974 resultados para dental prostheses
Resumo:
OBJECTIVE To compare the precision of fit of long-span vs. short-span implant-supported screw-retained fixed dental prostheses (FDPs) made from computer-aided-design/computer-aided-manufactured (CAD/CAM) titanium and veneered with ceramic. The null hypothesis was that there is no difference in the vertical microgap between long-span and short-span FDPs. MATERIALS AND METHODS CAD/CAM titanium frameworks for an implant-supported maxillary FDP on implants with a flat platform were fabricated on one single master cast. Group A consisted of six 10-unit FDPs connected to six implants (FDI positions 15, 13, 11, 21, 23, 25) and group B of six 5-unit FDPs (three implants, FDI positions 21, 23, 25). The CAD/CAM system from Biodenta Swiss AG (Berneck, Switzerland) was used for digitizing (laser scanner) the master cast and anatomical CAD of each framework separately. The frameworks were milled (CAM) from a titanium grade V monobloc and veneered with porcelain. Median vertical distance between implant and FDP platforms from the non-tightened implants (one-screw test on implant 25) was calculated from mesial, buccal, and distal scanning electron microscope measurements. RESULTS All measurements showed values <40 μm. Total median vertical microgaps were 23 μm (range 2-38 μm) for group A and 7 μm (4-24 μm) for group B. The difference between the groups was statistically significant at implant 21 (P = 0.002; 97.5% CI -27.3 to -4.9) and insignificant at implant 23 (P = 0.093; -3.9 to 1.0). CONCLUSIONS CAD/CAM fabrication including laboratory scanning and porcelain firing was highly precise and reproducible for all long- and short-span FDPs. While all FDPs showed clinically acceptable values, the short-span FDPs were statistically more precise at the 5-unit span distance.
Resumo:
Objetivo: Conocer los hábitos higiénicos en el colectivo de pacientes durante su estancia en el Hospital de la Magdalena de Castellón e identificar patologías causadas por posibles hábitos higiénicos bucodentales inadecuados. Metodología: Se trata de un estudio descriptivo transversal observacional basado en datos de registro e información de pacientes y cuidadores principales. Se seleccionó una muestra de 50 pacientes en el Hospital de la Magdalena de Castellón hospitalizados. Se realizó un examen odontológico a partir de datos recogidos en un registro diseñado para tal fin. Se usó el índice de LÖE y SILNESS y el índice VIGILD M. Para evaluar la satisfacción se utiliza el test GOHAI. El análisis de los datos se realiza con el programa estadístico R, en el cual saldrán los porcentajes de las patologías BD y hábitos de higiene diarios de los pacientes hospitalizados. Resultados: La edad media de los pacientes estudiados es de 68 años; la mayoría hombres (70%). Observamos en nuestro estudio que las mujeres no fuman y que sus hábitos higiénicos, patologías encontradas son mejores que en los hombres. Sin embargo un 100% de los pacientes estudiados necesitan atención bucodental. Conclusiones: En este estudio se observan problemas de higiene bucodental en los pacientes hospitalizados en un centro de larga estancia de Castellón.
Resumo:
This study presents a simple, fast and low cost technique for fabrication new conventional dentures from the duplication of old prosthesis in use by the patient. Colorless acrylic resin was poured into the moulds obtained by duplication of prosthesis. With the replicas obtained a functional impressions using polyether should be performed and they are stabilized with occlusal registration in acrylic resin. The molds need to be castings and mounted on an semi-adjustable articulator. The artificial teeth are positioned with the assistance of a guide made condensation silicone to reproduce the positioning of the teeth of the old prosthesis and fixed with wax 7. After approval of the teeth on the trial in wax, without adjustment of the planes, the prosthesis may be processed in the laboratory. After occlusal adjustment in the articulator the same can be installed.
Resumo:
The past few decades have brought many changes to the dental practice and the technology has become ready available. The result of a satisfactory rehabilitation treatment basically depends on the balance between biological and mechanical factors. The marginal adaptation of crowns and prosthetic structures is vital factor for long-term success. The development of CAD / CAM technology in the manufacture of dental prostheses revolutionized dentistry, this technology is capable of generating a virtual model from the direct digital scanning from the mouth, casts or impressions. It allows the planning and design of the structure in a computered software. The virtual projects are obtained with high precision and a significant reduction in clinical and laboratory time. Thus, the present study (Chapters 1, 2 and 3) computed microtomography was used to evaluate, different materials, different CAD/CAM systems, different ways of obtaining virtual model (with direct or indirect scanning), and in addition, also aims to evaluate the influence of cementing agent in the final adaptation of crowns and copings obtained by CAD / CAM. Furthermore, this study (Chapter 4, 5 and 6) also aims to evaluate significant differences in vertical and horizontal misfits in abutment-free frameworks on external hexagon implants (HE) using full castable UCLAs, castable UCLAs with cobalt-chromium pre-machined bases and obtained by CAD / CAM with CoCr or Zirconia by different scanning and milling systems. For this, the scanning electron microscopy and interferometry were used. It was concluded that the CAD / CAM technology is capable to produce restorations, copings and screw-retained implant-supported frameworks in different materials and systems offering satisfactory results of marginal accuracy, with significative reduction in clinical and laboratory time.
Resumo:
Ceramics materials have good properties including chemical stability, high hardness and wear resistance. Moreover, due to its fragility, can suffer failure under relatively low levels of tension. Actually zirconia is the material of choice in metal free dental prostheses used in dentistry due its inertia in physiological environment, good bending strength, hardness and fracture toughness. The alumina and mixed tungsten and titanium carbides additions, acting as reinforcement elements in the zirconia matrix, have as their main objective the improvement of mechanical properties of this material. In this work, samples of zirconia, zirconia with 30% wt of alumina and zirconia with 30% wt mixed carbides were analyzed. The samples were sintered by uniaxial hot pressing on 30 MPa pressure, for 1 hour in an argon atmosphere. They were physically characterized by porosity and density measurements, and mechanically by 3-points bending strength and Vickers microhardness. The X-ray diffraction was used for the phase identifications and microstructure was examined by scanning electron microscopy (SEM). The addition of mixed carbides as reinforcement elements in zirconia matrix provides improvements in all properties analyzed in this work. The alumina addition has dropped the zirconia strength, although it caused improvement in other properties
Resumo:
Objective: The aim of this study was to analyse denture users' oral care habits with regard to the use of their prostheses. Background: Rehabilitative treatment is only successful when patients are motivated and aware of correct prosthesis use and hygiene. Materials and methods: Questionnaires were distributed to 150 complete denture users at the Federal University of Bahia School of Dentistry, the Esmeralda Natividade Health Center, the Bahian Science Development Foundation and a Salvador nursing home. The questionnaire included information on gender, age, length of prosthesis use, cleaning methods and materials, etc. The data were analysed using EpiInfo version 6 software. The chi-squared test was used for statistical analysis, with a significance level of 5%. Results: Questionnaire results showed that 78% of the subjects, with an average age of 67.3 years, had used the same complete denture for over 5 years. 64% slept with their prostheses and 44% removed them from the mouth only for cleaning. None of the patients interviewed knew anything about brushes designed specifically for complete dentures. 37.3% had a restricted diet and 44% believed that a complete denture would last for more than 10 years. Conclusion: Within the limitations of this study, it was concluded that the edentulous patients surveyed had limited awareness of prosthetic hygiene and long-term oral care despite extended periods of denture use. © 2008 The Authors.
Resumo:
The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.
Resumo:
The purpose of this study was to evaluate skeletal and dental stability in patients who had temporomandibular joint (TMJ) reconstruction and mandibular counterclockwise advancement using TMJ Concepts total join, prostheses (TMJ Concepts Inc. Ventura, CA) with maxillary osteotomies being performed at the same operation. All patients were operated at Baylor University Medical Center, Dallas TX, USA, by one surgeon (Wolford). Forty-seven females were studied; the average post-surgical follow-up was 40.6 months. Lateral cephalograms were analyzed to estimate surgical and post-surgical changes. During surgery, the occlusal plane angle decreased 14.9 +/- 8.0 degrees. The maxilla moved forward and upward. The posterior nasal spine moved downward and forward. The mandible advanced 7.9 +/- 3.5 mm at the lower incisor tips, 12.4 +/- 5.4 mm at Point B, 17.3 +/- 7.0 mm at menton, 18.4 +/- 8.5 mm at pogonion, and 11.0 +/- 5.3 mm at gonion. Vertically, the lower incisors moved upward -2.9 +/- 4.0 mm. At the longest follow-up post surgery, the maxilla showed minor horizontal changes while all mandibular measurements remained stable. TMJ reconstruction and mandibular advancement with TMJ Concepts total joint prosthesis in conjunction with maxillary osteotomies for counter-clockwise rotation of the rnaxillo-mandibular complex was a stable procedure for these patients at the longest follow-up.
Resumo:
To evaluate the hard and the soft tissue parameters around implants supporting fixed prostheses over a period of 5 years and the possible association to the increase in periimplant bone density (IPBD).
Resumo:
This case report details the successful rehabilitation of an edentulous patient using a complete upper prosthesis and a lower implant retained overdenture. The provision of care was split between a specialist centre and a primary care setting. This approach reduced inconvenience to the patient. Modern surgical and prosthodontic techniques also reduced the total delivery time. After initial consultation a new set of complete dentures was prescribed with changes in design to the originals. The patient was also planned for placement of two mandibular implants to stabilise and retain the mandibular denture. The first line of treatment involved provision of a new set of dentures constructed by the patient's general dental practitioner. Dental implants were then placed in a specialist centre and the patient returned to the dental practice for attachment of the lower denture to the dental implants. The benefits and success of mandibular implant retained dentures are well documented. With delivery of the overdenture, the patient reported increased satisfaction with his prostheses which allowed him to eat a greater range of foods and enabled him to feel confident when speaking and socialising.
Resumo:
Purpose: The aim of this study was to evaluate, through histomorphometric analysis, the effect that different loading times would have on the bone response around implants. Materials and Methods: Three Replace Select implants were placed on each side of the mandible in eight dogs (n = 48 implants). One pair of implants was selected for an immediate loading protocol (IL). After 7 days, the second pair of implants received prostheses for an early loading protocol (EL). Fourteen days after implant placement, the third pair of implants received prostheses for advanced early loading (AEL). Following 12 weeks of prosthetics, counted following the positioning of the metallic crowns for the AEL group, the animals were sacrificed and the specimens were prepared for histomorphometric analysis. The differences between loading time in the following parameters were evaluated through analysis of variance: bone-to-implant contact, bone density, and crestal bone loss. Results: The mean percentage of bone-to-implant contact for IL was 77.9% +/- 1.71%, for EL it was 79.25% +/- 2.11%, and for AEL it was 79.42% +/- 1.49%. The mean percentage of bone density for IL was 69.97% +/- 3.81%, for EL it was 69.23% +/- 5.68%, and for AEL it was 69.19% +/- 2.90%. Mean crestal bone loss was 1.57 +/- 0.22 mm for IL, 1.23 +/- 0.19 mm for EL, and 1.17 +/- 0.32 mm for AEL. There was no statistical difference for any of the parameters evaluated (P > .05). Conclusion: Different early loading times did not seem to significantly affect the bone response around dental implants. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:473-481
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of this study was to present the factors that influence planning for immediate loading of implants through a literature review for treatment success. Research was conducted in the PubMed database including the key words immediate implant loading, implant-supported prostheses, and implant planning for studies published from 2000 to 2011. Forty-eight articles were used in this review to describe the indications and counterindications, presurgical planning, and technologies available for planning of this treatment alternative.
Resumo:
Purpose: The aim of this study was to assess the influence of cusp inclination on stress distribution in implant-supported prostheses by 3D finite element method.Materials and Methods: Three-dimensional models were created to simulate a mandibular bone section with an implant (3.75 mm diameter x 10 mm length) and crown by means of a 3D scanner and 3D CAD software. A screw-retained single crown was simulated using three cusp inclinations (10 degrees, 20 degrees, 30 degrees). The 3D models (model 10d, model 20d, and model 30d) were transferred to the finite element program NeiNastran 9.0 to generate a mesh and perform the stress analysis. An oblique load of 200 N was applied on the internal vestibular face of the metal ceramic crown.Results: The results were visualized by means of von Mises stress maps. Maximum stress concentration was located at the point of application. The implant showed higher stress values in model 30d (160.68 MPa). Cortical bone showed higher stress values in model 10d (28.23 MPa).Conclusion: Stresses on the implant and implant/abutment interface increased with increasing cusp inclination, and stresses on the cortical bone decreased with increasing cusp inclination.
Resumo:
Purpose:The purpose of this study was to evaluate stress transfer patterns between implant-tooth-connected prostheses comparing rigid and semirigid connectors and internal and external hexagon implants.Materials and Methods:Two models were made of photoelastic resin PL-2, with an internal hexagon implant of 4.00 x 13 mm and another with an external hexagon implant of 4.00 x 13 mm. Three denture designs were fabricated for each implant model, incorporating one type of connection in each one to connect implants and teeth: 1) welded rigid connection; 2) semirigid connection; and 3) rigid connection with occlusal screw. The models were placed in the polariscope, and 100-N axial forces were applied on fixed points on the occlusal surface of the dentures.Results:There was a trend toward less intensity in the stresses on the semirigid connection and solid rigid connection in the model with the external hexagon; among the three types of connections in the model with the internal hexagon implant, the semirigid connection was the most unfavorable one; in the tooth-implant association, it is preferable to use the external hexagon implant.Conclusions:The internal hexagon implant establishes a greater depth of hexagon retention and an increase in the level of denture stability in comparison with the implant with the external hexagon. However, this greater stability of the internal hexagon generated greater stresses in the abutment structures. Therefore, when this association is necessary, it is preferable to use the external hexagon implant.