954 resultados para Wall Shear Stress


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reviews the methods, benefits and challenges associated with the adoption and translation of computational fluid dynamics (CFD) modelling within cardiovascular medicine. CFD, a specialist area of mathematics and a branch of fluid mechanics, is used routinely in a diverse range of safety-critical engineering systems, which increasingly is being applied to the cardiovascular system. By facilitating rapid, economical, low-risk prototyping, CFD modelling has already revolutionised research and development of devices such as stents, valve prostheses, and ventricular assist devices. Combined with cardiovascular imaging, CFD simulation enables detailed characterisation of complex physiological pressure and flow fields and the computation of metrics which cannot be directly measured, for example, wall shear stress. CFD models are now being translated into clinical tools for physicians to use across the spectrum of coronary, valvular, congenital, myocardial and peripheral vascular diseases. CFD modelling is apposite for minimally-invasive patient assessment. Patient-specific (incorporating data unique to the individual) and multi-scale (combining models of different length- and time-scales) modelling enables individualised risk prediction and virtual treatment planning. This represents a significant departure from traditional dependence upon registry-based, population-averaged data. Model integration is progressively moving towards 'digital patient' or 'virtual physiological human' representations. When combined with population-scale numerical models, these models have the potential to reduce the cost, time and risk associated with clinical trials. The adoption of CFD modelling signals a new era in cardiovascular medicine. While potentially highly beneficial, a number of academic and commercial groups are addressing the associated methodological, regulatory, education- and service-related challenges.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Carotid atherosclerotic disease is highly related to cerebrovascular events. Carotid endarterectomy is the common operation method to treat this disease. In this study, hemodynamics analyses are performed on the carotid arteries in three patients, whose right carotid artery had been treated by carotid endarterectomy and the left carotid artery remained untreated. Flow and loading conditions are compared between these treated and untreated carotid arteries and evaluation of the operative results is discussed. Patient-specific models are reconstructed from MDCT data. Intraoperative ultrasound flow measurements are performed on the treated carotid arteries and the obtained data are used as the boundary conditions of the models and the validations of the computational results. Finite volume method is employed to solve the transport equations and the flow and loading conditions of the models are reported. The results indicate that: (i) in two of the three patients, the internal-to-external flow rate ratio in the untreated carotid artery is larger than that in the treated one, and the average overall flow split ratio by summing up the data of both the left and right carotid arteries is about 2.15; (ii) in the carotid bulb, high wall shear stress occurs at the bifurcation near the external carotid artery in all of the cases without hard plaques; (iii) the operated arteries present low time-averaged wall shear stress at the carotid bulb, especially for the treated arteries with patch technique, indicating the possibility of the recurrence of stenosis; (iv) high temporal gradient of wall shear stress (>35 Pa/s) is shown in the narrowing regions along the vessels; and (v) in the carotid arteries without serious stenosis, the maximum velocity magnitude during mid-diastole is 32~37% of that at systolic peak, however, in the carotid artery with 50% stenosis by hard plaques, this value is nearly doubled (64%). The computational work quantifies flow and loading distributions in the treated and untreated carotid arteries of the same patient, contributing to evaluation of the operative results and indicating the recurrent sites of potential atheromatous plaques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this work is to analyze the local hem odynamic changes caused in a coronary bifurcation by three different stenting techniques: simple stenting of the main vessel, simple stenting of the main vessel with kissing balloon in the side branch and culotte. To carry out this study an idealized geometry of a coronary bifurcation is used, and two bifurcation angles, 45º and 90º, are chosen as representative of the wide variety of re al configurations. In order to quantify the influence of the stenting technique on the local blood flow, both numeri- cal simulations and experimental measurements are performed. First, steady simulations are carried out with the commercial code ANSYS-Fluent, and then, experimental measurements with PIV (Particle Image Velocimetry) obtained in the laboratory are used to validate the numerical simulation. The steady computational simulations show a good overall agreement with the experimental data. Second, pulsatile flow is considered to take into account the tran- sient effects. The time averaged wall shear stress, scillatory shear index and pressure drop obtained numerically are used to compare the behavior of the stenting techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abnormalities of the aortic arch, as the most proximal site of the cardiovascular system, are of great interest due to its major role in blood distribution to all downstream members. Wall dissection is one of the disorders that an aorta may suffer due to hypertension or degradation of aortic wall properties. A geometrical change of the aortic arch caused by the dissected wall, and consequently the blood flow path, makes the time-varying flow curves to be different in comparison to the healthy aortic arch. This phenomenon modifies wall shear stress (WSS) history during the cardiac cycle. In the current work, the pulsatile blood flow in a typical Stanford A (DeBakey II) dissected aorta is simulated by CFD technique, STAR-CCM+. The boundary conditions are calculated based on a combination of the impedance boundary condition and the auto-regulation concept in the cardiovascular system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Las enfermedades arteriales vienen presididas por la aterosclerosis, que es un proceso crónico de degeneración, que evoluciona hacia la obstrucción de la luz arterial. La pared de la arteria se engrosa debido al depósito de elementos grasos tales como el colesterol. Los stents intraluminales son diminutas estructuras tubulares autoexpandibles de malla de metal, que se colocan dentro de la arteria coronaria después de una angioplastia con balón para prevenir el cierre de dicha arteria. A pesar de estar diseñados para ser compatibles con el tejido humano, a menudo se da una reacción en cadena de consecuencias indeseables. La reestenosis intra-stent es un problema creciente debido al importante incremento que se ha producido en la utilización del stent intracoronario como forma de revascularización percutánea. Se habla de una incidencia global del 28%, siendo la causa principal de su aparición la proliferación neointimal a través de una compleja cascada de sucesos que pueden tardar meses en desarrollarse. Una de las reacciones más importantes es la trombosis o la formación de una fina capa de coágulo como respuesta a la presencia de un material extraño. Este proceso es multifactorial, y en él intervienen la regresión de la pared como consecuencia del estiramiento previo, la denudación endotelial, lo que permite la agregación plaquetaria, la proliferación neointimal, lo que facilita a los receptores de membrana desencadenar un proceso de agregación posterior y, por último, el remodelado negativo inadecuado de la pared, lo que produce pérdida de luz arterial. Se ha observado frecuentemente que el depósito de ateroma en la pared arterial está relacionado con el valor de los esfuerzos cortantes en la misma. Hay mayores probabilidades de engrosamiento de la pared en las zonas donde son bajos los esfuerzos cortantes, quizá por el mayor tiempo de residencia de las partículas circulantes por el torrente sanguíneo. Si nos centramos en la afirmación anterior, el siguiente paso sería buscar las zonas susceptibles de presentar un valor bajo de dichos esfuerzos. Las zonas potencialmente peligrosas son los codos y bifurcaciones, entre otras. Nos hemos centrado en una bifurcación coronaria, ya que los patrones de flujo que se suelen presentar, tales como recirculación y desprendimiento de vórtices están íntimamente relacionados con las técnicas de implantación de stents en esta zona. Proyectamos nuestros esfuerzos en el estudio de dos técnicas de implante, utilizando un único stent y una tercera a través de una configuración de culotte con el uso de dos stents. El primer caso trata de una bifurcación con un único stent en la rama principal cuyos struts cierran el orificio lateral que da salida a la rama secundaria de la bifurcación, es decir sería un stent sin orificio. El segundo consiste en un único stent también, pero con la diferencia de que éste presenta un orificio de comunicación con la rama lateral. Todas estas técnicas se aplicaron a bifurcaciones de 45º y de 90º. Introdujimos las geometrías -una vez confeccionadas con el código comercial Gambit- en el programa Ansys-Fluent contemplando régimen estacionario. Los resultados obtenidos fueron cotejados con los experimentales, que se realizaron paralelamente, con el fin de corroborarlos. Una vez validados, el estudio computacional ya contó con la fiabilidad suficiente como para abordar el régimen no estacionario, tanto en la versión de reposo como en la de ejercicio –hiperemia- El comportamiento reológico de la sangre para régimen no estacionario en estado de reposo es otra de las tareas abordadas, realizando una comparativa de los modelos Newtoniano, Carreau y Ley de Potencias. Finalmente, en una última etapa, debido a la reciente incursión de los stents diseñados específicamente frente a los convencionales, se aborda el comportamiento hemodinámico de los mismos. Concretamente, se comparó el patrón de flujo en un modelo de bifurcación coronaria con los nuevos stents (Stentys) y los convencionales. Se estudiaron cuatro modelos, a saber, stent simple en la rama principal, stent simple en la rama secundaria, culotte desplegando el primer stent en la rama principal y culotte desplegando el primer stent en la rama secundaria. La bifurcación estudiada presenta un ángulo de apertura de 45º y la relación de diámetros de las ramas hija se ajustaron de acuerdo a la ley de Finet. Se recogieron resultados experimentales en el laboratorio y se corrieron simulaciones numéricas con Ansys Fluent paralelamente. Las magnitudes que se tuvieron en cuenta con el fin de ubicar las regiones potencialmente ateroscleróticas fueron los esfuerzos cortantes, vorticidad y caída de presión. ABSTRACT Nowadays, restenosis after percutaneous dilation is the major drawback of coronary angioplasty. It represents a special form of atherosclerosis due to the healing process secondary to extensive vessel trauma induced after intracoronary balloon inflation. The use of coronary stents may decrease the incidence of this phenomenon. Unfortunately, intra-stent restenosis still occurs in 20-30% of the cases following the stent implantation. Most experiments suggest a correlation between low wall shear stress and wall thickness. The preferential locations for the atherosclerotic plaque are bifurcations. The objective of this work is to analyze the local hemodynamic changes caused in a coronary bifurcation by three different stenting techniques: simple stenting of the main vessel, simple stenting of the main vessel with kissing balloon in the side branch and culotte. To carry out this study an idealized geometry of a coronary bifurcation is used, and two bifurcation angles, 45º and 90º, are chosen as representative of the wide variety of real configurations. Both numerical simulations and experimental measurements are performed. First, steady simulations are carried out with the commercial code Ansys-Fluent, then, experimental measurements with PIV (Particle Image Velocimetry), obtained in the laboratory, are used to validate the numerical simulations. The steady computational simulations show a good overall agreement with the experimental data. Then, pulsatile flow is considered to take into account the transient effects. The time averaged wall shear stress, oscillatory shear index and pressure drop obtained numerically are used to compare the behavior of the stenting techniques. In a second step, the rheologic behavior of blood was considered comparing Newtonian, Carreau and Power Law models. Finally, as a result of previous investigations with conventional stents and after the recent emergence of several devices specifically designed for coronary bifurcations angioplasty, the hemodynamic performance of these new devices (Stentys) was compared to conventional ones and techniques in a coronary bifurcation model. Four different stenting techniques: simple stenting of the main vessel, simple stenting of the side vessel, culotte deploying the first stent in the main vessel and culotte deploying the first stent in the side vessel have been considered. To carry out this study an idealized geometry of a coronary bifurcation is used. A 45 degrees bifurcation angle is considered and the daughter branches diameters are obtained according to the Finet law. Both experiments in the laboratory and numerical simulations were used , focusing on important factors for the atherosclerosis development, like the wall shear stress, the oscillation shear index, the pressure loss and the vorticity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Large-eddy simulation is used to predict heat transfer in the separated and reattached flow regions downstream of a backward-facing step. Simulations were carried out at a Reynolds number of 28 000 (based on the step height and the upstream centreline velocity) with a channel expansion ratio of 1.25. The Prandtl number was 0.71. Two subgrid-scale models were tested, namely the dynamic eddy-viscosity, eddy-diffusivity model and the dynamic mixed model. Both models showed good overall agreement with available experimental data. The simulations indicated that the peak in heat-transfer coefficient occurs slightly upstream of the mean reattachment location, in agreement with experimental data. The results of these simulations have been analysed to discover the mechanisms that cause this phenomenon. The peak in heat-transfer coefficient shows a direct correlation with the peak in wall shear-stress fluctuations. It is conjectured that the peak in these fluctuations is caused by an impingement mechanism, in which large eddies, originating in the shear layer, impact the wall just upstream of the mean reattachment location. These eddies cause a 'downwash', which increases the local heat-transfer coefficient by bringing cold fluid from above the shear layer towards the wall.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The pumping characteristics of four Australian honey samples were investigated in a straight pipe. Six flow rates (100-500 kg h(-1)) were studied at three temperatures (35-50degreesC). The pressure loss increased with an increase in the length of the pipe, as the low rate was increased and as the temperature was reduced. In the 25.4 mm-pipe, the Reynolds number ranged from 0.2-32.0 and are substantially less than the critica value (2040-2180) for laminar condition in the system. The relationship between the wall shear stress and shear rate approximated power-law behaviour, and the power-law index was not significantly (p>0.05) different from 1.0. The honey samples exhibited Newtonian behaviour at all the temperatures and this was confirmed by rheometric studies using Couette geometry. A friction chart was generated independent of temperature and the type of honey. An equation was developed to predict the pressure loss of the honey in a typical pipeline at any temperature once the viscosity-temperature relationship had been established.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A recently developed whole of surface electroplating technique was used to obtain mass-transfer rates in the separated flow region of a stepped rotating cylinder electrode. These data are compared with previously reported mass-transfer rates obtained with a patch electrode. It was found that the two methods yield different results, where at lower Reynolds numbers, the mass-transfer rate enhancement was noticeably higher for the whole of the surface electrode than for the patch electrode. The location of the peak mass transfer behind the step, as measured with a patch electrode, was reported to be independent of the Reynolds number in previous studies, whereas the whole of the surface electrode shows a definite Reynolds number dependence. Large eddy simulation results for the recirculating region behind a step are used in this work to show that this difference in behavior is related to the existence of a much thinner fluid layer at the wall for which the velocity is a linear junction of distance from the wall. Consequently, the diffusion layer no longer lies well within a laminar sublayer. It is concluded that the patch electrode responds to the wall shear stress for smooth wall flow as well as for the disturbed flow region behind the step. When the whole of the surface is electro-active, the response is to mass transfer even when this is not a sole function of wall shear stress. The results demonstrate that the choice of the mass-transfer measurement technique in corrosion studies can have a significant effect on the results obtained from empirical data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we examine the effect of contact angle (or surface wettability) on the convective heat transfer coefficient in microchannels. Slip flow, where the fluid velocity at the wall is non-zero, is most likely to occur in microchannels due to its dependence on shear rate or wall shear stress. We show analytically that for a constant pressure drop, the presence of slip increases the Nusselt number. In a microchannel heat exchanger we modified the surface wettability from a contact angle of 20 degrees-120 degrees using thin film coating technology. Apparent slip flow is implied from pressure and flow rate measurements with a departure from classical laminar friction coefficients above a critical shear rate of approximately 10,000 s(-1). The magnitude of this departure is dependant on the contact angle with higher contact angles surfaces exhibiting larger pressure drop decreases. Similarly, the non-dimensional heat flux is found to decrease relative to laminar non-slip theory, and this decrease is also a function of the contact angle. Depending on the contact angle and the wall shear rate, variations in the heat transfer rate exceeding 10% can be expected. Thus the contact angle is an important consideration in the design of micro, and even more so, nano heat exchangers. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Turbulent flow around a rotating circular cylinder has numerous applications including wall shear stress and mass-transfer measurement related to the corrosion studies. It is also of interest in the context of flow over convex surfaces where standard turbulence models perform poorly. The main purpose of this paper is to elucidate the basic turbulence mechanism around a rotating cylinder at low Reynolds numbers to provide a better understanding of flow fundamentals. Direct numerical simulation (DNS) has been performed in a reference frame rotating at constant angular velocity with the cylinder. The governing equations are discretized by using a finite-volume method. As for fully developed channel, pipe, and boundary layer flows, a laminar sublayer, buffer layer, and logarithmic outer region were observed. The level of mean velocity is lower in the buffer and outer regions but the logarithmic region still has a slope equal to the inverse of the von Karman constant. Instantaneous flow visualization revealed that the turbulence length scale typically decreases as the Reynolds number increases. Wavelet analysis provided some insight into the dependence of structural characteristics on wave number. The budget of the turbulent kinetic energy was computed and found to be similar to that in plane channel flow as well as in pipe and zero pressure gradient boundary layer flows. Coriolis effects show as an equivalent production for the azimuthal and radial velocity fluctuations leading to their ratio being lowered relative to similar nonrotating boundary layer flows.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Design and analysis of conceptually different cooling systems for the human heart preservation are numerically investigated. A heart cooling container with required connections was designed for a normal size human heart. A three-dimensional, high resolution human heart geometric model obtained from CT-angio data was used for simulations. Nine different cooling designs are introduced in this research. The first cooling design (Case 1) used a cooling gelatin only outside of the heart. In the second cooling design (Case 2), the internal parts of the heart were cooled via pumping a cooling liquid inside both the heart’s pulmonary and systemic circulation systems. An unsteady conjugate heat transfer analysis is performed to simulate the temperature field variations within the heart during the cooling process. Case 3 simulated the currently used cooling method in which the coolant is stagnant. Case 4 was a combination of Case 1 and Case 2. A linear thermoelasticity analysis was performed to assess the stresses applied on the heart during the cooling process. In Cases 5 through 9, the coolant solution was used for both internal and external cooling. For external circulation in Case 5 and Case 6, two inlets and two outlets were designed on the walls of the cooling container. Case 5 used laminar flows for coolant circulations inside and outside of the heart. Effects of turbulent flow on cooling of the heart were studied in Case 6. In Case 7, an additional inlet was designed on the cooling container wall to create a jet impinging the hot region of the heart’s wall. Unsteady periodic inlet velocities were applied in Case 8 and Case 9. The average temperature of the heart in Case 5 was +5.0oC after 1500 s of cooling. Multi-objective constrained optimization was performed for Case 5. Inlet velocities for two internal and one external coolant circulations were the three design variables for optimization. Minimizing the average temperature of the heart, wall shear stress and total volumetric flow rates were the three objectives. The only constraint was to keep von Mises stress below the ultimate tensile stress of the heart’s tissue.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of supersonic engine inlets and external aerodynamic surfaces can be critically affected by shock wave / boundary layer interactions (SBLIs), whose severe adverse pressure gradients can cause boundary layer separation. Currently such problems are avoided primarily through the use of boundary layer bleed/suction which can be a source of significant performance degradation. This study investigates a novel type of flow control device called micro-vortex generators (µVGs) which may offer similar control benefits without the bleed penalties. µVGs have the ability to alter the near-wall structure of compressible turbulent boundary layers to provide increased mixing of high speed fluid which improves the boundary layer health when subjected to flow disturbance. Due to their small size,µVGs are embedded in the boundary layer which provide reduced drag compared to the traditional vortex generators while they are cost-effective, physically robust and do not require a power source. To examine the potential of µVGs, a detailed experimental and computational study of micro-ramps in a supersonic boundary layer at Mach 3 subjected to an oblique shock was undertaken. The experiments employed a flat plate boundary layer with an impinging oblique shock with downstream total pressure measurements. The moderate Reynolds number of 3,800 based on displacement thickness allowed the computations to use Large Eddy Simulations without the subgrid stress model (LES-nSGS). The LES predictions indicated that the shock changes the structure of the turbulent eddies and the primary vortices generated from the micro-ramp. Furthermore, they generally reproduced the experimentally obtained mean velocity profiles, unlike similarly-resolved RANS computations. The experiments and the LES results indicate that the micro-ramps, whose height is h≈0.5δ, can significantly reduce boundary layer thickness and improve downstream boundary layer health as measured by the incompressible shape factor, H. Regions directly behind the ramp centerline tended to have increased boundary layer thickness indicating the significant three-dimensionality of the flow field. Compared to baseline sizes, smaller micro-ramps yielded improved total pressure recovery. Moving the smaller ramps closer to the shock interaction also reduced the displacement thickness and the separated area. This effect is attributed to decreased wave drag and the closer proximity of the vortex pairs to the wall. In the second part of the study, various types of µVGs are investigated including micro-ramps and micro-vanes. The results showed that vortices generated from µVGs can partially eliminate shock induced flow separation and can continue to entrain high momentum flux for boundary layer recovery downstream. The micro-ramps resulted in thinner downstream displacement thickness in comparison to the micro-vanes. However, the strength of the streamwise vorticity for the micro-ramps decayed faster due to dissipation especially after the shock interaction. In addition, the close spanwise distance between each vortex for the ramp geometry causes the vortex cores to move upwards from the wall due to induced upwash effects. Micro-vanes, on the other hand, yielded an increased spanwise spacing of the streamwise vortices at the point of formation. This resulted in streamwise vortices staying closer to the wall with less circulation decay, and the reduction in overall flow separation is attributed to these effects. Two hybrid concepts, named “thick-vane” and “split-ramp”, were also studied where the former is a vane with side supports and the latter has a uniform spacing along the centerline of the baseline ramp. These geometries behaved similar to the micro-vanes in terms of the streamwise vorticity and the ability to reduce flow separation, but are more physically robust than the thin vanes. Next, Mach number effect on flow past the micro-ramps (h~0.5δ) are examined in a supersonic boundary layer at M=1.4, 2.2 and 3.0, but with no shock waves present. The LES results indicate that micro-ramps have a greater impact at lower Mach number near the device but its influence decays faster than that for the higher Mach number cases. This may be due to the additional dissipation caused by the primary vortices with smaller effective diameter at the lower Mach number such that their coherency is easily lost causing the streamwise vorticity and the turbulent kinetic energy to decay quickly. The normal distance between the vortex core and the wall had similar growth indicating weak correlation with the Mach number; however, the spanwise distance between the two counter-rotating cores further increases with lower Mach number. Finally, various µVGs which include micro-ramp, split-ramp and a new hybrid concept “ramped-vane” are investigated under normal shock conditions at Mach number of 1.3. In particular, the ramped-vane was studied extensively by varying its size, interior spacing of the device and streamwise position respect to the shock. The ramped-vane provided increased vorticity compared to the micro-ramp and the split-ramp. This significantly reduced the separation length downstream of the device centerline where a larger ramped-vane with increased trailing edge gap yielded a fully attached flow at the centerline of separation region. The results from coarse-resolution LES studies show that the larger ramped-vane provided the most reductions in the turbulent kinetic energy and pressure fluctuation compared to other devices downstream of the shock. Additional benefits include negligible drag while the reductions in displacement thickness and shape factor were seen compared to other devices. Increased wall shear stress and pressure recovery were found with the larger ramped-vane in the baseline resolution LES studies which also gave decreased amplitudes of the pressure fluctuations downstream of the shock.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our goal in this paper is to extend previous results obtained for Newtonian and secondgrade fluids to third-grade fluids in the case of an axisymmetric, straight, rigid and impermeable tube with constant cross-section using a one-dimensional hierarchical model based on the Cosserat theory related to fluid dynamics. In this way we can reduce the full threedimensional system of equations for the axisymmetric unsteady motion of a non-Newtonian incompressible third-grade fluid to a system of equations depending on time and on a single spatial variable. Some numerical simulations for the volume flow rate and the the wall shear stress are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The activity of growing living bacteria was investigated using real-time and in situ rheology-in stationary and oscillatory shear. Two different strains of the human pathogen Staphylococcus aureus-strain COL and its isogenic cell wall autolysis mutant, RUSAL9-were considered in this work. For low bacteria density, strain COL forms small clusters, while the mutant, presenting deficient cell separation, forms irregular larger aggregates. In the early stages of growth, when subjected to a stationary shear, the viscosity of the cultures of both strains increases with the population of cells. As the bacteria reach the exponential phase of growth, the viscosity of the cultures of the two strains follows different and rich behaviors, with no counterpart in the optical density or in the population's colony-forming units measurements. While the viscosity of strain COL culture keeps increasing during the exponential phase and returns close to its initial value for the late phase of growth, where the population stabilizes, the viscosity of the mutant strain culture decreases steeply, still in the exponential phase, remains constant for some time, and increases again, reaching a constant plateau at a maximum value for the late phase of growth. These complex viscoelastic behaviors, which were observed to be shear-stress-dependent, are a consequence of two coupled effects: the cell density continuous increase and its changing interacting properties. The viscous and elastic moduli of strain COL culture, obtained with oscillatory shear, exhibit power-law behaviors whose exponents are dependent on the bacteria growth stage. The viscous and elastic moduli of the mutant culture have complex behaviors, emerging from the different relaxation times that are associated with the large molecules of the medium and the self-organized structures of bacteria. Nevertheless, these behaviors reflect the bacteria growth stage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Saphenous vein graft bypass remains the salvage option when¦endovascular procedure has failed or was contraindicated due to extensive¦occlusive lesions. However, pathological wall remodeling leading leading to¦graft failure is one of the most limiting factors of this therapy. Therefore, the¦understanding of this remodeling process of human vein is essential to the design¦of future effective therapeutics and it requires an adapted model of ex-vivo vein¦perfusion.¦Methods: We have developed an ex vivo vein support system (EVVSS), which¦uses standardized and controlled hemodynamic parameters for the pulsatile¦perfusion of saphenous vein segments. The morphological and molecular¦parameters involved in the remodeling process under an arterial shear stress¦associated to low (7 mm Hg) or high (70 mm Hg) pressure conditions can be¦analyzed.¦Results: Histomorphometric analysis showed that the vein segments perfused¦during 7 days under high pressure undergo a significant neointima development¦compared to veins exposed to low pressure conditions. The application of an¦arterial shear stress in the vein under low pressure induced an elevation of the¦MMP-2 and MMP-9 expression, activity and transcription. The application of¦higher pressure is associated to increased MMP2 expression and transcription¦and MMP9 transcription. TIMP1 expression and transcription were initiated by¦the application of an arterial shear stress but not modified by the modification¦of the pressure. However, TIMP2 expression was increased under high¦pressure conditions but its transcription was inhibited by arterial shear stress,¦independently of the pressure. The values of transcription and expression of¦PAI-1 were not modified by high pressure. Eph-B4 transcription and expression¦were significantly decreased under arterial shear stress.¦Conclusion: These data show that our EVVSS is a valuable setting to study¦ex vivo remodeling of human saphenous veins submitted to arterial conditions.¦The intimal hyperplasia as well as MMP 2, 9 and TIMP 2 seem to be influenced¦by the pressure.