897 resultados para effluent discharge
Resumo:
The main goal of this research study was the removal of Cu(II), Ni(II) and Zn(II) from aqueous solutions using peanut hulls. This work was mainly focused on the following aspects: chemical characterization of the biosorbent, kinetic studies, study of the pH influence in mono-component systems, equilibrium isotherms and column studies, both in mono and tri-component systems, and with a real industrial effluent from the electroplating industry. The chemical characterization of peanut hulls showed a high cellulose (44.8%) and lignin (36.1%) content, which favours biosorption of metal cations. The kinetic studies performed indicate that most of the sorption occurs in the first 30 min for all systems. In general, a pseudo-second order kinetics was followed, both in mono and tri-component systems. The equilibrium isotherms were better described by Freundlich model in all systems. Peanut hulls showed higher affinity for copper than for nickel and zinc when they are both present. The pH value between 5 and 6 was the most favourable for all systems. The sorbent capacity in column was 0.028 and 0.025 mmol g-1 for copper, respectively in mono and tri-component systems. A decrease of capacity for copper (50%) was observed when dealing with the real effluent. The Yoon-Nelson, Thomas and Yan’s models were fitted to the experimental data, being the latter the best fit.
Resumo:
Geostatistics has been successfully used to analyze and characterize the spatial variability of environmental properties. Besides giving estimated values at unsampled locations, it provides a measure of the accuracy of the estimate, which is a significant advantage over traditional methods used to assess pollution. In this work universal block kriging is novelty used to model and map the spatial distribution of salinity measurements gathered by an Autonomous Underwater Vehicle in a sea outfall monitoring campaign, with the aim of distinguishing the effluent plume from the receiving waters, characterizing its spatial variability in the vicinity of the discharge and estimating dilution. The results demonstrate that geostatistical methodology can provide good estimates of the dispersion of effluents that are very valuable in assessing the environmental impact and managing sea outfalls. Moreover, since accurate measurements of the plume’s dilution are rare, these studies might be very helpful in the future to validate dispersion models.
Resumo:
Dissertação apresentada à Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia do Ambiente, Gestão de Sistemas Ambientais
Resumo:
Mestrado integrado em Engenharia do Ambiente, perfil: Gestão de Sistemas Ambientais
Resumo:
ABSTRACT OBJECTIVE To identify individual and hospital characteristics associated with the risk of readmission in older inpatients for proximal femoral fracture in the period of 90 days after discharge. METHODS Deaths and readmissions were obtained by a linkage of databases of the Hospital Information System of the Unified Health System and the System of Information on Mortality of the city of Rio de Janeiro from 2008 to 2011. The population of 3,405 individuals aged 60 or older, with non-elective hospitalization for proximal femoral fracture was followed for 90 days after discharge. Cox multilevel model was used for discharge time until readmission, and the characteristics of the patients were used on the first level and the characteristics of the hospitals on the second level. RESULTS The risk of readmission was higher for men (hazard ratio [HR] = 1.37; 95%CI 1.08–1.73), individuals more than 79 years old (HR = 1.45; 95%CI 1.06–1.98), patients who were hospitalized for more than two weeks (HR = 1.33; 95%CI 1.06-1.67), and for those who underwent arthroplasty when compared with the ones who underwent osteosynthesis (HR = 0.57; 95%CI 0.41–0.79). Besides, patients admitted to state hospitals had lower risk for readmission when compared with inpatients in municipal (HR = 1.71; 95%CI 1.09–2.68) and federal hospitals (HR = 1.81; 95%CI 1.00–3.27). The random effect of the hospitals in the adjusted model remained statistically significant (p < 0.05). CONCLUSIONS Hospitals have complex structures that reflect in the quality of care. Thus, we propose that future studies may include these complexities and the severity of the patients in the analysis of the data, also considering the correlation between readmission and mortality to reduce biases.
Resumo:
We report and analyze the halting of the fuse effect propagation in optical fiber microwires. The increase of the mode field diameter in the tapered region decreases the optical intensity resulting in the extinction of the fuse effect. This fiber element presents a low insertion loss and can be introduced in the optical network in order to protect the active equipment from the damage caused by the fuse effect.
Resumo:
We report and analyze the halting of the fuse effect propagation in optical fiber microwires. The increase of the mode field diameter in the tapered region decreases the optical intensity resulting in the extinction of the fuse effect. This fiber element presents a low insertion loss and can be introduced in the optical network in order to protect the active equipment from the damage caused by the fuse effect. (C) 2012 Optical Society of America
Resumo:
Esta dissertação teve como objetivo clarificar a qualidade das águas residuais de uma indústria de fabricação de adesivos. Para esta clarificação optou-se por um tratamento de coagulação/floculação a ser efetuado com a adição de apenas um produto no estado sólido. Para este estudo, selecionou-se substâncias comercialmente disponíveis destacando-se para esta formulação um coagulante, sulfato de alumínio (Al2 (SO4).3H2O, dois adjuvantes, hidróxido de cálcio, Ca(OH)2 (adjuvante H) e Montmorillonite, Al2O3.4SiO2.H2O (adjuvante M) e um floculante, uma poliacrilamida aniónica (C3H5NO)n. O efluente bruto da indústria de adesivos foi caraterizado e verificou-se que dos parâmetros analisados, apenas o pH obedece aos valores limite de emissão para descarga no coletor municipal. Determinaram-se as quantidades ótimas das substâncias selecionadas, a quantidade mínima de produto formulado e foi feita a otimização da composição do produto formulado, para três níveis de pH e duas condições de agitação Numa primeira fase, a realização de ensaios preliminares sobre a quantidade de cada uma das substâncias conduziu aos valores 5 e 30 g de coagulante, 2 e 10 g de adjuvante M; 3 g de adjuvante H e 0,01 g de floculante por 500 mL de efluente. Na otimização da quantidade mínima de produto formulado obteve-se o valor de 5g de produto por 500 mL de efluente. Relativamente à formulação do produto foi definido estudar o efeito da variação das razões, %(m/m), dos adjuvantes (M e H) em função do coagulante, para diferentes valores de pH inicial (6,2; 8,1 e 10) e para duas condições de agitação (A e B), sobre os parâmetros analisados (CQO, SST, turvação, pH final e IVL). Na condição A manteve-se uma agitação de 150 rpm durante 2 minutos, reduzindo-se para 60 rpm durante 15 minutos e, por fim, para 30 rpm durante 5 minutos. Na condição B foi usada uma agitação constante de 90 rpm durante 22 minutos. O estudo do efeito das variações das razões % (m/m) dos adjuvantes M e H foi dividido em três grupos com três subgrupos: 1º grupo - 0,6 a razão mássica adjuvante M/coagulante e 0,4, 1,2 e 2 a razão mássica adjuvante H/ coagulante; 2º grupo - 0,2 a razão mássica adjuvante M/coagulante e 0,1, 0,4 e 0,6 a razão mássica adjuvante H/ coagulante; 3º grupo - 0,1 a razão mássica adjuvante M/coagulante e 0,1, 0,2 e 0,3 a razão mássica adjuvante H/ coagulante. Após este estudo obteve-se para cada condição de agitação (A e B), as razões %(m/m) e o pH inicial mais adequados, com base nos melhores resultados obtidos no efeito sobre a CQO. Para a condição de agitação A o melhor resultado obteve-se para pH inicial igual a 8,1 com a razão mássica de adjuvante M/ coagulante igual a 0,1 e a razão mássica de adjuvante H/coagulante igual a 0,1 (percentagens de remoção de 98,01%, 99,60% e 99,43% para a CQO, SST e turvação, respetivamente). Para a condição de agitação B o melhor resultado obteve-se para pH inicial igual a 8,1 com a razão mássica de adjuvante M/ coagulante igual a 0,1 e a razão mássica de adjuvante H/coagulante igual a 0,1 (percentagens de remoção de 98,67%, 99,77% e 98,40% para a CQO, SST e turvação, respetivamente). Nestas condições é necessário efetuar a correção do pH após o tratamento. Apesar das elevadas percentagens de remoção obtidas, o índice volumétrico de lamas indica fraca qualidade de sedimentação.
Resumo:
In this work, kriging with covariates is used to model and map the spatial distribution of salinity measurements gathered by an autonomous underwater vehicle in a sea outfall monitoring campaign aiming to distinguish the effluent plume from the receiving waters and characterize its spatial variability in the vicinity of the discharge. Four different geostatistical linear models for salinity were assumed, where the distance to diffuser, the west-east positioning, and the south-north positioning were used as covariates. Sample variograms were fitted by the Mat`ern models using weighted least squares and maximum likelihood estimation methods as a way to detect eventual discrepancies. Typically, the maximum likelihood method estimated very low ranges which have limited the kriging process. So, at least for these data sets, weighted least squares showed to be the most appropriate estimation method for variogram fitting. The kriged maps show clearly the spatial variation of salinity, and it is possible to identify the effluent plume in the area studied. The results obtained show some guidelines for sewage monitoring if a geostatistical analysis of the data is in mind. It is important to treat properly the existence of anomalous values and to adopt a sampling strategy that includes transects parallel and perpendicular to the effluent dispersion.
Resumo:
OBJECTIVES: Mortality after ICU discharge accounts for approx. 20-30% of deaths. We examined whether post-ICU discharge mortality is associated with the presence and severity of organ dysfunction/failure just before ICU discharge. PATIENTS AND METHODS: The study used the database of the EURICUS-II study, with a total of 4,621 patients, including 2,958 discharged alive to the general wards (post-ICU mortality 8.6%). Over a 4-month period we collected clinical and demographic characteristics, including the Simplified Acute Physiology Score (SAPS II), Nine Equivalents of Nursing Manpower Use Score, and Sequential Organ Failure Assessment (SOFA) score. RESULTS: Those who died in the hospital after ICU discharge had a higher SAPS II score, were more frequently nonoperative, admitted from the ward, and had stayed longer in the ICU. Their degree of organ dysfunction/failure was higher (admission, maximum, and delta SOFA scores). They required more nursing workload resources while in the ICU. Both the amount of organ dysfunction/failure (especially cardiovascular, neurological, renal, and respiratory) and the amount of nursing workload that they required on the day before discharge were higher. The presence of residual CNS and renal dysfunction/failure were especially prognostic factors at ICU discharge. Multivariate analysis showed only predischarge organ dysfunction/failure to be important; thus the increased use of nursing workload resources before discharge probably reflects only the underlying organ dysfunction/failure. CONCLUSIONS: It is better to delay the discharge of a patient with organ dysfunction/failure from the ICU, unless adequate monitoring and therapeutic resources are available in the ward.
Resumo:
A atividade humana e industrial usa a água para as suas atividades do quotidiano. A água é um recurso natural escasso cuja qualidade deve ser protegida, defendida, gerida e tratada em conformidade com o seu uso. Nesse âmbito, a gestão das águas prossegue objetivos de proteção da saúde humana e de preservação, proteção e melhoria da qualidade do ambiente[1]. Desde o final do seculo XIX até aos dias de hoje, verificou-se uma forte evolução nos sistemas de tratamento de águas residuais. Esta evolução foi fundamental para dar resposta às maiores exigências de qualidade do efluente tratado. O sistema de lamas ativadas é um dos processos de tratamento biológico das águas residuais mais usados em todo o mundo. Este trabalho consiste no desenvolvimento do projeto de conceção e dimensionamento de uma Estação de Tratamento de Águas Residuais (ETAR) para servir um pequeno aglomerado de cerca de 3200 habitantes equivalentes (hab.eq.), tendo como objetivo o dimensionamento de todas as etapas de tratamento necessárias ao cumprimento da legislação em vigor para a descarga das águas residuais urbanas no meio recetor. O Decreto-lei nº 152/97[2], relativo ao tratamento de águas residuais urbanas, juntamente com o Decreto-lei nº 149/2004[3] que identifica as zonas sensíveis e de zonas menos sensíveis, permitem que as entidades licenciadoras definam o grau de tratamento que a instalação deve possuir tendo em consideração a classificação do meio onde o efluente tratado é descarregado. O Decreto-Lei n.º 135/2009[1] estabelece o regime de identificação, gestão, monitorização e classificação da qualidade das águas balneares, impondo a qualidade microbiológica da água residual tratada mediante o meio recetor, e portanto conseguindo-se assim definir o tratamento de desinfeção a adotar. Resumidamente, a conceção do tratamento focou as seguintes etapas: tratamento preliminar formado por uma unidade compacta de tamisação, desarenador e desengordurador, tratamento secundário por lamas ativadas em regime de arejamento prolongado constituído por dois reatores com cerca de 400 m3 de volume seguido de um decantador com um diâmetro de 9.5 m, tratamento terciário de desinfeção composto por uma microtamisação seguido de desinfeção UV, e a utilização das operações comuns de espessamento e desidratação das lamas produzidas em excesso pelo tratamento, constituída por com um espessador gravítico com 4.6 m de diâmetro, e um filtro banda para a desidratação.
Resumo:
Introduction Surgical site infections (SSIs) often manifest after patients are discharged and are missed by hospital-based surveillance. Methods We conducted a case-reference study nested in a prospective cohort of patients from six surgical specialties in a teaching hospital. The factors related to SSI were compared for cases identified during the hospital stay and after discharge. Results Among 3,427 patients, 222 (6.4%) acquired an SSI. In 138 of these patients, the onset of the SSI occurred after discharge. Neurological surgery and the use of steroids were independently associated with a greater likelihood of SSI diagnosis during the hospital stay. Conclusions Our results support the idea of a specialty-based strategy for post-discharge SSI surveillance.
Resumo:
Source point treatment of effluents with a high load of pharmaceutical active compounds (PhACs), such as hospital wastewater, is a matter of discussion among the scientific community. Fungal treatments have been reported to be successful in degrading this type of pollutants and, therefore, the white-rot fungus Trametes versicolor was applied for the removal of PhACs from veterinary hospital wastewater. Sixty-six percent removal was achieved in a non-sterile batch bioreactor inoculated with T. versicolor pellets. On the other hand, the study of microbial communities by means of DGGE and phylogenetic analyses led us to identify some microbial interactions and helped us moving to a continuous process. PhAC removal efficiency achieved in the fungal treatment operated in non-sterile continuous mode was 44 % after adjusting the C/N ratio with respect to the previously calculated one for sterile treatments. Fungal and bacterial communities in the continuous bioreactors were monitored as well.
Resumo:
Recent studies have shown that septic tank systems are a major source of groundwater pollution. Many public health workers feel that the most cri^cal aspect of the use of septic tanks as a means of sewage disposal is the contamination of private water wells with attendant human health hazards. In this study the movement and attenuation of septic tank effluents in a range of soil/overburden types and hydrogeological situations was investigated. The suitability of a number of chemical and biological tracer materials to monitor the movement of septic tank effluent constituents to groundwater sources was also examined. The investigation was divided into three separate but inteiTelated sections. In the first section of the study the movement of septic tank effluent from two soil treatment systems was investigated by direct measurements of soil nutrient concentrations and enteric bacterial numbers in the soil beneath and downgradient of the test systems. Two sites with different soil types and hydrogeological characteristics were used. The results indicated that the attenuation of the effluent in both of the treatment systems was incomplete. Migration of nitrate, ammonium, phosphate and fecal bacteria to a depth of 50 cm beneath the inverts of the distribution tiles was demonstrated on all sampling occasions. The lateral migration of the pollutants was less pronounced, although on occasions high nutrients levels and fecal bacterial numbers were detected at a lateral distance of 4.0 m downgradient of the test systems. There was evidence that the degree and extent of effluent migration was increased after periods of heavy or prolonged rainfall when the attenuating properties of the treatment systems were reduced as a result of saturation of the soil. The second part of the study examined the contamination of groundwaters downgradient of septic tank soil treatment systems. Three test sites were used in the investigation. The sites were chosen because of differences in the thicknesses and nature of the unsaturated zone available for effluent attenuation at each of the locations. A series of groundwater monitoring boreholes were installed downgradient of the test systems at each of the sites and these were sampled regularly to assess the efficiency of the overburden material in reducing the polluting potential of the wastewater. Effluent attenuation in the septic tank treatment systems was shown to be incomplete, resulting in chemical and microbiological contamination of the groundwaters downgradient of the systems. The nature and severity of groundwater contamination was dependent on the composition and thickness of the unsaturated zone and the extent of weathering in the underlying saturated bedrock. The movement of septic tank effluent through soil/overburdens to groundwater sources was investigated by adding a range of chemical and biological tracer materials to the three septic tank systems used in section two of the study. The results demonstrated that a single tracer type cannot be used to accurately monitor the movement of all effluent constituents through soils to groundwater. The combined use of lithium bromide and endospores of Bacillus globigii was found to give an accurate indication of the movement of both the chemical and biological effluent constituents.
Resumo:
Background:Effective interventions to improve medication adherence are usually complex and expensive.Objective:To assess the impact of a low-cost intervention designed to improve medication adherence and clinical outcomes in post-discharge patients with CVD.Method:A pilot RCT was conducted at a teaching hospital. Intervention was based on the four-item Morisky Medication Adherence Scale (MMAS-4). The primary outcome measure was medication adherence assessed using the eight-item MMAS at baseline, at 1 month post hospital discharge and re-assessed 1 year after hospital discharge. Other outcomes included readmission and mortality rates.Results:61 patients were randomized to intervention (n = 30) and control (n = 31) groups. The mean age of the patients was 61 years (SD 12.73), 52.5% were males, and 57.4% were married or living with a partner. Mean number of prescribed medications per patient was 4.5 (SD 3.3). Medication adherence was correlated to intervention (p = 0.04) and after 1 month, 48.4% of patients in the control group and 83.3% in the intervention group were considered adherent. However, this difference decreased after 1 year, when adherence was 34.8% and 60.9%, respectively. Readmission and mortality rates were related to low adherence in both groups.Conclusion:The intervention based on a validated patient self-report instrument for assessing adherence is a potentially effective method to improve adherent behavior and can be successfully used as a tool to guide adherence counseling in the clinical visit. However, a larger study is required to assess the real impact of intervention on these outcomes.