991 resultados para positive pressure


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this preliminary study was to verify the antibacterial potential of cetylpyridinium chloride (CPC) in root canals infected by Enterococcus faecalis. Forty human maxillary anterior teeth were prepared and inoculated with E. faecalis for 60 days. The teeth were randomly assigned to the following groups: 1: Root canal preparation (RCP) + 0.1% CPC with positive-pressure irrigation (PPI, Conventional, NaviTip®); 2: RCP + 0.2% CPC PPI; 3: RCP + 2.5% NaOCl PPI; 4: RCP + 2.5% NaOCl with negative-pressure irrigation system (NPI, EndoVac®); 5: Positive control; and 6: Negative control. Four teeth of each experimental group were evaluated by culture and 4 by scanning electron microscopy (SEM). In all teeth, the root canals were dried and filled with 17% EDTA (pH 7.2) for 3 min for smear layer removal. Samples from the infected root canals were collected and immersed in 7 mL of Letheen Broth (LB), followed by incubation at 37°C for 48 h. Bacterial growth was analyzed by turbidity of culture medium and then observed with a UV spectrophotometer. The irrigating solutions were further evaluated for antimicrobial effect by an agar diffusion test.The statistical data were treated by means, standard deviation, Kruskal-Wallis test and analysis of variance. Significance level was set at 5%. The results showed the presence of E. faecalis after root canal sanitization. The number of bacteria decreased after the use of CPC. In the agar diffusion test, CPC induced large microbial inhibition zones, similar to 2% chlorhexidine and large than 2.5% NaOCl. In conclusion, cetylpyridinium chloride showed antibacterial potential in endodontic infection with E. faecalis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Spontaneous dural arterio-venous fistulas can imperceptibly develop over a long time period before they suddenly develop symptoms like bruit, loss of vision, exophthalmos and conjunctival injection. We present the rare case of an occult, para-infectious, dural arterio-venous fistula which became symptomatic after endoscopic sinus surgery. Conjunctival injection and slight exophthalmos developed due to decompensation of venous drainage probably by intraoperative positioning of the patient, positive pressure ventilation and nasal packing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIM: The importance of ventilatory support during cardiac arrest and basic life support is controversial. This experimental study used dynamic computed tomography (CT) to assess the effects of chest compressions only during cardiopulmonary resuscitation (CCO-CPR) on alveolar recruitment and haemodynamic parameters in porcine model of ventricular fibrillation. MATERIALS AND METHODS: Twelve anaesthetized pigs (26+/-1kg) were randomly assigned to one of the following groups: (1) intermittent positive pressure ventilation (IPPV) both during basic life support and advanced cardiac life support, or (2) CCO during basic life support and IPPV during advanced cardiac life support. Measurements were acquired at baseline prior to cardiac arrest, during basic life support, during advanced life support, and after return of spontaneous circulation (ROSC), as follows: dynamic CT series, arterial and central venous pressures, blood gases, and regional organ blood flow. The ventilated and atelectatic lung area was quantified from dynamic CT images. Differences between groups were analyzed using the Kruskal-Wallis test, and a p<0.05 was considered statistically significant. RESULTS: IPPV was associated with cyclic alveolar recruitment and de-recruitment. Compared with controls, the CCO-CPR group had a significantly larger mean fractional area of atelectasis (p=0.009), and significantly lower PaO(2) (p=0.002) and mean arterial pressure (p=0.023). The increase in mean atelectatic lung area observed during basic life support in the CCO-CPR group remained clinically relevant throughout the subsequent advanced cardiac life support period and following ROSC, and was associated with prolonged impaired haemodynamics. No inter-group differences in myocardial and cerebral blood flow were observed. CONCLUSION: A lack of ventilation during basic life support is associated with excessive atelectasis, arterial hypoxaemia and compromised CPR haemodynamics. Moreover, these detrimental effects remain evident even after restoration of IPPV.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Peru is a developing country with abundant fresh water resources, yet the lack of infrastructure leaves much of the population without access to safe water for domestic uses. The author of this report was a Peace Corps Volunteer in the sector of water & sanitation in the district of Independencia, Ica, Peru. Independencia is located in the arid coastal region of the country, receiving on average 15 mm of rain annually. The water source for this district comes from the Pisco River, originating in the Andean highlands and outflowing into the Pacific Ocean near the town of Pisco, Peru. The objectives of this report are to assess the water supply and sanitation practices, model the existing water distribution system, and make recommendations for future expansion of the distribution system in the district of Independencia, Peru. The assessment of water supply will be based on the results from community surveys done in the district of Independencia, water quality testing done by a detachment of the U.S. Navy, as well as on the results of a hydraulic model built in EPANET 2.0 to represent the distribution system. Sanitation practice assessments will be based on the surveys as well as observations from the author while living in Peru. Recommendations for system expansions will be made based on results from the EPANET model and the municipality’s technical report for the existing distribution system. Household water use and sanitation surveys were conducted with 84 families in the district revealing that upwards of 85% store their domestic water in regularly washed containers with lids. Over 80% of those surveyed are drinking water that is treated, mostly boiled. Of those surveyed, over 95% reported washing their hands and over 60% mentioned at least one critical time for hand washing when asked for specific instances. From the surveys, it was also discovered that over 80% of houses are properly disposing of excrement, in either latrines or septic tanks. There were 43 families interviewed with children five years of age or under, and just over 18% reported the child had a case of diarrhea within the last month at the time of the interview. Finally, from the surveys it was calculated that the average water use per person per day is about 22 liters. Water quality testing carried out by a detachment of the U.S. Navy revealed that the water intended for consumption in the houses surveyed was not suitable for consumption, with a median E. coli most probable number of 47/100 ml for the 61 houses sampled. The median total coliforms was 3,000 colony forming units per 100 ml. EPANET was used to simulate the water delivery system and evaluate its performance. EPANET is designed for continuous water delivery systems, assuming all pipes are always flowing full. To account for the intermittent nature of the system, multiple EPANET network models were created to simulate how water is routed to the different parts of the system throughout the day. The models were created from interviews with the water technicians and a map of the system created using handheld GPS units. The purpose is to analyze the performance of the water system that services approximately 13,276 people in the district of Independencia, Peru, as well as provide recommendations for future growth and improvement of the service level. Performance evaluation of the existing system is based on meeting 25 liters per person per day while maintaining positive pressure at all nodes in the network. The future performance is based on meeting a minimum pressure of 20 psi in the main line, as proposed by Chase (2000). The EPANET model results yield an average nodal pressure for all communities of 71 psi, with a range from 1.3 – 160 psi. Thus, if the current water delivery schedule obtained from the local municipality is followed, all communities should have sufficient pressure to deliver 25 l/p/d, with the exception of Los Rosales, which can only supply 3.25 l/p/d. However, if the line to Los Rosales were increased from one to four inches, the system could supply this community with 25 l/p/d. The district of Independencia could greatly benefit from increasing the service level to 24-hour water delivery and a minimum of 50 l/p/d, so that communities without reliable access due to insufficient pressure would become equal beneficiaries of this invaluable resource. To evaluate the feasibility of this, EPANET was used to model the system with a range of population growth rates, system lifetimes, and demands. In order to meet a minimum pressure of 20 psi in the main line, the 6-inch diameter main line must be increased and approximately two miles of trench must be excavated up to 30 feet deep. The sections of the main line that must be excavated are mile 0-1 and 1.5-2.5, and the first 3.4 miles of the main line must be increased from 6 to 16 inches, contracting to 10 inches for the remaining 5.8 miles. Doing this would allow 24-hour water delivery and provide 50 l/p/d for a range of population growth rates and system lifetimes. It is expected that improving the water delivery service would reduce the morbidity and mortality from diarrheal diseases by decreasing the recontamination of the water due to transport and household storage, as well as by maintaining continuous pressure in the system to prevent infiltration of contaminated groundwater. However, this expansion must be carefully planned so as not to affect aquatic ecosystems or other districts utilizing water from the Pisco River. It is recommended that stream gaging of the Pisco River and precipitation monitoring of the surrounding watershed is initiated in order to begin a hydrological study that would be integrated into the district’s water resource planning. It is also recommended that the district begin routine water quality testing, with the results available to the public.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: We report the results and complications associated with standardized intraoperative management designed for the prevention of hemodynamically relevant venous air embolism during surgery performed in the semisitting position. METHODS: A protocol for preoperative evaluation and intraoperative monitoring was developed and applied in 187 consecutive patients who underwent surgery in the semisitting position between 1999 and 2004. The protocol included preoperative transesophageal echocardiography examination (TEE), intraoperative TEE monitoring, catheterization of the right atrium and a combination of fluid input, positive end expiratory pressure, and standardized positioning aiming at a positive pressure in the transverse and sigmoid sinuses. Data were collected retrospectively from the charts and intraoperative anesthesiological protocols of the patients for the incidence of clinically relevant air embolism (i.e., TEE-diagnosed air embolism plus a decrease in end tidal CO2 or hemodynamic changes) and other complications related to the semisitting position. RESULTS: Three cases (1.6%) of relevant venous air embolism occurred in 187 patients. Only 1 case (0.5%) was hemodynamically relevant, with temporary arterial blood pressure decrease and heart rate increase. Pneumatocephalus leading to lethargy was a frequent postoperative finding, which resolved spontaneously in all except 1 patient with epileptic seizure and oculomotor nerve palsy attributable to space-occupying subdurally trapped air, which had to be treated surgically. There was no permanent morbidity or mortality related to the semisitting position. CONCLUSION: Fear of massive venous air embolism is one reason for dramatic decline in the use of the semisitting position in neurosurgical practice. We found that strict adherence to a standardized protocol using TEE monitoring before and during surgery; exclusion of patients with patent foramen ovale; and a combination of positive end expiratory pressure, fluid input, and a standardized position aiming a positive pressure in the transverse and sigmoid sinuses helped to greatly minimize this complication to a rate of 0.5% for hemodynamically relevant events.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Spontaneous contractions of the fetal airways are a well recognized but poorly characterized phenomenon. In the present study spontaneous narrowing of the airways was analyzed in freshly isolated lungs from early to late gestation in fetal pigs and rabbits and in cultured fetal mouse lungs. Propagating waves of contraction traveling proximal to distal were observed in fresh lungs throughout gestation which displaced the lung liquid along the lumen. In the pseudoglandular and canalicular stages (fetal pigs) the frequency ranged from 2.3 to 3.3 contractions/min with a 39 to 46% maximum reduction of lumen diameter. In the saccular stage (rabbit) the frequency was 10 to 12/min with a narrowing of approximately 30%. In the organ cultures the waves of narrowing started at the trachea in whole lungs, or at the main bronchus in lobes (5.2 +/- 1.5 contractions/min, 22 +/- 8% reduction of lumen diameter), and as they proceeded distally along the epithelial tubes the luminal liquid was shifted toward the terminal tubules, which expanded the endbuds. As the tubules relaxed the flow of liquid was reversed. Thus the behavior of airway smooth muscle in the fetal lung is phasic in type (like gastrointestinal muscle) in contrast to that in postnatal lung, where it is tonic. An intraluminal positive pressure of 2.33 +/- 0.77 cm H(2)O was recorded in rabbit fetal trachea. It is proposed that the active tone of the smooth muscle maintains the positive intraluminal pressure and acts as a stimulus to lung growth via the force exerted across the airway wall and adjacent parenchyma. The expansion of the compliant endbuds by the fluid shifts at the airway tip may promote their growth into the surrounding mesenchyme.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A one-year-old healthy sheep received an implant stenting the mural ('posterior') leaflet of the mitral valve. The experiment was authorized by the Cantonal Ethical Committee. The surgery was performed on the open, beating heart during cardiopulmonary bypass (CPB). Management of anaesthesia was based on isoflurane with mechanical intermittent positive pressure ventilation (IPPV) of the lungs, combined with intercostal nerve blocks and intravenous fentanyl and lidocaine. Marked cardiovascular depression occurred towards the end of CPB time and required high doses of dopamine, dobutamine, lidocaine and ephedrine to allow for weaning off the CPB pump. Moreover, severe pulmonary dysfunction developed when IPPV was re-initiated after CPB. Hypoxaemia persisted throughout the recovery from general anaesthesia. Multiple organ failure developed gradually during the three postoperative days, leading to euthanasia of the animal. As described in this case, marked lung injury associated with some degree of failure of other vital organs may occur in sheep after CPB. Intraoperative cardiorespiratory complications when weaning-off may indicate the development of 'post-pump syndrome'.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

UNLABELLED Evidence for target values of arterial oxygen saturation (SaO2), CO2, and pH has changed substantially over the last 20 years. A representative survey concerning treatment strategies in extremely low-birth-weight infants (ELBW) was sent to all German neonatal intensive care units (NICUs) treating ELBW infants in 1997. A follow-up survey was conducted in 2011 and sent to all NICUs in Germany, Austria, and Switzerland. During the observation period, NICUs targeting SaO2 of 80, 85, and 90 % have increased, while units aiming for 94 and 96 % decreased (all p < 0.001). Similarly, NICUs aiming for pH 7.25 or lower increased, while 7.35 or higher decreased (both p < 0.001). Furthermore, more units targeted a CO2 of 50 mmHg (7.3 kPa) or higher (p < 0.001), while fewer targeted 40 or 35 mmHg (p < 0.001). Non-invasive ventilation (NIV) was used in 80.2 % of NICUs in 2011. The most frequently used ventilation modes were synchronized intermittent mandatory ventilation (SIMV) (67.5 %) and intermittent positive pressure ventilation (IPPV) (59.7 %) in 1997 and SIMV (77.2 %) and synchronized intermittent positive pressure ventilation (SIPPV) (26.8 %) in 2011. NICUs reporting frequent or always use of IPPV decreased to 11.0 % (p < 0.001). SIMV (77.2 %) and SIPPV (26.8 %) did not change from 1997 to 2011, while high-frequency oscillation (HFO) increased from 9.1 to 19.7 % (p = 0.018). Differences between countries, level of care, and size of the NICU were minimal. CONCLUSIONS Target values for SaO2 decreased, while CO2 and pH increased significantly during the observation period. Current values largely reflect available evidence at time of the surveys. WHAT IS KNOWN • Evidence concerning target values of oxygen saturation, CO 2 , and pH in extremely low-birth-weight infants has grown substantially. • It is not known to which extent this knowledge is transferred into clinical practice and if treatment strategies have changed. WHAT IS NEW • Target values for oxygen saturation in ELBW infants decreased between 1997 and 2011 while target values for CO 2 and pH increased. • Similar treatment strategies existed in different countries, hospitals of different size, or university versus nonuniversity hospitals in 2011.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The patch-clamp technique allows currents to be recorded through single ion channels in patches of cell membrane in the tips of glass pipettes. When recording, voltage is typically applied across the membrane patch to drive ions through open channels and to probe the voltage-sensitivity of channel activity. In this study, we used video microscopy and single-channel recording to show that prolonged depolarization of a membrane patch in borosilicate pipettes results in delayed slow displacement of the membrane into the pipette and that this displacement is associated with the activation of mechanosensitive (MS) channels in the same patch. The membrane displacement, ≈1 μm with each prolonged depolarization, occurs after variable delays ranging from tens of milliseconds to many seconds and is correlated in time with activation of MS channels. Increasing the voltage step shortens both the delay to membrane displacement and the delay to activation. Preventing depolarization-induced membrane displacement by applying positive pressure to the shank of the pipette or by coating the tips of the borosilicate pipettes with soft glass prevents the depolarization-induced activation of MS channels. The correlation between depolarization-induced membrane displacement and activation of MS channels indicates that the membrane displacement is associated with sufficient membrane tension to activate MS channels. Because membrane tension can modulate the activity of various ligand and voltage-activated ion channels as well as some transporters, an apparent voltage dependence of a channel or transporter in a membrane patch in a borosilicate pipette may result from voltage-induced tension rather than from direct modulation by voltage.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Duchenne muscular dystrophy (DMD) is a progressive neuromuscular disease with death usually occurring because of respiratory failure. Signs of early respiratory insufficiency are usually first detectable in sleep. Objective: To study the presentation of sleep-related breathing disorder (SRBD) in patients with DMD. Method:> A retrospective review of patients with DMD attending a tertiary paediatric sleep disorder clinic over a 5-year period. Symptoms, lung function and polysomnographic indices were reviewed. Results: A total of 34 patients with DMD were referred for respiratory assessment (1-15 years). Twenty-two (64%) reported sleep-related symptomatology. Forced vital capacity (FVC) was between 12 and 107% predicted (n = 29). Thirty-two progressed to have polysomnography of which 15 were normal studies (median age: 10 years) and 10 (31%) were diagnostic of obstructive sleep apnoea (OSA) (median age: 8 years). A total of 11 patients (32%) showed hypoventilation (median age: 13 years) during the 5-year period and non-invasive ventilation (NIV) was offered to them. The median FVC of this group was 27% predicted. There was a significant improvement in the apnoea/hypopnoea index (AHI) (mean difference = 11.31, 95% CI = 5.91-16.70, P = 0.001) following the institution of NIV. Conclusions: The prevalence of SRBD in DMD is significant. There is a bimodal presentation of SRBD, with OSA found in the first decade and hypoventilation more commonly seen at the beginning of the second decade. Polysomnography is recommended in children with symptoms of OSA, or at the stage of becoming wheelchair-bound. In patients with the early stages of respiratory failure, assessment with polysomnography-identified sleep hypoventilation and assisted in initiating NIV.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: La ventilation non invasive (VNI) est un outil utilisé en soins intensifs pédiatriques (SIP) pour soutenir la détresse respiratoire aigüe. Un échec survient dans près de 25% des cas et une mauvaise synchronisation patient-ventilateur est un des facteurs impliqués. Le mode de ventilation NAVA (neurally adjusted ventilatory assist) est asservi à la demande ventilatoire du patient. L’objectif de cette étude est d’évaluer la faisabilité et la tolérance des enfants à la VNI NAVA et l’impact de son usage sur la synchronie et la demande respiratoire. Méthode: Étude prospective, physiologique, croisée incluant 13 patients nécessitant une VNI dans les SIP de l’hôpital Ste-Justine entre octobre 2011 et mai 2013. Les patients ont été ventilés successivement en VNI conventionnelle (30 minutes), en VNI NAVA (60 minutes) et en VNI conventionnelle (30 minutes). L’activité électrique du diaphragme (AEdi) et la pression des voies aériennes supérieures ont été enregistrées pour évaluer la synchronie. Résultats: La VNI NAVA est faisable et bien tolérée chez tous les enfants. Un adolescent a demandé l’arrêt précoce de l’étude en raison d’anxiété reliée au masque sans fuite. Les délais inspiratoires et expiratoires étaient significativement plus courts en VNI NAVA comparativement aux périodes de VNI conventionnelle (p< 0.05). Les efforts inefficaces étaient moindres en VNI NAVA (résultats présentés en médiane et interquartiles) : 0% (0 - 0) en VNI NAVA vs 12% (4 - 20) en VNI conventionnelle initiale et 6% (2 - 22) en VNI conventionnelle finale (p< 0.01). Globalement, le temps passé en asynchronie a été réduit à 8% (6 - 10) en VNI NAVA, versus 27% (19 - 56) et 32% (21 - 38) en périodes de VNI conventionnelle initiale et finale, respectivement (p= 0.05). Aucune différence en termes de demande respiratoire n’a été observée. Conclusion: La VNI NAVA est faisable et bien tolérée chez les enfants avec détresse respiratoire aigüe et permet une meilleure synchronisation patient-ventilateur. De plus larges études sont nécessaires pour évaluer l’impact clinique de ces résultats.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: La ventilation non invasive (VNI) est un outil utilisé en soins intensifs pédiatriques (SIP) pour soutenir la détresse respiratoire aigüe. Un échec survient dans près de 25% des cas et une mauvaise synchronisation patient-ventilateur est un des facteurs impliqués. Le mode de ventilation NAVA (neurally adjusted ventilatory assist) est asservi à la demande ventilatoire du patient. L’objectif de cette étude est d’évaluer la faisabilité et la tolérance des enfants à la VNI NAVA et l’impact de son usage sur la synchronie et la demande respiratoire. Méthode: Étude prospective, physiologique, croisée incluant 13 patients nécessitant une VNI dans les SIP de l’hôpital Ste-Justine entre octobre 2011 et mai 2013. Les patients ont été ventilés successivement en VNI conventionnelle (30 minutes), en VNI NAVA (60 minutes) et en VNI conventionnelle (30 minutes). L’activité électrique du diaphragme (AEdi) et la pression des voies aériennes supérieures ont été enregistrées pour évaluer la synchronie. Résultats: La VNI NAVA est faisable et bien tolérée chez tous les enfants. Un adolescent a demandé l’arrêt précoce de l’étude en raison d’anxiété reliée au masque sans fuite. Les délais inspiratoires et expiratoires étaient significativement plus courts en VNI NAVA comparativement aux périodes de VNI conventionnelle (p< 0.05). Les efforts inefficaces étaient moindres en VNI NAVA (résultats présentés en médiane et interquartiles) : 0% (0 - 0) en VNI NAVA vs 12% (4 - 20) en VNI conventionnelle initiale et 6% (2 - 22) en VNI conventionnelle finale (p< 0.01). Globalement, le temps passé en asynchronie a été réduit à 8% (6 - 10) en VNI NAVA, versus 27% (19 - 56) et 32% (21 - 38) en périodes de VNI conventionnelle initiale et finale, respectivement (p= 0.05). Aucune différence en termes de demande respiratoire n’a été observée. Conclusion: La VNI NAVA est faisable et bien tolérée chez les enfants avec détresse respiratoire aigüe et permet une meilleure synchronisation patient-ventilateur. De plus larges études sont nécessaires pour évaluer l’impact clinique de ces résultats.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introducción: El Síndrome de Apnea Hipopnea Obstructiva del Sueño es un trastorno respiratorio del sueño mayor ampliamente conocido, con importantes implicaciones para los pacientes y cuya incidencia ha venido en aumento durante los últimos años; comprende diversas manifestaciones clínicas que varían desde el ronquido hasta consecuencias cardiovasculares importantes. Objetivo: Describir la experiencia de los procedimientos quirúrgicos más utilizados para el tratamiento de pacientes con Trastornos Respiratorios del Sueño en la Clínica Rivas. Diseño: Estudio observacional descriptivo. Métodos: Revisión de 366 historias clínicas de pacientes con diagnóstico clínico y Polisomnográfico de SAHOS intervenidos quirúrgicamente debido al Trastorno Respiratorio del Sueño por rechazo de terapia de presión positiva en 3 años de observación. Resultados: Se evaluaron diferencias en medianas de los cambios del IAH, índice de Saturación de oxigeno basal y mínima, y el índice de microdespertares nocturnos tanto prequirúrgica como postquirúrgicamente. Como medida de evaluación secundaria se evaluaron las complicaciones quirúrgicas. Conclusión: En nuestra institución, como centro de referencia en apnea del sueño, la cirugía ha demostrado que disminuye de forma significativa gravedad del SAHOS y disminuye el riesgo de los pacientes con trastornos respiratorios del sueño que han rechazado el dispositivo de presión positiva.