799 resultados para topography measurement
Resumo:
We outline a scheme to accomplish measurements of a solid state double well system (DWS) with both one and two electrons in nonlocalized bases. We show that, for a single particle, measuring the local charge distribution at the midpoint of a DWS using a SET as a sensitive electrometer amounts to performing a projective measurement in the parity (symmetric/antisymmetric) eigenbasis. For two-electrons in a DWS, a similar configuration of SET results in close-to-projective measurement in the singlet/triplet basis. We analyze the sensitivity of the scheme to asymmetry in the SET position for some experimentally relevant parameter, and show that it is experimentally realizable.
Resumo:
We generalize a proposal for detecting single-phonon transitions in a single nanoelectromechanical system (NEMS) to include the intrinsic anharmonicity of each mechanical oscillator. In this scheme two NEMS oscillators are coupled via a term quadratic in the amplitude of oscillation for each oscillator. One NEMS oscillator is driven and strongly damped and becomes a transducer for phonon number in the other measured oscillator. We derive the conditions for this measurement scheme to be quantum limited and find a condition on the size of the anharmonicity. We also derive the relation between the phase diffusion back-action noise due to number measurement and the localization time for the measured system to enter a phonon-number eigenstate. We relate both these time scales to the strength of the measured signal, which is an induced current proportional to the position of the read-out oscillator.
Resumo:
A measure of dimensional anxiety specifically designed for use in older people is urgently needed. Such a measure could be used in a variety of settings to screen for anxiety disorders and to measure response to treatment in older people with established anxiety disorders. We have developed a new instrument to measure generalized anxiety symptoms in older people, the Geriatric Anxiety Inventory (GAI). This new instrument uses plain language, minimises somatic items and has a dichotomous response scale. Although it is a self-report measure, it may readily be administered to frail and mildly cognitively impaired older people by nursing staff. The development and initial validation of the GAI will be described. The scale was administered to community samples as well as patients with anxiety, depression, and mild cognitive impairment. Reliability was high and validity sound when compared to a range of standard anxiety instruments, and the instrument was well-tolerated among these cohorts. Sensitivity, specificity and cut-off scores for community and impatient samples will be presented.
Resumo:
Traumatic brain injury (TBI) may result in a variety of cognitive, behavioural and physical impairments. Dizziness has been reported in up to 80% of cases within the first few days after injury. The literature was reviewed to attempt to delineate prevalence of dizziness as a symptom, impairments causing dizziness, the functional limitations it causes and its measurement. The literature provides widely differing estimates of prevalence and vestibular system dysfunction appears to be the best reported of impairments contributing to this symptom. The variety of results is discussed and other possible causes for dizziness were reviewed. Functional difficulties caused by dizziness were not reported for this population in the literature and review of cognitive impairments suggests that existing measurement tools for dizziness may be problematic in this population. Research on the functional impact of dizziness in the TBI population and measurement of these symptoms appears to be warranted.
Resumo:
Piezoelectric polymers have been used to form the basis of dynamic strain gauges for the detection of stress waves. The linearity of response was tested using a split Hopkinson pressure bar arrangement. The results obtained illustrate the effectiveness of piezoelectric film strain gauges in the measurement of axial stress waves.
Resumo:
A single-beam gradient trap could potentially be used to hold a stylus for scanning force microscopy. With a view to development of this technique, we modeled the optical trap as a harmonic oscillator and therefore characterized it by its force constant. We measured force constants and resonant frequencies for 1-4-mu m-diameter polystyrene spheres in a single-beam gradient trap using measurements of back-scattered light. Force constants were determined with both Gaussian and doughnut laser modes, with powers of 3 and 1 mW, respectively. Typical values for spring constants were measured to be between 10(-6) and 4 x 10(-6) N/m. The resonant frequencies of trapped particles were measured to be between 1 and 10 kHz, and the rms amplitudes of oscillations were estimated to be around 40 nm. Our results confirm that the use of the doughnut mode for single-beam trapping is more efficient in the axial direction. (C) 1996 Optical Society of America.
Resumo:
Objectives: The aim of this study was to determine whether the addition of the measurement of bilateral hip bone mineral density (BMD) has an impact on indications for osteoporosis (OP) treatment in community-dwelling elderly individuals, based on criteria from the National Osteoporosis Foundation (NOF). Methods: In total, 605 consecutive community-dwelling elderly individuals who were 65 years and older were evaluated. Dual energy X-ray absorptiometry was used to determine the lowest T-score in the lumbar spine + unilateral hip, the bilateral hips, and the lumbar spine + bilateral hips. Risk factors associated with the lowest T-score in these three conditions were applied to indicate treatment in accordance with NOF criteria. McNemar`s test was used to assess the difference of adding bilateral hip BMD measurements. Results: There was a significant difference in the frequency of pharmacological indication using NOF criteria together with the lowest T-score for the three tests (72.8% for lumbar spine + bilateral hips and 71.2% for lumbar spine + unilateral hip; p=0.002). A higher frequency of treatment indication was also observed for lumbar spine + unilateral hip (71.2%) compared to bilateral hips (61.1%) (p<0.001). The discrepancies in treatment appeared to be more evident in women when analyzed by gender distribution. Conclusion: Our finding supports the theory that evaluation of the bilateral hips with the lumbar spine seems to be more sensitive measure for identifying patients with an osteoporosis treatment indication. Furthermore, despite the well-known artifact in the lumbar spine, this site should not be excluded when determining the indication for OP treatment in elderly people. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The technique of frequency-resolved optical gating is used to characterize the intensity and the phase of picosecond pulses after propagation through 700 m of fiber at close to the zero-dispersion wavelength. Using the frequency-resolved optical gating technique, we directly measure the severe temporal distortion resulting from the interplay between self-phase modulation and higher-order dispersion in this regime. The measured intensity and phase of the pulses after propagation are found to be in good agreement with the predictions of numerical simulations with the nonlinear Schrodinger equation. (C) 1997 Optical Society of America.
Resumo:
Aims The excretion of phospholipids in urine may be a marker of the early renal toxicity of the aminoglycoside antibiotics. Urinary phospholipids are formed in myeloid bodies which develop in the lysosomes of proximal tubules during treatment with the aminoglycosides, and overflow into the urine. Methods Published assays were modified in order to measure the total phospholipid concentrations in human urine. Phospholipids were extracted from freeze-dried urine samples, digested in concentrated sulphuric acid, and the inorganic phosphorus content determined by complexing with ammonium molybdate and measuring the absorbance at 820 nm. Ten septicaemic patients treated with gentamicin for 5-7 days had significantly higher urine phospholipid concentrations than 10 healthy untreated control subjects (P<0.0001). There was a negative Linear relationship between phospholipid excretion and creatinine clearance (r(2) = 0.71). Results In 34 patients with acute pyelonephritis, increased phospholipid concentrations were observed prior to treatment compared with healthy controls (P<0.001) and did not alter during treatment with gentamicin. However, the phospholipid concentrations decreased significantly after treatment was completed (P<0.03). Conclusions These studies suggest that urinary phospholipids may indicate early aminoglycoside toxicity but with poor specificity, as many of the infections being treated may themselves be associated with phospholipiduria.
Resumo:
The aim of this study was to confirm that the radiation doses received by attendants who manually restrain infants during fluoroscopic procedures are low. Doses to the hands and neck of three radiologists and three nurses performing or assisting at all the fluoroscopic procedures in a children's hospital were measured for 1 month using thermoluminescent dosemeters. All fluoroscopy on children at this hospital is performed without an antiscatter grid. Total doses for the neck ranged from 20 to 50 mu Sv per week and for hands from 40 to 210 mu Sv per week. These doses were shared by the three radiologists and the three nurses. Individual doses received per staff member are very small when compared with the doses received by interventional radiology staff. Doses received by staff in this study were of the order of 5% of the limit advised by the National Health and Medical Research Council of Australia (NHMRC) for radiation workers. Nurses received larger doses than radiologists and steps will be taken to reduce this dose further.
Resumo:
Analysis of a major multi-site epidemiologic study of heart disease has required estimation of the pairwise correlation of several measurements across sub-populations. Because the measurements from each sub-population were subject to sampling variability, the Pearson product moment estimator of these correlations produces biased estimates. This paper proposes a model that takes into account within and between sub-population variation, provides algorithms for obtaining maximum likelihood estimates of these correlations and discusses several approaches for obtaining interval estimates. (C) 1997 by John Wiley & Sons, Ltd.
Resumo:
The world's deep oceans are home to a number of teleosts with asymmetrical or tubular eyes. These immobile eyes possess large spherical lenses and subtend a large binocular visual field directed either dorsally or rostrally. Derived from a lateral non-tubular eye, the tubular eye is comprised of a thick main retina, subserving the rostrally or dorsally directed binocular visual field, and a thin accessory retina subserving, the lateral, monocular visual field. The main retina is thought to receive a focussed image, while the accessory retina is too close to the lens for a focussed image to be received. Several species also possess retinal diverticula, which are small evaginations of differentiated retina located in the rostrolateral wall of the eye and thought to increase the visual field. In order to investigate the spatial resolving power of these retinae (main, accessory and diverticulum), the distribution of cells within the ganglion cell layer was analysed from retinal wholemounts and sectioned material in ten species representing four genera. In all species, the main retina possesses a marked increase in cell density towards a specialised retinal region (area centralis), with a centro-peripheral gradient range between 7.1 and 60:1 and a peak density range of between 30 and 55 x 10(3) cells per mm(2). The accessory retinae and the transitional zone between the main and accessory retinae possess relatively low cell densities (between 1 and 10 x 10(3) cells per mm(2)) and lack an area centralis. Retinal diverticula examined in four species possess mean ganglion cell densities of between 7.2 and 109.4 x 10(3) cells per mm(2). Analyses of soma areas show that the ganglion cell layer of most species possesses cells with areas in a range of 8.0 to 15.4 mu m(2) in the main retina and between 15.1 and 17.4 mu m(2) in the accessory retina. The peak spatial resolving power of the main retina of the ten species varies from 4.1 to 9.1 cycles per degree. The positions of the retinal areae centrales relative to each species' binocular visual field are discussed in relation to what is known of feeding behaviour of these fishes in the deep-sea.
Resumo:
BACKGROUND: In patients with supraclavicular injuries of the brachial plexus, the suprascapular nerve (SSN) is frequently reconstructed with a sural nerve graft coapted to C5. As the C5 cross-sectional diameter exceeds the graft diameter, inadequate positioning of the graft is possible. OBJECTIVE: To identify a specific area within the C5 proximal stump that contains the SSN axons and to determine how this area could be localized by the nerve surgeon, we conducted a microanatomic study of the intraplexal topography of the SSN. METHODS: The right-sided C5 and C6 roots, the upper trunk with its divisions, and the SSN of 20 adult nonfixed cadavers were removed and fixed. The position and area occupied by the SSN fibers inside C5 were assessed and registered under magnification. RESULTS: The SSN was monofascicular in all specimens and derived its fibers mainly from C5. Small contributions from C6 were found in 12 specimens (60%). The mean transverse area of C5 occupied by SSN fibers was 28.23%. In 16 specimens (80%), the SSN fibers were localized in the ventral (mainly the rostroventral) quadrants of C5, a cross-sectional area between 9 o`clock and 3 o`clock from the surgeon`s intraoperative perspective. CONCLUSION: In reconstruction of the SSN with a sural nerve graft, coaptation should be performed in the rostroventral quadrant of C5 cross-sectional area (between 9 and 12 o`clock from the nerve surgeon`s point of view in a right-sided brachial plexus exploration). This will minimize axonal misrouting and may improve outcome.
Resumo:
PURPOSE: To evaluate topography-guided photorefractive keratectomy (PRK) for correcting hyperopia and astigmatism after radial keratotomy (RK). METHODS., Prospective study of 12 consecutive patients (19 eyes) who were treated with topography-guided PRK with 0.02% mitomycin C using an Asclepion-Meditec MEL-70 excimer laser with a 9.5-mm ablation zone. All eyes were operated by the same surgeon and followed for 1 year. RESULTS: Thirteen eyes had complete epithelialization by day 7 and all eyes by day 10. At 1 year, uncorrected visual acuity was 20/25 or better in 42.1% of eyes and 20/40 or better in 68.4%. Preoperative mean spherical equivalent refraction was +3.80 +/- 2.47 diopters (D) and +0.24 +/- 2.36 D (P <.001) 1 year postoperative, with 47.4% of eyes being within +/- 1.00 D and 73.7% within +/- 2.00 D. Preoperative mean cylinder was -2.30 +/- 1.41 D and -0.62 +/- 0.73 D (P <.1001) 1 year postoperative. At 1 year, 68.4% of eyes gained at least 1 line of best-spectacle corrected visual acuity, 36.8% gained more than 1 line, and only 2 eyes lost 1 line (one due to corneal haze). Three eyes developed central haze. Mean regression from 6 to 12 months in these 3 eyes was +1.83 D and in the remaining 16 eyes was -0.50 D. CONCLUSIONS: Topography-guided PRK with mitomycin C was safe and reasonably effective for the treatment of hyperopia after RK [J Refract Surg. 2008;24:911-922.]