1000 resultados para cromatografia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synthetic dyes are much used in processed foods. HPLC was applied to different types of snacks, such as colored cereals, chocolate confetti, chewing gums and candies for the determination of those additives. In the case of artificially colored breakfast cereals, 71% of the samples exceeded the allowed limits. Regarding the portions recommended for consumption by the makers of two of the samples, the amounts exceeded those allowed by the Brazilian legislation. In the case of chocolate confetti and candies none of the samples showed higher amounts than those allowed. However 37% of the chewing gum samples presented larger contents than the authorized ones, and one sample contained five times more synthetic dyes than allowed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paclobutrazol is a plant growth retardant which is used world-wide for increasing the yield of cereal crops. However, this compound remains active in the soil for several years and can severely affect the growth and development of subsequent crops, mainly by reducing vegetative vigor. The aim of this work was to develop and validate methods for the determination of paclobutrazol concentrations by both high performance liquid chromatography and spectroscopy. Both methods were satisfactory and showed appropriately low quantification limits. The determination by spectroscopy has, however, the advantage of being a method significantly less expensive than high performance liquid chromatography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comprehensive Multidimensional Chromatography is a relatively new analytic technique, which is receiving growing attention in many parts of the world, including recently in Brazil. This work presents terms in Portuguese which are commonly used in Comprehensive Multidimensional Chromatography in order to help standardize the vocabulary employed in this area in the scientific literature. It also includes some symbols, their nominations, and explanation of some terms, whenever necessary. This proposal does not intend to be comprehensive or definitive; on the contrary, it intends to be a first step in the process of establishing a standardized nomenclature, serving as a base for a further sound discussion in the scientific community realm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pantoprazole is a proton pump inhibitor used in the treatment of digestive ulcers, gastro-esophageal reflux disease and in the eradication of Helicobacter pylori. In this work, an analytical method was developed and validated for the quantification of sodium pantoprazole by HPLC. The method was specific, linear, precise and exact. In order to verify the stability of pantoprazole during dissolution assays, pantoprazole solution in phosphate buffer pH 7.4 was kept at room temperature and protected from light for 22 days. Pantoprazole presented less than 5% of degradation in 6 hours and the half live of the degradation was 124 h.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An HPLC method was validated to assay lamivudine and zidovudine combined in tablets. The chromatographic separation was carried out using methanol and acetate buffer pH 6.5 (50:50 v/v) and a RP-18 column, as mobile and stationary phase, respectively. The UV detection was at 270 nm. The method was linear in the range of 24 - 36 µg/mL (lamivudine) and 48 - 72 µg/mL (zidovudine). The recovery (accuracy) ranged from 101.35% to 103.04% and the precision (repeatability and intermediate precision) was less than 2%. The method can be also applied to the quantification of these drugs in the dissolution test of tablets containing both drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to develop and validate an analytical methodology for simultaneous determination of mebendazole and thiabendazole, two benzimidazoles used as anthelmintics. The method was based on high performance liquid chromatography, using a C18 column, a mobile phase composed of KH2PO4 0.05 mol L-1 and methanol 40:60 (v/v) and UV detection at 312 nm. The results showed that the method presented linearity from 60.0 to 140.0 µg mL-1 for mebendazole and from 99.6 to 232.4 g µL-1 for thiabendazole and it was considered selective, accurate, precise and robust according to the specific resolution from ANVISA, the Brazilian regulatory agency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chromatography is a means of separating mixtures into their several components. TLC, mainly a liquid/solid process, is one of the separation techniques most often used. It is indispensable in laboratories dealing with natural products, organic and analytical chemistry. Commercial chromatography plates are offered at relatively high cost. In this work the construction of a hand-operated plate coater of stationary phases of low cost and good reproducibility is described to be used in teaching laboratories and research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to develop and validate a method of analysis of biodiesel:diesel blends using HRGC-MS in SIM mode. The proposed method is applicable to biodiesel from linoleic oils, such as soybean oil. The following results were obtained: linearity over the methyl linoleate concentration range of 250-2500 mg L-1 (R² > 0.999); limits of detection and quantification of 2 and 5 mg L-1, respectively; recovery from 82 to 96% of biodiesel in diesel and repeatability < 2% (RSD). Comparison between two operators showed that it is not necessary the same operator to do the analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the transesterification of two vegetable oils: soybean and waste frying oil. The main problem of transesterification is related to the measurement of the ethyl ester content. In this work we used a quick analytical method for assessing the ethyl ester fraction of the purified fuel-grade transesterification products by applying a simple correlation with density. If the ester content is higher than 85% by weight the correlation allows the determination by a single density measurement. This method is suitable for control and determines the ethyl ester quickly and simply.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid, sensitive and reliable thin-layer chromatography/spectrophotometry screening procedure was developed for quantitative determination of diuretics associated in pharmaceutical dosage forms. The chromatographic method employed microcrystalline cellulose and butanol : acetic acid : water (4:1:1) or amilic alcohol : ammonium hydroxide 25% (9:1) as mobile phases and detection by U.V. light. The drugs were extracted using a simple procedure and were quantified by U.V. spectrophotometry. Results varied from 97.5 to 102.5% and are similar to those obtained by conventional methods. This method of quantification of diuretics is promising for quality control of drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a simple and practical thermogravimetric method for determining the layer thickness of immobilized polymer stationary phases used in reversed-phase high-performance liquid chromatography. In this method, the weight loss of different polysiloxanes immobilized onto chromatographic supports, determined over the temperature range 150-650 ºC, demonstrated excellent agreement with the sum of carbon and hydrogen content obtained by elemental analysis. The results presented here suggest that the thermogravimetric procedure is an accurate and precise method to determine the polymeric material content on polymer-coated stationary phases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical study based on extraction with methanol-water, immunoaffinity cleanup and separation, identification and quantification of aflatoxin B1 by thin-layer chromatography,in ground black and white pepper and oregano was carried out. Validation of the applied methodology was done through accuracy and precision studies. Recoveries of aflatoxin B1 and relative standard deviations, from spice samples spiked at levels from 4.86 to 97.70 µg/kg, were, respectively, higher than 72% and lower than 20%. Application to spice samples available in Minas Gerais state, purchased at popular markets, showed no contamination with aflatoxin B1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the procedures for analysing pollutant gases emitted by engines, such as volatile organic compounds (benzene, toluene, ethylbenzene, o-xylene, m-xylene and p-xylene) by using high resolution gas chromatography (HRGC). For IC engine burning, in a broad sense, the use of the B10 mixture reduces drastically the emissions of aromatic compounds. Especially for benzene the reduction of concentrations occurs at the level of about 24.5%. Although a concentration value below 1 µg mL-1 has been obtained, this reduction is extremely significant since benzene is a carcinogenic compound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chromatography combined with several different detection systems is one of the more used and better performing analytical tools. Chromatography with tandem mass spectrometric detection gives highly selective and sensitive analyses and permits obtaining structural information about the analites and about their molar masses. Due to these characteristics, this analytical technique is very efficient when used to detect substances at trace levels in complex matrices. In this paper we review instrumental and technical aspects of chromatography-tandem mass spectrometry and the state of the art of the technique as it is applied to analysis of toxic substances in food.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical method has been developed and validated for the quantitation of lamivudine, zidovudine and nevirapine in the fixed-dose combination film-coated tablet by high performance liquid chromatography, in accordance with RE No. 899/2003, National Sanitary Surveillance Agency. It was based on an isocratic elution system with a potassium phosphate buffer pH 3.0: acetonitrile (60:40 v/v) mobile phase, C18, 250 x 46 mm column, 10µm particle size, λ 270 nm. The statistically evaluated results have shown that the method is specific, precise, accurate, and robust, ensuring the analytical safety of 3TC, AZT and NVP determination, which emerges as a new therapeutic alternative for antiretroviral treatment.