936 resultados para gridding accuracy
Resumo:
In this paper the two main drawbacks of the heat balance integral methods are examined. Firstly we investigate the choice of approximating function. For a standard polynomial form it is shown that combining the Heat Balance and Refined Integral methods to determine the power of the highest order term will either lead to the same, or more often, greatly improved accuracy on standard methods. Secondly we examine thermal problems with a time-dependent boundary condition. In doing so we develop a logarithmic approximating function. This new function allows us to model moving peaks in the temperature profile, a feature that previous heat balance methods cannot capture. If the boundary temperature varies so that at some time t & 0 it equals the far-field temperature, then standard methods predict that the temperature is everywhere at this constant value. The new method predicts the correct behaviour. It is also shown that this function provides even more accurate results, when coupled with the new CIM, than the polynomial profile. Analysis primarily focuses on a specified constant boundary temperature and is then extended to constant flux, Newton cooling and time dependent boundary conditions.
Resumo:
Background: The posterior circulation Acute Stroke Prognosis Early CT Score (pc-ASPECTS) and the combined Pons-midbrain score quantify the extent of early ischemic changes in the posterior circulation. We compared the prognostic accuracy of both scores if applied to CT angiography (CTA) source images (CTA-SI) of patients in the Basilar Artery International Cooperation Study (BASICS).Methods: BASICS was a prospective, observational, multi-centre, registry of consecutive patients who presented with acute symptomatic basilar artery occlusion (BAO). Functional outcome was assessed at 1 month. We applied pc-ASPECTS and the combined Pons-midbrain score to CTA-SI by 3-reader-consensus. Readers were blinded to clinical data. We performed multivariable logistic regression analysis, adjusting for thrombolysis, baseline NIHSS score and age, and used the output to derive ROC curves to compare the ability of both scores to discriminate patients with favourable (modified Rankin Scale [mRS] scores 0-3) from patients with unfavourable (mRS scores 4-6) functional outcome.Results: We reviewed CTAs of 158 patients (64% men, mean age 65 _ 15 years, median NIHSS score 25 [0-38], median GCS score 7 [3-15], median onset-to-CTA time 234 minutes [11-7380]). At 1 month, 40 (25%) patients had a favourable outcome, 49 (31%) had an unfavourable outcome (mRS score 4-5) and 69 (44%) were deceased. Both techniques of assessing CTA-SI hypoattenuation in the posterior circulation showed equally good discriminative value in predicting final outcome (C-statistics; area under ROC curve 0.74 versus 0.75, respectively; p_0.37). Pc-ASPECTS dichotomized at _6 versus _6 was an independent predictor of favourable functional outcome (RR _ 2.2; CI95 1.1-4.7; p _ 0.034).Conclusion: Compared to the combined Pons-midbrain score, the pc-ASPECTS score has similar prognostic accuracy to identify patients with a favourable functional outcome in BASICS. Dichotomized pc-ASPECTS (_6 versus _6) is an independent predictor of favourable functional outcome in this population. Author Disclosures: V. Puetz: None. A. Khomenko: None. M.D. Hill: None. I. Dzialowski: None. P. Michel: None. C. Weimar: None. C.A.C. Wijman: None. H. Mattle: None. K. Muir: None. T. Pfefferkorn: None. D. Tanne: None. S. Engelter: None. K. Szabo: None. A. Algra: None. A.M. Demchuk: None. W.J. Schonewille: None.
Resumo:
BACKGROUND: Plasma free and urinary metanephrines are recognized biomarkers for the assessment of pheochromocytoma. Plasma total metanephrines with a long half-life may represent another useful biomarker. OBJECTIVE: The aim of this study is to evaluate the diagnostic performances of plasma total metanephrines alone or combined with free metanephrines and fractionated 24-h urinary metanephrines. METHODS: A retrospective, case-control diagnostic test study was conducted between 1999 and 2007 in two university hospitals in Switzerland and two institutions in France. The patients included 46 cases with histologically proven pheochromocytoma, and 181 controls suspected of tumor with negative investigations and 3-year follow-up. None had renal dysfunction. Sensitivity and specificity were compared after expressing each measurement result as a ratio over its upper reference limit, adding the ratios of normetanephrine and metanephrine, and defining cut-off values of 1 or 2 for this sum. RESULTS: Applying a cut-off value of 1, plasma free and total metanephrines and urinary fractionated metanephrines had similar sensitivities of 96% (95% confidence interval, 86-99%), 95% (85-99%), and 95% (84-99%) along with similar specificities of 89% (83-94%), 91% (84-95%), and 86% (80-91%). A cut-off of 2 for the sum of ratios over reference limit improves the specificity, and it can be used for a confirmation test based on another biomarker taken among the three biomarkers. CONCLUSION: All three metanephrine-based tests perform equivalently for diagnosing pheochromocytoma in the absence of renal insufficiency, and can be conveniently associated two by two for confirming/excluding tumor.
Resumo:
OBJECTIVE: To assess the change in non-compliant items in prescription orders following the implementation of a computerized physician order entry (CPOE) system named PreDiMed. SETTING: The department of internal medicine (39 and 38 beds) in two regional hospitals in Canton Vaud, Switzerland. METHOD: The prescription lines in 100 pre- and 100 post-implementation patients' files were classified according to three modes of administration (medicines for oral or other non-parenteral uses; medicines administered parenterally or via nasogastric tube; pro re nata (PRN), as needed) and analyzed for a number of relevant variables constitutive of medical prescriptions. MAIN OUTCOME MEASURE: The monitored variables depended on the pharmaceutical category and included mainly name of medicine, pharmaceutical form, posology and route of administration, diluting solution, flow rate and identification of prescriber. RESULTS: In 2,099 prescription lines, the total number of non-compliant items was 2,265 before CPOE implementation, or 1.079 non-compliant items per line. Two-thirds of these were due to missing information, and the remaining third to incomplete information. In 2,074 prescription lines post-CPOE implementation, the number of non-compliant items had decreased to 221, or 0.107 non-compliant item per line, a dramatic 10-fold decrease (chi(2) = 4615; P < 10(-6)). Limitations of the computerized system were the risk for erroneous items in some non-prefilled fields and ambiguity due to a field with doses shown on commercial products. CONCLUSION: The deployment of PreDiMed in two departments of internal medicine has led to a major improvement in formal aspects of physicians' prescriptions. Some limitations of the first version of PreDiMed were unveiled and are being corrected.
Resumo:
BACKGROUND Illiteracy, a universal problem, limits the utilization of the most widely used short cognitive tests. Our objective was to assess and compare the effectiveness and cost for cognitive impairment (CI) and dementia (DEM) screening of three short cognitive tests applicable to illiterates. METHODS Phase III diagnostic test evaluation study was performed during one year in four Primary Care centers, prospectively including individuals with suspicion of CI or DEM. All underwent the Eurotest, Memory Alteration Test (M@T), and Phototest, applied in a balanced manner. Clinical, functional, and cognitive studies were independently performed in a blinded fashion in a Cognitive Behavioral Neurology Unit, and the gold standard diagnosis was established by consensus of expert neurologists on the basis of these results. Effectiveness of tests was assessed as the proportion of correct diagnoses (diagnostic accuracy [DA]) and the kappa index of concordance (k) with respect to gold standard diagnoses. Costs were based on public prices at the time and hospital accounts. RESULTS The study included 139 individuals: 47 with DEM, 36 with CI, and 56 without CI. No significant differences in effectiveness were found among the tests. For DEM screening: Eurotest (k = 0.71 [0.59-0.83], DA = 0.87 [0.80-0.92]), M@T (k = 0.72 [0.60-0.84], DA = 0.87 [0.80-0.92]), Phototest (k = 0.70 [0.57-0.82], DA = 0.86 [0.79-0.91]). For CI screening: Eurotest (k = 0.67 [0.55-0.79]; DA = 0.83 [0.76-0.89]), M@T (k = 0.52 [0.37-0.67]; DA = 0.80 [0.72-0.86]), Phototest (k = 0.59 [0.46-0.72]; DA = 0.79 [0.71-0.86]). There were no differences in the cost of DEM screening, but the cost of CI screening was significantly higher with M@T (330.7 ± 177.1 €, mean ± sd) than with Eurotest (294.1 ± 195.0 €) or Phototest (296.0 ± 196. 5 €). Application time was shorter with Phototest (2.8 ± 0.8 min) than with Eurotest (7.1 ± 1.8 min) or M@T (6.8 ± 2.2 min). CONCLUSIONS Eurotest, M@T, and Phototest are equally effective. Eurotest and Phototest are both less expensive options but Phototest is the most efficient, requiring the shortest application time.
Resumo:
BACKGROUND Available screening tests for dementia are of limited usefulness because they are influenced by the patient's culture and educational level. The Eurotest, an instrument based on the knowledge and handling of money, was designed to overcome these limitations. The objective of this study was to evaluate the diagnostic accuracy of the Eurotest in identifying dementia in customary clinical practice. METHODS A cross-sectional, multi-center, naturalistic phase II study was conducted. The Eurotest was administered to consecutive patients, older than 60 years, in general neurology clinics. The patients' condition was classified as dementia or no dementia according to DSM-IV diagnostic criteria. We calculated sensitivity (Sn), specificity (Sp) and area under the ROC curves (aROC) with 95% confidence intervals. The influence of social and educational factors on scores was evaluated with multiple linear regression analysis, and the influence of these factors on diagnostic accuracy was evaluated with logistic regression. RESULTS Sixteen neurologists recruited a total of 516 participants: 101 with dementia, 380 without dementia, and 35 who were excluded. Of the 481 participants who took the Eurotest, 38.7% were totally or functionally illiterate and 45.5% had received no formal education. Mean time needed to administer the test was 8.2+/-2.0 minutes. The best cut-off point was 20/21, with Sn = 0.91 (0.84-0.96), Sp = 0.82 (0.77-0.85), and aROC = 0.93 (0.91-0.95). Neither the scores on the Eurotest nor its diagnostic accuracy were influenced by social or educational factors. CONCLUSION This naturalistic and pragmatic study shows that the Eurotest is a rapid, simple and useful screening instrument, which is free from educational influences, and has appropriate internal and external validity.
Resumo:
The aim of our study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable for the routine determination of blood CO concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature for CO measurement is the absence of a specific CO internal standard necessary for performing quantification. Even if stable isotope of CO is commercially available in the gaseous state, it is essential to develop a safer method to limit the manipulation of gaseous CO and to precisely control the injected amount of CO for spiking and calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in a vial in situ, an internal labeled standard gas ((13)CO) formed by the reaction of labeled formic acid formic acid (H(13)COOH) with sulfuric acid. As sulfuric acid can also be employed to liberate the CO reagent from whole blood, the procedure allows for the liberation of CO simultaneously with the generation of (13)CO. This method allows for precise measurement of blood CO concentrations from a small amount of blood (10 μL). Finally, this method was applied to measure the CO concentration of intoxicated human blood samples from autopsies.
Resumo:
When underwater vehicles navigate close to the ocean floor, computer vision techniques can be applied to obtain motion estimates. A complete system to create visual mosaics of the seabed is described in this paper. Unfortunately, the accuracy of the constructed mosaic is difficult to evaluate. The use of a laboratory setup to obtain an accurate error measurement is proposed. The system consists on a robot arm carrying a downward looking camera. A pattern formed by a white background and a matrix of black dots uniformly distributed along the surveyed scene is used to find the exact image registration parameters. When the robot executes a trajectory (simulating the motion of a submersible), an image sequence is acquired by the camera. The estimated motion computed from the encoders of the robot is refined by detecting, to subpixel accuracy, the black dots of the image sequence, and computing the 2D projective transform which relates two consecutive images. The pattern is then substituted by a poster of the sea floor and the trajectory is executed again, acquiring the image sequence used to test the accuracy of the mosaicking system
Resumo:
We present a computer vision system that associates omnidirectional vision with structured light with the aim of obtaining depth information for a 360 degrees field of view. The approach proposed in this article combines an omnidirectional camera with a panoramic laser projector. The article shows how the sensor is modelled and its accuracy is proved by means of experimental results. The proposed sensor provides useful information for robot navigation applications, pipe inspection, 3D scene modelling etc
Resumo:
A total of 138 isolates, 118 methicillin-resistant Staphylococcus aureus (MRSA) isolates (staphylococcal cassette chromosome type II, 20 isolates, type III, 39 isolates and type IV, 59 isolates) and 20 methicillin-sensitive S. aureus isolates were evaluated by phenotypic methods: cefoxitin and oxacillin disk diffusion (DD), agar dilution (AD), latex agglutination (LA), oxacillin agar screening (OAS) and chromogenic agar detection. All methods showed 100% specificity, but only the DD tests presented 100% sensitivity. The sensitivity of the other tests ranged from 82.2% (OAS)-98.3% (AD). The LA test showed the second lowest sensitivity (86.4%). The DD test showed high accuracy in the detection of MRSA isolates, but there was low precision in the detection of type IV isolates by the other tests, indicating that the genotypic characteristics of the isolates should be considered.
Resumo:
Introduction: Ethylglucuronide (EtG) is a direct and specific metabolite of ethanol. Its determination in hair is of increasing interest for detecting and monitoring alcohol abuse. The quantification of EtG in hair requires analytical methods showing highest sensitivity and specificity. We present a fully validated method based on gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS). The method was validated using French Society of Pharmaceutical Sciences and Techniques (SFSTP) guidelines which are based on the determination of the total measurement error and accuracy profiles. Methods: Washed and powdered hair is extracted in water using an ultrasonic incubation. After purification by Oasis MAX solid phase extraction, the derivatized EtG is detected and quantified by GC-NCI-MS/MS method in the selected reaction monitoring mode. The transitions m/z 347 / 163 and m/z 347 / 119 were used for the quantification and identification of EtG. Four quality controls (QC) prepared with hair samples taken post mortem from 2 subjects with a known history of alcoholism were used. A proficiency test with 7 participating laboratories was first run to validate the EtG concentration of each QC sample. Considering the results of this test, these samples were then used as internal controls for validation of the method. Results: The mean EtG concentrations measured in the 4 QC were 259.4, 130.4, 40.8, and 8.4 pg/mg hair. Method validation has shown linearity between 8.4 and 259.4 pg/mg hair (r2 > 0.999). The lower limit of quantification was set up at 8.4 pg/mg. Repeatability and intermediate precision were found less than 13.2% for all concentrations tested. Conclusion: The method proved to be suitable for routine analysis of EtG in hair. GC-NCI-MS/MS method was then successfully applied to the analysis of EtG in hair samples collected from different alcohol consumers.
Resumo:
BACKGROUND: The ASTRAL score was recently shown to reliably predict three-month functional outcome in patients with acute ischemic stroke. AIM: The study aims to investigate whether information from multimodal imaging increases ASTRAL score's accuracy. METHODS: All patients registered in the ASTRAL registry until March 2011 were included. In multivariate logistic-regression analyses, we added covariates derived from parenchymal, vascular, and perfusion imaging to the 6-parameter model of the ASTRAL score. If a specific imaging covariate remained an independent predictor of three-month modified Rankin score > 2, the area-under-the-curve (AUC) of this new model was calculated and compared with ASTRAL score's AUC. We also performed similar logistic regression analyses in arbitrarily chosen patient subgroups. RESULTS: When added to the ASTRAL score, the following covariates on admission computed tomography/magnetic resonance imaging-based multimodal imaging were not significant predictors of outcome: any stroke-related acute lesion, any nonstroke-related lesions, chronic/subacute stroke, leukoaraiosis, significant arterial pathology in ischemic territory on computed tomography angiography/magnetic resonance angiography/Doppler, significant intracranial arterial pathology in ischemic territory, and focal hypoperfusion on perfusion-computed tomography. The Alberta Stroke Program Early CT score on plain imaging and any significant extracranial arterial pathology on computed tomography angiography/magnetic resonance angiography/Doppler were independent predictors of outcome (odds ratio: 0·93, 95% CI: 0·87-0·99 and odds ratio: 1·49, 95% CI: 1·08-2·05, respectively) but did not increase ASTRAL score's AUC (0·849 vs. 0·850, and 0·8563 vs. 0·8564, respectively). In exploratory analyses in subgroups of different prognosis, age or stroke severity, no covariate was found to increase ASTRAL score's AUC, either. CONCLUSIONS: The addition of information derived from multimodal imaging does not increase ASTRAL score's accuracy to predict functional outcome despite having an independent prognostic value. More selected radiological parameters applied in specific subgroups of stroke patients may add prognostic value of multimodal imaging.
Resumo:
Malposition of the acetabular component during hip arthroplasty increases the occurrence of impingement, reduces range of motion, and increases the risk of dislocation and long-term wear. To prevent malpositioned hip implants, an increasing number of computer-assisted orthopaedic systems have been described, but their accuracy is not well established. The purpose of this study was to determine the reproducibility and accuracy of conventional versus computer-assisted techniques for positioning the acetabular component in total hip arthroplasty. Using a lateral approach, 150 cups were placed by 10 surgeons in 10 identical plastic pelvis models (freehand, with a mechanical guide, using computer assistance). Conditions for cup implantations were made to mimic the operating room situation. Preoperative planning was done from a computed tomography scan. The accuracy of cup abduction and anteversion was assessed with an electromagnetic system. Freehand placement revealed a mean accuracy of cup anteversion and abduction of 10 degrees and 3.5 degrees, respectively (maximum error, 35 degrees). With the cup positioner, these angles measured 8 degrees and 4 degrees (maximum error, 29.8 degrees), respectively, and using computer assistance, 1.5 degrees and 2.5 degrees degrees (maximum error, 8 degrees), respectively. Computer-assisted cup placement was an accurate and reproducible technique for total hip arthroplasty. It was more accurate than traditional methods of cup positioning.