952 resultados para Color ultrasonography Doppler


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No safe ultrasound (US) parameters have been established to differentiate the causes of graft dysfunction.To define US parameters and identify the predictors of normal graft evolution, delayed graft function (DGF), and rejection at the early period after kidney transplantation.Between June 2012 and August 2013, 79 renal transplant recipients underwent US examination 1-3 days posttransplantation. Resistive index (RI), power Doppler (PD), and RI + PD (quantified PD) were assessed. Patients were allocated into three groups: normal graft evolution, DGF, and rejection.Resistive index of upper and middle segments and PD were higher in the DGF group than in the normal group. ROC curve analysis revealed that RI + PD was the index that best correlated with DGF (cutoff = 0.84). In the high RI + PD group, time to renal function recovery (6.33 +/- A 6.5 days) and number of dialysis sessions (2.81 +/- A 2.8) were greater than in the low RI + PD group (2.11 +/- A 5.3 days and 0.69 +/- A 1.5 sessions, respectively), p = 0.0001. Multivariate analysis showed that high donor final creatinine with a relative risk (RR) of 19.7 (2.01-184.7, p = 0.009) and older donor age (RR = 1.17 (1.04-1.32), p = 0.007) correlated with risk DGF.Quantified PD (RI + PD) was the best DGF predictor. PD quantification has not been previously reported .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the cumulative effects of brushing (B) or immersion (I), using different cleansing agents, on the surface roughness, hardness and color stability of a heat-polymerized denture resin, Lucitone 550 (L), and a hard chairside reline resin, Tokuyama Rebase Fast II (T). Methods: A total of 316 specimens (10 x 2 mm) were fabricated. The specimens (n= 9) were divided into brushing or immersion groups according to the following agents: dentifrice/distilled water (D), 1% sodium hypochlorite (Na0C1), Corega Tabs (Pb), 1% chlorhexidine gluconate (Chx), and 0.2% peracetic acid (Ac). Brushing and immersion were tested independently. Assays were performed after 1, 3, 21, 45 and 90 blushing cycles or immersion of 10 seconds each. Data were evaluated statistically by repeated measures ANOVA. Tukey's honestly significant difference (HSD) post-hoc test was used to determine differences between means (a= 0.05). Results: For L there was no statistically significant difference in roughness, except a significant decrease in roughness by brushing with D. T showed a significant effect on the roughness after 90 immersions with Ac. Hardness values decreased for L when specimens were immersed or brushed in Na0C1 and Pb. The hardness of T decreased with increases in the repetitions (immersion or brushing), regardless of the cleaning method. Values of color stability for L resin showed significant color change after brushing with and immersion in Ac and Pb. Brushing with D exhibited a higher incidence of color change. For T there were no significant differences between cleaning agents and repetitions in immersion. A color change was noted after three brushings with the Ac, Chx, and D. Brushing with dentifrice decreased roughness of L. Immersion in or brushing with Na0C1 and Pb decreased the hardness of L. For T, hardness decreased with increases in immersions or brushing. Color changes after the immersion in or brushing with cleaning agents were clinically acceptable according to National Bureau of Standards parameters for both resins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Developmental defects involving color alteration of enamel frequently compromise the esthetic appearance of the tooth. The resin infiltration technique represents an alternative treatment for color masking of these lesions and uniformization of tooth color. This technique is considered relatively simple and microinvasive, since only a minimal portion of enamel is removed. This article illustrates the color-masking effect with resin infiltration of fluorosis and traumatic hypomineralization lesions with a case series. The final esthetic outcomes demonstrated the ability of the resin infiltrant to mask the color of white developmental defect lesions, resulting in satisfactory clinical esthetic improvements. However, in more severe cases, the color-masking effect was not complete.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aim of this study was to investigate the effect of hydrogen peroxide gels with different concentrations (20%, 25%, 30%, and 35%) on enamel Knoop microhardness (KNIT) as well as on changes in dental color (C).Methods: Cylindrical specimens of enamel/dentin (3-nun diameter and 2-nun thickness) were obtained from bovine incisors and randomly divided into six groups (n=20), according to the concentration of the whitening gel (20%, 25%, 30%, 35%, control, thickener). After polishing, initial values of KNH0 and color measurement, assessed by spectrophotometry using the CIE L*a*b* system, were taken from the enamel surface. The gels were applied on the enamel surface for 30 minutes, and immediate values of KNHi were taken. After seven days of being stored in artificial saliva, new measures of KNH7 and color (L-7* a(7)* b(7)*, for calculating Delta E, Delta L, and Delta b) were made. Data were submitted to statistical analysis of variance, followed by Tukey test (p<0.05).Results: Differences in gel concentration and time did not influence the microhardness (p=0.54 and p=0.29, respectively). In relation to color changes, Delta E data showed that the 35% gel presented a higher color alteration than the 20% gel did (p=0.006).Conclusion: Bleaching with 35% hydrogen peroxide gel was more effective than with the 20% gel, without promoting significant adverse effects on enamel surface microhardness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The preparation of Tm3+/Yb3+/Ho3+ co-doped CeO2 prepared by the precipitation method using ammonium hydroxide as a precursor is presented. By X-ray diffraction the materials show the phase-type of fluorite structure and the crystallite sizes were calculated by the Scherrer's equation. No other phase was observed evincing that the rare earth ions were inserted into the fluorite phase as substitutional or interstitial dopants. The microstrain calculated by the Williamson-Hall method do not show significant changes in their values, indicating that the inclusion of rare earths does not causes structural changes in the CeO2 used as a host matrix. All material showed intense upconversion emission at red and green region under excitation with diode laser at 980 nm. The color of emission changes from green to red with increasing excitation power pump. The materials showed suitable photoluminescent properties for applications as a laser source, solar cells, and great emitter at 800 nm. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obesity is the most common nutritional problem in dogs and it can cause various harmful effects on animal health. However, the effect of this condition on systolic blood pressure (SBP) in obese dogs is controversial. The indirect method of measuring PAS is the most commonly used in veterinary medicine for the diagnosis of systemic hypertension, because it is more practical and easy to access. There is little scientific information about the comparison of the two non- invasive methods of measurement of blood pressure in obese dogs. Therefore, the objective of this study was to evaluate the SBP in obese dogs by comparing both indirect methods of measuring blood pressure, with oscillometric and doppler vascular in order to verify the differences in blood pressure values, but also the best method to assess the SBP dogs in this body score condition. The study complain blood pressure measurement of 50 dogs, with were divided in obese dogs with mean body condition score (BCS) of 8.42 +/- 0.50 (n = 25) and dogs with ideal BCS of 4.56 +/- 0.51 (n = 25). At comparison of blood pressure values, SBP values obtained by doppler method (152 +/- 16mmHg) were higher than the oscillometric (136 +/- 11mmHg). Correspondence analysis determined by multivariate statistical analysis showed correlation between body condition and the procedure of the SBP. These findings suggest that the indirect method doppler can better reflect the SBP in obese dogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study developed a Color Scale of Perceived Exertion (RPE-color scale) and assessed its concurrent and construct validity in adult women. One hundred participants (18-77 years), who were habitual exercisers, associated colors with verbal anchors of the Borg RPE scale (RPE-Borg scale) for RPE-color scale development. For RPE-color scale validation, 12 Young (M = 21.7 yr., SD = 1.5) and 10 Older (M = 60.3 yr., SD = 3.5) adult women performed a maximal graded exercise test on a treadmill and reported perceived exertion in both RPE-color and RPE-Borg scales. In the Young group, the RPE-color scale was significantly associated with heart rate and oxygen consumption, having strong correlations with the RPE-Borg scale. In the Older group, the RPE-color scale was significantly associated with heart rate, having moderate to high correlations with the RPE-Borg scale. The RPE-color scale demonstrated concurrent and construct validity in the Young women, as well as construct validity in Older adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)