944 resultados para optimization of the fracture parameters
Resumo:
Haematological parameters as erythrocytes, leukocytes and plasma glucose in Piaractus mesopotamicus Holmberg, 1887 were analyzed. Fish were parasitized with Argulus sp. (Crustacea, Branchiura) and treated with 0.4 mg of thriclorphon 500/L water. The effects of parasitism and the action of the treatment were evaluated. Parasitized fish showed greater number of monocytes (P>0.05) and special granulocitic cells (P<0.01) in the peripheric blood than the unparasitized (control) fish. Parasitized fish showed lower number of thrombocytes (P>0.05). Organophosphate treatment presented significantly reduction (P>0.05) in red blood cells (RBC) and hemoglobin.
Resumo:
Cephalosporin C production process optimization was studied based on four experiments carried out in an agitated and aerated tank fermenter operated as a fed-batch reactor. The microorganism Cephalosporium acremonium ATCC 48272 (C-10) was cultivated in a synthetic medium containing glucose as major carbon and energy source. The additional medium contained a hydrolyzed sucrose solution as the main carbon and energy source and it was added after the glucose depletion. By manipulating the supplementary feed rate, it was possible to increase antibiotic production. A mathematical model to represent the fed-batch production process was developed. It was observed that the model was applicable under different operation conditions, showing that optimization studies can be made based on this model. (C) 1999 Elsevier B.V. Ltd. All rights reserved.
Resumo:
Waste frying oil has been used to optimize the production of biodiesel. Biodiesel was prepared through sodium ethoxide catalyzed methanolysis from the transesterification of recycled waste frying oil. Optimization of the transesterification reaction for biodiesel production was carried out by means of statistical analyses using ANOVA. The optimum conditions for reaction were the following: a oil methanol mole ratio of 1:9, temperature of 50 degrees C, catalyst mass fraction of 0.9 %, and reaction time of 40 min, which enabled a yield of 98.7 % determined by gas chromatography/mass spectrometry (GC/MS) analysis. The density and viscosity of biodiesel/diesel blends have been determined as a function of composition at several temperatures.
Resumo:
A simplified procedure for the preparation of immobilized beta-amylase using non-purified extract from fresh sweet potato tubers is established in this paper, using differently activated agarose supports. Beta-amylase glutaraldehyde derivative was the preparation with best features, presenting improved temperature and pH stability and activity. The possibility of reusing the amylase was also shown, when this immobilized enzyme was fully active for five cycles of use. However, immobilization decreased enzyme activity to around 15%. This seems to be mainly due to diffusion limitations of the starch inside the pores of the biocatalyst particles. A fifteen-fold increase in the Km was noticed, while the decrease of Vmax was only 30% (10.1 U mg-1 protein and 7.03 U mg-1 protein for free and immobilized preparations, respectively). © 2013 Elsevier Ltd.
Resumo:
The sampling scheme is essential in the investigation of the spatial variability of soil properties in Soil Science studies. The high costs of sampling schemes optimized with additional sampling points for each physical and chemical soil property, prevent their use in precision agriculture. The purpose of this study was to obtain an optimal sampling scheme for physical and chemical property sets and investigate its effect on the quality of soil sampling. Soil was sampled on a 42-ha area, with 206 geo-referenced points arranged in a regular grid spaced 50 m from each other, in a depth range of 0.00-0.20 m. In order to obtain an optimal sampling scheme for every physical and chemical property, a sample grid, a medium-scale variogram and the extended Spatial Simulated Annealing (SSA) method were used to minimize kriging variance. The optimization procedure was validated by constructing maps of relative improvement comparing the sample configuration before and after the process. A greater concentration of recommended points in specific areas (NW-SE direction) was observed, which also reflects a greater estimate variance at these locations. The addition of optimal samples, for specific regions, increased the accuracy up to 2 % for chemical and 1 % for physical properties. The use of a sample grid and medium-scale variogram, as previous information for the conception of additional sampling schemes, was very promising to determine the locations of these additional points for all physical and chemical soil properties, enhancing the accuracy of kriging estimates of the physical-chemical properties.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective To assess the diagnostic accuracy of the surface electromyography (sEMG) parameters associated with referred anterior knee pain in diagnosing patellofemoral pain syndrome (PFPS). Design Sensitivity and specificity analysis. Setting Physical rehabilitation center and laboratory of biomechanics and motor control. Participants Pain-free subjects (n=29) and participants with PFPS (n=22) selected by convenience. Interventions Not applicable. Main Outcome Measure The diagnostic accuracy was calculated for sEMG parameters’ reliability, precision, and ability to differentiate participants with and without PFPS. The selected sEMG parameter associated with anterior knee pain was considered as an index test and was compared with the reference standard for the diagnosis of PFPS. Intraclass correlation coefficient, SEM, independent t tests, sensitivity, specificity, negative and positive likelihood ratios, and negative and positive predictive values were used for the statistical analysis. Results The medium-frequency band (B2) parameter was reliable (intraclass correlation coefficient=.80–.90), precise (SEM=2.71–3.87 normalized unit), and able to differentiate participants with and without PFPS (P<.05). The association of B2 with anterior knee pain showed positive diagnostic accuracy values (specificity, .87; sensitivity, .70; negative likelihood ratio, .33; positive likelihood ratio, 5.63; negative predictive value, .72; and positive predictive value, .86). Conclusions The results provide evidence to support the use of EMG signals (B2 – frequency band of 45–96Hz) of the vastus lateralis and vastus medialis muscles with referred anterior knee pain in the diagnosis of PFPS.
Resumo:
The influence of deposition parameters, namely polymer concentration and pH of the deposition solution, cleaning, and drying steps on the morphology and electrical characteristics of polyaniline and sulfonated polystyrene (PANI/PSS) nanostructured films deposited by the self-assembly technique is evaluated by UV-Vis spectroscopy, optical and atomic force microscopy, and electrical resistance measurements. It is found that stirring the cleaning solution during the cleaning step is crucial for obtaining homogenous films. Stirring of the cleaning solution also influences the amount of PANI adsorbed in the films. In this regard, the drying process seems to be less critical since PANI amount and film thickness are similar in films dried with N-2 flow or with an absorbent tissue. It is observed, however, that drying with N-2 flow results in rougher films. As an additional point, an assessment of the influence of the deposition method (manual versus mechanical) on the film characteristics was carried out. A significant difference on the amount of PANI and film thickness between films prepared by different human operators and by a homemade mechanical device was observed. The variability in film thickness and PANI adsorbed amount is smaller in films mechanically assembled. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
A multiwall carbon nanotube/silicone rubber (MWCNT/SR) composite electrode has been used for the determination of hydrochlorothiazide (HCTZ) in pharmaceutical formulations by differential pulse voltammetry (DPV). The electro-oxidation process was evaluated by cyclic voltammetry, from which it was observed that HCTZ presents an irreversible oxidation peak at 0.82 V vs. saturated calomel electrode (SCE) in the potential range from 0.5 to 1.1 V, in Britton-Robinson buffer pH 7.0 at MWCNT/SR. HCTZ was determined by DPV using a MWCNT/SR 70% (MWCNT, m/m) composite electrode after the optimization of the experimental parameters. The linear range was from 5.0 to 70.0 mu mol L-1, with a limit of detection (LOD) of 2.6 mu mol L-1. The HCTZ was determined in pharmaceutical formulations using the proposed composite electrode and the results agreed with those from the official high performance liquid chromatography (HPLC) method within 95% confidence level, according to the t-Student test.
Resumo:
The aim of this study was to assess the ability to extract surgically relevant information from plain radiographs in trimalleolar fractures and to compare this with the information gathered from computed tomography (CT).