954 resultados para tube furnace


Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the experimental evaluation of the acoustical impedance of a termination by the impedance-tube method at low frequencies, the length of the impedance tube is a problem. In the present paper, the method of exact analysis of standing waves developed by the authors for the stationary medium as well as for mean flow, has been extended for measurement of the acoustical impedance of a termination at low frequencies. The values of the tube attenuation factor and the wave number at the low frequency of interest are established from the experiment conducted, with the given impedance tube, at a higher frequency. Then, exciting the tube at the desired low frequency it is sufficient to measure sound pressure at three differenct locations (not necessarily the minima) in order to evaluate reflection coefficient and hence the impedance of the termination at that frequency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High frequency, miniature, pulse tube cryocoolers are extensively used in space applications because of their simplicity. Parametric studies of inertance type pulse tube cooler are performed with different length-to-diameter ratios of the pulse tube with the help of the FLUENT (R) package. The local thermal non-equilibrium of the gas and the matrix is taken into account for the modeling of porous zones, in addition to the wall thickness of the components. Dynamic characteristics and the actual mechanism of energy transfer in pulse are examined with the help of the pulse tube wall time constant. The heat interaction between pulse tube wall and the oscillating gas, leading to surface heat pumping, is quantified. The axial heat conduction is found to reduce the performance of the pulse tube refrigerator. The thermal non-equilibrium predicts a higher cold heat exchanger temperature compared to thermal equilibrium. The pressure drop through the porous medium has a strong non-linear effect due to the dominating influence of Forchheimer term over that of the linear Darcy term at high operating frequencies. The phase angle relationships among the pressure, temperature and the mass flow rate in the porous zones are also important in determining the performance of pulse tuberefrigerator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A numerical modelling technique for predicting the detailed performance of a double-inlet type two-stage pulse tube refrigerator has been developed. The pressure variations in the compressor, pulse tube, and reservoir were derived, assuming the stroke volume variation of the compressor to be sinusoidal. The relationships of mass flowrates, volume flowrates, and temperature as a function of time and position were developed. The predicted refrigeration powers are calculated by considering the effect of void volumes and the phase shift between pressure and mass flowrate. These results are compared with the experimental results of a specific pulse tube refrigerator configuration and an existing theoretical model. The analysis shows that the theoretical predictions are in good agreement with each other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an experimental investigation on the lateral impact performance of axially loaded concrete-filled double-skin tube (CFDST) columns. These columns have desirable structural and constructional properties and have been used as columns in building, legs of off shore platforms and as bridge piers. Since they could be vulnerable to impact from passing vessels or vehicles, it is necessary to understand their behaviour under lateral impact loads. With this in mind, an experimental method employing an innovative instrumented horizontal impact testing system (HITS) was developed to apply lateral impact loads whilst the column maintained a static axial pre-loading to examine the failure mechanism and key response parameters of the column. These included the time histories of impact force, reaction forces, global lateral deflection and permanent local buckling profile. Eight full scale columns were tested for key parameters including the axial load level and impact location. Based on the test data, the failure mode, peak impact force, impact duration, peak reaction forces, reaction force duration, column maximum and residual global deflections and column local buckling length, depth and width under varying conditions are analysed and discussed. It is evident that the innovative HITS can successfully test structural columns under the combination of axial pre-loading and impact loading. The findings on the lateral impact response of the CFDST columns can serve as a benchmark reference for their future analysis and design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A two stage Pulse Tube Cryocooler (PTC) is designed and fabricated which reaches a no-load temperature of 2.5K in the second stage and similar to 60 K in the first stage respectively. The system provides a cooling power of similar to 250 mW at 5K in the second stage. Stainless steel meshes (size 200) and lead (Pb) granules are used as the first stage regenerator materials and combination of Pb with Er3Ni / HoCu2 are used as the second stage regenerator materials. The system operates at 1.6 Hz using a 6 kW water cooled helium compressor. Studies conducted by varying the dimensions of Pulse Tubes and regenerators show that the dimensions of the Pulse Tubes are more critical to the performance of the Cryocooler than those of the regenerators. Experimental studies show that the optimum volume ratios of Er3Ni to Pb and HoCu2 to Pb in the second stage regenerator should be 3:2 and 2:3 respectively for the best performance. Further, systems with HoCu2 performed better than those with Er3Ni. The theoretical analysis of the system has been carried out using a simple isothermal model. The experimentally measured cooling powers are in good agreement with the theoretical predictions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research treats the lateral impact behaviour of composite columns, which find increasing use as bridge piers and building columns. It offers (1) innovative experimental methods for testing structural columns, (2) dynamic computer simulation techniques as a viable tool in analysis and design of such columns and (3) significant new information on their performance which can be used in design. The research outcomes will enable to protect lives and properties against the risk of vehicular impacts caused either accidentally or intentionally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an experimental investigation on the lateral impact response of axially loaded concrete filled double skin tube (CFDST) columns. A total of four test series are being conducted at Queensland University of Technology using a novel horizontal impact-testing rig. The test results reported in this paper are from the first test series, where the columns are pinned at both ends and impacted at mid-span. In the next three series, effects of support conditions, impact location and repeated impact will be treated. The main objectives of the current paper are to describe the innovative testing procedure and provide some insight into the lateral impact behavior and failure of simply supported axially pre-loaded CFDST columns. The results include time histories of impact forces, reaction forces, axial force and global lateral deflection. Based on the test data, the failure mode, peak impact force, peak reaction forces, maximum deflection and residual deflection, with and without axial load, are analyzed and discussed. The findings of this study will serve as a benchmark reference for future analysis and design of CFDST columns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In-flight collection of air, pre-cooling, liquefaction and separation of liquid oxygen (LOX) are key technologies for futuristic launch vehicles, Vortex tube technology is one of the few potential technologies for this application. Extensive studies have been carried out on straight and conical vortex tubes for developing vortex tube technology for high purity LOX separation. Studies show that 12mm. diameter conical vortex tube with L/D of 10 could achieve LOX purity of similar to 96% with separation efficiency of similar to 14% indicating that it is not possible to obtain both high LOX purity and high separation efficiency simultaneously in a single vortex tube. However, it is possible to achieve both high LOX purity and separation efficiency by staging of vortex tubes. LOX purity of 96% and separation efficiency of similar to 73.5% has been achieved for second stage vortex tube supplied with pre-cooled air having 60% oxygen purity. LOX purity has been further increased to 97% by applying controlled heating power over liquid oxygen flowing discharge surface of the vortex tube.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study was to clarify the occurrence, and etiological and prognostic factors of primary fallopian tube carcinoma (PFTC). We studied the sociodemographic determinants of the incidence of PFTC in Finland and the role of chlamydial infections and human papillomavirus infections as risk factors for PFTC. Serum tumor markers were studied as prognostic factors for PFTC. We also evaluated selected reproductive factors (parity, sterilization and hysterectomy) as risk or protective factors of PFTC. The risks of second primary cancers after PFTC were also studied. The age-adjusted incidence of PFTC in Finland increased to 5.4 / 1,000,000 in 1993 97. The incidence rate was higher in the cities, but the relative rise was higher in rural areas. Women in the two highest social classes showed a 1.8 fold incidence compared with those in the lowest. Women in agriculture and those not working outside the home showed only half the PFTC incidence of those in higher socioeconomic occupations. Pretreatment serum concentrations of hCGβ, CA125 and TATI were evaluated as prognostic markers for PFTC. Elevated hCGβ values (above the 75th percentile, 3.5 pmol/L; OR 2.49, 95% CI 1.22 5.09), stage and histology were strong independent prognostic factors for PFTC. The effects of parity, sterilization and hysterectomy on the risk of PFTC were studied in a case control-study with 573 PFTC cases from the Finnish Cancer Registry. In multivariate analysis parity was the only significant protective factor as regards PFTC, with increasing protection associated with increasing number of deliveries. In univariate analysis sterilization gave borderline protection against PFTC and the protective effect increased with time since the operation. In multivariate analysis the protection did not reach statistical significance. Chlamydial and human papillomavirus (HPV) infections were studied in two separate seroepidemiological case-control studies with 78 PFTC patients. The incidence of women with positive HPV or chlamydial serology was the same in PFTC patients and in the control group and was not found to be a risk factor for PFTC. Finally, the possible risk of a second primary cancer after diagnosis and treatment of PFTC in a cohort of 2084 cases from 13 cancer registries followed for second primary cancers within the period 1943 2000 was studied. In PFTC patients, second primary cancers were 36% more common than expected (SIR 1.36, 95% CI 1.13 1.63). In conclusion, the incidence of PFTC has increased in Finland, especially in higher social classes and among those in certain occupations. Elevated serum hCGβ reflect a worsened prognosis. Parity is a clear protective factor, as is previous sterilization. After PFTC there is a risk of second primary cancers, especially colorectal, breast, lung and bladder cancers and non-lymphoid leukemia. The excess of colorectal and breast cancers after PFTC may indicate common effects of earlier treatments, or they could reflect common effects of lifestyle or genetic, immunological or environmental background.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A miniature furnace suitable for routine collection of x-ray data up to 1000°C from single crystals on the Hilger and Watts linear diffractometer, without restricting the normally allowed region of reciprocal space on the diffractometer, is described. The crystal is heated primarily by radiation from a surrounding current-heated, stationary platinum coil wound on a silica bracket. The coil is split at its middle to provide a 4 mm gap for crystal mounting and x-irradiation. The crystal, mounted on a standard goniometer head, can be rotated and centred freely, as in the room temperature case. There is no need for any radiation shields or water-cooling arrangement. Investigations up to 1500°C are possible with slight modifications of the furnace.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A two-stage pulse tube cryocooler (PTC) which produces a no-load temperature of similar to 2.5 K in its second stage at an operating frequency of 1.6 Hz has been designed and fabricated. The second stage of the system provides a refrigeration power of similar to 250 mW at 5.0 K. The system uses stainless steel meshes (mesh size 200) along with lead (Pb) granules and combinations of Pb, Er3Ni, and HoCu2 as the first and second stage regenerator materials, respectively. Experimental studies have been carried out on different pulse tube configurations by varying the dimensions of the pulse tubes and regenerators to arrive at the best one, which leads to the lowest no-load second stage cold head temperature. Using this configuration, detailed experimental studies have been conducted by varying the volume percentage ratios of the second stage regenerator materials such as HoCu2, Er3Ni, and Pb (with an average grain size of similar to 250 mu m). This article presents the results of our experimental studies on cryocoolers with the regenerator material arranged in layered structures. Comparative studies have also been presented for specific cases where the regenerator materials are arranged as a homogeneous mixture in the second stage. The experimental results clearly indicate that the design of PTCs should use only layered structures of regenerator materials and not homogenous mixtures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims. Following an earlier proposal for the origin of twist in the magnetic fields of solar active regions, we model the penetration of a wrapped up background poloidal field into a toroidal magnetic flux tube rising through the solar convective zone.Methods. The rise of the straight, cylindrical flux tube is followed by numerically solving the induction equation in a comoving Lagrangian frame, while an external poloidal magnetic field is assumed to be radially advected onto the tube with a speed corresponding to the rise velocity.Results. One prediction of our model is the existence of a ring of reverse current helicity on the periphery of active regions. On the other hand, the amplitude of the resulting twist depends sensitively on the assumed structure ( diffuse vs. concentrated/intermittent) of the active region magnetic field right before its emergence, and on the assumed vertical profile of the poloidal field. Nevertheless, in the model with the most plausible choice of assumptions a mean twist comparable to the observations results.Conclusions. Our results indicate that the contribution of this mechanism to the twist can be quite significant, and under favourable circumstances it can potentially account for most of the current helicity observed in active regions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synthesis of cost-optimal shell-and-tube heat exchangers is a difficult task since it involves a large number of parameters. An attempt is made in this article to simplify the process of choosing the parameter values that will minimize the cost of any heat exchanger satisfying a given heat duty and a particular set of constraints. The simplification is based on decoupling of the geometric and the thermal aspects of the problem. The concept of curves for cost-optimal design is introduced and is shown to simplify the synthesis process for shell-and-tube heat exchangers.