932 resultados para 321022 Radiology and Organ Imaging


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND & AIMS Patients with cirrhosis hospitalized for an acute decompensation (AD) and organ failure are at risk for imminent death and considered to have acute-on-chronic liver failure (ACLF). However, there are no established diagnostic criteria for ACLF, so little is known about its development and progression. We aimed to identify diagnostic criteria of ACLF and describe the development of this syndrome in European patients with AD. METHODS We collected data from 1343 hospitalized patients with cirrhosis and AD from February to September 2011 at 29 liver units in 8 European countries. We used the organ failure and mortality data to define ACLF grades, assess mortality, and identify differences between ACLF and AD. We established diagnostic criteria for ACLF based on analyses of patients with organ failure (defined by the chronic liver failure-sequential organ failure assessment [CLIF-SOFA] score) and high 28-day mortality rate (>15%). RESULTS Of the patients assessed, 303 had ACLF when the study began, 112 developed ACLF, and 928 did not have ACLF. The 28-day mortality rate among patients who had ACLF when the study began was 33.9%, among those who developed ACLF was 29.7%, and among those who did not have ACLF was 1.9%. Patients with ACLF were younger and more frequently alcoholic, had more associated bacterial infections, and had higher numbers of leukocytes and higher plasma levels of C-reactive protein than patients without ACLF (P < .001). Higher CLIF-SOFA scores and leukocyte counts were independent predictors of mortality in patients with ACLF. In patients without a prior history of AD, ACLF was unexpectedly characterized by higher numbers of organ failures, leukocyte count, and mortality compared with ACLF in patients with a prior history of AD. CONCLUSIONS We analyzed data from patients with cirrhosis and AD to establish diagnostic criteria for ACLF and showed that it is distinct from AD, based not only on the presence of organ failure(s) and high mortality rate but also on age, precipitating events, and systemic inflammation. ACLF mortality is associated with loss of organ function and high leukocyte counts. ACLF is especially severe in patients with no prior history of AD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tenascins are extracellular matrix proteins with distinct spatial and temporal expression during development, tissue homeostasis and disease. Based on their expression patterns and knockout phenotypes an important role of tenascins in tissue formation, cell adhesion modulation, regulation of proliferation and differentiation has been demonstrated. All of these features are of importance in stem cell niches where a precise regulation of growth versus differentiation has to be guaranteed. In this review we summarize the expression and possible functions of tenascins in neural, epithelial and osteogenic stem cell niches during normal development and organ turnover, in the hematopoietic and pro-inflammatory niche as well as in the metastatic niche during cancer progression.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ex vivo porcine retina laser lesions applied with varying laser power (20 mW–2 W, 10 ms pulse, 196 lesions) are manually evaluated by microscopic and optical coherence tomography (OCT) visibility, as well as in histological sections immediately after the deposition of the laser energy. An optical coherence tomography system with 1.78 um axial resolution specifically developed to image thin retinal layers simultaneously to laser therapy is presented, and visibility thresholds of the laser lesions in OCT data and fundus imaging are compared. Optical coherence tomography scans are compared with histological sections to estimate the resolving power for small optical changes in the retinal layers, and real-time time-lapse scans during laser application are shown and analyzed quantitatively. Ultrahigh-resolution OCT inspection features a lesion visibility threshold 40–50 mW (17 reduction) lower than for visual inspection. With the new measurement system, 42 of the lesions that were invisible using state-of-the-art ophthalmoscopic methods could be detected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

composed and arr. for soli & chorus with English & German words and organ accompaniment / by A. Kaiser

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Radiolabelled glucagon-like peptide 1 (GLP-1) receptor agonists have recently been shown to successfully image benign insulinomas in patients. For the somatostatin receptor targeting of tumours, however, it was recently reported that antagonist tracers were superior to agonist tracers. The present study therefore evaluated various forms of the (125)iodinated-Bolton-Hunter (BH)-exendin(9-39) antagonist tracer for the in vitro visualization of GLP-1 receptor-expressing tissues in rats and humans and compared it with the agonist tracer (125)I-GLP-1(7-36)amide. METHODS Receptor autoradiography studies with (125)I-GLP-1(7-36)amide agonist or (125)I-BH-exendin(9-39) antagonist radioligands were performed in human and rat tissues. RESULTS The antagonist (125)I-BH-exendin(9-39) labelled at lysine 19 identifies all human and rat GLP-1 target tissues and GLP-1 receptor-expressing tumours. Binding is of high affinity and is comparable in all tested tissues in its binding properties with the agonist tracer (125)I-GLP-1(7-36)amide. For comparison, (125)I-BH-exendin(9-39) with the BH labelled at lysine 4 did identify the GLP-1 receptor in rat tissues but not in human tissues. CONCLUSION The GLP-1 receptor antagonist exendin(9-39) labelled with (125)I-BH at lysine 19 is an excellent GLP-1 radioligand that identifies human and rat GLP-1 receptors in normal and tumoural tissues. It may therefore be the molecular basis to develop suitable GLP-1 receptor antagonist radioligands for in vivo imaging of GLP-1 receptor-expressing tissues in patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We aimed to explore the effects of (90)Y-DOTATOC and (90)Y-DOTATOC plus (177)Lu-DOTATOC on survival of patients with metastasized gastrinoma. Patients with progressive metastasized gastrinoma were treated with repeated cycles of (90)Y-DOTATOC or with cycles alternating between (90)Y-DOTATOC and (177)Lu-DOTATOC until tumor progression or permanent toxicity. Multivariable Cox regression analyses were used to study predictors of survival. A total of 36 patients were enrolled; 30 patients received (90)Y-DOTATOC (median activity per patient 11.8GBq; range: 6.1-62.2GBq) and 6 patients received (90)Y-DOTATOC plus (177)Lu-DOTATOC (median activity per patient: 14.8GBq; range: 7.4-14.8GBq). Response was found in 26 patients (72.2%), including morphological (n=12, 33.3%), biochemical (n=14, 38.9%) and/or clinical response (n=6, 16.2%). A total of 21 patients (58.3%) experienced hematotoxicity grade 1/2, while 1 patient (2.8%) experienced hematotoxicity grade 3; no grade 4 hematotoxicity occurred. Furthermore, 2 patients (5.6%) developed grade 4 renal toxicity; no grade 5 renal toxicity occurred. Responders had a significantly longer median survival from time of enrollment than non-responders (45.1 months, range: 37.1-53.1 months vs. 12.6 months, range: 11.0-14.2, hazard ratio: 0.12 (0.027-0.52), p=0.005). Additionally, there was a trend towards longer median survival with (90)Y-DOTATOC plus (177)Lu-DOTATOC as compared to (90)Y-DOTATOC alone (60.2 months, range: 19.8-100.6 months vs. 27.0 months, range: 4.0-50.0, hazard ratio: 0.21 (0.01-3.98), p=0.16). Response to (90)Y-DOTATOC and (90)Y-DOTATOC plus (177)Lu-DOTATOC therapy is associated with a longer survival in patients with metastasized gastrinoma. Both treatment regimens are promising tools for management of progressive gastrinoma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To assess whether the association between reperfusion and improved clinical outcomes after stroke differs depending on the site of the arterial occlusive lesion (AOL). METHODS We pooled data from Solitaire With the Intention for Thrombectomy (SWIFT), Solitaire FR Thrombectomy for Acute Revascularisation (STAR), Diffusion and Perfusion Imaging Evaluation for Understanding Stroke Evolution Study 2 (DEFUSE 2), and Interventional Management of Stroke Trial (IMS III) to compare the strength of the associations between reperfusion and clinical outcomes in patients with internal carotid artery (ICA), proximal middle cerebral artery (MCA) (M1), and distal MCA (M2/3/4) occlusions. RESULTS Among 710 included patients, the site of the AOL was the ICA in 161, the proximal MCA in 389, and the distal MCA in 160 patients (M2 = 131, M3 = 23, and M4 = 6). Reperfusion was associated with an increase in the rate of good functional outcome (modified Rankin Scale [mRS] score 0-2) in patients with ICA (odds ratio [OR] 3.5, 95% confidence interval [CI] 1.7-7.2) and proximal MCA occlusions (OR 6.2, 95% CI 3.8-10.2), but not in patients with distal MCA occlusions (OR 1.4, 95% CI 0.8-2.6). Among patients with M2 occlusions, a subset of the distal MCA cohort, reperfusion was associated with excellent functional outcome (mRS 0-1; OR 2.2, 95% CI 1.0-4.7). CONCLUSIONS The association between endovascular reperfusion and better clinical outcomes is more profound in patients with ICA and proximal MCA occlusions compared to patients with distal MCA occlusions. Because there are limited data from randomized controlled trials on the effect of endovascular therapy in patients with distal MCA occlusions, these results underscore the need for inclusion of this subgroup in future endovascular therapy trials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The aim of this study was to evaluate the validity and the inter- and intra-examiner reliability of panoramic-radiograph-driven findings of different maxillary sinus anatomic variations and pathologies, which had initially been prediagnosed by cone beam computed tomography (CBCT). Methods: After pairs of two-dimensional (2D) panoramic and three-dimensional (3D) CBCT images of patients having received treatment at the outpatient department had been screened, the predefinition of 54 selected maxillary sinus conditions was initially performed on CBCT images by two blinded consultants individually using a questionnaire that defined ten different clinically relevant findings. Using the identic questionnaire, these consultants performed the evaluation of the panoramic radiographs at a later time point. The results were analyzed for inter-imaging differences in the evaluation of the maxillary sinus between 2D and 3D imaging methods. Additionally, two resident groups (first year and last year of training) performed two diagnostic runs of the panoramic radiographs and results were analyzed for inter- and intra-observer reliability. Results: There is a moderate risk for false diagnosis of findings of the maxillary sinus if only panoramic radiography is used. Based on the ten predefined conditions, solely maxillary bone cysts penetrating into the sinus were frequently detected differently comparing 2D to 3D diagnostics. Additionally, on panoramic radiographs, the inter-observer comparison demonstrated that basal septa were significantly often rated differently and the intra-observer comparison showed a significant lack in reliability in detecting maxillary bone cysts penetrating into the sinus. Conclusions: Panoramic radiography provides the most information on the maxillary sinus, and it may be an adequate imaging method. However, particular findings of the maxillary sinus in panoramic imaging may be based on a rather examiner-dependent assessment. Therefore, a persistent and precise evaluation of specific conditions of the maxillary sinus may only be possible using CBCT because it provides additional information compared to panoramic radiography. This might be relevant for consecutive surgical procedures; consequently, we recommend CBCT if a precise preoperative evaluation is mandatory. However, higher radiation dose and costs of 3D imaging need to be considered. Keywords: Panoramic radiography; Cone beam computed tomography; Maxillary sinus; Inter-imaging method differences; Inter-examiner reliability; Intra-examiner reliability

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Somatostatin receptor-targeted radiopeptide therapy is commonly performed using single radioisotopes. We evaluated the benefits and harms of combining radioisotopes in radiopeptide therapy in patients with neuroendocrine tumor. METHODS Using multivariable-adjusted survival analyses and competing risk analyses we evaluated outcomes in patients with neuroendocrine tumor receiving (90)Y-DOTATOC, (177)Lu-DOTATOC or their combination. RESULTS (90)Y-DOTATOC plus (177)Lu-DOTATOC treatment was associated with longer survival than (90)Y-DOTATOC (66.1 vs. 47.5 months; n = 1,358; p < 0.001) or (177)Lu-DOTATOC alone (66.1 vs. 45.5 months; n = 390; p < 0.001). (177)Lu-DOTATOC was associated with longer survival than (90)Y-DOTATOC in patients with solitary lesions (HR 0.3, range 0.1 - 0.7; n = 153; p = 0.005), extrahepatic metastases (HR 0.5, range 0.3 - 0.9; n = 256; p = 0.029) and metastases with low uptake (HR 0.1, range 0.05 - 0.4; n = 113; p = 0.001). (90)Y-DOTATOC induced higher hematotoxicity rates than combined treatment (9.5% vs. 4.0%, p = 0.005) or (177)Lu-DOTATOC (9.5 vs. 1.4%, p = 0.002). Renal toxicity was similar among the treatments. CONCLUSIONS Using (90)Y and (177)Lu might facilitate tailoring radiopeptide therapy and improve survival in patients with neuroendocrine tumors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To evaluate a low-cost, inertial sensor-based surgical navigation solution for periacetabular osteotomy (PAO) surgery without the line-of-sight impediment. METHODS Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient's pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient's anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient's pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography scan is used to visualize the updated orientation of the acetabular fragment. RESULTS Experiments with plastic bones (eight hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistically significant difference on the measurement of acetabular component reorientation. In all eight hip joints the mean absolute difference was below four degrees. CONCLUSION Using two commercially available inertial measurement units we show that it is possible to accurately measure the orientation (inclination and anteversion) of the acetabular fragment during PAO surgery and therefore to successfully eliminate the line-of-sight impediment that optical navigation systems have.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Digital developments have led to the opportunity to compose simulated patient models based on three-dimensional (3D) skeletal, facial, and dental imaging. The aim of this systematic review is to provide an update on the current knowledge, to report on the technical progress in the field of 3D virtual patient science, and to identify further research needs to accomplish clinical translation. MATERIALS AND METHODS Searches were performed electronically (MEDLINE and OVID) and manually up to March 2014 for studies of 3D fusion imaging to create a virtual dental patient. Inclusion criteria were limited to human studies reporting on the technical protocol for superimposition of at least two different 3D data sets and medical field of interest. RESULTS Of the 403 titles originally retrieved, 51 abstracts and, subsequently, 21 full texts were selected for review. Of the 21 full texts, 18 studies were included in the systematic review. Most of the investigations were designed as feasibility studies. Three different types of 3D data were identified for simulation: facial skeleton, extraoral soft tissue, and dentition. A total of 112 patients were investigated in the development of 3D virtual models. CONCLUSION Superimposition of data on the facial skeleton, soft tissue, and/or dentition is a feasible technique to create a virtual patient under static conditions. Three-dimensional image fusion is of interest and importance in all fields of dental medicine. Future research should focus on the real-time replication of a human head, including dynamic movements, capturing data in a single step.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the diagnostic accuracy of full-body linear X-ray scanning (LS) in multiple trauma patients in comparison to 128-multislice computed tomography (MSCT). Materials and Methods: 106 multiple trauma patients (female: 33; male: 73) were retrospectively included in this study. All patients underwent LS of the whole body, including extremities, and MSCT covering the neck, thorax, abdomen, and pelvis. The diagnostic accuracy of LS for the detection of fractures of the truncal skeleton and pneumothoraces was evaluated in comparison to MSCT by two observers in consensus. Extremity fractures detected by LS were documented. Results: The overall sensitivity of LS was 49.2 %, the specificity was 93.3 %, the positive predictive value was 91 %, and the negative predictive value was 57.5 %. The overall sensitivity for vertebral fractures was 16.7 %, and the specificity was 100 %. The sensitivity was 48.7 % and the specificity 98.2 % for all other fractures. Pneumothoraces were detected in 12 patients by CT, but not by LS. 40 extremity fractures were detected by LS, of which 4 fractures were dislocated, and 2 were fully covered by MSCT. Conclusion: The diagnostic accuracy of LS is limited in the evaluation of acute trauma of the truncal skeleton. LS allows fast whole-body X-ray imaging, and may be valuable for detecting extremity fractures in trauma patients in addition to MSCT. Key Points: • The overall sensitivity of LS for truncal skeleton injuries in multiple-trauma patients was < 50 %.• The diagnostic reference standard MSCT is the preferred and reliable imaging modality.• LS may be valuable for quick detection of extremity fractures. Citation Format: • Jöres APW., Heverhagen JT, Bonél H et al. Diagnostic Accuracy of Full-Body Linear X-Ray Scanning in Multiple Trauma Patients in Comparison to Computed Tomography. Fortschr Röntgenstr 2016; 188: 163 - 171.