999 resultados para Ultra cold quantum gases


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Precipitation of FeTiP is reported to occur in Ti-added IF steels containing high P during thermomechanical processing. An ultra-low carbon (ULC) Nb-added steel ingot containing a higher P content (< 0.8 wt-%) was produced via aluminothermic reduction of Fe2O3 followed by double electron beam melting (EBM). FeNbP coarse precipitates were observed in the as-cast microstructure. After soaking at 1050C for 1 h, the plate was hot rolled from 31 mm down to 7 mm in thickness (total reduction of 77%). During cold rolling of these hot bands we observed embrittlement. We believe that this embrittlement can be attributed to the presence of the FeNbP precipitates. Light optical and scanning electron microscopy (SEM/EDS) were used to characterize the microstructure of this ULC steel. (C) 2000 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: em pacientes sob intubação traqueal ou traqueostomia, a umidificação e o aquecimento do gás inalado são necessários para a prevenção de lesões no sistema respiratório, conseqüentes ao contato do gás frio e seco com as vias aéreas. O objetivo da pesquisa foi avaliar o efeito do sistema respiratório circular com absorvedor de dióxido de carbono do aparelho de anestesia Cícero da Dräger, quanto à capacidade de aquecimento e umidificação dos gases inalados, utilizando-se fluxo baixo (1 L.min-1) ou mínimo (0,5 L.min-1) de gases frescos. MÉTODO: O estudo aleatório foi realizado em 24 pacientes, estado físico ASA I, com idades entre 18 e 65 anos, submetidos à anestesia geral, utilizando-se a Estação de Trabalho Cícero da Dräger (Alemanha), para realização de cirurgias abdominais, os quais foram distribuídos aleatoriamente em dois grupos: grupo de Baixo Fluxo (BF), no qual foi administrado 0,5 L.min-1 de oxigênio e 0,5 L.min-1 de óxido nitroso e fluxo mínimo (FM), administrando-se somente oxigênio a 0,5 L.min-1. Os atributos estudados foram temperatura, umidade relativa e absoluta da sala de operação e do gás no sistema inspiratório. RESULTADOS: Os valores da temperatura, umidade relativa e umidade absoluta no sistema inspiratório na saída do aparelho de anestesia e junto ao tubo traqueal não apresentaram diferença significante entre os grupos, mas aumentaram ao longo do tempo nos dois grupos (BF e FM), havendo influência da temperatura da sala de operação sobre a temperatura do gás inalado, nos dois grupos estudados. Níveis de umidade e temperatura próximos dos ideais foram alcançados, nos dois grupos, a partir de 90 minutos. CONCLUSÕES: Não há diferença significante da umidade e temperatura do gás inalado utilizando-se baixo fluxo e fluxo mínimo de gases frescos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Poincar, group generalizes the Galilei group for high-velocity kinematics. The de Sitter group is assumed to go one step further, generalizing Poincar, as the group governing high-energy kinematics. In other words, ordinary special relativity is here replaced by de Sitter relativity. In this theory, the cosmological constant I > is no longer a free parameter, and can be determined in terms of other quantities. When applied to the whole universe, it is able to predict the value of I > and to explain the cosmic coincidence. When applied to the propagation of ultra-high energy photons, it gives a good estimate of the time delay observed in extragalactic gamma-ray flares. It can, for this reason, be considered a new paradigm to approach the quantum gravity problem.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Comparar e avaliar experimentalmente as alterações estruturais e ultra-estruturais em corações hipertrofiados isolados de coelhos submetidos à parada protegida pela solução de cardioplegia sangüínea e cardioplegia cristalóide. MÉTODO: O estudo compreendeu um grupo controle e dois grupos experimentais. No grupo I, a parada cardíaca foi obtida pela infusão da solução de cardioplegia sangüínea contínua e tépida. No grupo II, a parada cardíaca foi conseguida pela infusão da solução de cardioplegia cristalóide intermitente e fria. No grupo controle, os corações foram submetidos à parada anóxia normotérmica por 45 minutos. Após experimentos, oito amostras da parede lateral do ventrículo esquerdo foram coletadas e fixadas em formaldeído 10% e glutaraldeído 2,5% para análises estrutural e ultra-estrutural. RESULTADOS: Os resultados estruturais e as descrições ultra-estruturais mostraram que os corações submetidos à parada protegida pela cardioplegia sangüínea contínua e tépida (grupo I) estavam mais preservados com alterações celulares menos acentuadas se comparados aos submetidos à parada protegida pela cardioplegia cristalóide intermitente e fria (grupo II) e ao grupo controle. CONCLUSÃO: A cardioplegia sangüínea contínua e tépida (Grupo I) foi mais eficiente na preservação da integridade estrutural e ultra-estrutural do miocárdio, quando comparada à cardioplegia cristalóide intermitente e fria (Grupo II).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The steel type AISI 4130 (ultra-high strength steel) is an alloy of low carbon and its main alloying elements are chromium and molybdenum, which improves the toughness of the weld metal. It has numerous applications, especially where the need for high mechanical strength. It is widely used in equipment used by the aviation industry, such as cradle-tomotor, and this is the motivation for this study. Cots are of fundamental importance, because the engine supports and maintains balance in the fixed landing gear. This equipment is subjected to intense loading cycles, whose fractures caused by fatigue are constantly observed. Will be determined the effects caused by re-welding the structure of aeronautical equipment, and will also study the microstructure of the metal without welding. The studies will be done on materials used in aircraft, which was given to study. The results provide knowledge of microstructure to evaluate any type of fracture that maybe caused by fatigue. Fatigue is a major cause of aircraft accidents and incidents occurred, which makes the study of the microstructure of the metal, weld and re-solder the knowledge essential to the life of the material. The prevention and control of the process of fatigue in aircraft are critical, since the components are subjected to greater responsibility cyclic loading

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, we propose the nonlocal tunneling mechanism for high-fidelity state transfer between distant parties. The nonlocal tunneling follows from the overlap between the distant sending and receiving wave functions, which is indirectlymediated by the off-resonant normal modes of a quantum channel. This channel is made up of a network of dissipative quantum systems exhibiting the same bosonic or fermionic statistical nature as the sender and receiver. We demonstrate that the incoherence arising from quantum channel nonidealities is almost completely circumvented by the tunneling mechanism, which thus affords a high-fidelity transfer process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[EN] The main types of submarine geological emissions are classified as cold seeps (hydrocarbons and brines) and hot vents. These processes result in the emission of geological fluids: brine, gases (mainly hydro-carbons), sediments and rocks. Submarine emissions are associated with an intensive geological, geo-chemical, thermal and biological activity (Judd and Hovland, 2007), and constitute a key process in the dynamics of the global cycles of the planet Earth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the discovery of the nuclear magnetic resonance (NMR) phenomenon, countless NMR techniques have been developed that are today indispensable tools in physics, chemistry, biology, and medicine. As one of the main obstacles in NMR is its notorious lack of sensitivity, different hyperpolarization (HP) methods have been established to increase signals up to several orders of magnitude. In this work, different aspects of magnetic resonance, using HP noble gases, are studied, hereby combining different disciplines of research. The first part examines new fundamental effects in NMR of HP gases, in theory and experiment. The spin echo phenomenon, which provides the basis of numerous modern experiments, is studied in detail in the gas phase. The changes of the echo signal in terms of amplitude, shape, and position, due to the fast translational motion, are described by an extension of the existing theory and computer simulations. With this knowledge as a prerequisite, the detection of intermolecular double-quantum coherences was accomplished for the first time in the gas phase. The second part of this thesis focuses on the development of a practical method to enhance the dissolution process of HP 129Xe, without loss of polarization or shortening of T1. Two different setups for application in NMR spectroscopy and magnetic resonance imaging (MRI) are presented. The continuous operation allows biological and multidimensional spectroscopy in solutions. Also, first in vitro MRI images with dissolved HP 129Xe as contrast agent were obtained at a clinical scanner.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of Magnetic Resonance Imaging (MRI) as a diagnostic tool is increasingly employing functional contrast agents to study or contrast entire mechanisms. Contrast agents in MRI can be classified in two categories. One type of contrast agents alters the NMR signal of the protons in its surrounding, e.g. lowers the T1 relaxation time. The other type enhances the Nuclear Magnetic Resonance (NMR) signal of specific nuclei. For hyperpolarized gases the NMR signal is improved up to several orders of magnitude. However, gases have a high diffusivity which strongly influences the NMR signal strength, hence the resolution and appearance of the images. The most interesting question in spatially resolved experiments is of course the achievable resolution and contrast by controlling the diffusivity of the gas. The influence of such diffusive processes scales with the diffusion coefficient, the strength of the magnetic field gradients and the timings used in the experiment. Diffusion may not only limit the MRI resolution, but also distort the line shape of MR images for samples, which contain boundaries or diffusion barriers within the sampled space. In addition, due to the large polarization in gaseous 3He and 129Xe, spin diffusion (different from particle diffusion) could play a role in MRI experiments. It is demonstrated that for low temperatures some corrections to the NMR measured diffusion coefficient have to be done, which depend on quantum exchange effects for indistinguishable particles. Physically, if these effects can not change the spin current, they can do it indirectly by modifying the velocity distribution of the different spin states separately, so that the subsequent collisions between atoms and therefore the diffusion coefficient can eventually be affected. A detailed study of the hyperpolarized gas diffusion coefficient is presented, demonstrating the absence of spin diffusion (different from particle diffusion) influence in MRI at clinical conditions. A novel procedure is proposed to control the diffusion coefficient of gases in MRI by admixture of inert buffer gases. The experimental measured diffusion agrees with theoretical simulations. Therefore, the molecular mass and concentration enter as additional parameters into the equations that describe structural contrast. This allows for setting a structural threshold up to which structures contribute to the image. For MRI of the lung this allows for images of very small structural elements (alveoli) only, or in the other extreme, all airways can be displayed with minimal signal loss due to diffusion.