935 resultados para Ultra-som transcuneal


Relevância:

80.00% 80.00%

Publicador:

Resumo:

High carotid artery resistance indices in the elderly arise mainly as a result of harmful daily lifestyle behavior and poor eating habits. The aim of this multidisciplinary study was to assess and correlate carotid artery resistance and functional autonomy in elderly women. A descriptive, exploratory cross-sectional study was conducted with a sample comprising 27 women, enrolled in pastoral programs in the city of Teresina, Brazil. Carotid artery resistance was assessed by a high-resolution Doppler ultrasound device and functional autonomy was evaluated through five protocol tests of the Latin American Development Group for the Elderly (GDLAM), simulating activities of daily life. The data were analyzed by the Shapiro-Wilk test and the correlation by Spearman s test, considering a p-value of <0.05. The sample consisted of women with mean age and standard deviation of (68.67 ± 4.52) years, respectively and carotid resistance index of (0.71 ± 0.07). The general index value of functional autonomy classified the elderly of the study group as weak in the performance of activities of daily living (30.46 ± 6.31). The general index of functional autonomy showed a high level of sedentary behavior in the group studied (p < 0.01). The sample was classified as weak in the performance of activities of daily life. The correlation coefficient between the carotid resistance index and the general GDLAM index was r = 0.998 and p = 0.000, showing a significant correlation. The elderly women assessed had a high carotid artery resistance index and low functional autonomy; a positive correlation was found between the dependent variables studied. To perform this study we formed a team composed of a nurse, who helped in organizing the sample and performing the examinations; a radiologist, who conducted the Doppler examinations; an angiologist, who collaborated in interpreting examination data; in addition to two physical education professors and two physical therapists, who applied the functional autonomy tests and conducted the 34 research along elderly health lines, contributing thus to the multidisciplinary character, fundamental for carrying out the study

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A prática regular de exercício físico possibilita redução dos efeitos das disfunções hormonais e envelhecimento biológico natural que promovem desajustes hemodinâmicos, vasculares e músculo-esqueléticos, principalmente na população feminina no período pós-menopausa. Nesta fase da vida, o exercício aquático representa mais do que uma forma de ajuste funcional, é uma forma de manutenção de independência para as atividades da vida diária (AVD s) e melhoria na qualidade de vida. Este estudo teve como objetivo avaliar as modificações adquiridas pela prática regular de um programa de exercício aquático concorrente de intensidade moderada no nível de óxido nítrico (ON), no índice de resistividade arterial (IR), no perfil lipídico, na capacidade funcional e na qualidade de vida de idosas. A amostra foi formada por idosas (60 a 80 anos) selecionadas por randomização, por sorteio simples divididas em grupo controle e grupo de intervenção as quais foram submetidas a um programa de exercícios aquáticos proposto inicialmente em projeto piloto, por 12 semanas (n=34) e o ensaio clínico teve duração de 16 semanas (n=40). Foi coletada amostra sanguínea das idosas e avaliado o perfil lipídico pelo método enzimático com kit Labtest e o ON por medida indireta a partir da concentração de nitrito no sobrenadante das células em cultura em leitor de ELISA. A avaliação das artérias carótidas e vertebrais foi feita utilizando o método de ultra-som Doopler. A capacidade funcional foi avaliada por quatro testes que simulam atividades da vida diária que são: caminhar 10 metros (C10m), levantar da posição sentada (LPS), levantar da cadeira e locomover-se pela casa (LCLC) e o de levantar-se da posição decúbito ventral (LPDV). No estudo piloto foi avaliado o índice geral de autonomia funcional (IG) e a qualidade de vida através do questionário WHOQOL-100. Empregou-se a análise de variância (ANOVA) com medidas repetidas nos fatores grupo (GH e GC) e tempo (pré e pós-teste) para as comparações intra e intergrupos nas variáveis seguida do post hoc de Scheffé. Utilizou-se o teste de correlação de Pearson e adotado o valor de p<0,05 para a significância estatística. Houve aumento do ON circulante, redução nos índices de resistividade arterial, melhoria significativa nos níveis de colesterol e triglicérides e ganho na capacidade funcional das idosas após a intervenção. Existiu correlação inversa entre a resistividade da artéria vertebral direita (VERTD) e níveis de ON e entre a VERTD e os níveis plasmáticos de HDL, assim como entre estes e o teste C10m nas idosas em estudo. Não houve modificações significativas na qualidade de vida das idosas. Em conclusão, o programa de exercício proposto foi capaz de oferecer melhorias funcionais, aumentar o nível de óxido nítrico circulante, diminuindo a resistência arterial promovendo modificações no perfil lipídico de idosas

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Uma cadela da raça Yorkshire Terrier apresentou hematêmese, distensão abdominal, poliúria e polidipsia. Após o exame clínico do paciente, estabeleceu-se a suspeita clínica de nefropatia. Os resultados dos exames laboratoriais revelaram anemia normocítica normocrômica e concentrações séricas de uréia (306mg/dl) e de creatinina (3,6mg/dl) acima dos valores de referência. Ao ultra-som bidimensional observaram-se áreas císticas hipoecóicas e anecóicas, padrão renal hipercogênico e perda da relação corticomedular. À necropsia, a região medular apresentou grande quantidade de cistos pequenos em meio a tecido conjuntivo fibroso. A lesão tubulointersticial cortical foi a responsável pela insuficiência renal resultante. Firmou-se diagnóstico de nefrite tubulointersticial.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O objetivo nesta pesquisa foi avaliar o efeito de dois ingredientes protéicos da dieta (farelo de soja e de algodão) e de dois processamentos físicos do concentrado (farelado e extrusado) na terminação de 16 bovinos machos não-castrados da raça Canchim. Avaliaram-se ainda a excreção de nutrientes nos dejetos e o potencial de produção de biogás. Os animais tinham 12 meses de idade e 315 kg PC, em média, e foram confinados em baias individuais durante 147 dias (os primeiros 35 dias foram de adaptação). Como volumoso utilizou-se silagem de milho, em uma relação volumoso:concentrado de 50:50, com base na MS. Os resultados foram analisados em delineamento inteiramente casualizado, em esquema fatorial 2 × 2 (fonte protéica × processamento físico). A fonte protéica influenciou o ganho de peso corporal (1,50 e 1,35 kg/dia para o farelo de soja e de algodão, respectivamente), a conversão alimentar (4,73 e 5,31 kg MS ingerida/kg de ganho de peso, respectivamente) e a eficiência protéica (1,78 e 1,59 kg de ganho de peso/kg PB ingerida, respectivamente). O tratamento físico do concentrado e a fonte protéica não influenciaram a ingestão de MS, a área de olho-de-lombo e a espessura de gordura, estimadas por ultra-som. O balanço de nutrientes foi semelhante entre tratamentos para MS, FDN e FDA, mas a fonte protéica determinou diferenças no balanço de PB. Entre os macro e microminerais quantificados nas fezes, os teores de P e Mg diferiram entre as fontes protéicas e a extrusão aumentou o conteúdo de Ca, com médias de 0,39 e 0,43 g/100 g de MS de dejetos, respectivamente, para os concentrados farelado e extrusado. Os dejetos produziram biogás de maneira efetiva entre o 70º e o 200º dia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Numerosas pesquisas têm estudado os métodos não-destrutivos de avaliação de materiais e sua aplicação àqueles de matrizes complexas, como é o caso da madeira. Um dos primeiros métodos não-destrutivos investigados para aplicação nesses casos foi o da vibração transversal. Apesar de sua concepção simples, e a despeito dos grandes avanços obtidos nessa área com outros métodos, como, por exemplo, o ultra-som, o método de vibração transversal para a determinação do módulo de elasticidade da madeira revela-se como de grande potencial de aplicação, sobretudo pela precisão do modelo matemático a ele associado e pela possibilidade de sua aplicação a peças de dimensões estruturais (in-grade testing). Neste trabalho, apresenta-se o uso desse método na determinação do módulo de elasticidade de três espécies de eucalipto. Foram ensaiados não-destrutivamente e por ensaios mecânicos convencionais de flexão corpos-de-prova de 2 cm x 2 cm x 46 cm de E. grandis, E. saligna e E. citriodora. Os ensaios não-destrutivos foram conduzidos com uso do sistema BING - Beam Identification by Non-destructive Grading, que permite a análise das vibrações do material nos domínios do tempo e da freqüência. Os resultados obtidos revelaram boa correlação entre os dois tipos de ensaios empregados, justificando o início dos ensaios com peças de dimensões estruturais, para a viabilização da técnica nas práticas de classificação estrutural.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The modern technology of materials and structural integrity of pipelines requests the use of inspection tools named inspection pigs to detect, localize and measure the length, width and depth dimensions of the thickness losses of walls of buried and underwater pipelines in service. These tools run them internally, performing and recording measurements, with performance that varies according to the pig s technology. It has been developed recently an instrumented pig technology, called feller pig. This work aims to indicate factors that influence the feller pig technology performance in the detection and in the accuracy of measurement of the length, width and depth dimensions of the thickness losses on the internal surface of an oil pipeline wall under normal conditions of oil pipe inspection with pig. In this work, is made a collection of factors and an analyses of the technology based on the available literature, as well as an experiment to observe the technology and the factors operating. In the experiment, a feeler pig is used in a pipeline built in carbon steel and in operation that flows petroleum, in witch are observed areas with internal thickness losses occurred naturally. Some of these areas and their dimensions taken by automated ultra-sound scanner are compared with the ones indicated by the feller pig. Based on the data collection, on the analysis and on the experiment, the influence of factors object of this research is discussed. It is concluded that, among these, there are factors related to pipe fabrication tolerances, to wear of pig components, to internal adhesive wear of pipeline, to other pipeline damages and to technology characteristics. Finally, actions are suggested to know better, improve and define the applicability of this technology

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In general, the designs of equipment takes into account the effects and processes of deterioration it will undergo and arrives at an approximate useful life. However, changes in operational processes and parameters, the action of external agents, the kind of maintenance conducted, the means of monitoring, and natural and accidental occurrences completely modify the desired performance of the equipment. The discontinuities that occur in anisotropic materials often and due to different factors evolve from being subcritical to critical acquiring the status of defect and compromising the physical integrity of the equipment. Increasingly sophisticated technological means of detection, monitoring and assessment of these discontinuities are required to respond ever more rapidly to the requirements of industry. This paper therefore presents a VPS (Virtual Pipe System) computational tool which uses the results of ultrasonic tests on equipment, plotting the discontinuities found in models created in the CAD and CAE systems, and then simulates the behavior of these defects in the structure to give an instantaneous view of the final behavior. This paper also presents an alternative method of conventional ultrasonic testing which correlates the integrity of an overlay (carbon steel and stainless steel attached by welding) and the reflection of ultrasonic waves coming from the interface between the two metals, thus making it possible to identify cracks in the casing and a shift of the overlay

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PAHs (Polycyclic Aromatic Hydrocarbons) are a group of organic substances which receive considerable attention because of the carcinogenic and mutagenic properties of some of them. It is therefore important to determine the PAHs in different environmental matrices. Several studies have shown the use of gas chromatography coupled to mass spectrometry as a technique for quantification of PAHs by presenting excellent detection limits. This study aimed to develop an analytical methodology for the determination of 16 PAHs listed by the USEPA, test two methods for extraction of PAHs in water from a 23 factorial design, quantify them through the analytical technique coupled to gas chromatography mass spectrometry (GC/MS) using the method developed, and finally apply the results in chemometrics. The sample was synthesized and subjected to tests of the 23 factorial design, which has the factors: the type of extraction technique (ultrasound and digester), the ratio solvent / sample (1:1 and 1:3) and the type of solvent (dichloromethane / hexane and acetone / dichloromethane). The responses of eight combinations of the factorial design were obtained from the quantification by external calibration in GC/MS. The quantification method was developed from an optimized adaptation of the USEPA Method 8270. We used the full scan mode as a way of acquiring the mass spectra of 16 PAHs. The time in which the samples were subjected to ultrasound was fixed at 10 min and held an investigation to establish the conditions of power and time in the digester. We had the best response in the investigation of the digester power of 100 watts and the time of six minutes. The factorial design of liquid-liquid extraction showed that the most representative factors were: the use of the digester as extraction technique, the ratio solvent / sample 1:1 and the use of a 1:1 mixture of dichloromethane / hexane as a solvent more suitable. These results showed that the 1:1 mixture of dichloromethane / hexane is an excellent mixture to recover the extraction of PAHs an aqueous sample using the microwave digester. The optimization of the method of separation, identification and quantification of PAHs in the GC/MS was valid for 16 PAHs present in each chromatogram of the samples

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este estudo apresenta resultados preliminares obtidos com um novo filtro permanente de veia cava, baseado no desenho de Greenfield, com três hastes prolongadas de um total de seis, para dar estabilidade central ao filtro na luz da veia cava. Neste artigo, relatamos sua avaliação clínica preliminar quanto à aplicabilidade, eficácia e segurança. de agosto de 2004 a dezembro de 2006, 15 filtros foram implantados em nove homens e seis mulheres, com idades variando de 38 a 79 anos (média de 57,8 anos). O acesso foi feito sempre por via transjugular. As indicações foram: trombose venosa proximal, com contra-indicação de anticoagulação em 12 pacientes; complicações hemorrágicas com anticoagulação em dois pacientes; e embolia pulmonar, apesar de anticoagulação adequada, em um paciente. Os filtros foram avaliados quanto à liberação, inclinação, mau posicionamento e perfuração de cava. No seguimento, avaliou-se trombose no local de acesso, tromboembolismo venoso recorrente, migração do filtro e trombose de cava pelo ultra-som. Nenhum paciente recebeu anticoagulantes no seguimento. O filtro foi liberado com sucesso em todos os casos sem mau posicionamento, inclinação, perfuração ou trombose de acesso. Os pacientes foram seguidos entre 3 e 23 meses (média de 11 meses). Nenhum paciente teve recorrência de tromboembolismo venoso. Não houve casos de trombose de veia cava ou migração do filtro. Óbito ocorreu em sete casos, todos relacionados com a moléstia de base. Os resultados preliminares indicam potencial eficácia e segurança do uso do novo filtro no período estudado.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O diagnóstico da trombose venosa profunda sintomática está bem estabelecido com o uso do mapeamento dúplex, que apresenta sensibilidade de 100% e especificidade de 98%, para trombose venosa profunda proximal, e sensibilidade de 94% e especificidade de 75%, para distal. Na trombose venosa profunda recente e assintomática, o diagnóstico com o mapeamento dúplex ainda não está bem estabelecido, mostrando uma queda na acurácia desse método diagnóstico. Essa queda é devida ao fato de o trombo recente não ser oclusivo, apresentar a mesma ecogenicidade do sangue e uma consistência diminuída, prejudicando o teste da compressibilidade, que é o mais sensível para diagnóstico da trombose venosa profunda. Nesta revisão, serão revistos artigos publicados que avaliaram a acurácia do mapeamento dúplex no diagnóstico da trombose venosa profunda assintomática.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A avaliação clínica dos membros inferiores na insuficiência venosa por si só não identifica os sistemas envolvidos ou os níveis anatômicos, sendo necessários exames complementares. Esses exames podem ser invasivos ou não-invasivos. Os invasivos, como flebografia e pressão venosa ambulatória, apesar de terem boa acurácia, trazem desconforto e complicações. Dentre os não-invasivos, destacam-se: Doppler ultra-som de ondas contínuas, fotopletismografia, pletismografia a ar e mapeamento dúplex. O Doppler ultra-som avalia a velocidade do fluxo sangüíneo de maneira indireta. A fotopletismografia avalia o tempo de reenchimento venoso, fornecendo um parâmetro objetivo de quantificação do refluxo venoso. A pletismografia a ar permite quantificar a redução ou não da capacitância, o refluxo e o desempenho da bomba muscular da panturrilha. O dúplex é considerado padrão-ouro dentre os não-invasivos, porque permite uma avaliação quantitativa e qualitativa, fornecendo informações anatômicas e funcionais, dando avaliação mais completa e detalhada dos sistemas venosos profundo e superficial.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

CONTEXTO: A aplicação de uma estratégia baseada em um modelo clínico associado ao mapeamento dúplex (MD) pode permitir um diagnóstico da trombose venosa profunda (TVP) mais seguro, eficaz e custo-efetivo. OBJETIVO: Testar o modelo clínico de Wells et al. associado ao MD e verificar a ocorrência de TVP nos pacientes categorizados quanto à probabilidade de apresentar a doença, e determinar se, a partir dos resultados obtidos, seria possível reduzir o número de exames seriados com o MD. MÉTODOS: Os pacientes com suspeita clínica de TVP foram categorizados quanto à apresentação de TVP em baixa, moderada e alta probabilidade (BP, MP, AP) e, em seguida, submetidos ao MD. Pacientes com MD negativo repetiram o exame em 24-48 horas e em 7 dias. Pacientes com exame positivo para TVP foram tratados. Todos os pacientes sem TVP foram convocados para reavaliação clínica em 3 meses. RESULTADOS: A ocorrência de TVP entre os 489 pacientes avaliados foi de 39,1% (191), sendo 35,6% identificados no exame inicial e 3,5% no exame seriado. Os índices de pacientes que apresentaram TVP foram de 6,1% no grupo de BP, 26,9% no grupo de MP e 79,5% no grupo de AP. No exame seriado, o percentual de TVP foi de 2,4, 7,8 e 15,1% nos grupos BP, MP e AP, respectivamente. Dos pacientes com MD negativo, 62,4% compareceram após 3 meses, e piora dos sintomas foi apresentada por apenas um paciente. Neste, o MD mostrou TVP de veia poplítea. CONCLUSÃO: Os resultados obtidos sugerem que, para os pacientes com BP para TVP e MD negativo, seria possível prescindir do exame seriado, devido à baixa ocorrência de TVP neste grupo, tornando, assim, a abordagem diagnóstica mais simples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

CONTEXTO E OBJETIVO: A biópsia da próstata não é um procedimento isento de riscos. Existe preocupação com respeito às complicações e quais seriam os melhores antibióticos usados antes do procedimento. O objetivo foi determinar a taxa de complicações e os possíveis fatores de risco para complicação na biópsia da próstata. TIPO DE ESTUDO E LOCAL: Estudo prospectivo clínico, realizado no Hospital das Clínicas de Botucatu. MÉTODOS: Foram realizadas biópsias em 174 pacientes que apresentavam anormalidade ao exame digital da próstata ou antígeno prostático específico maior que 4 ng/ml ou ambos. Todos os pacientes realizaram enema e antibioticoprofilaxia previamente ao exame. As complicações foram anotadas após o término do procedimento e em consultas posteriores. Algumas condições foram investigadas como possíveis fatores de risco para biópsias de próstata: idade, câncer da próstata, diabetes melito, hipertensão arterial sistêmica, antecedentes de prostatite, uso de ácido acetilsalicílico, volume prostático, número de biópsias e uso de sonda vesical. RESULTADOS: As complicações hemorrágicas foram mais comuns (75,3%) enquanto que as infecciosas ocorreram em 19% dos casos. O tipo mais freqüente foi a hematúria, ocorrendo em 56% dos pacientes. A infecção do trato urinário ocorreu em 16 pacientes (9,2%). Sepse foi observada em três pacientes (1,7%). Não houve óbitos. em 20% dos pacientes não foram observadas complicações após o exame. A presença da sonda vesical foi fator de risco para complicações infecciosas (p < 0,05). O número maior de amostras nas biópsias foi relacionado à hematúria, sangramento retal e complicações infecciosas (p < 0,05). As demais condições investigadas não se relacionaram com complicações pós-biópsia da próstata. CONCLUSÕES: As complicações pós-biópsia da próstata foram em sua maioria autolimitadas. A taxa de complicações graves foi baixa, sendo a biópsia de próstata guiada pelo ultra-som segura e eficaz. A retirada de um maior número de fragmentos na biópsia relaciona-se com hematúria, sangramento retal e complicações infecciosas. A sonda vesical foi um fator de risco para complicações infecciosas.