these challenges coincide. In this report, the second of three on surgical innovation and evaluation, we discuss obstacles related to the study design of randomised controlled trials and non-randomised studies assessing surgical interventions. We also describe the issues related to the nature of surgical procedures-for example, their complexity, surgeon-related factors, and the range of outcomes. Although difficult, surgical evaluation is achievable and necessary. Solutions tailored to surgical research and a framework for generating evidence on which to base surgical practice are essential.
Resumo:
BACKGROUND: Ischemic stroke is the leading cause of mortality worldwide and a major contributor to neurological disability and dementia. Terutroban is a specific TP receptor antagonist with antithrombotic, antivasoconstrictive, and antiatherosclerotic properties, which may be of interest for the secondary prevention of ischemic stroke. This article describes the rationale and design of the Prevention of cerebrovascular and cardiovascular Events of ischemic origin with teRutroban in patients with a history oF ischemic strOke or tRansient ischeMic Attack (PERFORM) Study, which aims to demonstrate the superiority of the efficacy of terutroban versus aspirin in secondary prevention of cerebrovascular and cardiovascular events. METHODS AND RESULTS: The PERFORM Study is a multicenter, randomized, double-blind, parallel-group study being carried out in 802 centers in 46 countries. The study population includes patients aged > or =55 years, having suffered an ischemic stroke (< or =3 months) or a transient ischemic attack (< or =8 days). Participants are randomly allocated to terutroban (30 mg/day) or aspirin (100 mg/day). The primary efficacy endpoint is a composite of ischemic stroke (fatal or nonfatal), myocardial infarction (fatal or nonfatal), or other vascular death (excluding hemorrhagic death of any origin). Safety is being evaluated by assessing hemorrhagic events. Follow-up is expected to last for 2-4 years. Assuming a relative risk reduction of 13%, the expected number of primary events is 2,340. To obtain statistical power of 90%, this requires inclusion of at least 18,000 patients in this event-driven trial. The first patient was randomized in February 2006. CONCLUSIONS: The PERFORM Study will explore the benefits and safety of terutroban in secondary cardiovascular prevention after a cerebral ischemic event.
Resumo:
Im Bereich Medical Design spielen eine hohe Funktionalität und eine angenehme Handhabung eine grosse Rolle. In den Engineering-Projekten der Erdmann Design AG werden kühne Ideen in den Raum gesetzt die das Klima für Innovationen fördern. „Innovation entsteht aus elementarer Neugier und Lust auf eine bessere Zukunft“, sagt Raimund Erdmann. „Wir beraten mit unseren Feed Forward Methoden Start-up Firmen, Kleinunternehmen wie auch etliche, börsenkotierte, international aktive Unternehmen. Und das für excellentes Industrial Design, Corporate Design und Design Management“ mit den überzeugenden Möglichkeiten des Rapid Manufacturing.Im Bereich Medical Design spielen eine hohe Funktionalität und eine angenehme Handhabung eine grosse Rolle. In den Engineering-Projekten der Erdmann Design AG werden kühne Ideen in den Raum gesetzt die das Klima für Innovationen fördern. „Innovation entsteht aus elementarer Neugier und Lust auf eine bessere Zukunft“, sagt Raimund Erdmann. „Wir beraten mit unseren Feed Forward Methoden Start-up Firmen, Kleinunternehmen wie auch etliche, börsenkotierte, international aktive Unternehmen. Und das für excellentes Industrial Design, Corporate Design und Design Management“ mit den überzeugenden Möglichkeiten des Rapid Manufacturing.
Resumo:
Many aspects in the area of designing platforms for intra-organizational innovation communities are not well understood. In this article, we examine the impact of technologically induced psychological factors on knowledge exchange in such communities. Using two experimental pretest-posttest experiments, we find that the implementation of (i) technologically induced self-efficacy (expressed by a ‘hurray’ message) and (ii) technologically induced positive affect (expressed by playing some 30 seconds of rock-‘n’-roll music) in the design of the platform results in an influential increase of knowledge exchange. Importantly, the studies suggest that the integration of technologically induced self-efficacy leads to a higher extent of knowledge exchange than technologically induced positive affect. The implications of these results for future research and practice as well as for the design of a platform for such communities are discussed.