938 resultados para inverse probability weights


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estimation of Taylor`s power law for species abundance data may be performed by linear regression of the log empirical variances on the log means, but this method suffers from a problem of bias for sparse data. We show that the bias may be reduced by using a bias-corrected Pearson estimating function. Furthermore, we investigate a more general regression model allowing for site-specific covariates. This method may be efficiently implemented using a Newton scoring algorithm, with standard errors calculated from the inverse Godambe information matrix. The method is applied to a set of biomass data for benthic macrofauna from two Danish estuaries. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two experiments were conducted on the nature of expert perception in the sport of squash. In the first experiment, ten expert and fifteen novice players attempted to predict the direction and force of squash strokes from either a film display (occluded at variable time periods before and after the opposing player had struck the ball) or a matched point-light display (containing only the basic kinematic features of the opponent's movement pattern). Experts outperformed the novices under both display conditions, and the same basic time windows that characterised expert and novice pick-up of information in the film task also persisted in the point-light task. This suggests that the experts' perceptual advantage is directly related to their superior pick-up of essential kinematic information. In the second experiment, the vision of six expert and six less skilled players was occluded by remotely triggered liquid-crystal spectacles at quasi-random intervals during simulated match play. Players were required to complete their current stroke even when the display was occluded and their prediction performance was assessed with respect to whether they moved to the correct half of the court to match the direction and depth of the opponent's stroke. Consistent with experiment 1, experts were found to be superior in their advance pick-up of both directional and depth information when the display was occluded during the opponent's hitting action. However, experts also remained better than chance, and clearly superior to less skilled players, in their prediction performance under conditions where occlusion occurred before any significant pre-contact preparatory movement by the opposing player was visible. This additional source of expert superiority is attributable to their superior attunement to the information contained in the situational probabilities and sequential dependences within their opponent's pattern of play.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The phenomenon of probability backflow, previously quantified for a free nonrelativistic particle, is considered for a free particle obeying Dirac's equation. It is known that probability backflow can occur in the opposite direction to the momentum; that is to say, there exist positive-energy states in which the particle certainly has a positive momentum in a given direction, but for which the component of the probability flux vector in that direction is negative. It is shown thar the maximum possible amount of probability that can flow backwards, over a given time interval of duration T, depends on the dimensionless parameter epsilon = root 4h/mc(2)T, where m is the mass of the particle and c is the speed of light. At epsilon = 0, the nonrelativistic value of approximately 0.039 for this maximum is recovered. Numerical studies suggest that the maximum decreases monotonically as epsilon increases from 0, and show that it depends on the size of m, h, and T, unlike the nonrelativistic case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In his study of the 'time of arrival' problem in the nonrelativistic quantum mechanics of a single particle, Allcock [1] noted that the direction of the probability flux vector is not necessarily the same as that of the mean momentum of a wave packet, even when the packet is composed entirely of plane waves with a common direction of momentum. Packets can be constructed, for example for a particle moving under a constant force, in which probability flows for a finite time in the opposite direction to the momentum. A similar phenomenon occurs for the Dirac electron. The maximum amount of probabilitiy backflow which can occur over a given time interval can be calculated in each case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a hybrid numerical method of an inverse approach to the design of compact magnetic resonance imaging magnets. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first, kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. The emphasis of this work is on the optimal design of short MRI magnets. Details of the hybrid numerical model are presented, and the model is used to investigate compact, symmetric MRI magnets as well as asymmetric magnets. The results highlight that the method can be used to obtain a compact MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1 m in length, significantly shorter than current designs. Viable asymmetric magnet designs, in which the edge of the homogeneous region is very close to one end of the magnet system are also presented. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00303-5].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the frequency of axillary metastasis in women with tubular carcinoma (TC) of the breast. Women who underwent axillary dissection for TC in the Western Sydney area (1984-1995) were identified retrospectively through a search of computerized records. A centralized pathology review was performed and tumours were classified as pure tubular (22) or mixed tubular (nine), on the basis of the invasive component containing 90 per cent or more, or 75-90 per cent tubule formation respectively. A Medline search of the literature was undertaken to compile a collective series (20 studies with a total of 680 patients) to address the frequency of nodal involvement in TC. A quantitative meta-analysis was used to combine the results of these studies. The overall frequency of nodal metastasis was five of 31 (16 per cent); one of 22 pure tubular and four of nine mixed tumours (P = 0.019). None of the tumours with a diameter of 10 mm or less (n = 16) had nodal metastasis compared with five of 15 larger tumours (P = 0.018). The meta-analysis of 680 women showed an overall frequency of nodal metastasis in TC of 13.8 (95 per cent confidence interval 9.3-18.3) per cent. The frequency of nodal involvement was 6.6 (1.7-11.4) per cent in pure TC (n = 244) and 25.0 (12.5-37.6) per cent in mixed TC (n = 149). A case may be made for observing the clinically negative axilla in women with a small TC (10 mm or less in diameter).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An inverse methodology is described to assist in the design of radio-frequency (RF) coils for magnetic resonance imaging (MRI) applications. The time-harmonic electromagnetic Green's functions are used to calculate current on the coil and shield cylinders that will generate a specified internal magnetic field. Stream function techniques and the method of moments are then used to implement this theoretical current density into an RF coil. A novel asymmetric coil operating for a 4.5 T MRI machine was designed and constructed using this methodology and the results are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aim of the study: Results of valve re-replacement (reoperation) in 898 patients undergoing aortic valve replacement with cryopreserved homograft valves between 1975 and 1998 are reported. The study aim was to provide estimates of unconditional probability of valve reoperation and cumulative incidence function (actual risk) of reoperation. Methods: Valves were implanted by subcoronary insertion (n = 500), inclusion cylinder (n = 46), and aortic root replacement (n = 352). Probability of reoperation was estimated by adopting a mixture model framework within which estimates were adjusted for two risk factors: patient age at initial replacement, and implantation technique. Results: For a patient aged 50 years, the probability of reoperation in his/her lifetime was estimated as 44% and 56% for non-root and root replacement techniques, respectively. For a patient aged 70 years, estimated probability of reoperation was 16% and 25%, respectively. Given that a reoperation is required, patients with non-root replacement have a higher hazard rate than those with root replacement (hazards ratio = 1.4), indicating that non-root replacement patients tend to undergo reoperation earlier before death than root replacement patients. Conclusion: Younger patient age and root versus non-root replacement are risk factors for reoperation. Valve durability is much less in younger patients, while root replacement patients appear more likely to live longer and hence are more likely to require reoperation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The image reconstruction using the EIT (Electrical Impedance Tomography) technique is a nonlinear and ill-posed inverse problem which demands a powerful direct or iterative method. A typical approach for solving the problem is to minimize an error functional using an iterative method. In this case, an initial solution close enough to the global minimum is mandatory to ensure the convergence to the correct minimum in an appropriate time interval. The aim of this paper is to present a new, simple and low cost technique (quadrant-searching) to reduce the search space and consequently to obtain an initial solution of the inverse problem of EIT. This technique calculates the error functional for four different contrast distributions placing a large prospective inclusion in the four quadrants of the domain. Comparing the four values of the error functional it is possible to get conclusions about the internal electric contrast. For this purpose, initially we performed tests to assess the accuracy of the BEM (Boundary Element Method) when applied to the direct problem of the EIT and to verify the behavior of error functional surface in the search space. Finally, numerical tests have been performed to verify the new technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Quantitative computed tomography (qCT)-based assessment of total lung weight (M(lung)) has the potential to differentiate atelectasis from consolidation and could thus provide valuable information for managing trauma patients fulfilling commonly used criteria for acute lung injury (ALI). We hypothesized that qCT would identify atelectasis as a frequent mimic of early posttraumatic ALI. Methods: In this prospective observational study, M(lung) was calculated by qCT in 78 mechanically ventilated trauma patients fulfilling the ALI criteria at admission. A reference interval for M(lung) was derived from 74 trauma patients with morphologically and functionally normal lungs (reference). Results are given as medians with interquartile ranges. Results: The ratio of arterial partial pressure of oxygen to the fraction of inspired oxygen was 560 (506 to 616) mmHg in reference patients and 169 (95 to 240) mmHg in ALI patients. The median reference M(lung) value was 885 (771 to 973) g, and the reference interval for M(lung) was 584 to 1164 g, which matched that of previous reports. Despite the significantly greater median M(lung) value (1088 (862 to 1,342) g) in the ALI group, 46 (59%) ALI patients had M(lung) values within the reference interval and thus most likely had atelectasis. In only 17 patients (22%), Mlung was increased to the range previously reported for ALI patients and compatible with lung consolidation. Statistically significant differences between atelectasis and consolidation patients were found for age, Lung Injury Score, Glasgow Coma Scale score, total lung volume, mass of the nonaerated lung compartment, ventilator-free days and intensive care unit-free days. Conclusions: Atelectasis is a frequent cause of early posttraumatic lung dysfunction. Differentiation between atelectasis and consolidation from other causes of lung damage by using qCT may help to identify patients who could benefit from management strategies such as damage control surgery and lung-protective mechanical ventilation that focus on the prevention of pulmonary complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To understand the dynamic mechanisms of the mechanical milling process in a vibratory mill, it is necessary to determine the characteristics of the impact forces associated with the collision events. However, it is difficult to directly measure the impact force in an operating mill. This paper describes an inverse technique for the prediction of impact forces from acceleration measurements on a vibratory ball mill. The characteristics of the vibratory mill have been investigated by the modal testing technique, and its system modes have been identified. In the modelling of the system vibration response to the impact forces, two modal equations have been used to describe the modal responses. The superposition of the modal responses gives rise to the total response of the system. A method based on an optimisation approach has been developed to predict the impact forces by minimising the difference between the measured acceleration of the vibratory ball mill and the predicted acceleration from the solution of the modal equations. The predicted and measured impact forces are in good agreement. Copyright (C) 1996 Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The acceptance-probability-controlled simulated annealing with an adaptive move generation procedure, an optimization technique derived from the simulated annealing algorithm, is presented. The adaptive move generation procedure was compared against the random move generation procedure on seven multiminima test functions, as well as on the synthetic data, resembling the optical constants of a metal. In all cases the algorithm proved to have faster convergence and superior escaping from local minima. This algorithm was then applied to fit the model dielectric function to data for platinum and aluminum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate retrospectively the midterm and long-term results of percutaneous endovascular treatment of venous outflow obstruction after pediatric liver transplantation. MATERIALS AND METHODS: During a 9-year period, 18 children with obstruction of a hepatic vein (HV) or inferior vena cava (IVC) anastomosis underwent percutaneous transluminal angioplasty (PTA) with balloon dilation or stent placement in case of PTA failure after liver transplantation. Patients` body weights ranged from 7.7 kg to 42.6 kg (mean, 18.8 kg +/- 9). Potential predictors of patency were compared between balloon dilation and stent placement groups. RESULTS: Forty-two procedures were performed (range, 1-11 per patient; mean, 2). Technical and initial clinical success were achieved in all cases. Major complications included one case of pulmonary artery stent embolization and one case of hemothorax. Three children (25%) with HV obstruction were treated with PTA and nine (75%) were treated with stent placement. Three children with IVC obstruction (75%) were treated with PTA and one (25%) was treated with a stent. There were two children with simultaneous obstruction at the HV and IVC; one was treated with PTA and the other with a stent. Cases of isolated HV stenosis have a higher probability of patency with balloon-expandable stent treatment compared with balloon dilation (P < .05). Follow-up time ranged from 7 days to 9 years (mean, 42 months +/- 31), and the primary assisted patency rate was 100% when stent placement was performed among the first three procedures. CONCLUSIONS: In cases of venous outflow obstruction resulting from HV and/or IVC lesions after pediatric liver transplantation, percutaneous endovascular treatment with balloon dilation or stent placement is a safe and effective alternative treatment that results in long-term patency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To examine whether there is an association between fetal and/or placental weight and exposure to ambient levels of air pollution in mice. Design: Chronic experiments on mice that were exposed to polluted vs. clean air. Setting: Environmental exposure to atmospheric pollution. Animal(S): Female Swiss mice (n = 70) were maintained at different stages of gestation in an exposure chamber located at an intersection with heavy traffic in a major city in Brazil. Control mice were maintained in a similar chamber, located adjacent to the exposure chamber but equipped with filters for particles and reactive gases. Intervention(s): Animals were divided into six groups as follows: no exposure, exposure to a polluted chamber throughout gestation, exposure to a polluted chamber during the 1st week of pregnancy, exposure to a polluted chamber during the 2nd and 3rd weeks, exposure to a polluted chamber during the 1st and 2nd week, and exposure to a polluted chamber during the 3rd week. Main Outcome Measure(S): At the end of the gestational period, the determination of fetal and placental weight was performed after cesarean section. Result(s): Exposure to air pollution during the 1st week of pregnancy promoted a significant reduction in fetal weight. Mice exposed to polluted air, in any phase of gestation, presented with lower placental weight in comparison to mice maintained in clean chambers. Conclusion(s): Exposure to ambient levels of traffic pollution at early phases of gestation is a determinant for decreased final fetal weight. Placental weight is reduced with exposure to air pollution at any phase of gestation. (Fertil Steril (R) 2008;90:1921-4. (C)2008 by American Society for Reproductive Medicine.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To assess whether baseline Glaucoma Probability Score (GPS; HRT-3; Heidelberg Engineering, Dossenheim, Germany) results are predictive of progression in patients with suspected glaucoma. The GPS is a new feature of the confocal scanning laser ophthalmoscope that generates an operator-independent, three-dimensional model of the optic nerve head and gives a score for the probability that this model is consistent with glaucomatous damage. METHODS. The study included 223 patients with suspected glaucoma during an average follow-up of 63.3 months. Included subjects had a suspect optic disc appearance and/or elevated intraocular pressure, but normal visual fields. Conversion was defined as development of either repeatable abnormal visual fields or glaucomatous deterioration in the appearance of the optic disc during the study period. The association between baseline GPS and conversion was investigated by Cox regression models. RESULTS. Fifty-four (24.2%) eyes converted. In multivariate models, both higher values of GPS global and subjective stereophotograph assessment ( larger cup-disc ratio and glaucomatous grading) were predictive of conversion: adjusted hazard ratios (95% CI): 1.31 (1.15 - 1.50) per 0.1 higher global GPS, 1.34 (1.12 - 1.62) per 0.1 higher CDR, and 2.34 (1.22 - 4.47) for abnormal grading, respectively. No significant differences ( P > 0.05 for all comparisons) were found between the c-index values ( equivalent to area under ROC curve) for the multivariate models (0.732, 0.705, and 0.699, respectively). CONCLUSIONS. GPS values were predictive of conversion in our population of patients with suspected glaucoma. Further, they performed as well as subjective assessment of the optic disc. These results suggest that GPS could potentially replace stereophotograph as a tool for estimating the likelihood of conversion to glaucoma.