998 resultados para Bearing test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conocer cuál es la personalidad de aquellos que acceden a nuestras Escuelas y que en pocos años se convertirán en futuros profesionales de Enfermería, ha sido el objetivo de un estudio llevado a cabo por la Comisión de Docencia de la E.U.E. de Barcelona. En él se realiza un análisis comparativo de los perfiles de personalidad de los estudiantes admitidos en la E.U.E. de Barcelona y los candidatos pre-inscritos en dicha escuela en 1983, frente a estudiantes de Enfermería americanas y británicas y los candidatos a estudiantes de Medicina de la Universidad de Navarra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the primary goals for food packages is to protect food against harmful environment, especially oxygen and moisture. The gas transmission rate is the total gas transport through the package, both by permeation through the package material and by leakage through pinholes and cracks. The shelf life of a product can be extended, if the food is stored in a gas tight package. Thus there is a need to test gas tightness of packages. There are several tightness testing methods, and they can be broadly divided into destructive and nondestructive methods. One of the most sensitive methods to detect leaks is by using a non destructive tracer gas technique. Carbon dioxide, helium and hydrogen are the most commonly used tracer gases. Hydrogen is the lightest and the smallest of all gases, which allows it to escape rapidly from the leak areas. The low background concentration of H2 in air (0.5 ppm) enables sensitive leak detection. With a hydrogen leak detector it is also possible to locate leaks. That is not possible with many other tightness testing methods. The experimental work has been focused on investigating the factors which affect the measurement results with the H2leak detector. Also reasons for false results were searched to avoid them in upcoming measurements. From the results of these experiments, the appropriate measurement practice was created in order to have correct and repeatable results. The most important thing for good measurement results is to keep the probe of the detector tightly against the leak. Because of its high diffusion rate, the HZ concentration decreases quickly if holding the probe further away from the leak area and thus the measured H2 leaks would be incorrect and small leaks could be undetected. In the experimental part hydrogen, oxygen and water vapour transmissions through laser beam reference holes (diameters 1 100 μm) were also measured and compared. With the H2 leak detector it was possible to detect even a leakage through 1 μm (diameter) within a few seconds. Water vapour did not penetrate even the largest reference hole (100 μm), even at tropical conditions (38 °C, 90 % RH), whereas some O2 transmission occurred through the reference holes larger than 5 μm. Thus water vapour transmission does not have a significant effect on food deterioration, if the diameter of the leak is less than 100 μm, but small leaks (5 100 μm) are more harmful for the food products, which are sensitive to oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fiscal policy rule implicit in the Stability and Growth Pact, has been rationalised as a way to ensure that national fiscal policies remain sustainable within the EU, thereby endorsing the independence of the ECB. We empirically examine the sustainability of European fiscal policies over the period 1970-2001. The intertemporal government budget constraint provides a test based on the cointegration relation between government revenues, expenditures and interest payments. Sustainability is analysed at both the national level and for a European panel. Results show that European fiscal policy has been sustainable overall, yet national experiences differ considerably.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The void structure of zeolites MCM-22, MCM-36 and ITQ-2 were discussed on the bases of catalytic reaction tests. The hydromerization of n-decane on bifunctional Pt/Zeolite Catalysts have been used as model reactions. Beta and ZSM-5 zeolites were used for comparison. It is concluded that all materials show features of 10MR zeolites and have also pores bigger than 12MR in this order MCM-22

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of load-bearing osseous implant with desired mechanical and surface properties in order to promote incorporation with bone and to eliminate risk of bone resorption and implant failure is a very challenging task. Bone formation and resoption processes depend on the mechanical environment. Certain stress/strain conditions are required to promote new bone growth and to prevent bone mass loss. Conventional metallic implants with high stiffness carry most of the load and the surrounding bone becomes virtually unloaded and inactive. Fibre-reinforced composites offer an interesting alternative to metallic implants, because their mechanical properties can be tailored to be equal to those of bone, by the careful selection of matrix polymer, type of fibres, fibre volume fraction, orientation and length. Successful load transfer at bone-implant interface requires proper fixation between the bone and implant. One promising method to promote fixation is to prepare implants with porous surface. Bone ingrowth into porous surface structure stabilises the system and improves clinical success of the implant. The experimental part of this work was focused on polymethyl methacrylate (PMMA) -based composites with dense load-bearing core and porous surface. Three-dimensionally randomly orientated chopped glass fibres were used to reinforce the composite. A method to fabricate those composites was developed by a solvent treatment technique and some characterisations concerning the functionality of the surface structure were made in vitro and in vivo. Scanning electron microscope observations revealed that the pore size and interconnective porous architecture of the surface layer of the fibre-reinforced composite (FRC) could be optimal for bone ingrowth. Microhardness measurements showed that the solvent treatment did not have an effect on the mechanical properties of the load-bearing core. A push-out test, using dental stone as a bone model material, revealed that short glass fibre-reinforced porous surface layer is strong enough to carry load. Unreacted monomers can cause the chemical necrosis of the tissue, but the levels of leachable resisidual monomers were considerably lower than those found in chemically cured fibre-reinforced dentures and in modified acrylic bone cements. Animal experiments proved that surface porous FRC implant can enhance fixation between bone and FRC. New bone ingrowth into the pores was detected and strong interlocking between bone and the implant was achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to develop and validate a dissolution test for glibenclamide tablets. Optimal conditions to carry out the dissolution test are 500 mL of phosphate buffer at pH 8.0, paddles at 75 rpm stirring speed, time test set to 60 min and using equipment with six vessels. The derivative UV spectrophotometric method for determination of glibenclamide released was developed, validated and compared with the HPLC method. The UVDS method presents linearity (r² = 0.9999) in the concentration range of 5-14 µg/mL. Precision and recoveries were 0.42% and 100.25%, respectively. The method was applied to three products commercially available on the Brazilian market.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we describe both a chromatographic purification procedure and a spot test for the enzyme peroxidase (POD: EC 1.11.1.7). The enzyme was obtained from crude extracts of sweet potatoes and the chromatographic enzyme purification procedure resulted in several fractions. Therefore a simple, fast and economic spot test for monitoring peroxidase during the purification procedure was developed. The spot test is based on the reaction of hydrogen peroxide and guaiacol, which is catalyzed by the presence of peroxidase yielding the colored tetraguaiacol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundamento: El objetivo del estudio fue evaluar el cambio de estrategia de cribado (test inmunológico cuantitativo) en un programa poblacional de detección precoz de cáncer colorrectal (CCR) en Cataluña. Métodos: La cuarta ronda del programa de cribado de CCR en Hospitalet de Llobregat se implementó en 2008-2010. Se ofreció un test bioquímico a 50.227 individuos y uno inmunológico cuantitativo a 12.707 individuos. Se analizaron diferencias en las dos estrategias de cribado respecto a variables de aceptabilidad (entre participación, abandonos y adherencia a la colonoscopia), de precisión diagnóstica (valor predictivo positivo y tasas de detección), de resultados (tamaño y localización de lesiones, estadio de los cánceres detectados) y de recursos (número necesario de colonoscopias e intervalo de tiempo entre el resultado positivo del test y la colonoscopia). Resultados: La participación en el cribado fue superior entre los individuos que utilizaron el test inmunológico (OR: 1,35; IC95%:1,27-1,42). Las tasas de detección fueron superiores para el test inmunológico destacando la de adenomas de alto riesgo (26,7 vs 3,0 ). El valor predictivo positivo para adenomas de alto riesgo fue del 45,0% y del 46,9% en el inmunológico y el guayaco, respectivamente. El número de colonoscopias necesarias para detectar un cáncer fue de casi el doble que en el guayaco (13,6 vs 7,4). Conclusiones: El test inmunológico es una buena estrategia de cribado especialmente sensible para la detección de adenomas de alto riesgo. Sin embargo, requiere realizar un gran número de colonoscopias y por ello se debe disponer de los recursos y medios necesarios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dissolution test for telithromycin tablets was validated and developed. In order to choose the most discriminatory one, the conditions to carry out are 900 mL of sodium phosphate buffer at pH 7.5, paddles at 50 rpm stirring speed, time test set to 60 min and using USP apparatus 2 with paddles. The UV spectrophotometric method for determination of telithromycin released was developed and validated. The method presents linearity (r = 1) in the concentration range of 20-60 µg/mL. Precision and recoveries were good, 100.62 and 97.06%, respectively. The method was successfully used for the dissolution test of telithromycin tablets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 50 mg losartan potassium capsules using HPLC and UV spectrophotometry. A 2(4) full factorial design was carried out to optimize dissolution conditions and potassium phosphate buffer, pH 6.8 as dissolution medium, basket as apparatus at the stirring speed of 50 rpm and time of 30 min were considered adequate. Both dissolution procedure and analytical methods were validated and a statistical analysis showed that there are no significant differences between HPLC and spectrophotometry. Since there is no official monograph, this dissolution test could be applied for quality control routine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aimed the development and validation of a new dissolution test for ornidazole coated tablets. The dissolution conditions were determined after testing Sink conditions, dissolution medium, apparatus, stirring speed, 24 h stability and medium filtration influence. The best conditions were paddle at a stirring speed of 75 rpm and 900 mL of 0.1 M HCl. A new HPLC quantification method was developed and validated. The dissolution test and quantification method showed to be adequate for their purposes and could be applied for quality control of ornidazole coated tablets, since there is no official monograph.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dissolution test for in vitro evaluation of tablet dosage forms containing 10 mg of rupatadine was developed and validated by RP-LC. A discriminatory dissolution method was established using apparatus paddle at a stirring rate of 50 rpm with 900 mL of deaerated 0.01 M hydrochloric acid. The proposed method was validated yielding acceptable results for the parameters evaluated, and was applied for the quality control analysis of rupatadine tablets, and to evaluate the formulation during an accelerated stability study. Moreover, quantitative analyses were also performed, to compare the applicability of the RP-LC and the LC-MS/MS methods.