996 resultados para Spectrophotometer


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two simple and sensitive spectrophotometric methods (A and B)in the visible region have been developed for the determination of nimesulide in bulk and in dosage forms.Method A is based on the reaction of reduced nimesulide with nitrous acid followed by its coupling with phloroglucinol to yield an yellow colored azo dye with an absorption maximum of 400 nm and method B is based on the reaction of reduced nimesulide with p-dimethylamino benzaldehyde(PDAB) to form an yellow colored chromogen wiht an absorption maximum of 415 nm.When pharmaceutical preparations (Tablets and suspension) were analysed, the results obtained by the proposed methods are in good agreement with the labelled amounts and are comparable with the results obtained by a reported method.recovery in both the method is 98-101 %.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dependence of energy transfer parameters on excitation wavelength has been investigated in poly (methyl methacrylate) (PMMA) optical fibre preforms doped with C 540:Rh B dye mixture by studying the fluorescence intensity and the lifetime variations. A fluorescence spectrophotometer was used to record the excitation spectra of the samples for the emission wavelengths 495 and 580 nm. The fluorescence emission from the polymer rods was studied at four specific excitation wavelengths viz; 445, 465, 488 and 532 nm. The fluorescence lifetime of the donor molecule was experimentally measured in polymer matrix by time correlated single photon counting technique. The energy transfer rate constants and transfer efficiencies were calculated and their dependence on the acceptor concentration was analysed for three excitation wavelengths. It was found that any change in the excitation wavelength leads to significant variations in the quenching characteristics, which in turn affect the calculated energy transfer parameters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Photoluminescence (PL) spectroscopy is an optical technique that has emerged successful in the field of semiconductor material and device characterization. This technique is quite a powerful one which gives idea about the defect levels in a material, the band gap of the material, composition as well as material quality. Over the recent years it has received an elevation as a mainstream characterization technique. This thesis is an attempt to characterize each individual layer used in a thin film solar cell with special focus on the electrical properties. This will be highly beneficial from the lab as well as industrial point of view because electrical measurements generally are contact mode measurements which tend to damage the surface. As far as a thin film solar cell is concerned, the constituent layers are the transparent conducting oxide (TCO), absorber layer, buffer layer and top electrode contact. Each layer has a specific role to play and the performance of a solar cell is decided and limited by the quality of each individual layer. Various aspects of PL spectroscopy have been employed for studying compound semiconductor thin films [deposited using chemical spray pyrolysis (CSP)] proposed for solar cell application. This thesis has been structured in to seven chapters

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Los solventes orgánicos son sustancias químicas que por sus propiedades físico-químicas son fácilmente inhalados o absorbidos por la piel, pueden causar daños de diversa índole en la salud. En Colombia existen normas que contemplan las medidas de protección, sin embargo persiste la informalidad en el sector de pintores de autos, por lo cual los trabajadores expuestos, a largo plazo pueden ver afectada su salud. En este estudio se analizó la relación entre individuos expuestos laboralmente a los solventes orgánicos versus no expuestos con respecto a la longitud de sus telómeros y formación de fragilidades. Se emplearon muestras de sangre extraídas por venopunción, recolectada en dos tubos: uno con Heparina, destinado al cultivo de linfocitos, para obtener cromosomas metafásicos y evaluar en ellos la presencia de fragilidades; el otro tubo con EDTA, fue empleado para la extracción de ADN y se utilizó para obtener los valores de longitud telomérica mediante la técnica de PCR cuantitativa. Los análisis estadísticos se realizaron aplicando la prueba de rangos de Wilcoxon, en el caso de la presencia de fragilidades se analizó la razón No.Fragilidades/No.Metafases, aplicando el método de Wilcoxon se encontró que existe diferencia estadísticamente significativa entre expuestos y no expuestos (p = 0,036), en donde los expuestos presentan mayor frecuencia de fragilidades. Por otra parte el valor relativo de longitud telomérica del grupo de expuestos fue mayor que el observado en el grupo de no expuestos, esta diferencia fue estadísticamente significativa (Wilcoxon, p = 0.002).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coatings and filters for spaceflight far-infrared components require a robust, non-absorptive low-index thin film material to contrast with the typically higher refractive index infrared materials. Barium fluoride is one such material for the 10 to 20µm wavelength infrared region, however its optical and mechanical properties vary depending on the process used to deposit it in thin film form. Thin films of dielectric produced by thermal evaporation are well documented as having a lower packing density and refractive index than bulk material. The porous and columnar micro structure of these films causes possible deterioration of their performance in varied environmental conditions, primarily because of the moisture absorption. Dielectric thin films produced by the more novel technique of ion-beam sputtering are denser with no columnar micro structure and have a packing density and refractive index similar to the bulk material. A comparative study of Barium Fluoride (BaF2) thin films made by conventional thermal evaporation and ion-beam sputtering is reported. Films of similar thicknesses are deposited on Cadmium Telluride and Germanium substrates. The optical and mechanical properties of these films are then examined. The refractive index n of the films is obtained from applying the modified Manifacier's evvelope method to the spectral measurements made on a Perkin Elmer 580 spectrophotometer. An estimate is also made of the value of the extinction coefficient k in the infrared wavelength transparent region of the thin film. In order to study the mechanical properties of the BaF2 films, and evaluate their usefulness in spaceflight infrared filters and coatings, the thin film samples are subjected to MIL-F-48616 environmental tests. Comparisons are made of their performance under these tests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With continually increasing demands for improvements to atmospheric and planetary remote-sensing instrumentation, for both high optical system performance and extended operational lifetimes, an investigation to access the effects of prolonged exposure of the space environment to a series of infrared interference filters and optical materials was promoted on the NASA LDEF mission. The NASA Long Duration Exposure Facility (LDEF) was launchd by the Space Shuttle to transport various science and technology experiments both to and from space, providing investigators with the opportunity to study the effects of the space environment on materials and systems used in space-flight applications. Preliminary results to be discussed consist of transmission measurements obtained and processed from an infrared spectrophotometer both before (1983) and after (1990) exposure compared with unexposed control specimens, together with results of detailed microscopic and general visual examinations performed on the experiment. The principle lead telluride (PbTe) and Zinc Sulphide (ZnS) based multilayer filters selected for this preliminary investigation consist of : an 8-12µm low pass edge filter, a 10.6µm 2.5% half bandwidth (HBW) double half-wave narrow bandpass filter, and a 10% HBW triple half-wave wide bandpass filter at 15µm. Optical substrates of MgF2 and KRS-5 (T1BrI) will also be discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sixteen years (1994 – 2009) of ozone profiling by ozonesondes at Valentia Meteorological and Geophysical Observatory, Ireland (51.94° N, 10.23° W) along with a co-located MkIV Brewer spectrophotometer for the period 1993–2009 are analyzed. Simple and multiple linear regression methods are used to infer the recent trend, if any, in stratospheric column ozone over the station. The decadal trend from 1994 to 2010 is also calculated from the monthly mean data of Brewer and column ozone data derived from satellite observations. Both of these show a 1.5 % increase per decade during this period with an uncertainty of about ±0.25 %. Monthly mean data for March show a much stronger trend of ~ 4.8 % increase per decade for both ozonesonde and Brewer data. The ozone profile is divided between three vertical slots of 0–15 km, 15–26 km, and 26 km to the top of the atmosphere and a 11-year running average is calculated. Ozone values for the month of March only are observed to increase at each level with a maximum change of +9.2 ± 3.2 % per decade (between years 1994 and 2009) being observed in the vertical region from 15 to 26 km. In the tropospheric region from 0 to 15 km, the trend is positive but with a poor statistical significance. However, for the top level of above 26 km the trend is significantly positive at about 4 % per decade. The March integrated ozonesonde column ozone during this period is found to increase at a rate of ~6.6 % per decade compared with the Brewer and satellite positive trends of ~5 % per decade.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated chronic incorporation of metals in individuals from poor families, living in a small, restrict and allegedly contaminated area in Sao Paulo city, the surroundings of the Guarapiranga dam, responsible for water supply to 25% of the city population. A total of 59 teeth from individuals 7 to 60 years old were collected. The average concentrations of Pb, Cd, Fe, Zn, Mn, Ni and Cr were determined with an Atomic Absorption Spectrophotometer. The concentrations of all metals as function of the individuals` age exhibited a remarkable similarity: peaks between 7 and 10 years and sharply decreasing at higher ages, which could be attributed to alimentary habits and persistence to metals exposure all along the individuals` life span. From all the measured metals, lead and cadmium were a matter of much more concern since their measured values are close to the upper limits of the world wide averages. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the effects of low-dose therapeutic ionizing radiation on different aesthetic dental materials. Forty five specimens (n = 45) of three different aesthetic restorative materials were prepared and randomly divided into five groups: G1 (control group); G2, G3, G4, G5 experimental groups irradiated respectively with 0.25, 0.50, 0.75, and 1.00 Gy of gamma radiation by the (60)Co teletherapy machine. Chemical analyses were performed using a FT-IR Nicolet 520 spectrophotometer with reflectance diffuse technique. Even a minimal exposition at ionizing radiation in therapeutic doses can provide chemical changes on light-cured composite resins. The three studied restorative materials showed changes after exposure at gamma radiation, however the increase of the radiation dose did not contribute to an increase in this effect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optimization of photo-Fenton degradation of copper phthalocyanine blue was achieved by response surface methodology (RSM) constructed with the aid of a sequential injection analysis (SIA) system coupled to a homemade photo-reactor. Highest degradation percentage was obtained at the following conditions [H(2)O(2)]/[phthalocyanine] = 7, [H(2)O(2)]/[FeSO(4)] = 10, pH = 2.5, and stopped flow time in the photo reactor = 30 s. The SIA system was designed to prepare a monosegment containing the reagents and sample, to pump it toward the photo-reactor for the specified time and send the products to a flow-through spectrophotometer for monitoring the color reduction of the dye. Changes in parameters such as reagent molar ratios. residence time and pH were made by modifications in the software commanding the SI system, without the need for physical reconfiguration of reagents around the selection valve. The proposed procedure and system fed the statistical program with degradation data for fast construction of response surface plots. After optimization, 97% of the dye was degraded. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The interaction of 4-nerolidylcatechol (4-NRC), a potent antioxidant agent, and 2-hydroxypropyl-beta-cyclodextrin (HP-beta-CD) was investigated by the solubility method using Fourier transform infrared (FTIR) methods in addition to UV-Vis, (1)H-nuclear magnetic resonance (NMR) spectroscopy and molecular modeling. The inclusion complexes were prepared using grinding, kneading and freeze-drying methods. According to phase solubility studies in water a B(S)-type diagram was found, displaying a stoichiometry complexation of 2:1 (drug:host) and stability constant of 6494 +/- A 837 M(-1). Stoichiometry was established by the UV spectrophotometer using Job`s plot method and, also confirmed by molecular modeling. Data from (1)H-NMR, and FTIR, experiments also provided formation evidence of an inclusion complex between 4-NRC and HP-beta-CD. 4-NRC complexation indeed led to higher drug solubility and stability which could probably be useful to improve its biological properties and make it available to oral administration and topical formulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents the use of sequential injection analysis (SIA) and the response surface methodology as a tool for optimization of Fenton-based processes. Alizarin red S dye (C.I. 58005) was used as a model compound for the anthraquinones family. whose pigments have a large use in coatings industry. The following factors were considered: [H(2)O(2)]:[Alizarin] and [H(2)O(2)]:[FeSO(4)] ratios and pH. The SIA system was designed to add reagents to the reactor and to perform on-line sampling of the reaction medium, sending the samples to a flow-through spectrophotometer for monitoring the color reduction of the dye. The proposed system fed the statistical program with degradation data for fast construction of response surface plots. After optimization, 99.7% of the dye was degraded and the TOC content was reduced to 35% of the original value. Low reagents consumption and high sampling throughput were the remarkable features of the SIA system. (C) 2008 Published by Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the many existing crosslinking procedures, glutaraldehyde (GA) is still the method of choice used in the manufacture of bioprosthesis. The major problems with GA are: (a) uncontrolled reactivity due to the chemical complexity or GA solutions; (b) toxicity due to the release of GA from polymeric crosslinks; and (c) tissue impermeabilization due to polymeric and heterogeneous crosslinks formation, partially responsible for the undesirable calcification of the bioprosthesis. A new method of crosslinking glutaraldehyde acetals has been developed with GA in acid ethanolic solution, and after the distribution inside de matrix, GA is released to crosslinking. Concentrations of hydrochloride acid in ethanolic solutions between 0.1 and 0.001 mol/L with GA concentration between 0.1 and 1.0% were measured in an ultraviolet spectrophotometer to verify the presence of free aldehyde groups and polymeric compounds of GA. After these measurements, the solutions were used to crosslink bovine pericardium. The spectrophotometric results showed that GA was better protected in acetal forms for acid ethanolic solution with HCl at 0.003 mol/L and GA 1.0%(v/v). The shrinkage temperature results of bovine pericardium crosslinked with acetal solutions showed values near 85 C after the exposure to triethylamine vapors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This degree theme work aims to evaluate the present ICC-profile and printing ink of Dalarnas Tidningar AB. The companyhas changed printing ink quality and wants to evaluate how the present ICC-profile work with the new printingink. Four different ICC-profiles were included in the comparison.One test printing was accomplished with two different separations. Two new ICC-profile was created, as a comparingmaterial. An densitometer was used to measure the technical parameters of the printing. IT8-charts and RGB-chartswas measured with spectrophotometer. La*b*-values, CMYK-values, graybalance curves, color deflections and colorgamuts was compared on screen and on the printed material.Materials from an earlier testprinting and evalution, made by Stora Enso Kvarnsveden AB 2003, was used to evaluatethe function of Dalarnas Tidningar AB´s ICC-profile with the present printing ink quality. The IT8-chart from todaystestprinting was oppened in a program for textediting to have access to La*b*- and CMYK values. The values from theearlier testprinting was supplied from Stora Enso Kvarnsveden AB.The result of this work shows that the ICC-profile from the company, compared with de other profiles, reproduce darkershadow regions which can make loss of details. An higher saturation is recieved in the red and yellow area while thegreen and blue area lose its intensity. The profile gave images which are some contrastless and with a flat reproduction.Today printing ink quality gives more saturation and intensity in the yellow and blue area compared with former printingink. The dark tone reproduces with decreased luminance, however.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When using the digital halftone proofing systems, a closer print match can be achieved compared to what earlier couldbe done with the analogue proofing systems. These proofing systems possibilities to produce accurate print match canas well lead to producing bad print matches as several print related parameters can be adjusted manually in the systemby the user. Therefore, more advanced knowledge in graphic arts technology is required by the user of the system.The prepress company Colorcraft AB wishes to control that their color proofs always have the right quality. This projectwas started with the purpose to find a quality control metod for Colorcraft´s digital halftone proofing system(Kodak Approval XP4).Using a software who supports spectral measuring combined with a spectrophotometer and a control bar, a qualitycontrol system was assembled. This system detects variations that lies out of the proofing system´s natural deviation.The prerequisite for this quality control system is that the tolerances are defined with consideration taken to the proofingsystems natural deviations. Othervise the quality control system will generate unnecessecary false alarms and thereforenot be reliable.