181 resultados para microelectrodes
Resumo:
Three couples of reversible redox waves of the SiW12O404- anion which are composed of two one-electron and one two-electron processes occur in the potential range +0.1 to -0.7 V in aqueous solutions. The first (most positive) and third (most negative) redox waves exhibit good electrocatalytic activities for nitrite reduction in acid solutions with pH < 2 for the former and with pH similar or equal to 4 for the latter. The behavior of the third catalytic wave, which is quite unusual, was studied in detail. The rate constant governing the reduction of NO2- by the first wave of SiW12O404- was measured by an ultramicrodisk electrode as 3.73 x 10(3) M(-1) s(-1).
Resumo:
In this paper, the electrochemical behaviour of molibdosilicic heteropoly complex with dysprosium K10H3[Dy(SiMo11O39)(2)]. xH(2)O [denoted as Dy(SiMo11)(2)] was studied. Voltammetric behavior of this complex was greatly influenced by pH of solutions. The polypyrrole (PPy) film doped with this complex was prepared by electropolymerization of pyrrole in the presence of Dy(SiMo11)(2) under potential cycling conditions. The microenvironment within the PPy film has an effect on the electrochemical behavior of Dy(SiMo11)(2) entrapped in the film. The film electrode can catalyze the reduction of ClO3- and BrO3-.
Resumo:
A new type of macro-micro-macro triple electrode has been fabricated, the steady-state currents of solution redox species have been observed at an ultramicroband electrode by linear potential scan voltammetry, and generation/collection experiments have al
Resumo:
A novel device of multiple cylinder microelectrodes coupled with a parallel planar electrode was proposed. The feedback diffusion current at this device was studied using bilinear transformation of coordinates in the diffusion space, where lines of mass flux and equiconcentration are represented by orthogonal circular functions. The derived expression for the steady-state current shows that as the gap between cylindrical microelectrodes and planar electrode diminishes, greatly enhanced currents can be obtained with high signal-to-noise ratio. Other important geometrical parameters such as distance between adjacent microcylinders, cylinder radius, and number of microcylinders were also discussed in detail.
Resumo:
This paper describes the electrochemical oxidation and reduction of electroactive solutes which are dissolved in and diffusing through the polymer electrolyte solvent, poly(ethylene oxide) (PEO). The characteristics of electrochemical reactions in polymeric solutions are discussed, including how rigid solvent environments affect mass transport rates, and the transport phenomenon of electroactive species in PEO with bathing gases is explained by using the voltammetric theory of ultramicroelectrodes. The possibility that the microelectrode coated with PEO film can be used as a gas sensor has been discussed.
Resumo:
A multi-cylinder microelectrode coupled with a conventional glassy carbon disc electrode (MCM/GC) was prepared and characterized using cyclic voltammetry and chronoamperometry. It was demonstrated that in the same way as one observed a steady-state current at closely spaced microelectrodes when redox recycling takes place, the same effect can be obtained with the MCM/GC device. The experimental results obtained with K3Fe(CN)6 solutions were compared with a previously developed theory. Further, it was demonstrated that with a carbon fibre MCM/GC device, the voltammetric behaviour of dopamine is greatly improved by virtue of redox recycling, hence giving high sensitivity. The steady-state collection current was linearly related to dopamine concentration in the range 1 X 10(-4) to 5 x 10(-7) Mol l-1, and the detection limit was 2 x 10(-7) mol l-1. The influence of coexisting ascorbic acid was also investigated. This device was applied successfully in the determination of dopamine hydrochloride in pharmaceutical preparations.
Resumo:
Electrodes modified with isopolymolybdic acid+polyaniline film, which exhibit high stability and activity in aqueous acidic solution, have been prepared successfully using two methods: one-step synthesis by electrochemical polymerization at a constant applied potential of +0.80 V/SCE or by cycling the potential at 100 mV/s between -0.12 and +0.85 V in 0.5 M H2SO4 containing 5.0x10(-2) M aniline and 5.0x10(-3) M H4Mo8O26, or two-step synthesis by doping the polyaniline film electrode with isopoly acid (IPA) under a cycling potential between -0.20 and +0.40 V in 0.5 M H2SO4 containing the H4Mo8O26 dopant. The thickness of the film and the amount of dopant in the polyaniline film can be controlled by experimental parameters such as the charge, time and the ratio of aniline to IPA in the solution. The experimental results show that electrodes modified with isopolymolybdic acid+polyaniline film using both methods have a strong catalytic effect on the reduction of chlorate anions. Comparison of the two methods of modification shows that the catalytic effect at the modified electrode prepared by the two-step method is greater than that at the electrode prepared by the one-step method.
Resumo:
The analytical expressions of quasi-first and second order homogeneous catalytic reactions with different diffusion coefficients at ultramicrodisk electrodes under steady state conditions are obtained by using the reaction layer concept. The method of treatment is simple and its physical meaning is clear. The relationship between the diffusion layer, reaction layer, the electrode dimension and the kinetic rate constant at an ultramicroelectrode is discussed and the factor effect on the reaction order is described. The order of a catalytic reaction at an ultramicroelectrode under steady state conditions is related not only to C(Z)*/C(O)* but also to the kinetic rate constant and the dimension of the ultramicroelectrode; thus the order of reaction can be controlled by the dimension of the ultramicroelectrode. The steady state voltammetry of the ultramicroelectrode is one of the most simple methods available to study the kinetics of fast catalytic reactions.
Resumo:
The conditions for quasi-first and second order homogeneous catalytic reactions and their variation with each other at an ultramicrodisk electrode in the steady state are discussed in this paper. The order of reaction can be controlled by changing the dimension of the ultramicroelectrode: the second order reaction can be changed to quasi-first by decreasing the dimension of the ultramicroelectrode. An example of this is given. The main factor effect on the reaction order is the dimension of the ultramicroelectrode. The K4Fe(CN)6-aminopyrine system is selected to confirm the theory, the experiments showing that the system is a second order reaction at a 432 mum microelectrode, and a quasi-first order reaction at a 19 mum ultramicroelectrode. The kinetic constant of the system can be determined by applying the previous theory of homogeneous catalytic reaction.
Resumo:
A general characteristic of the electrochemical process coupling with a homogeneous catalytic reaction at an ultramicroelectrode under steady state is described. It was found that the electrochemical process coupling with homogeneous catalytic reaction has a similar steady state voltammetric wave at an ultramicroelectrode with arbitrary geometry. A method of determination for the kinetic constant of homogeneous catalytic reaction at an ultramicroelectrode with arbitrary geometry is proposed.
Resumo:
The electrochemical polymerization of amino-derivatives of naphthalene has been studied on the platinum wire electrodes. The effects of acidity of the modifying media and the potential scan rate on the cyclic voltammograms are verified. As potentiometric pH sensors, the electrodes prepared from 1-naphthylamine and 2,3-diaminonaphthalene showed performance characteristics superior to some other electrodes tested. The electrode modified with 1-naphthylamine in the optimum medium showed a nearly Nernstian response of 4.20-13.70 pH and a slope of -54.8 mV/pH, while the linear range of the electrode prepared by 2,3-diaminonaphthalene was 4.00-13.60 pH, with a slope of -52.4 mV/pH.
Resumo:
The preparation and the behaviour of a Prussian Blue (PB) film on a platinum microdisk electrode has been described. Electrocatalytic oxidation of ascorbic acid has occurred at the PB film modified microelectrode. This shows a typical example of a modified microelectrode in electrocatalysis following our previous theoretical studies (J. Electroanal. Chem., 309 (1991) 103) and the related catalytic reaction rate constant was determined.
Resumo:
The current equation of the electrocatalytic reaction at a microdisk electrode modified with redox species has been described and verified experimentally. There exists a linear relationship between plateau limiting current and the radius of the microdisk electrode for a catalytic process. The influence of the dimensions of the microdisk electrode on catalytic efficiency is discussed. The polyvinylferrocene (PVFc)-modified microdisk electrode prepared by the coating method was taken as a typical example, on which the electrocatalytic oxidation of ascorbic acid could be studied. The catalytic reaction rate constants were determined as an average value of 1.5 X 10(-7) cm3/mol s by this method, and are consistent with those obtained at a conventional electrode.
Resumo:
A wall-jet cell incorporating a carbon fibre array ring/glassy-carbon disk electrode has been constructed, and characterized by the cyclic voltammetry and flow-injection techniques. The ring (composed of several microdisks) and glassy-carbon disk electrode, can be used separately for different purposes, e.g., detection in solution without a supporting electrolyte, collection/shielding detection with dual-electrode and voltammetric/amperometric detection with series dual-electrode. The electrode shows better collection and shielding effects than usual ring-disk electrode in quiescent solution and the series dual-electrode in a thin-layer flow-through cell. The detection limit at the ring electrode is comparable with that at a conventional-size electrode, and has been used in the mobile phase without a supporting electrolyte, proving to be a promising detector for normal-phase liquid chromatography.
Resumo:
In developing a biosensor, the utmost important aspects that need to be emphasized are the specificity and selectivity of the transducer. These two vital prerequisites are of paramount in ensuring a robust and reliable biosensor. Improvements in electrochemical sensors can be achieved by using microelectrodes and to modify the electrode surface (using chemical or biological recognition layers to improve the sensitivity and selectivity). The fabrication and characterisations of silicon-based and glass-based gold microelectrode arrays with various geometries (band and disc) and dimension (ranging from 10 μm-100 nm) were reported. It was found that silicon-based transducers of 10 μm gold microelectrode array exhibited the most stable and reproducible electrochemical measurements hence this dimension was selected for further study. Chemical electrodeposition on both 10 μm microband and microdisc were found viable by electro-assisted self-assembled sol-gel silica film and nanoporous-gold electrodeposition respectively. The fabrication and characterisations of on-chip electrochemical cell was also reported with a fixed diameter/width dimension and interspacing variation. With this regard, the 10 μm microelectrode array with interspacing distance of 100 μm exhibited the best electrochemical response. Surface functionalisations on single chip of planar gold macroelectrodes were also studied for the immobilisation of histidine-tagged protein and antibody. Imaging techniques such as atomic force microscopy, fluorescent microscopy or scanning electron microscope were employed to complement the electrochemical characterisations. The long-chain thiol of self-assembled monolayer with NTA-metal ligand coordination was selected for the histidine-tagged protein while silanisation technique was selected for the antibody immobilisation. The final part of the thesis described the development of a T-2 labelless immunosensor using impedimetric approach. Good antibody calibration curve was obtained for both 10 μm microband and 10 μm microdisc array. For the establishment of the T-2/HT-2 toxin calibration curve, it was found that larger microdisc array dimension was required to produce better calibration curve. The calibration curves established in buffer solution show that the microelectrode arrays were sensitive and able to detect levels of T-2/HT-2 toxin as low as 25 ppb (25 μg kg-1) with a limit of quantitation of 4.89 ppb for a 10 μm microband array and 1.53 ppb for the 40 μm microdisc array.