994 resultados para natural water


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Welland Power and Supply Canal Company Limited, established in 1893 and incorporated in 1894 with a capital stock of $500,000. The aim of the company was to harness the natural water supply of the Niagara and Welland Rivers. In 1898 the Canadian Electrical News published a report by Henry Symons, QC outlining the main project of the company. This project involves the construction of a canal from the Welland River to the brow of the mountain at Thorold, a distance of 8 miles; the construction at Thorold of a power house, and from Thorold to Lake Ontario, a raceway by which to carry water into the lake. The estimate for the machinery to generate 100,000 horse power is £125,000; for transmission line to Toronto at a voltage of 10,000….The total estimate therefore amounts to £2,452,162, or roughly speaking, $12,000,000. Source: Canadian Electrical News, August 1898, p. 172. In 1899 the company officers petitioned the federal government desiring a name change to the Niagara-Welland Power Company Limited. Officers of the company were Harry Symons, President; Charles A. Hesson, Vice-President; and M.R. O’Loughlin, James B. Sheehan, James S. Haydon, Frederick K. Foster, directors; John S. Campbell, secretary-treasurer. The company’s head offices were located in St. Catharines, with a New York (City) office on Broad Street. In 1905 and 1909 the company petitioned the federal government for additional time to construct its works, which was granted. The company had until May 16, 1915 to complete construction. John S. Campbell (1860-1950) was a graduate of the University of Toronto and Osgoode Hall. During his university years John began his military career first in "K" Company, Queens Own rifles and then later as Commanding Officer of the 19th Lincoln Regiment, from 1906 to 1910. Upon his return to St. Catharines John Campbell served as secretary in the St. Catharines Garrison Club, a social club for military men begun in 1899. After being called to the Bar, he became a partner in the firm of Campbell and McCarron and was appointed to the bench in 1916, serving until retirement in 1934. Judge Campbell served as an alderman for several terms and was the mayor of St. Catharines in 1908 and 1909. He also served as the first chairman of the St. Catharines Public Utilities in 1914. John S. Campbell was married to Elizabeth Oille, daughter of Jerome B. and Charlotte (St. John) Oille. The family home "Cruachan" was located at 32 Church St.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Les thiols à faible masse moléculaire (FMM) peuvent affecter la biodisponibilité du mercure et mener à une plus grande production de méthylmercure par les microorganismes méthylants. Les résultats d’une étude réalisée au sein de la matrice extracellulaire du périphyton de la zone littorale d’un lac des Laurentides ont démontré que les concentrations en thiols à FMM retrouvées dans cette matrice sont jusqu’à 1000 fois supérieures à celles de la colonne d’eau avoisinante. Ces thiols sont significativement corrélés à la chlorophylle a du périphyton, suggérant une production par les algues. Le mercure de la matrice extracellulaire, plus spécifiquement dans la fraction colloïdale mobile, est aussi corrélé aux thiols d’origine algale. Ces résultats suggèrent qu’une accumulation de thiols s’opère dans l’espace extracellulaire du périphyton et qu’ils peuvent favoriser le transfert du mercure vers les microorganismes produisant le méthylmercure. Les résultats d’une seconde étude menée sur les méthodes de préservation d’échantillons d’eau pour la conservation des thiols à FMM ont démontré que la température optimale d’entreposage était de -80 °C et que la lyophilisation menait à une sous-estimation des concentrations mesurées. Les taux de dégradation étaient plus rapides lors de la conservation à -20 °C et variables selon la chimie de l’eau utilisée et les espèces de thiols observées. Suivant ces résultats, nous proposons un cadre de recherche pour de futures études sur la spéciation du mercure dans le périphyton et nous suggérons des précautions lors de la manipulation et de la conservation des thiols à FMM d’échantillons naturels.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Se presenta la implementación del modelo hidrológico distribuido de Témez sobre GRASS GIS. Este modelo se utiliza para la evaluación de recursos hídricos en régimen natural con paso mensual y para la totalidad del territorio español, tal como aparece en el Libro Blanco del Agua en España. A partir de las variables de entrada, precipitación y evapotranspiración potencial y los parámetros hidrológicos, el modelo obtiene los mapas de los distintos almacenamientos, humedad en el suelo y volumen de acuífero, y de las variables de salida del ciclo hidrológico, evapotranspiración y escorrentía total, obtenida esta última como suma de la escorrentía superficial y subterránea. El objetivo final del trabajo es la implementación de los componentes superficiales y subterráneos en el modelo hidrológico, desarrollando para ello un programa que hace funcional en GRASS GIS el modelo matemático en que se basa la evaluación de recursos hídricos

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the absence of a suitable method for routine analysis of large numbers of natural river water samples for organic nitrogen and phosphorus fractions, a new simultaneous digestion technique was developed, based on a standard persulphate digestion procedure. This allows rapid analysis of river, lake and groundwater samples from a range of environments for total nitrogen and phosphorus. The method was evaluated using a range of organic nitrogen and phosphorus structures tested at low, mid and high range concentrations from 2 to 50 mg l-1 nitrogen and 0.2 to 10 mg l-1 phosphorus. Mean recoveries for nitrogen ranged from 94.5% (2 mg I-1) to 92.7% (50 mg I-1) and for phosphorus were 98.2% (0.2 mg l-1) to 100.2% (10 mg l-1). The method is precise in its ability m reproduce results from replicate digestions, and robust in its ability to handle a variety of natural water samples in the pH range 5-8.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aims: To determine the prevalence and expression of metallo-beta-lactamases (MBL)-encoding genes in Aeromonas species recovered from natural water reservoirs in southeastern Brazil. Methods and Results: Eighty-seven Aeromonas isolates belonging to Aeromonas hydrophila (n = 41) and Aer. jandaei (n = 46) species were tested for MBL production by the combined disk test using imipenem and meropenem disks as substrates and EDTA or thioglycolic acid as inhibitors. The presence of MBL genes was investigated by PCR and sequencing using new consensus primer pairs designed in this study. The cphA gene was found in 97.6% and 100% of Aer. hydrophila and Aer. jandaei isolates, respectively, whereas the acquired MBL genes bla(IMP), bla(VIM) and bla(SPM-1) were not detected. On the other hand, production of MBL activity was detectable in 87.8% and 10.9% of the cphA-positive Aer. hydrophila and Aer. jandaei isolates respectively. Conclusions: Our results indicate that cphA seems to be intrinsic in the environmental isolates of Aer. hydrophila and Aer. jandaei in southeastern Brazil, although, based on the combined disk test, not all of them are apparently able to express the enzymatic activity. Significance and Impact of the Study: These data confirm the presence of MBL-producing Aeromonas species in natural water reservoirs. Risk of water-borne diseases owing to domestic and industrial uses of freshwater should be re-examined from the increase of bacterial resistance point of view.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Langmuir-Blodgett (LB) and layer-by-layer films (LbL) of a PPV (p-phenylenevinylene) derivative, an azo compound and tetrasulfonated phthalocyanines were successfully employed as transducers in an ""electronic tongue"" system for detecting trace levels of phenolic compounds in water. The choice of the materials was based on their distinct electrical natures, which enabled the array to establish a fingerprint of very similar liquids. Impedance spectroscopy measurements were taken in the frequency range from 10 Hz to 1 MHz, with the data analysed with principal component analysis (PCA). The sensing units were obtained from five-layer LB films of (poly[(2-methoxy-5-n-hexyloxy)-p-phenylenevinylene]), OC(1)OC(18)-PPV (poly(2-methoxy,5-(n-octadecyl)-p-phenylenevinylene)), DR (HEMA-co-DR13MA (poly-(hydroxyethylmethacrylate-co-[4`-[[2-(methacryloyloxy)-ethyl]ethylamino]-2-chloro-4-nitroazobenzene]))) and five-bilayer LbL films of tetrasulfonated metallic phthalocyanines deposited onto gold interdigitated electrodes. The sensors were immersed into phenol, 2-chloro-4-methoxyphenol, 2-chlorophenol and 3-chlorophenol (isomers) solutions at 1 x 10(-9) mol L(-1), with control experiments carried out in ultra pure water. Samples could be distinguished if the principal component analysis (PCA) plots were made with capacitance values taken at 10(3) Hz, which is promising for detection of trace amounts of phenolic pollutants in natural water.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The performance of a carbon paste electrode (CPE) modified with SBA-15 nanostructured silica organofunctionalised with 2-benzothiazolethiol in the simultaneous determination of Pb(II), Cu(II) and Hg(II) ions in natural water and sugar cane spirit (cachaca) is described. Pb(II), Cu(II) and Hg(II) were pre-concentrated on the surface of the modified electrode by complexing with 2-benzothiazolethiol and reduced at a negative potential (-0.80 V). Then the reduced products were oxidised by DPASV procedure. The fact that three stripping peaks appeared on the voltammograms at the potentials of -0.48 V (Pb2+), -0.03 V (Cu2+) and +0.36 V (Hg2+) in relation to the SCE, demonstrates the possibility of simultaneous determination of Pb2+, Cu2+ and Hg2+. The best results were obtained under the following optimised conditions: 100 mV pulse amplitude, 3 min accumulation time, 25 mV s(-1) scan rate in phosphate solution pH 3.0. Using such parameters, calibration graphs were linear in the concentration ranges of 3.00-70.0 x 10(-7) mol L-1 (Pb2+), 8.00-100.0 X 10(-7) mol L-1 (Cu2+) and 2.00-10.0 x 10(-6) mol L-1 (Hg2+). Detection limits of 4.0 x 10(-8) mol L-1 (Pb2+), 2.0 x 10(-7) mol L-1 (Cu2+) and 4.0 x 10(-7) mol L-1 (Hg2+) were obtained at the signal noise ratio (SNR) of 3. The results indicate that this electrode is sensitive and effective for simultaneous determination of Pb2+, Cu2+ and Hg2+ in the analysed samples. (C) 2008 Published by Elsevier B.V.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes the use of a dental amalgam electrode (DAE) to evaluate the electrochemical behaviour and to develop an electroanalytical procedure for determination of diquat herbicide in natural water and potato samples. The work was based on the square wave voltammetry responses of diquat, which presented two well-defined and reversible reduction peaks, at -0.56 V (peak 1) and -1.00V (peak 2). The experimental and voltammetric parameters were optimised, and the analytical curves were constructed and compared to similar curves performed by high performance liquid chromatography coupled to ultraviolet-visible spectrophotometric detector (HPLC/UV-vis). The responses were directly proportional to diquat concentration in a large interval of concentration, and the calculated detection limits were very similar, around 10 mu g L(-1) (10 ppb) for voltammetric and chromatographic experiments. These values were lower than the maximum residue limit established for natural water by the Brazilian Environmental Agency. The recovery percentages in pure electrolyte, natural water and potato samples showed values from 70% to 130%, demonstrating that the voltammetric methodology proposed is suitable for determining any contamination by diquat in different samples, minimising the toxic residues due to the use of liquid mercury or the adsorptive process relative to use of other solid surfaces. (C) 2009 Published by Elsevier B.V.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The development and application of a functionalized carbon nanotubes paste electrode (CNPE) modified with crosslinked chitosan for determination of Cu(II) in industrial wastewater, natural water and human urine samples by linear scan anodic stripping voltammetry (LSASV) are described. Different electrodes were constructed using chitosan and chitosan crosslinked with glutaraldehyde (CTS-GA) and epichlorohydrin (CTS-ECH). The best voltammetric response for Cu(II) was obtained with a paste composition of 65% (m/m) of functionalized carbon nanotubes, 15% (m/m) of CTS-ECH, and 20% (m/m) of mineral oil using a solution of 0.05 mol L(-1) KNO(3) with pH adjusted to 2.25 with HNO(3), an accumulation potential of 0.3V vs. Ag/AgCl (3.0 mol L(-1) KCl) for 300 s and a scan rate of 100 mV s(-1). Under these optimal experimental conditions, the voltammetric response was linearly dependent on the Cu(II) concentration in the range from 7.90 x 10(-8) to 1.60 x 10(-5) mol L(-1) with a detection limit of 1.00 x 10(-8) mol L(-1). The samples analyses were evaluated using the proposed sensor and a good recovery of Cu(II) was obtained with results in the range from 98.0% to 104%. The analysis of industrial wastewater, natural water and human urine samples obtained using the proposed CNPE modified with CTS-ECH electrode and those obtained using a comparative method are in agreement at the 95% confidence level. (C) 2009 Elsevier B. V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Modern societies rely on natural water pathways that include subsurface flow of water and dissolved chemicals. The thesis presents a range of numerical and analytical models for simulating physical, chemical and biological processes in the subsurface, including coastal aquifers, the near-surface vadose zone, and solute transport in biogeochemically active aquifers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Neste trabalho é avaliada a aplicação da técnica de ICP OES (Espectrometria de Emissão com Plasma Indutivamente Acoplado) para a determinação de elementos traço em amostras ambientais. Foram investigados os comportamentos de As, Ba, Cd, Co, Cu, Cr, Mn, Ni, Pb, V e Zn, utilizando-se espectrômetro com vista de observação axial/radial do plasma e sistema de detecção baseado em dispositivos de carga acoplada (CCD). No presente estudo, foi avaliado o desempenho dos nebulizadores pneumáticos do tipo concêntrico (Meinhard), “cross flow” e GemCone® acoplados às câmaras de nebulização de duplo passo (Scott) e ciclônica, bem como do nebulizador ultra-sônico para a introdução de amostras no plasma. Investigou-se a robustez do plasma, potência de radiofreqüência (RF), vazão dos gases de nebulização e auxiliar, bem como a altura de observação, para ambas as vistas de observação do plasma. Sob condições otimizadas os limites de detecção (LD), em ng mL-1, para os elementos As, Ba, Cd, Co, Cr, Cu, Mn, Ni, Pb, V e Zn, em solução aquosa de HNO3 5% (v/v), utilizando-se a configuração axial do plasma, foram: 1,1 - 16; 0,002 - 0,32; 0,03 - 1,2; 0,02 - 0,72; 0,03 - 0,82; 0,04 - 3,0; 0,003 - 0,76; 0,08 - 3,8; 0,22 - 8,9; 0,04 - 2,6; e 0,02 - 1,2 respectivamente. Utilizando-se a configuração radial, os LDs (ng mL-1) dos mesmos elementos foram: 10 - 87; 0,01 - 0,91; 0,07 - 3,8; 0,16 - 4,3; 0,13 - 8,1; 0,16 - 4,3; 0,01 - 0,81; 0,43 - 7,6; 1,4 - 37; 0,28 - 6,0 e 0,77 - 9,5 respectivamente. Com relação à nebulização pneumática, os LDs são relativamente mais baixos quando é utilizado o nebulizador concêntrico acoplado à câmara de nebulização ciclônica. LDs ainda melhores são obtidos mediante o uso de nebulização ultra-sônica mas, neste caso, foi observado que o plasma é menos robusto. As metodologias foram desenvolvidas mediante o uso de materiais de referência certificados sendo analisados os seguintes materiais: sedimento marinho (PACS-2/NRCC), folhas de maçã (apple leaves – 1515/NIST) e água (natural water – 1640/NIST), obtendo-se concentrações concordantes com as certificadas, com exceção do Ni em folha de maçã, que não foi detectado utilizando-se a nebulização pneumática e também não pôde ser determinado com exatidão mediante o uso de nebulizador ultra-sônico. Interferências não espectrais observadas na análise de sedimento marinho foram contornadas através da diluição da amostra, ou através da lavagem da câmara de nebulização com solução de HNO3 5% (v/v), por 60 s entre cada ciclo de leitura. Estas interferências não puderam ser contornadas com o uso de padrão interno (PI). A interferência espectral do As sobre o Cd não foi observada fazendo-se a medição do sinal em área de pico, demarcado com somente 3 pontos/pico. Após serem estabelecidas as metodologias de análise, foram analisadas as seguintes amostras não certificadas: água de rio, água subterrânea (poço artesiano), água tratada e de chuva, folhas de eucalipto e bambu, acículas de pinus e infusão de chá preto, sendo possível quantificar baixas concentrações dos elementos investigados, utilizando-se a calibração externa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work describes the synthesis and characterization of 2-aminothiazole modified silica gel (SiAT) and the studies of adsorption and pre-concentration (in batch and using a flow-injection system coupled with optical emission spectrometer) of Cd(II), Cu(II) and Ni(II) in aqueous medium. The adsorption capacity for each metal ions in mmolg(-1) was: Cu(II) = 1.18, Ni(II) = 1.15 and Cd(II) = 1.10. The results obtained in the flow experiments showed about 100% of recovering of the metal ions adsorbed in a mini-column packed with 100 mg of SiAT, using 100 mu L of 2.0 mol L-1 HCl solution as eluent. The quantitative sorption-desorption of the metal ions made possible the application of a flow-injection system in the pre-concentration and quantification by ICP-OES of metal ions at trace level in natural water samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The application of disk shaped gold ultramicroelectrode for nitrite determination with and without addition of supporting electrolyte was studied using the differential pulse voltammetric method. The well-defined peak for nitrite oxidation near 0.8V (vs. Ag/AgCl reference electrode) was used to obtain analytical plots in the concentration range from 0.1 to 0.6 mmol L-1 and from 10.0 to 50.0 mu mol.L-1. The calculated detection limit was 0.65 mu mol.L-1 in purified water, in the absence of supporting electrolyte, with relative standard deviation of 1.36% (n=6) for analyzing 10.0 mu mol L-1 nitrite solutions, and accuracy of 100.9 %, based on recovery studies. The application of this analytical method to mineral and river water samples of natural pH also showed improved sensitivity when compared with the linear sweep voltammetric method previously reported.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, a preconcentration and separation system based on continuous flow hydride generation is proposed to improve the determination of As and Se by total reflection X-ray fluorescence spectrometry. The generated hydrides are continuously separated from the liquid phase and collected in a chamber containing 250 mul of HCI/HNO3 1:1 (v/v) solution. Hydride generation conditions and collection of the hydrides were evaluated. Under optimised conditions, enrichment factors of 55 for As and 82 for Se were attained. Detection limits of 0.3 mug l(-1) for As and Se were obtained when 20 ml of sample was used. Analysis of a natural water standard reference material from National Institute of Standard and Technology (SRM-1640) was in agreement with the certified values at the 95% confidence level. (C) 2004 Elsevier B.V. All rights reserved.