956 resultados para concentration time
Resumo:
The objective of this study was to compare the in vitro dissolution profile of a new rapidly absorbed paracetamol tablet containing sodium bicarbonate (PS) with that of a conventional paracetamol tablet (P), and to relate these by deconvolution and mapping to in vivo release. The dissolution methods used include the standard procedure described in the USP monograph for paracetamol tablets, employing buffer at pH5.8 or 0.05 M HCl at stirrer speeds between 10 and 50 rpm. The mapping process was developed and implemented in Microsoft Excel® worksheets that iteratively calculated the optimal values of scale and shape factors which linked in vivo time to in vitro time. The in vitro-in vivo correlation (IVIVC) was carried out simultaneously for both formulations to produce common mapping factors. The USP method, using buffer at pH5.8, demonstrated no difference between the two products. However, using an acidic medium the rate of dissolution of P but not of PS decreased with decreasing stirrer speed. A significant correlation (r=0.773; p<.00001) was established between in vivo release and in vitro dissolution using the profiles obtained with 0.05 M HCl and a stirrer speed of 30 rpm. The scale factor for optimal simultaneous IVIVC in the fasting state was 2.54 and the shape factor was 0.16; corresponding values for mapping in the fed state were 3.37 and 0.13 (implying a larger in vitro-in vivo time difference but reduced shape difference in the fed state). The current IVIVC explains, in part, the observed in vivo variability of the two products. The approach to mapping may also be extended to different batches of these products, to predict the impact of any changes of in vitro dissolution on in vivo release and plasma drug concentration-time profiles.
Resumo:
The taxonomic delimitation at the species level in plants is not an easy task due to the large polymorphism of plants. In this project we aimed to evaluate three morphotypes (forms) of Cryptanthus zonatus (Vis.) Beer ( Bromeliaceae, Bromelioideae ) described in the literature using fl oral biology and phenology, as well as flo ral morphology and leaf anatomy . These studies were conducted in the Parque Estadual das Dunas de Natal, Rio Grande Norte (RN) and Private Reserve of Natural Patrimony Mata Estrela , in the municipality of Ba í a Form osa. The survey of the phenology of the morphotypes involved monthly specimen observation in the field, during one year. In each visit, we observed the status of flowering and fruiting phenophases of the population of the three forms of C. zonatus . For flo ral biology we sought to evaluate data like: observed floral visitors, nectar volume and concentration, time of anthesis and closing of flowers . Flowers of the three fo rms were collected in the field , analyzed by stereomicroscope, and measurements of the f loral pieces were made with the help of a caliper . Transversal and paradermal sections of the leaves of the three forms were stained and then examined under an optical microscope. Observations of the epidermis under scanning electron microscopy were also conducted. The three m orphotypes could not be sepated based on all evidence investigated. Thus, we conclude that there is not evidences to support the recognition of C. zonatus morphotypes as taxonomic entities, and also that the tools of phenology, anatomy, biology and floral morphology were not useful to delimit these three forms . Yet to characterize better the Flora of Bromeli aceae of RN, the leaf anatomy of Orthophytum disjunctum was also studied. Orthophytum is the sister genus to Cryptanthus and only recently documented in the semiarid of RN. The anatomical comparison between Cryptanthus and Orthophytum allowed the separatio n of both genera based on the arrangement of stomata and thickness of aquiferous parênquima . During the fieldwork, it was still possible to document the first occurrence of Aechmea muricata in RN, inside the Mata Estrela preserve, aiding the understanding of the distribution of the taxon that is currently threatened with extinction.
Resumo:
La circulation extracorporelle (CEC) est une technique utilisée en chirurgie cardiaque effectuée des milliers de fois chaque jour à travers le monde. L’instabilité hémodynamique associée au sevrage de la CEC difficile constitue la principale cause de mortalité en chirurgie cardiaque et l’hypertension pulmonaire (HP) a été identifiée comme un des facteurs de risque les plus importants. Récemment, une hypothèse a été émise suggérant que l'administration prophylactique (avant la CEC) de la milrinone par inhalation puisse avoir un effet préventif et faciliter le sevrage de la CEC chez les patients atteints d’HP. Toutefois, cette indication et voie d'administration pour la milrinone n'ont pas encore été approuvées par les organismes réglementaires. Jusqu'à présent, la recherche clinique sur la milrinone inhalée s’est principalement concentrée sur l’efficacité hémodynamique et l'innocuité chez les patients cardiaques, bien qu’aucun biomarqueur n’ait encore été établi. La dose la plus appropriée pour l’administration par nébulisation n'a pas été déterminée, de même que la caractérisation des profils pharmacocinétiques (PK) et pharmacodynamiques (PD) suite à l'inhalation. L'objectif de notre recherche consistait à caractériser la relation exposition-réponse de la milrinone inhalée administrée chez les patients subissant une chirurgie cardiaque sous CEC. Une méthode analytique par chromatographie liquide à haute performance couplée à un détecteur ultraviolet (HPLC-UV) a été optimisée et validée pour le dosage de la milrinone plasmatique suite à l’inhalation et s’est avérée sensible et précise. La limite de quantification (LLOQ) était de 1.25 ng/ml avec des valeurs de précision intra- et inter-dosage moyennes (CV%) <8%. Des patients souffrant d’HP pour lesquels une chirurgie cardiaque sous CEC était prévue ont d’abord été recrutés pour une étude pilote (n=12) et, par la suite, pour une étude à plus grande échelle (n=28) où la milrinone (5 mg) était administrée par inhalation pré-CEC. Dans l'étude pilote, nous avons comparé l'exposition systémique de la milrinone peu après son administration avec un nébuliseur pneumatique ou un nébuliseur à tamis vibrant. L’efficacité des nébuliseurs en termes de dose émise et dose inhalée a également été déterminée in vitro. Dans l'étude à plus grande échelle conduite en utilisant exclusivement le nébuliseur à tamis vibrant, la dose inhalée in vivo a été estimée et le profil pharmacocinétique de la milrinone inhalée a été pleinement caractérisé aux niveaux plasmatique et urinaire. Le ratio de la pression artérielle moyenne sur la pression artérielle pulmonaire moyenne (PAm/PAPm) a été choisi comme biomarqueur PD. La relation exposition-réponse de la milrinone a été caractérisée pendant la période d'inhalation en étudiant la relation entre l'aire sous la courbe de l’effet (ASCE) et l’aire sous la courbe des concentrations plasmatiques (ASC) de chacun des patients. Enfin, le ratio PAm/PAPm a été exploré comme un prédicteur potentiel de sortie de CEC difficile dans un modèle de régression logistique. Les expériences in vitro ont démontré que les doses émises étaient similaires pour les nébuliseurs pneumatique (64%) et à tamis vibrant (68%). Cependant, la dose inhalée était 2-3 fois supérieure (46% vs 17%) avec le nébuliseur à tamis vibrant, et ce, en accord avec les concentrations plasmatiques. Chez les patients, en raison des variations au niveau des facteurs liés au circuit et au ventilateur causant une plus grande dose expirée, la dose inhalée a été estimée inférieure (30%) et cela a été confirmé après récupération de la dose de milrinone dans l'urine 24 h (26%). Les concentrations plasmatiques maximales (Cmax: 41-189 ng/ml) et l'ampleur de la réponse maximale ΔRmax-R0 (0-65%) ont été observées à la fin de l'inhalation (10-30 min). Les données obtenues suite aux analyses PK sont en accord avec les données publiées pour la milrinone intraveineuse. Après la période d'inhalation, les ASCE individuelles étaient directement reliées aux ASC (P=0.045). Enfin, notre biomarqueur PD ainsi que la durée de CEC ont été identifiés comme des prédicteurs significatifs de la sortie de CEC difficile. La comparaison des ASC et ASCE correspondantes a fourni des données préliminaires supportant une preuve de concept pour l'utilisation du ratio PAm/PAPm comme biomarqueur PD prometteur et justifie de futures études PK/PD. Nous avons pu démontrer que la variation du ratio PAm/PAPm en réponse à la milrinone inhalée contribue à la prévention de la sortie de CEC difficile.
Resumo:
La circulation extracorporelle (CEC) est une technique utilisée en chirurgie cardiaque effectuée des milliers de fois chaque jour à travers le monde. L’instabilité hémodynamique associée au sevrage de la CEC difficile constitue la principale cause de mortalité en chirurgie cardiaque et l’hypertension pulmonaire (HP) a été identifiée comme un des facteurs de risque les plus importants. Récemment, une hypothèse a été émise suggérant que l'administration prophylactique (avant la CEC) de la milrinone par inhalation puisse avoir un effet préventif et faciliter le sevrage de la CEC chez les patients atteints d’HP. Toutefois, cette indication et voie d'administration pour la milrinone n'ont pas encore été approuvées par les organismes réglementaires. Jusqu'à présent, la recherche clinique sur la milrinone inhalée s’est principalement concentrée sur l’efficacité hémodynamique et l'innocuité chez les patients cardiaques, bien qu’aucun biomarqueur n’ait encore été établi. La dose la plus appropriée pour l’administration par nébulisation n'a pas été déterminée, de même que la caractérisation des profils pharmacocinétiques (PK) et pharmacodynamiques (PD) suite à l'inhalation. L'objectif de notre recherche consistait à caractériser la relation exposition-réponse de la milrinone inhalée administrée chez les patients subissant une chirurgie cardiaque sous CEC. Une méthode analytique par chromatographie liquide à haute performance couplée à un détecteur ultraviolet (HPLC-UV) a été optimisée et validée pour le dosage de la milrinone plasmatique suite à l’inhalation et s’est avérée sensible et précise. La limite de quantification (LLOQ) était de 1.25 ng/ml avec des valeurs de précision intra- et inter-dosage moyennes (CV%) <8%. Des patients souffrant d’HP pour lesquels une chirurgie cardiaque sous CEC était prévue ont d’abord été recrutés pour une étude pilote (n=12) et, par la suite, pour une étude à plus grande échelle (n=28) où la milrinone (5 mg) était administrée par inhalation pré-CEC. Dans l'étude pilote, nous avons comparé l'exposition systémique de la milrinone peu après son administration avec un nébuliseur pneumatique ou un nébuliseur à tamis vibrant. L’efficacité des nébuliseurs en termes de dose émise et dose inhalée a également été déterminée in vitro. Dans l'étude à plus grande échelle conduite en utilisant exclusivement le nébuliseur à tamis vibrant, la dose inhalée in vivo a été estimée et le profil pharmacocinétique de la milrinone inhalée a été pleinement caractérisé aux niveaux plasmatique et urinaire. Le ratio de la pression artérielle moyenne sur la pression artérielle pulmonaire moyenne (PAm/PAPm) a été choisi comme biomarqueur PD. La relation exposition-réponse de la milrinone a été caractérisée pendant la période d'inhalation en étudiant la relation entre l'aire sous la courbe de l’effet (ASCE) et l’aire sous la courbe des concentrations plasmatiques (ASC) de chacun des patients. Enfin, le ratio PAm/PAPm a été exploré comme un prédicteur potentiel de sortie de CEC difficile dans un modèle de régression logistique. Les expériences in vitro ont démontré que les doses émises étaient similaires pour les nébuliseurs pneumatique (64%) et à tamis vibrant (68%). Cependant, la dose inhalée était 2-3 fois supérieure (46% vs 17%) avec le nébuliseur à tamis vibrant, et ce, en accord avec les concentrations plasmatiques. Chez les patients, en raison des variations au niveau des facteurs liés au circuit et au ventilateur causant une plus grande dose expirée, la dose inhalée a été estimée inférieure (30%) et cela a été confirmé après récupération de la dose de milrinone dans l'urine 24 h (26%). Les concentrations plasmatiques maximales (Cmax: 41-189 ng/ml) et l'ampleur de la réponse maximale ΔRmax-R0 (0-65%) ont été observées à la fin de l'inhalation (10-30 min). Les données obtenues suite aux analyses PK sont en accord avec les données publiées pour la milrinone intraveineuse. Après la période d'inhalation, les ASCE individuelles étaient directement reliées aux ASC (P=0.045). Enfin, notre biomarqueur PD ainsi que la durée de CEC ont été identifiés comme des prédicteurs significatifs de la sortie de CEC difficile. La comparaison des ASC et ASCE correspondantes a fourni des données préliminaires supportant une preuve de concept pour l'utilisation du ratio PAm/PAPm comme biomarqueur PD prometteur et justifie de futures études PK/PD. Nous avons pu démontrer que la variation du ratio PAm/PAPm en réponse à la milrinone inhalée contribue à la prévention de la sortie de CEC difficile.
Resumo:
Tomato (Lycopersicon esculentum Mill.) is the second most important vegetable crop worldwide and a rich source of hydrophilic (H) and lipophilic (L) antioxidants. The H fraction is constituted mainly by ascorbic acid and soluble phenolic compounds, while the L fraction contains carotenoids (mostly lycopene), tocopherols, sterols and lipophilic phenolics [1,2]. To obtain these antioxidants it is necessary to follow appropriate extraction methods and processing conditions. In this regard, this study aimed at determining the optimal extraction conditions for H and L antioxidants from a tomato surplus. A 5-level full factorial design with 4 factors (extraction time (I, 0-20 min), temperature (T, 60-180 •c), ethanol percentage (Et, 0-100%) and solid/liquid ratio (S/L, 5-45 g!L)) was implemented and the response surface methodology used for analysis. Extractions were carried out in a Biotage Initiator Microwave apparatus. The concentration-time response methods of crocin and P-carotene bleaching were applied (using 96-well microplates), since they are suitable in vitro assays to evaluate the antioxidant activity of H and L matrices, respectively [3]. Measurements were carried out at intervals of 3, 5 and 10 min (initiation, propagation and asymptotic phases), during a time frame of 200 min. The parameters Pm (maximum protected substrate) and V m (amount of protected substrate per g of extract) and the so called IC50 were used to quantify the response. The optimum extraction conditions were as follows: r~2.25 min, 7'=149.2 •c, Et=99.1 %and SIL=l5.0 giL for H antioxidants; and t=l5.4 min, 7'=60.0 •c, Et=33.0% and S/L~l5.0 g/L for L antioxidants. The proposed model was validated based on the high values of the adjusted coefficient of determination (R2.wi>0.91) and on the non-siguificant differences between predicted and experimental values. It was also found that the antioxidant capacity of the H fraction was much higher than the L one.
Resumo:
Tomato is the second most important vegetable crop worldwide and a rich source of industrially interesting antioxidants. Hence, the microwave-assisted extraction of hydrophilic (H) and lipophilic (L) antioxidants from a surplus tomato crop was optimized using response surface methodology. The relevant independent variables were temperature (T), extraction time (t), ethanol concentration (Et) and solid/liquid ratio (S/L). The concentration-time response methods of crocin and β-carotene bleaching were applied, since they are suitable in vitro assays to evaluate the antioxidant activity of H and L matrices, respectively. The optimum operating conditions that maximized the extraction were as follows: t, 2.25 min; T, 149.2 ºC; Et, 99.1 %; and S/L, 45.0 g/L for H antioxidants; and t, 15.4 min; T, 60.0 ºC; Et, 33.0 %; and S/L, 15.0 g/L for L antioxidants. This industrial approach indicated that surplus tomatoes possess a high content of antioxidants, offering an alternative source for obtaining natural value-added compounds. Additionally, by testing the relationship between the polarity of the extraction solvent and the antioxidant activity of the extracts in H and L media (polarity-activity relationship), useful information for the study of complex natural extracts containing components with variable degrees of polarity was obtained.
Resumo:
The aim of this study was to determine the pharmacokinetic parameters of liposomal ropivacaine after dental anesthesia in 14 healthy volunteers. In this randomized, double-blind and crossover study, the volunteers received maxillary infiltration of liposome-encapsulated 0.5% ropivacaine and, 0.5% ropivacaine with 1:200,000 epinephrine in two different sessions. Blood samples were collected before and after (from 15 to 1440 min) the administration of either ropivacaine formulation. HPLC with UV detection was used to quantify plasma ropivacaine concentrations. The pharmacokinetic parameters AUC(0-24) (area under the plasma concentration x time curve from baseline to 24 h), AUC(0-infinity) (area under the plasma concentration-time curve from baseline to infinity), C-max (maximum drug concentration), CL (renal clearance), T-max (maximum drug concentration time), t(1/2) (elimination half-life) and Vd (volume of distribution) were analyzed using the Wilcoxon signed-rank test. No differences (p > 0.05) were observed between both formulations for any of the pharmacokinetic parameters evaluated and plasma ropivacaine concentrations, considering each period of time. Both formulations showed similar pharmacokinetic profiles, indicating that the liposomal formulation could be a safer option for use of this local anesthetic, due to the absence of a vasoconstrictor.
Resumo:
El blanqueamiento dental es un proceso dinámico que busca la eliminación de manchas de la estructura dental mediante el empleo de productos químicos, principalmente el peróxido de hidrógeno, el cual fue utilizado por primera vez en 1884 y hasta la fecha continúa siendo el principal componente activo de muchos productos usados para terapias de blanqueamiento dental, y es utilizado en su forma pura o como producto final de la degradación de otras sustancias empleadas para blanqueamiento, como el peróxido de carbamida. Al entrar en contacto con los tejidos dentales el peróxido de hidrógeno se disocia en radicales libres, como las especies reactivas de oxígeno, las cuales pueden difundirse a través de esmalte, dentina e incluso llegar al tejido pulpar, provocando efectos adversos como son sensibilidad dental, daño a los componentes celulares y alteración del flujo sanguíneo; estos efectos deletéreos están relacionados con el número de sesiones, concentración del producto, tiempo de colocación y el tipo de activación (química, luz, calor y láser).
Resumo:
Purpose: To evaluate the anti-vibrio potentials of acetone and aqueous leaf extracts of Ocimum gratissimum and determine its relevance in the treatment of vibrios infection. Methods: The agar-well diffusion method was used for screening the extracts for their anti-vibrio activity. Broth micro-dilution assay was used to determine the minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) of the extracts. Time-kill assay was used to assess bactericidal and/or bacteriostatic activity. Results: The acetone extract showed activity against 47.5 % (19/40) of the test bacteria, while the aqueous extract had activity against 30 % (12/40). MIC and MBC values range for the acetone extract were 0.625 – 5.0 mg/mL and 2.5 – 10 mg/mL respectively. The range of MIC exhibited by the antibiotic (gentamicin) against the vibrios is 0.002 mg/mL and >0.256 mg/mL. Significant reduction in the bacterial density was at 2 × MIC after a 4 h interaction period, while bacterial density after 6 and 8 h interactions with extract was highly bactericidal. Growth inhibition and efficacy of the crude acetone extract were observed to be both concentration- and time-dependent. Conclusion: The bacteriostatic and bactericidal activities observed for Ocimum gratissimum leaf suggest that the plant is a potential source of bioactive components that may be effective in the treatment of vibrios infections.
Resumo:
Purpose: To compare oral bioavailability and pharmacokinetic parameters of different lornoxicam formulations and to assess similarity in plasma level profiles by statistical techniques. Methods: An open-label, two-period crossover trial was followed in 24 healthy Pakistani volunteers (22 males, 2 females). Each participant received a single dose of lornoxicam controlled release (CR) microparticles and two doses (morning and evening) of conventional lornoxicam immediate release (IR) tablet formulation. The microparticles were prepared by spray drying method. The formulations were administered again in an alternate manner after a washout period of one week. Pharmacokinetic parameters were determined by Kinetica 4.0 software using plasma concentration-time data. Moreover, data were statistically analyzed at 90 % confidence interval (CI) and Schuirmann’s two one-sided t-test procedure. Results: Peak plasma concentration (Cmax) was 20.2 % lower for CR formulation compared to IR formulation (270.90 ng/ml vs 339.44 ng/ml, respectively) while time taken to attain Cmax (tmax) was 5.25 and 2.08 h, respectively. Area under the plasma drug level versus time (AUC) curve was comparable for both CR and IR formulations. The 90 % confidence interval (CI) values computed for Cmax, AUC0-24, and AUC0-∞ , after log transformation, were 87.21, 108.51 and 102.74 %, respectively, and were within predefined bioequivalence range (80 - 125 %). Conclusion: The findings suggest that CR formulation of lornoxicam did not change the overall pharmacokinetic properties of lornoxicam in terms of extent and rate of lornoxicam absorption.
Resumo:
El objetivo de este estudio es evaluar la eficacia de los tratamientos más utilizados en infecciones odontogénicas en niños y adolescentes aplicando criterios farmacocinéticos/farmacodinámicos (PK/PD). Se han simulado las curvas de concentración plasmática libre-tiempo a partir de parámetros farmacocinéticos medios de amoxicilina, amoxicilina-ácido clavulánico, cefuroxima axetilo, espiramicina, clindamicina, azitromicina y metronidazol. Para los antibióticos con actividad dependiente del tiempo, se ha calculado el tiempo durante el cual las concentraciones permanecen por encima de la concentración inhibitoria mínima (CIM90) de los microorganismos (T>CIM). Para los antimicrobianos con actividad dependiente de la concentración, se ha calculado el cociente entre el área bajo la curva y la CIM90 (ABC/CIM90). Con amoxicilina-ácido clavulánico (80 mg/kg/día) se han obtenido índices de eficacia adecuados frente a los microorganismos estudiados (T > CIM > 40%), excepto paraVeillonella spp. Clindamicina (40 mg/kg/día) también ha presentado índices PK/PD adecuados frente a la mayoría de los patógenos, excepto Lactobacillus, Actinobacillus actinomycetemcomitans, Peptostreptococcus resistente a penicilina y Eikenella corrodens. Con dosis altas de amoxicilina los resultados no han sido satisfactorios frente a varias especies bacterianas. Con azitromicina y metronidazol no se han alcanzado valores adecuados frente a la mayoría de patógenos (ABC/CIM90 < 25). En conclusión, el tratamiento empírico más adecuado en infecciones odontogénicas en niños y adolescentes es amoxicilina-ácido clavulánico en altas dosis de amoxicilina, aunque se puede utilizar como alternativa clindamicina. Sería conveniente confirmar estos resultados mediante ensayos clínicos, para cuyo diseño y evaluación podría ser de gran utilidad la aplicación de estudios PK/PD.
Resumo:
Understanding mixture formation phenomena during the first few cycles of an engine cold start is extremely important for achieving the minimum engine-out emission levels at the time when the catalytic converter is not yet operational. Of special importance is the structure of the charge (film, droplets and vapour) which enters the cylinder during this time interval as well as its concentration profile. However, direct experimental studies of the fuel behaviour in the inlet port have so far been less than fully successful due to the brevity of the process and lack of a suitable experimental technique. We present measurements of the hydrocarbon (HC) concentration in the manifold and port of a production SI engine using the Fast Response Flame Ionisation Detector (FRFID). It has been widely reported in the past few years how the FRFID can be used to study the exhaust and in-cylinder HC concentrations with a time resolution of a few degrees of crank angle, and the device has contributed significantly to the understanding of unburned HC emissions. Using the FRFID in the inlet manifold is difficult because of the presence of liquid droplets, and the low and fluctuating pressure levels, which leads to significant changes in the response time of the instrument. However, using recently developed procedures to correct for the errors caused by these effects, the concentration at the sampling point can be reconstructed to align the FRFID signal with actual events in the engine. © 1996 Society of Automotive Engineers, Inc.
Resumo:
The interaction of chlorpromazine (CPZ) with supported bilaver lipid (dipalmitoyphosphatidylcholine) membrane (s-BLM) on the glassy carbon electrode (GCE) was investigated using cyclic voltammetry and ac impedance spectroscopy. The experimental data, based on the voltammetric response of Ru(NH3)(6)(3+) associated with the oxidation of CPZ on the electrode, indicated that the interaction of CPZ with s-BLM was concentration and time dependant. The interaction between them could be divided into three stages by the concentration of CPZ: low, middle and high concentration. At the first stage, s-BLM was not affected by CPZ and the interaction was only a penetration of a small quantity of CPZ molecule into s-BLM. At the second stage, the defects formed in s-BLM due to the penetration of more CPZ molecule into s-BLM. At the last stage, a high CPZ:lipid ratio reached in s-BLM, resulting in the solubilization of s-BLM. The interaction time had different effect at three stages.