973 resultados para Surface Electromyography


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study, using surface electromyography, analyzed the activity of the masseter muscles of 30 patients with facial bone fractures that were surgically treated. Evaluations were made before surgery and in the 7th, 30th, and 60th days after surgery. The value of each measure and the average of 3 maximum voluntary isometric contractions lasting 5 seconds each were registered, and statistical analyses were performed. Patients had a mean age of 31 years and an average of 1.33 fractures. They were grouped according to the type of fracture as follows: mandibular (50%), zygomatic complex (33%), maxilla (10%), and associated fractures (6.7%). There was a lower masseter activity in the preoperative period, when compared with normal values in all groups of fractures. There was a sharp drop in the masseter activity in the postoperative period of 7 days, and all groups showed recovery of activity in 60 days but still below the normal value referenced in the literature. The mean values of the masseter activity, in descending order, were from the zygomatic complex, mandibular, maxillary, and associated fractures. The unilateral mandibular fractures showed higher values than the bilateral fractures in most of the evaluations. There was a highly significant difference in the comparison of the evolution of the masseter activity on both sides, for mandibular and zygomatic complex fractures, and the pairwise comparison showed significant difference between most groups. It was concluded that facial fractures and surgical procedures had negative effects in the muscle activity as observed using electromyography.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study examined whether there is an association between surface electromyography (EMG) of masticatory muscles, orofacial myofunction status and temporomandibular disorder (TMD) severity scores. Forty-two women with TMD (mean 30 years, SD 8) and 18 healthy women (mean 26 years, SD 6) were examined. According to the Research Diagnostic Criteria for TMD (RDC/TMD), all patients had myogenous disorders plus disk displacements with reduction. Surface EMG of masseter and temporal muscles was performed during maximum teeth clenching either on cotton rolls or in intercuspal position. Standardized EMG indices were obtained. Validated protocols were used to determine the perception severity of TMD and to assess orofacial myofunctional status. TMD patients showed more asymmetry between right and left muscle pairs, and more unbalanced contractile activities of contralateral masseter and temporal muscles (p < 0.05, t-test), worse orofacial myofunction status and higher TMD severity scores (p < 0.05, Mann-Whitney test) than healthy subjects. Spearman coefficient revealed significant correlations between EMG indices, orofacial myofunctional status and TMD severity (p < 0.05). In conclusion, these methods will provide useful information for TMD diagnosis and future therapeutic planning. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo deste estudo foi analisar a reprodutibilidade de parâmetros no domínio da frequência do sinal eletromiográfico (EMG) utilizados na caracterização da fadiga muscular localizada. Quinze sujeitos do sexo masculino foram submetidos a um teste de fadiga baseado na extensão isométrica de joelho, sendo realizados em três momentos distintos com intervalos de sete dias. Para avaliar a reprodutibilidade dos dados entres os testes calculou-se o coeficiente de correlação intraclasse (CCI) para a frequência mediana (Fmed) no tempo total de exercício (FmedT), para a Fmed obtida a cada 10% do tempo de exercício (Fmed10%) e para as potências das bandas de frequência, obtidas da divisão do espectro de potência a cada 20 Hz. Os resultados demonstraram: (1) boa reprodutibilidade para a FmedT; (2) boa reprodutibilidade para a Fmed10%; e (3) maior variação no sinal EMG nas bandas de 20 a 120 Hz, no qual se destacam as bandas de 20-40 Hz e de 40-60 Hz, demonstrando maior sensibilidade ao processo de fadiga muscular. Conclui-se que a Fmed é uma variável que apresenta boa reprodutibilidade e que a análise fragmentada do espectro de potência, por meio das bandas de frequência, demonstrou-se sensível as variações que ocorrem no sinal EMG durante a instalação do processo de fadiga, tendo potencial para se tornar um novo método para a caracterização da fadiga muscular localizada.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abstract Background This study compares the immediate effects of local and adjacent acupuncture on the tibialis anterior muscle and the amount of force generated or strength in Kilogram Force (KGF) evaluated by a surface electromyography. Methods The study consisted of a single blinded trial of 30 subjects assigned to two groups: local acupoint (ST36) and adjacent acupoint (SP9). Bipolar surface electrodes were placed on the tibialis anterior muscle, while a force transducer was attached to the foot of the subject and to the floor. An electromyograph (EMG) connected to a computer registered the KGF and root mean square (RMS) before and after acupuncture at maximum isometric contraction. The RMS values and surface electrodes were analyzed with Student's t-test. Results Thirty subjects were selected from a total of 56 volunteers according to specific inclusion and exclusion criteria and were assigned to one of the two groups for acupuncture. A significant decrease in the RMS values was observed in both ST36 (t = -3.80, P = 0,001) and SP9 (t = 6.24, P = 0.001) groups after acupuncture. There was a decrease in force in the ST36 group after acupuncture (t = -2.98, P = 0.006). The RMS values did not have a significant difference (t = 0.36, P = 0.71); however, there was a significant decrease in strength after acupuncture in the ST36 group compared to the SP9 group (t = 2.51, P = 0.01). No adverse events were found. Conclusion Acupuncture at the local acupoint ST36 or adjacent acupoints SP9 reduced the tibialis anterior electromyography muscle activity. However, acupuncture at SP9 did not decrease muscle strength while acupuncture at ST36 did.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Human reactions to vibration have been extensively investigated in the past. Vibration, as well as whole-body vibration (WBV), has been commonly considered as an occupational hazard for its detrimental effects on human condition and comfort. Although long term exposure to vibrations may produce undesirable side-effects, a great part of the literature is dedicated to the positive effects of WBV when used as method for muscular stimulation and as an exercise intervention. Whole body vibration training (WBVT) aims to mechanically activate muscles by eliciting neuromuscular activity (muscle reflexes) via the use of vibrations delivered to the whole body. The most mentioned mechanism to explain the neuromuscular outcomes of vibration is the elicited neuromuscular activation. Local tendon vibrations induce activity of the muscle spindle Ia fibers, mediated by monosynaptic and polysynaptic pathways: a reflex muscle contraction known as the Tonic Vibration Reflex (TVR) arises in response to such vibratory stimulus. In WBVT mechanical vibrations, in a range from 10 to 80 Hz and peak to peak displacements from 1 to 10 mm, are usually transmitted to the patient body by the use of oscillating platforms. Vibrations are then transferred from the platform to a specific muscle group through the subject body. To customize WBV treatments, surface electromyography (SEMG) signals are often used to reveal the best stimulation frequency for each subject. Use of SEMG concise parameters, such as root mean square values of the recordings, is also a common practice; frequently a preliminary session can take place in order to discover the more appropriate stimulation frequency. Soft tissues act as wobbling masses vibrating in a damped manner in response to mechanical excitation; Muscle Tuning hypothesis suggest that neuromuscular system works to damp the soft tissue oscillation that occurs in response to vibrations; muscles alters their activity to dampen the vibrations, preventing any resonance phenomenon. Muscle response to vibration is however a complex phenomenon as it depends on different parameters, like muscle-tension, muscle or segment-stiffness, amplitude and frequency of the mechanical vibration. Additionally, while in the TVR study the applied vibratory stimulus and the muscle conditions are completely characterised (a known vibration source is applied directly to a stretched/shortened muscle or tendon), in WBV study only the stimulus applied to a distal part of the body is known. Moreover, mechanical response changes in relation to the posture. The transmissibility of vibratory stimulus along the body segment strongly depends on the position held by the subject. The aim of this work was the investigation on the effects that the use of vibrations, in particular the effects of whole body vibrations, may have on muscular activity. A new approach to discover the more appropriate stimulus frequency, by the use of accelerometers, was also explored. Different subjects, not affected by any known neurological or musculoskeletal disorders, were voluntarily involved in the study and gave their informed, written consent to participate. The device used to deliver vibration to the subjects was a vibrating platform. Vibrations impressed by the platform were exclusively vertical; platform displacement was sinusoidal with an intensity (peak-to-peak displacement) set to 1.2 mm and with a frequency ranging from 10 to 80 Hz. All the subjects familiarized with the device and the proper positioning. Two different posture were explored in this study: position 1 - hack squat; position 2 - subject standing on toes with heels raised. SEMG signals from the Rectus Femoris (RF), Vastus Lateralis (VL) and Vastus medialis (VM) were recorded. SEMG signals were amplified using a multi-channel, isolated biomedical signal amplifier The gain was set to 1000 V/V and a band pass filter (-3dB frequency 10 - 500 Hz) was applied; no notch filters were used to suppress line interference. Tiny and lightweight (less than 10 g) three-axial MEMS accelerometers (Freescale semiconductors) were used to measure accelerations of onto patient’s skin, at EMG electrodes level. Accelerations signals provided information related to individuals’ RF, Biceps Femoris (BF) and Gastrocnemius Lateralis (GL) muscle belly oscillation; they were pre-processed in order to exclude influence of gravity. As demonstrated by our results, vibrations generate peculiar, not negligible motion artifact on skin electrodes. Artifact amplitude is generally unpredictable; it appeared in all the quadriceps muscles analysed, but in different amounts. Artifact harmonics extend throughout the EMG spectrum, making classic high-pass filters ineffective; however, their contribution was easy to filter out from the raw EMG signal with a series of sharp notch filters centred at the vibration frequency and its superior harmonics (1.5 Hz wide). However, use of these simple filters prevents the revelation of EMG power potential variation in the mentioned filtered bands. Moreover our experience suggests that the possibility of reducing motion artefact, by using particular electrodes and by accurately preparing the subject’s skin, is not easily viable; even though some small improvements were obtained, it was not possible to substantially decrease the artifact. Anyway, getting rid of those artifacts lead to some true EMG signal loss. Nevertheless, our preliminary results suggest that the use of notch filters at vibration frequency and its harmonics is suitable for motion artifacts filtering. In RF SEMG recordings during vibratory stimulation only a little EMG power increment should be contained in the mentioned filtered bands due to synchronous electromyographic activity of the muscle. Moreover, it is better to remove the artifact that, in our experience, was found to be more than 40% of the total signal power. In summary, many variables have to be taken into account: in addition to amplitude, frequency and duration of vibration treatment, other fundamental variables were found to be subject anatomy, individual physiological condition and subject’s positioning on the platform. Studies on WBV treatments that include surface EMG analysis to asses muscular activity during vibratory stimulation should take into account the presence of motion artifacts. Appropriate filtering of artifacts, to reveal the actual effect on muscle contraction elicited by vibration stimulus, is mandatory. However as a result of our preliminary study, a simple multi-band notch filtering may help to reduce randomness of the results. Muscle tuning hypothesis seemed to be confirmed. Our results suggested that the effects of WBV are linked to the actual muscle motion (displacement). The greater was the muscle belly displacement the higher was found the muscle activity. The maximum muscle activity has been found in correspondence with the local mechanical resonance, suggesting a more effective stimulation at the specific system resonance frequency. Holding the hypothesis that muscle activation is proportional to muscle displacement, treatment optimization could be obtained by simply monitoring local acceleration (resonance). However, our study revealed some short term effects of vibratory stimulus; prolonged studies should be assembled in order to consider the long term effectiveness of these results. Since local stimulus depends on the kinematic chain involved, WBV muscle stimulation has to take into account the transmissibility of the stimulus along the body segment in order to ensure that vibratory stimulation effectively reaches the target muscle. Combination of local resonance and muscle response should also be further investigated to prevent hazards to individuals undergoing WBV treatments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The study of optic flow on postural control may explain how self-motion perception contributes to postural stability in young males and females and how such function changes in the old falls risk population. Study I: The aim was to examine the optic flow effect on postural control in young people (n=24), using stabilometry and surface-electromyography. Subjects viewed expansion and contraction optic flow stimuli which were presented full field, in the foveral or in the peripheral visual field. Results showed that optic flow stimulation causes an asymmetry in postural balance and a different lateralization of postural control in men and women. Gender differences evoked by optic flow were found both in the muscle activity and in the prevalent direction of oscillation. The COP spatial variability was reduced during the view of peripheral stimuli which evoked a clustered prevalent direction of oscillation, while foveal and random stimuli induced non-distributed directions. Study II was aimed at investigating the age-related mechanisms of postural stability during the view of optic flow stimuli in young (n=17) and old (n=19) people, using stabilometry and kinematic. Results showed that old people showed a greater effort to maintain posture during the view of optic flow stimuli than the young. Elderly seems to use the head stabilization on trunk strategy. Visual stimuli evoke an excitatory input on postural muscles, but the stimulus structure produces different postural effects. Peripheral optic flow stabilizes postural sway, while random and foveal stimuli provoke larger sway variability similar to those evoked in baseline. Postural control uses different mechanisms within each leg to produce the appropriate postural response to interact with extrapersonal environment. Ageing reduce the effortlessness to stabilize posture during optic flow, suggesting a neuronal processing decline associated with difficulty integrating multi-sensory information of self-motion perception and increasing risk of falls.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To assess the effects of a single intravenous dose of butorphanol (0.1 mg kg(-1)) on the nociceptive withdrawal reflex (NWR) using threshold, suprathreshold and repeated subthreshold electrical stimuli in conscious horses. STUDY DESIGN: 'Unblinded', prospective experimental study. ANIMALS: Ten adult horses, five geldings and five mares, mean body mass 517 kg (range 487-569 kg). METHODS: The NWR was elicited using single transcutaneous electrical stimulation of the palmar digital nerve. Repeated stimulations were applied to evoke temporal summation. Surface electromyography was performed to record and quantify the responses of the common digital extensor muscle to stimulation and behavioural reactions were scored. Before butorphanol administration and at fixed time points up to 2 hours after injection, baseline threshold intensities for NWR and temporal summation were defined and single suprathreshold stimulations applied. Friedman repeated-measures analysis of variance on ranks and Wilcoxon signed-rank test were used with the Student-Newman-Keul's method applied post-hoc. The level of significance (alpha) was set at 0.05. RESULTS: Butorphanol did not modify either the thresholds for NWR and temporal summation or the reaction scores, but the difference between suprathreshold and threshold reflex amplitudes was reduced when single stimulation was applied. Upon repeated stimulation after butorphanol administration, a significant decrease in the relative amplitude was calculated for both the 30-80 and the 80-200 millisecond intervals after each stimulus, and for the whole post-stimulation interval in the right thoracic limb. In the left thoracic limb a decrease in the relative amplitude was found only in the 30-80 millisecond epoch. CONCLUSION: Butorphanol at 0.1 mg kg(-1) has no direct action on spinal Adelta nociceptive activity but may have some supraspinal effects that reduce the gain of the nociceptive system. CLINICAL RELEVANCE: Butorphanol has minimal effect on sharp immediate Adelta-mediated pain but may alter spinal processing and decrease the delayed sensations of pain.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

During locomotion, turning is a common and recurring event which is largely neglected in the current state-of-the-art ankle-foot prostheses, forcing amputees to use different steering mechanisms for turning, compared to non-amputees. A better understanding of the complexities surrounding lower limb prostheses will lead to increased health and well-being of amputees. The aim of this research is to develop a steerable ankle-foot prosthesis that mimics the human ankle mechanical properties. Experiments were developed to estimate the mechanical impedance of the ankle and the ankles angles during straight walk and step turn. Next, this information was used in the design of a prototype, powered steerable ankle-foot prosthesis with two controllable degrees of freedom. One of the possible approaches in design of the prosthetic robots is to use the human joints’ parameters, especially their impedance. A series of experiments were conducted to estimate the stochastic mechanical impedance of the human ankle when muscles were fully relaxed and co-contracting antagonistically. A rehabilitation robot for the ankle, Anklebot, was employed to provide torque perturbations to the ankle. The experiments were performed in two different configurations, one with relaxed muscles, and one with 10% of maximum voluntary contraction (MVC). Surface electromyography (sEMG) was used to monitor muscle activation levels and these sEMG signals were displayed to subjects who attempted to maintain them constant. Time histories of ankle torques and angles in the lateral/medial (LM) directions, inversion-eversion (IE), and dorsiflexionplantarflexion (DP) were recorded. Linear time-invariant transfer functions between the measured torques and angles were estimated providing an estimate of ankle mechanical impedance. High coherence was observed over a frequency range up to 30 Hz. The main effect of muscle activation was to increase the magnitude of ankle mechanical impedance in all degrees of freedom of the ankle. Another experiment compared the three-dimensional angles of the ankle during step turn and straight walking. These angles were measured to be used for developing the control strategy of the ankle-foot prosthesis. An infrared camera system was used to track the trajectories and angles of the foot and leg. The combined phases of heel strike and loading response, mid stance, and terminal stance and pre-swing were determined and used to measure the average angles at each combined phase. The Range of motion (ROM) in IE increased during turning while ML rotation decreased and DP changed the least. During the turning step, ankle displacement in DP started with similar angles to straight walk and progressively showed less plantarflexion. In IE, the ankle showed increased inversion leaning the body toward the inside of the turn. ML rotation initiated with an increased medial rotation during the step turn relative to the straight walk transitioning to increased lateral rotation at the toe off. A prototype ankle-foot prosthesis capable of controlling both DP and IE using a cable driven mechanism was developed and assessed as part of a feasibility study. The design is capable of reproducing the angles required for straight walk and step turn; generates 712N of lifting force in plantarflexion, and shows passive stiffness comparable to a nonload bearing ankle impedance. To evaluate the performance of the ankle-foot prosthesis, a circular treadmill was developed to mimic human gait during steering. Preliminary results show that the device can appropriately simulate human gait with loading and unloading the ankle joint during the gait in circular paths.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: To investigate the modulation of the nociceptive withdrawal reflex (NWR) and temporal summation (TS) by low-dose acepromazine (ACP) in conscious dogs. To assess the short- and long-term stability of the reflex thresholds. STUDY DESIGN: Randomized, blinded, placebo-controlled cross-over experimental study. ANIMALS: Eight adult male Beagles. METHODS: The NWR was elicited using single transcutaneous electrical stimulation of the ulnar nerve. Repeated stimuli (10 pulses, 5 Hz) were applied to evoke TS. The responses of the deltoideus muscle were recorded and quantified by surface electromyography and the behavioural reactions were scored. Each dog received 0.01 mg kg(-1) ACP or an equal volume saline intravenously (IV) at 1 week intervals. Measurements were performed before (baseline) and 20, 60 and 100 minutes after drug administration. Sedation was scored before drug administration and then at 10 minutes intervals. Data were analyzed with Friedman repeated measures analysis of variance on ranks and Wilcoxon signed rank tests. RESULTS: Acepromazine resulted in a mild tranquilization becoming obvious at 20 minutes and peaking 30 minutes after injection. Single (I(t)) and repeated stimuli (TS(t)) threshold intensities, NWR and TS characteristics and behavioural responses were not affected by the ACP at any time point. Both I(t) and TS(t) were stable over time. CONCLUSIONS AND CLINICAL RELEVANCE: In dogs, 0.01 mg kg(-1) ACP IV had no modulatory action on the NWR evoked by single or repeated stimuli, suggesting no antinociceptive activity on phasic nociceptive stimuli. The evidence of the stability of the NWR thresholds supports the use of the model as an objective tool to investigate nociception in conscious dogs. A low dose of ACP administered as the sole drug, can be used to facilitate the recordings in anxious subjects without altering the validity of this model.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study quantitatively investigated the analgesic action of a low-dose constant-rate-infusion (CRI) of racemic ketamine (as a 0.5 mg kg(-1) bolus and at a dose rate of 10 microg kg(-1) min(-1)) in conscious dogs using a nociceptive withdrawal reflex (NWR) and with enantioselective measurement of plasma levels of ketamine and norketamine. Withdrawal reflexes evoked by transcutaneous single and repeated electrical stimulation (10 pulses, 5 Hz) of the digital plantar nerve were recorded from the biceps femoris muscle using surface electromyography. Ketamine did not affect NWR thresholds or the recruitment curves after a single nociceptive stimulation. Temporal summation (as evaluated by repeated stimuli) and the evoked behavioural response scores were however reduced compared to baseline demonstrating the antinociceptive activity of ketamine correlated with the peak plasma concentrations. Thereafter the plasma levels at pseudo-steady-state did not modulate temporal summation. Based on these experimental findings low-dose ketamine CRI cannot be recommended for use as a sole analgesic in the dog.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to characterize the nociceptive withdrawal reflex (NWR) and to define the nociceptive threshold in 25 healthy, non-medicated experimental sheep in standing posture. Electrical stimulation of the dorsal lateral digital nerves of the right thoracic and the pelvic limb was performed and surface-electromyography (EMG) from the deltoid (all animals) and the femoral biceps (18 animals) or the peroneus tertius muscles (7 animals) was recorded. The behavioural reaction following each stimulation was scored on a scale from 0 (no reaction) to 5 (strong whole body reaction). A train-of-five 1 ms constant-current pulse was used and current intensity was stepwise increased until NWR threshold intensity was reached. The NWR threshold intensity (It) was defined as the minimal stimulus intensity able to evoke a reflex with a minimal Root-Mean-Square amplitude (RMSA) of 20 μV, a minimal duration of 10 ms and a minimal reaction score of 1 (slight muscle contraction of the stimulated limb) within the time window of 20 to 130 ms post-stimulation. Based on this value, further stimulations were performed below (0.9It) and above threshold (1.5It and 2It). The stimulus-response curve was described. Data are reported as medians and interquartile ranges. At the deltoid muscle It was 4.4 mA (2.9–5.7) with an RMSA of 62 μV (30–102). At the biceps femoris muscle It was 7.0 mA (4.0–10.0) with an RMSA of 43 μV (34–50) and at the peroneus tertius muscle It was 3.4 mA (3.1–4.4) with an RMSA of 38 μV (32–46). Above threshold, RMSA was significantly increased at all muscles. Below threshold, RMSA was only significantly smaller than at It for the peroneus tertius muscle but not for the other muscles.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Generalized joint hypermobility (GJH) is a frequent entity in rheumatology with higher prevalence among women. It is associated with chronic widespread pain, joint dislocations, arthralgia, fibromyalgia and early osteoarthritis. Stair climbing is an important functional task and can induce symptoms in hypermobile persons. The aim of this study was to compare ground reaction forces (GRF) and muscle activity during stair climbing in women with and without GJH. A cross-sectional study of 67 women with normal mobility and 128 hypermobile women was performed. The hypermobile women were further divided into 56 symptomatic and 47 asymptomatic. GRFs were measured by force plates embedded in a six step staircase, as well as surface electromyography (EMG) of six leg muscles. Parameters derived from GRF and EMG were compared between groups using t-test and ANOVA. For GRF no significant differences were found. EMG showed lower activity for the quadriceps during ascent and lower activity for hamstrings and quadriceps during descent in hypermobile women. For symptomatic hypermobile women these differences were even more accentuated. The differences in EMG may point towards an altered movement pattern during stair climbing, aimed at avoiding high muscle activation. However, differences were small, since stair climbing seems to be not demanding.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introdução: A DPOC é uma doença respiratória prevenível e tratável, caracterizada por limitação persistente ao fluxo aéreo, hiperinsuflação e aprisionamento aéreo. A dispneia e a intolerância aos esforços, decorrentes destas alterações fisiopatológicas sofre influência de vários fatores. Dentre estes, o recrutamento e a sobrecarga imposta aos músculos inspiratórios e expiratórios são de fundamental importância, porém a participação destes ainda não foi completamente elucidada em diferentes gravidades da doença. Objetivos: O objetivo principal deste estudo foi avaliar a mecânica ventilatória, e o grau de recrutamento da musculatura inspiratória e expiratória na DPOC leve e grave, na condição de repouso e durante um teste máximo de exercício, comparado a um grupo de indivíduos saudáveis. Metodologia: Trata-se de um estudo transversal envolvendo 36 indivíduos, sendo 24 pacientes portadores de DPOC e 12 voluntários sadios. As avaliações foram divididas em 2 visitas. No D1, foram realizadas uma avaliação clínica, avaliação de dispneia (mMRC) e de qualidade de vida (SGRQ), além da prova de função pulmonar completa. Na 2ª visita, realizada com intervalo de 1 semana, foram avaliadas: as pressões respiratórias máximas estáticas por meio de métodos volitivos (PImax, PEmax, SNIP, Pes sniff, Pga sniff e Pdi sniff) e não volitivos (Twitch cervical bilateral e T10); avaliação da sincronia toracoabdominal por pletismografia de indutância; avaliação do recrutamento dos músculos inspiratórios e expiratórios ao repouso pela eletromiografia de superfície; e, posteriormente, um teste de exercício cardiopulmonar incremental para estudo de todas essas variáveis no esforço. Resultados: Foram avaliados 24 pacientes (12 leves e 12 graves) e 12 indivíduos saudáveis da mesma faixa etária. A maioria dos pacientes apresentava comprometimento significativo da qualidade de vida e os pacientes do grupo grave eram mais sintomáticos. A função pulmonar encontrava-se alterada na maioria dos pacientes. Destes, 79,2% apresentavam aprisionamento aéreo e 70,8% tinham redução da DLCO. Tais alterações foram semelhantes nos 2 grupos de pacientes. A força muscular estática medida por métodos volitivos e não volitivos estava reduzida nos 2 grupos e mostrou relação com o VEF1. No exercício, a dispneia foi o principal motivo para interrupção do teste em 70% dos pacientes. A HD esteve presente em 87,5% dos pacientes. O comportamento das pressões respiratórias foi significativamente diferente entre os 3 grupos. Os pacientes com DPOC apresentaram maior atividade diafragmática (Pdi) comparado aos controles e a participação da musculatura expiratória também foi maior neste grupo, principalmente nos graves. Apesar disso, os pacientes com DPOC apresentaram uma eficiência mecânica reduzida, ou seja, esse incremento da força muscular foi insuficiente para manter uma ventilação adequada para uma determinada carga. Com o aumento da demanda ventilatória, houve recrutamento precoce e progressivo dos músculos inspiratórios e expiratórios durante o exercício. O trabalho resistivo e o expiratório foram significativamente diferentes entre os controles e os pacientes com DPOC desde o início do exercício. Como consequência destas alterações, a intensidade da dispneia durante o TECP foi maior nos pacientes com DPOC (leve e grave) para a mesma carga e mesma ventilação-minuto (VE), quando comparada aos indivíduos do grupo-controle. Conclusões: O conjunto destes achados demonstra que o comprometimento dos músculos inspiratórios e expiratórios contribuiu significativamente para a dispneia e a intolerância ao exercício tanto no DPOC leve quanto no DPOC grave. E que este comprometimento pode não ser detectado com os testes máximos de força ao repouso

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Exercise interventions are deemed essential for the effective management of patients with neck pain. However, there has been a lack of consensus on optimal exercise prescription, which has resulted from a paucity of studies to quantify the precise nature of muscle impairment, in people with neck pain. This masterclass will present recent research from our laboratory, which has utilized surface electromyography to investigate cervical flexor muscle impairment in patients with chronic neck pain. This research has identified deficits in the motor control of the deep and superficial cervical flexor muscles in people with chronic neck pain, characterized by a delay in onset of neck muscle contraction associated with movement of the upper limb. In addition, people with neck pain demonstrate an altered pattern of muscle activation, which is characterized by reduced deep cervical flexor muscle activity during a low load cognitive task and increased activity of the superficial cervical flexor muscles during both cognitive tasks and functional activities. The results have demonstrated the complex, multifaceted nature of cervical muscle impairment, which exists in people with a history of neck pain. In turn, this has considerable implications for the rehabilitation of muscle function in people with neck pain disorders. (C) 2004 Elsevier Ltd. All rights reserved.