905 resultados para pitch controller
Resumo:
Using the recently developed model predictive static programming (MPSP) technique, a nonlinear suboptimal reentry guidance scheme is presented in this paper for a reusable launch vehicle (RLV). Unlike traditional RLV guidance, the problem considered over here is restricted only to pitch plane maneuver of the vehicle, which allows simpler mission planning and vehicle load management. The computationally efficient MPSP technique brings in the philosophy of trajectory optimization into the framework of guidance design, which in turn results in very effective guidance schemes in general. In the problem addressed in this paper, it successfully guides the RLV through the critical reentry phase both by constraining it to the allowable narrow flight corridor as well as by meeting the terminal constraints at the end of the reentry segment. The guidance design is validated by considering possible aerodynamic uncertainties as well as dispersions in the initial conditions. (C) 2010 Elsevier Masson SAS. All rights reserved.
Resumo:
Grid connected PWM-VSIs are being increasingly used for applications such as Distributed Generation (DG), power quality, UPS etc. Appropriate control strategies for grid synchronisation and line current regulation are required to establish such a grid interconnection and power transfer. Control of three phase VSIs is widely reported in iterature. Conventionally, dq control in Synchronous Reference Frame(SRF) is employed for both PLL and line current control where PI-controllers are used to track the DC references. Single phase systems do not have defined direct (d) and quadrature (q) axis components that are required for SRF transformation. Thus, references are AC in nature and hence usage of PI controllers cannot yield zero steady state errors. Resonant controllers have the ability to track AC references accurately. In this work, a resonant controller based single phase PLL and current control technique are being employed for tracking grid frequency and the AC current reference respectively. A single phase full bridge converter is being operated as a STATCOM for performance evaluation of the control scheme.
Resumo:
A new design technique for an SVC-based power system damping controller has been proposed. The controller attempts to place all plant poles within a specified region on the s-plane to guarantee the desired closed loop performance. The use of Horowitz's quantitative feedback theory (QFT) permits the design of a 'fixed gain controller' that maintains its performance in spite of large variations in the plant parameters during its normal course of operation. The required controller parameters are arrived at by solving an optimization problem that incorporates the control specifications. The performance of this robust controller has been evaluated on a single machine infinite bus system equipped with a mid point SVC, and the results are shown to be consistent with the expected performance of the stabilizer. (C) 1998 Elsevier Science S.A. All rights reserved.
Resumo:
This paper proposes a sensorless vector control scheme for general-purpose induction motor drives using the current error space phasor-based hysteresis controller. In this paper, a new technique for sensorless operation is developed to estimate rotor voltage and hence rotor flux position using the stator current error during zero-voltage space vectors. It gives a comparable performance with the vector control drive using sensors especially at a very low speed of operation (less than 1 Hz). Since no voltage sensing is made, the dead-time effect and loss of accuracy in voltage sensing at low speed are avoided here, with the inherent advantages of the current error space phasor-based hysteresis controller. However, appropriate device on-state drops are compensated to achieve a steady-state operation up to less than 1 Hz. Moreover, using a parabolic boundary for current error, the switching frequency of the inverter can be maintained constant for the entire operating speed range. Simple sigma L-s estimation is proposed, and the parameter sensitivity of the control scheme to changes in stator resistance, R-s is also investigated in this paper. Extensive experimental results are shown at speeds less than 1 Hz to verify the proposed concept. The same control scheme is further extended from less than 1 Hz to rated 50 Hz six-step operation of the inverter. Here, the magnetic saturation is ignored in the control scheme.
Resumo:
FACTS controllers are emerging as viable and economic solutions to the problems of large interconnected ne networks, which can endanger the system security. These devices are characterized by their fast response, absence of inertia, and minimum maintenance requirements. Thyristor controlled equipment like Thyristor Controlled Series Capacitor (TCSC), Static Var Compensator (SVC), Thyristor Controlled Phase angle Regulator (TCPR) etc. which involve passive elements result in devices of large sizes with substantial cost and significant labour for installation. An all solid-state device using GTOs leads to reduction in equipment size and has improved performance. The Unified Power Flow Controller (UPFC) is a versatile controller which can be used to control the active and reactive power in the Line independently. The concept of UPFC makes it possible to handle practically all power flow control and transmission line compensation problems, using solid-state controllers, which provide functional flexibility, generally not attainable by conventional thyristor controlled systems. In this paper, we present the development of a control scheme for the series injected voltage of the UPFC to damp the power oscillations and improve transient stability in a power system. (C) 1998 Elsevier Science Ltd. All rights reserved.
Resumo:
The authors describe the constructional features of a controller for operating an autonomous refrigeration unit powered by a field of photovoltaic panels and backed up by a generator set. The controller enables three voltage levels of operation of an inverter to meet the start, run and off cycle conditions of the refrigerator compressor. The algorithm considers several input and output parameters and status signals from each subsystem of the unit to deduce a control strategy. Such units find application for storage of vaccines and life-saving medicines requiring uninterrupted refrigeration, in medical shops, rural health centres, veterinary laboratories etc.
Resumo:
Dynamics of the aircraft configuration considered in this paper show a unique characteristic in that there are no stable attractors in the entire high angle-of-attack flight envelope. As a result, once the aircraft has departed from the normal flight regime, no standard technique can be applied to recover the aircraft. In this paper, using feedback linearization technique, a nonlinear controller is designed at high angles of attack, which is engaged after the aircraft departs from normal flight regime. This controller stabilizes the aircraft into a stable spin. Then a set of synthetic pilot inputs is applied to cause an automatic transition from the spin equilibrium to low angles of attack where the second controller is connected. This controller is a normal gain-scheduled controller designed to have a large domain of attraction at low angles of attack. It traps the aircraft into a low angle-of-attack level flight. This entire concept of recovery has been verified using six-degrees-of-freedom nonlinear simulation. Feedback linearization technique used to design a controller ensures internal stability only if the nonlinear plant has stable zero dynamics. Because zero dynamics depend on the selection of outputs, a new method of choosing outputs is described to obtain a plant that has stable zero dynamics. Certain important aspects pertaining to the implementation of a feedback linearization-based controller are also discussed.
Resumo:
This paper proposes a simple current error space vector based hysteresis controller for two-level inverter fed Induction Motor (IM) drives. This proposed hysteresis controller retains all advantages of conventional current error space vector based hysteresis controllers like fast dynamic response, simple to implement, adjacent voltage vector switching etc. The additional advantage of this proposed hysteresis controller is that it gives a phase voltage frequency spectrum exactly similar to that of a constant switching frequency space vector pulse width modulated (SVPWM) inverter. In this proposed hysteresis controller the boundary is computed online using estimated stator voltages along alpha and beta axes thus completely eliminating look up tables used for obtaining parabolic hysteresis boundary proposed in. The estimation of stator voltage is carried out using current errors along alpha and beta axes and steady state model of induction motor. The proposed scheme is simple and capable of taking inverter upto six step mode operation, if demanded by drive system. The proposed hysteresis controller based inverter fed drive scheme is simulated extensively using SIMULINK toolbox of MATLAB for steady state and transient performance. The experimental verification for steady state performance of the proposed scheme is carried out on a 3.7kW IM.
Resumo:
In this paper analytical expressions for optimal Vdd and Vth to minimize energy for a given speed constraint are derived. These expressions are based on the EKV model for transistors and are valid in both strong inversion and sub threshold regions. The effect of gate leakage on the optimal Vdd and Vth is analyzed. A new gradient based algorithm for controlling Vdd and Vth based on delay and power monitoring results is proposed. A Vdd-Vth controller which uses the algorithm to dynamically control the supply and threshold voltage of a representative logic block (sum of absolute difference computation of an MPEG decoder) is designed. Simulation results using 65 nm predictive technology models are given.
Resumo:
A current error space phasor based simple hysteresis controller is proposed in this paper to control the switching frequency variation in two-level pulsewidth-modulation (PWM) inverter-fed induction motor (IM) drives. A parabolic boundary for the current error space phasor is suggested for the first time to obtain the switching frequency spectrum for output voltage with hysteresis controller similar to the constant switching frequency voltage-controlled space vector PWM-based IM drive. A novel concept of online variation of this parabolic boundary, which depends on the operating speed of motor, is presented. A generalized technique that determines the set of unique parabolic boundaries for a two-level inverter feeding any given induction motor is described. The sector change logic is self-adaptive and is capable of taking the drive up to the six-step mode if needed. Steady-state and transient performance of proposed controller is experimentally verified on a 3.7-kW IM drive in the entire speed range. Close resemblance of the simulation and experimental results is shown.
Resumo:
We present an extrema based unwarping technique for signals with time-varying periodicity. We show that for arbitrary variation of pitch periodicity in speech signal,the unwarping technique maps the signals to periodic signals which enable eficient estimation of periodicity. We demonstrate the e�ectiveness of the new technique using both synthetic and real speech signals.