188 resultados para chromatograph


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Here, we present a method for measuring barbiturates (butalbital, secobarbital, pentobarbital, and phenobarbital) in whole blood samples. To accomplish these measurements, analytes were extracted by means of hollow-fiber liquid-phase microextraction in the three-phase mode. Hollow-fiber pores were filled with decanol, and a solution of sodium hydroxide (pH 13) was introduced into the lumen of the fiber (acceptor phase). The fiber was submersed in the acidified blood sample, and the system was subjected to an ultrasonic bath. After a 5 min extraction, the acceptor phase was withdrawn from the fiber and dried under a nitrogen stream. The residue was reconstituted with ethyl acetate and trimethylanilinium hydroxide. An aliquot of 1.0 mu L of this solution was injected into the gas chromatograph/mass spectrometer, with the derivatization reaction occurring in the hot injector port (flash methylation). The method proved to be simple and rapid, and only a small amount of organic solvent (decanol) was needed for extraction. The detection limit was 0.5 mu g/mL for all the analyzed barbiturates. The calibration curves were linear over the specified range (1.0 to 10.0 mu g/mL). This method was successfully applied to postmortem samples (heart blood and femoral blood) collected from three deceased persons previously exposed to barbiturates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study of organic pollution in estuaries is very relevant as they are transitional zones, which control the fluxes of water, nutrients, particles and organisms from and to the continental margins, rivers and oceans. The aims of this study are:(1) to evaluate organic pollution in coastal sediments of Montevideo, Río de la Plata Estuary by a multi-biomarker approach, (2) to identify major sources of organic pollutants through qualitative analysis using molecular indices, (3) to assess the relative contribution of different sources of hydrocarbons through quantitative source apportionment employing (PCA/MLR) as chemometric technique. Sampling surveys were carried out in July 2009, January 2010 and March 2011 in 37 stations along the middle portion of the Río de la Plata Estuary across the coast of Montevideo. In each station surface (0–2 cm depth) sediment samples were taken with a 0.05 m2 van Veen grab. The Soxhlet extracted organic compounds included aliphatic hydrocarbons (AHs) and steroids, analysed by gas chromatograph with flame ionization detector (GC-FID), linear alkylbenzenes (LABs) and polycyclic aromatic hydrocarbons (PAHs) quantified by gas chromatograph with mass spectrometer (GC/MS). All biomarkers presented the highest concentrations in the stations of Montevideo Bay indicating high levels of organic pollution. The combination of molecular indices and the chemometric technique showed that major sources of AHs and PAHs are petroleum inputs and combustion, due to oil transport and refinement, harbour activities and vehicular emissions.Major sources of LABs and steroids are urban and domestic sewage. Identification, quantification and source assignment of those organic compounds are very important to assess pollution and to give tools to help minimize the inputs into the environment

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Im Rahmen der Projekte CARIBIC ('Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrument Container') und INDOEX ('Indian Ocean Experi-ment') wurde ein Gaschromatograph mit Massenspektrometer zur Analyse von Luftproben auf Nicht-Methan-Kohlenwasserstoffe (NMKW) im ppb- und ppt-Bereich entwickelt. Während INDOEX erfolgte die Probennahme auf dem Forschungsschiff Ronald Brown, während CARIBIC mit einem automatischen Probensammler an Bord eines Passagierflugzeuges (Boeing 767-ER, LTU). Die NMKW-Meßergebnisse wurden zusammen mit Ergebnissen von Mes-sungen von Kohlenmonoxid (CO, einschließlich Isotopenzusam-mensetzung), Ozon (O3), Methan (CH4), Kohlendioxid (CO2), Distickstoffmonoxid (N2O), Schwefelhexafluorid (SF6) und Aerosoleigenschaften sowie meteorologischen Daten inter-pretiert. Während INDOEX (Februar / März 1999) wurde in der maritimen Grenzschicht (MBL) des Indischen Ozeans (IO) eine starke Variabilität diverser Spurengase beobachtet, die teilweise durch regionale Emissionen hervorgerufen wurde, die stärkste Variabilität war jedoch durch Langstrecken-transport aus mittleren Breiten der Nordhemisphäre bedingt. Aufgrund der Abweichungen vom klimatologischen Mittel, sollten regionale Quellen die MBL des IO im allgemeinen stärker beeinflussen. Die Einteilung des IO in meteorologi-sche Luftmassenregime wurde bestätigt. Starke Spurengasgra-dienten an der innertropischen Konvergenzzone (ITCZ) zeigen, daß die ITCZ in erster Linie den Austausch von Luftmassen zwischen den Hemisphären behindert. Bei CARIBIC werden Messungen von Spurengasen (ein-(schließlich NMKW) und Aerosoleigenschaften auf Flügen in der oberen Troposphäre / unteren Stratosphäre durchgeführt. Während eines Flug über Afrika wurden der Einfluß von durch Konvektion in die obere Troposphäre eingebrachten, frischen Abgasen aus Biomassenverbrennung nachgewiesen. Andere Luft-massen wurden durch Emissionen von Erdgas bzw. durch die Stratosphäre beeinflußt.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Deutsch:Schwerpunkt dieser Arbeit war die Entwicklung einer Methode zur Spurenbestimmung von Silicium in organischen und anorganischen Matrices unter Verwendung der massenspektrometrischen Isotopenverdünnungsanalyse (MSIVA) an einem hochauflösenden induktiv gekoppelten Plasma-Massenspektrometer (HR-ICP-MS). Zusätzlich zur Elementspurenbestimmung wurde eine GC/HR-ICP-MS Kopplung entwickelt, die zur Analyse linearer und cyclischer Siloxane verwendet wurde.Die hier entwickelte Analysenmethode erlaubt Nachweisgrenzen für Silicium sowohl in organischen als auch in anorganischen Matrices im oberen ng/g-Bereich und ergab für die im Rahmen dieser Arbeit analysierten Proben Reproduzierbarkeiten von < 20%. Durch einfache Verdünnung nach der Probenvorbereitung in Verbindung mit dem sehr empfindlichen Detektionsverfahren sowie der internen Standardisierung mittels MSIVA erlaubt das Verfahren eine präzise Bestimmung von Silicium in jeglicher Matrix. Neben der Schnelligkeit und Einfachheit eignet sich die hier entwickelte Methode besonders für die Routineanalytik. Die gute Reproduzierbarkeit und der Vergleich mit Ergebnissen von zwei Interlaborstudien unterstreicht zusätzlich die Fähigkeit präzise und richtige Ergebnisse zur Zertifizierung an Standardreferenzmaterialien bezüglich des Siliciums im Spurenbereich zu liefern.Neben dem Gesamtgehalt von Silicium konnten medizinisch relevante Siliciumverbindungen analysiert und quantifiziert werden. Hierbei wurden niedermolekulare Polydimethlysiloxane (PDMS) untersucht, die als Nebenprodukte vor allem in Brustimplantaten auftreten. Grundlage für die Bestimmung dieser Siliciumspezies ist die Kopplung eines hochauflösenden ICP-MS an einen Gaschromatographen. Der hohe Ionisierungsgrad des ICP, gerade unter trockenen Plasmabedingungen, und der elementspezifische und sehr empfindliche massenspektrometrische Detektor erlauben in Verbindung mit dem GC die Bestimmung von Siloxanen bis in den pg/g-Bereich. Aus der Bestimmung des Gesamtgehalts an Silicium und der Bestimmung des Gehalts an den untersuchten Siliciumverbindungen können Vergleiche gemacht werden. Die Analyse beider Parameter ist mit Hilfe in dieser Arbeit entwickelten Methode möglich.Zusätzlich zur Siliciumbestimmung wurde der Gehalt an Platin in Humanproben analysiert, da bei der Herstellung der Füllung von Siliconimplantaten Platinkatalysatoren verwendet werden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Volatile organic compounds play a critical role in ozone formation and drive the chemistry of the atmosphere, together with OH radicals. The simplest volatile organic compound methane is a climatologically important greenhouse gas, and plays a key role in regulating water vapour in the stratosphere and hydroxyl radicals in the troposphere. The OH radical is the most important atmospheric oxidant and knowledge of the atmospheric OH sink, together with the OH source and ambient OH concentrations is essential for understanding the oxidative capacity of the atmosphere. Oceanic emission and / or uptake of methanol, acetone, acetaldehyde, isoprene and dimethyl sulphide (DMS) was characterized as a function of photosynthetically active radiation (PAR) and a suite of biological parameters, in a mesocosm experiment conducted in the Norwegian fjord. High frequency (ca. 1 minute-1) methane measurements were performed using a gas chromatograph - flame ionization detector (GC-FID) in the boreal forests of Finland and the tropical forests of Suriname. A new on-line method (Comparative Reactivity Method - CRM) was developed to directly measure the total OH reactivity (sink) of ambient air. It was observed that under conditions of high biological activity and a PAR of ~ 450 μmol photons m-2 s-1, the ocean acted as a net source of acetone. However, if either of these criteria was not fulfilled then the ocean acted as a net sink of acetone. This new insight into the biogeochemical cycling of acetone at the ocean-air interface has helped to resolve discrepancies from earlier works such as Jacob et al. (2002) who reported the ocean to be a net acetone source (27 Tg yr-1) and Marandino et al. (2005) who reported the ocean to be a net sink of acetone (- 48 Tg yr-1). The ocean acted as net source of isoprene, DMS and acetaldehyde but net sink of methanol. Based on these findings, it is recommended that compound specific PAR and biological dependency be used for estimating the influence of the global ocean on atmospheric VOC budgets. Methane was observed to accumulate within the nocturnal boundary layer, clearly indicating emissions from the forest ecosystems. There was a remarkable similarity in the time series of the boreal and tropical forest ecosystem. The average of the median mixing ratios during a typical diel cycle were 1.83 μmol mol-1 and 1.74 μmol mol-1 for the boreal forest ecosystem and tropical forest ecosystem respectively. A flux value of (3.62 ± 0.87) x 1011 molecules cm-2 s-1 (or 45.5 ± 11 Tg CH4 yr-1 for global boreal forest area) was derived, which highlights the importance of the boreal forest ecosystem for the global budget of methane (~ 600 Tg yr-1). The newly developed CRM technique has a dynamic range of ~ 4 s-1 to 300 s-1 and accuracy of ± 25 %. The system has been tested and calibrated with several single and mixed hydrocarbon standards showing excellent linearity and accountability with the reactivity of the standards. Field tests at an urban and forest site illustrate the promise of the new method. The results from this study have improved current understanding about VOC emissions and uptake from ocean and forest ecosystems. Moreover, a new technique for directly measuring the total OH reactivity of ambient air has been developed and validated, which will be a valuable addition to the existing suite of atmospheric measurement techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the development of micro systems, there is an increasing demand for integrable porous materials. In addition to those conventional applications, such as filtration, wicking, and insulating, many new micro devices, including micro reactors, sensors, actuators, and optical components, can benefit from porous materials. Conventional porous materials, such as ceramics and polymers, however, cannot meet the challenges posed by micro systems, due to their incompatibility with standard micro-fabrication processes. In an effort to produce porous materials that can be used in micro systems, porous silicon (PS) generated by anodization of single crystalline silicon has been investigated. In this work, the PS formation process has been extensively studied and characterized as a function of substrate type, crystal orientation, doping concentration, current density and surfactant concentration and type. Anodization conditions have been optimized for producing very thick porous silicon layers with uniform pore size, and for obtaining ideal pore morphologies. Three different types of porous silicon materials: meso porous silicon, macro porous silicon with straight pores, and macro porous silicon with tortuous pores, have been successfully produced. Regular pore arrays with controllable pore size in the range of 2µm to 6µm have been demonstrated as well. Localized PS formation has been achieved by using oxide/nitride/polysilicon stack as masking materials, which can withstand anodization in hydrofluoric acid up to twenty hours. A special etching cell with electrolytic liquid backside contact along with two process flows has been developed to enable the fabrication of thick macro porous silicon membranes with though wafer pores. For device assembly, Si-Au and In-Au bonding technologies have been developed. Very low bonding temperature (~200 degrees C) and thick/soft bonding layers (~6µm) have been achieved by In-Au bondi ng technology, which is able to compensate the potentially rough surface on the porous silicon sample without introducing significant thermal stress. The application of the porous silicon material in micro systems has been demonstrated in a micro gas chromatograph system by two indispensable components: an integrated vapor source and an inlet filter, wherein porous silicon performs the basic functions of porous media: wicking and filtration. By utilizing a macro porous silicon wick, the calibration vapor source was able to produce a uniform and repeatable vapor generation for n-decane with less than a 0.1% variation in 9 hours, and less than a 0.5% variation in rate over 7 days. With engineered porous silicon membranes the inlet filter was able to show a depth filtration with nearly 100% collection efficiency for particles larger than 0.3µm in diameter, a low pressure-drop of 523Pa at 20sccm flow rate, and a filter capacity of 500µg/cm2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mismatching of alveolar ventilation and perfusion (VA/Q) is the major determinant of impaired gas exchange. The gold standard for measuring VA/Q distributions is based on measurements of the elimination and retention of infused inert gases. Conventional multiple inert gas elimination technique (MIGET) uses gas chromatography (GC) to measure the inert gas partial pressures, which requires tonometry of blood samples with a gas that can then be injected into the chromatograph. The method is laborious and requires meticulous care. A new technique based on micropore membrane inlet mass spectrometry (MMIMS) facilitates the handling of blood and gas samples and provides nearly real-time analysis. In this study we compared MIGET by GC and MMIMS in 10 piglets: 1) 3 with healthy lungs; 2) 4 with oleic acid injury; and 3) 3 with isolated left lower lobe ventilation. The different protocols ensured a large range of normal and abnormal VA/Q distributions. Eight inert gases (SF6, krypton, ethane, cyclopropane, desflurane, enflurane, diethyl ether, and acetone) were infused; six of these gases were measured with MMIMS, and six were measured with GC. We found close agreement of retention and excretion of the gases and the constructed VA/Q distributions between GC and MMIMS, and predicted PaO2 from both methods compared well with measured PaO2. VA/Q by GC produced more widely dispersed modes than MMIMS, explained in part by differences in the algorithms used to calculate VA/Q distributions. In conclusion, MMIMS enables faster measurement of VA/Q, is less demanding than GC, and produces comparable results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Indoor and ambient air organic pollutants have been gaining attention because they have been measured at levels with possible health effects. Studies have shown that most airborne polychlorinated biphenyls (PCBs), pesticides and many polycyclic aromatic hydrocarbons (PAHs) are present in the free vapor state. The purpose of this research was to extend recent investigative work with polyurethane foam (PUF) as a collection medium for semivolatile compounds. Open-porous flexible PUFs with different chemical makeup and physical properties were evaluated as to their collection affinities/efficiencies for various classes of compounds and the degree of sample recovery. Filtered air samples were pulled through plugs of PUF spiked with various semivolatiles under different simulated environmental conditions (temperature and humidity), and sampling parameters (flow rate and sample volume) in order to measure their effects on sample breakthrough volume (V(,B)). PUF was also evaluated in the passive mode using organo-phosphorus pesticides. Another major goal was to improve the overall analytical methodology; PUF is inexpensive, easy to handle in the field and has excellent airflow characteristics (low pressure drop). It was confirmed that the PUF collection apparatus behaves as if it were a gas-solid chromatographic system, in that, (V(,B)) was related to temperature and sample volume. Breakthrough volumes were essentially the same using both polyether and polyester type PUF. Also, little change was observed in the V(,B)s after coating PUF with common chromatographic liquid phases. Open cell (reticulated) foams gave better recoveries than closed cell foams. There was a slight increase in (V(,B)) with an increase in the number of cells/pores per inch. The high-density polyester PUF was found to be an excellent passive and active collection adsorbent. Good recoveries could be obtained using just solvent elution. A gas chromatograph equipped with a photoionization detector gave excellent sensitivities and selectivities for the various classes of compounds investigated. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The non-Hodgkin's B cell lymphomas are a diverse group of neoplastic diseases. The incidence rate of the malignant tumors has been rising rapidly over the past twenty years in the United States and worldwide. The lack of insight to pathogenesis of the disease poses a significant problem in the early detection and effective treatment of the human malignancies. These studies attempted to investigate the molecular basis of pathogenesis of the human high grade B cell non-Hodgkin's lymphomas with a reverse genetic approach. The specific objective was to clone gene(s) which may play roles in development and progression of human high grade B cell non-Hodgkin's lymphomas.^ The messenger RNAs from two high grade B cell lymphoma lines, CJ and RR, were used for construction of cDNA libraries. Differential screening of the derived cDNA libraries yielded a 1.4 kb cDNA clone. The gene, designated as NHL-B1.4, was shown to be highly amplified and over-expressed in the high grade B cell lymphoma lines. It was not expressed in the peripheral blood lymphoid cells from normal donors. However, it was inducible in peripheral blood T lymphocytes by a T cell mitogen, PHA, but could not be activated in normal B cells by B cell mitogen PMA. Further molecular characterization revealed that the gene may have been rearranged in the RR and some other B cell lymphoma lines. The coding capacity of the cDNA has been confirmed by a rabbit reticulocyte lysate and wheat germ protein synthesis system. A recombinant protein with a molecular weight of approximate 30 kDa was visualized in autoradiogram. Polyclonal antisera have been generated by immunization of two rabbits with the NHL-B1.4 recombinant protein produced in the E. coli JM109. The derived antibody can recognize a natural protein with molecular weight of 49 kDa in cell lysate of activated peripheral T lymphocytes of normal donors and both the cell lysate and supernatant of RR B cell lymphoma lines. The possible biologic functions of the molecule has been tested preliminarily in a B lymphocyte proliferation assay. It was found that the Q-sepharose chromatograph purified supernatant of COS cell transfection could increase tritiated thymidine uptake by B lymphocytes but not by T lymphocytes. The B cell stimulatory activity of the supernatant of COS cell tranfection could be neutralized by the polyclonal antisera, indicating that the NHL-B1.4 gene product may be a molecule with BCGF-like activity.^ The expression profiles of NHL-B1.4 in normal and neoplastic lymphoid cells were consistent with the current B lymphocyte activation model and autocrine hypothesis of high grade B cell lymphomagenesis. These results suggested that the NHL-B1.4 cDNA may be a disease-related gene of human high grade B cell lymphomas, which may codes for a postulated B cell autocrine growth factor. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

On DSDP Leg 84, gas hydrates were found at three sites (565, 568, and 570) and were inferred, on the basis of inorganic and organic geochemical evidence, to be present at two sites (566 and 569); no evidence for gas hydrates was observed at Site 567. Recovered gas hydrates appeared as solid pieces of white, icelike material occupying fractures in mudstone or as coarse-grained sediment in which the pore space exhibited rapid outgassing. Also a 1.05-m-long core of massive gas hydrate was obtained at Site 570. Downhole logging indicated that this hydrate was actually 3 to 4 m thick. Measurements of the amount of methane released during the decomposition of these recovered samples clearly showed that gas hydrates had been found. The distribution of evolved hydrocarbon gases indicated that Structure I gas hydrates were present because of the apparent inclusion of methane and ethane and exclusion of propane and higher molecular weight gases. The water composing the gas hydrates was fresh, having chlorinities ranging from 0.5 to 3.2 per mil. At Sites 565, 568, and 570, where gas hydrates were observed, the chlorinity of pore water squeezed from the sediment decreased with sediment depth. The chlorinity profiles may indicate that gas hydrates can often occur finely dispersed in sediments but that these gas hydrates are not recovered because they do not survive the drilling and recovery process. Methane in the gas hydrates found on Leg 84 was mainly derived in situ by biogenic processes, whereas the accompanying small amounts of ethane likely resulted from low-temperature diagenetic processes. Finding gas hydrates on Leg 84 expands observations made earlier on Leg 66 and particularly Leg 67. The results of all of these legs show that gas hydrates are common in landward slope sediments of the Middle American Trench from Mexico to Costa Rica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Selected core samples from the California Continental Borderland (Sites 467-469) were analyzed to evaluate the nature and composition of the lipids and kerogens in terms of their genetic origin and geological maturity. The lipids were of a multiple origin. On the basis of the homolog distributions of the n-alkanes and n-fatty acids, with the shape and magnitude of the unresolved branched and cyclic hydrocarbons, and the structural and stereochemical compositions of the molecular markers, these lipids were derived from primary autochthonous marine (microbial), from allochthonous terrigenous (higher plant wax), and from recycled (geologically mature organic matter) sources. The kerogens were composed of principally marine microbial detritus with a minor input of allochthonous terrestrial material. For the most part, the samples had undergone a thermal maturation according to a normal geothermal gradient, except in the proximity of intrusives. Such additional thermal stress was evident for the samples from Site 469 and to some extent for Site 467 at about a sub-bottom depth of 700 to 800 meters.