970 resultados para Soil-pile Interaction


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de mestre em Engenharia Civil

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A cylinder experiment was conducted in northern Greece during 2005 and 2006 to assess emergence dynamics of barnyardgrass (Echinochloa crus-galli (L.) Beauv.) and jimsonweed (Datura stramonium L.) in the case of a switch from conventional to conservation tillage systems (CT). Emergence was surveyed from two burial depths (5 and 10 cm) and with simulation of reduced tillage (i.e. by soil disturbance) and no-till conditions. Barnyardgrass emergence was significantly affected by burial depth, having greater emergence from 5 cm depth (96%) although even 78% of seedlings emerged from 10 cm depth after the two years of study. Emergence of barnyardgrass was stable across years from the different depths and tillage regimes. Jimsonweed seeds showed lower germination than barnyardgrass during the study period, whereas its emergence was significantly affected by soil disturbance having 41% compared to 28% without disturbance. A burial depth x soil disturbance interaction was also determined, which showed higher emergence from 10 cm depth with soil disturbance. Jimsonweed was found to have significantly higher emergence from 10 cm depth with soil disturbance in Year 2. Seasonal emergence timing of barnyardgrass did not vary between the different burial depth and soil disturbance regimes, as it started in April and lasted until end of May in both years. Jimsonweed showed a bimodal pattern, with first emergence starting end of April until mid-May and the second ranging from mid-June to mid-August from 10 cm burial depth and from mid-July to mid-August from 5 cm depth, irrespective of soil disturbance in both cases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

While the simulation of flood risks originating from the overtopping of river banks is well covered within continuously evaluated programs to improve flood protection measures, flash flooding is not. Flash floods are triggered by short, local thunderstorm cells with high precipitation intensities. Small catchments have short response times and flow paths and convective thunder cells may result in potential flooding of endangered settlements. Assessing local flooding and pathways of flood requires a detailed hydraulic simulation of the surface runoff. Hydrological models usually do not incorporate surface runoff at this detailedness but rather empirical equations are applied for runoff detention. In return 2D hydrodynamic models usually do not allow distributed rainfall as input nor are any types of soil/surface interaction implemented as in hydrological models. Considering several cases of local flash flooding during the last years the issue emerged for practical reasons but as well as research topics to closing the model gap between distributed rainfall and distributed runoff formation. Therefore, a 2D hydrodynamic model, depth-averaged flow equations using the finite volume discretization, was extended to accept direct rainfall enabling to simulate the associated runoff formation. The model itself is used as numerical engine, rainfall is introduced via the modification of waterlevels at fixed time intervals. The paper not only deals with the general application of the software, but intends to test the numerical stability and reliability of simulation results. The performed tests are made using different artificial as well as measured rainfall series as input. Key parameters of the simulation such as losses, roughness or time intervals for water level manipulations are tested regarding their impact on the stability.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An experimental study has been conducted to investigate the behavior of continuous flight auger (cfa) bored piles and metalic driven H-section piles under lateral loading in cohesionless soils. The piles were tested in two different areas at the same site. Both areas consisted of a 3-m thick compacted superficial fill of pure fine sand, underlain by layers of naturally occurring pure fine-thick sand. Fills are differentiated by the relative densities which were compressed, 45% e 70%, respectively. Each area received one identical pair of cfa piles and two identical pairs of H-piles. A static lateral loading test was performed in each pair of piles. In this work, the pile load test results are reported and interpreted. The horizontal coefficient of subgrade reaction was determined from the results of the loading tests and compared with values determined by correlations based on penetration resistance index of SPT tests (NSPT). p-y formulations describing the static behavior of the piles were applied to the problem under evaluation. Back Analyses were made through theoretical and experimental p-y curves for obtaining input parameters for the analytic models, among which the coefficient of horizontal reaction. The soil pile system horizontal loading at rupture was determined by the theoretical methods and the results were compared with the experimental results, checking its validity

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The study that resulted in this dissertation was developed at OU RNCE PETROBRAS, in Natal, which implemented a project of rational use and reuse of water, including use of wastewater from a Sewage Treatment Plant (STP) already in place, diluted with water from own wells for irrigation of green area of the building complex corporate enterprise. Establish a methodology that can serve as guidelines for future projects controlled reuse of water like this was the objective of this research. Been proposed, implemented and evaluated three instruments of sanitary and environmental control: 1) adaptation of sewage treatment plant and quality control of the treated effluent 2) analysis of soil-nutrient interaction in the irrigated area, 3) knowledge of the local hydrogeology, especially with regard to the direction of flow of the aquifer and location of collection wells of Companhia de Águas e Esgotos do Rio Grande do Norte (CAERN) situated in the surroundings. These instruments have proven sufficient and appropriate to ensure the levels of sanitary and environmental control proposed and studied, which were: a) control of water quality off the STP and the output of the irrigation reservoir, b) control of water quality sub surface soil and assessment of progress on soil composition, c) assessment of water quality in the aquifer. For this, we must: 1) establishing the monitoring plan of the STP and its effluent quality sampling points and defining the parameters of analysis, improve the functioning of that identifying the adequacy of flow and screening as the main factors of operational control, and increase the efficiency of the station to a relatively low cost, using additional filters, 2) propose, implement and adapt simple collectors to assess the quality of water percolating into the soil of the irrigated area, 3) determine the direction of groundwater flow in the area study and select the wells for monitoring of the aquifer.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents and discusses Ménard Pressuremeter test results used to predict bearing capacity of pounded piles installed in a tropical sandy soil. Fifteen pre-bored pressuremeter tests were carried out at the Experimental Research Site from Unesp - Bauru up to 15 m depth, one test per meter. Several laboratory and in situ tests were carried out in this research site as well as load tests on plates and on piles. Pressuremeter test results were firstly analyzed to determine geotechnical soil parameters based on empirical methods, emphasizing the estimative of the earth pressure coefficient at rest (K0). After that, bearing capacity prediction of pounded piles with 4 m, 7 m and 10 m were made and compared with test results from instrumented load tests. Pressuremeter test results allowed a very good estimative of bearing capacity for the pile with 4 m length and underestimated in 25,7% and 20,0% the bearing capacity for the pile with 7 and 10 m length, respectively. The back analysis of the test results suggests that the appropriate value for the bearing capacity factor for the tested soil-pile system on this soil is equal to 2.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this study was to evaluate the behavior of morphological Eucalyptus platyphylla when subjected to five levels of soil salinity. The research project was conducted in a greenhouse at the experimental area of the Department of Agricultural Engineering of the FCA / UNESP, Botucatu-SP, utilizing plastic pots filled with soil containing NaCl concentrations, in sufficient quantities to raise the level of electrical conductivity. The experiment was conducted in randomized blocks in factorial scheme 5 x 4, 5 electrical conductivities (1.41, 2.50, 4.50, 6.45 and 8.33 dS m-1) and four repetitions. The results showed that soil salinity did not significantly affect the following parameters: height, green mass and dry matter of shoot, and root and leaf area of the plants.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The study aimed to assess the moisture and density of the soil, the amount of water stored in the profile, and the average soil's porosity with Eucalyptus grandis reforestation, compared to bare soil. The study areas are located in the Paulista region, in São Paulo, Brazil. The samples were collected in layers of 0, 20, 40, 60, 100 and 300 cm, in the months of April, June, August and October 2008. The results show that the density is lower and the porosity is higher in Eucalyptus forest soil compared to bare soil, due to the higher content of organic matter in forest leaf litter. Furthermore, the forest soil has a lower amount of water stored in profile than the bare soil without vegetation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A major aspect in geosynthetics creep analysis is the load level applied to the specimen, usually referred as a percentage of the geosynthetic ultimate tensile strength (UTS). Since both tensile and creep standard tests are performed with in-isolation specimens, they may not reproduce the possibly significant effect of soil-geosynthetic interaction. A new creep testing machine was recently developed and successfully addressed this concern. However, further developments allowed tensile tests to be performed in the same conditions used in nonconventional creep ones. This paper presents the results of nonconventional tensile tests performed with a woven biaxial polyester geogrid. They were used to define its UTS in the same conditions employed in creep tests performed with the new equipment. Despite changes in tensile curves shapes were found, the UTS from confined, accelerated and confined-accelerated tensile tests were quite similar to those obtained with standard tensile test procedure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents an alternative coupling strategy between the Boundary Element Method (BEM) and the Finite Element Method (FEM) in order to create a computational code for the analysis of geometrical nonlinear 2D frames coupled to layered soils. The soil is modeled via BEM, considering multiple inclusions and internal load lines, through an alternative formulation to eliminate traction variables on subregions interfaces. A total Lagrangean formulation based on positions is adopted for the consideration of the geometric nonlinear behavior of frame structures with exact kinematics. The numerical coupling is performed by an algebraic strategy that extracts and condenses the equivalent soil's stiffness matrix and contact forces to be introduced into the frame structures hessian matrix and internal force vector, respectively. The formulation covers the analysis of shallow foundation structures and piles in any direction. Furthermore, the piles can pass through different layers. Numerical examples are shown in order to illustrate and confirm the accuracy and applicability of the proposed technique.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este estudio aborda la recopilación de nuevas tendencias del diseño sismorresistente, enfocándose en la técnica del aislamiento de base, por ser la más efectiva, difundida y utilizada; y el análisis de las ventajas que puede tener una edificación que aplica dicha técnica, desde el punto de vista estructural y económico. Se elige la tipología más frecuente o común de edificios de hormigón armado propensos a ser aislados, que en este caso es un hospital, cuyo modelo empotrado se somete a varias normas sismorresistentes comparando principalmente fuerzas de cortante basal, y considerando la interacción suelo-estructura; para asistir a este cálculo se desarrolla un programa de elementos viga de 6 gdl por nodo en código Matlab. El modelo aislado incluye el análisis de tres combinaciones de tipos de aisladores HDR, LPR y FPS, alternando modelos lineales simplificados de 1 y 3 gdl por piso, evaluando diferencias de respuestas de la estructura, y procediendo a la elección de la combinación que de resultados más convenientes; para la modelación no lineal de cada sistema de aislamiento se utiliza el método explícito de diferencias centrales. Finalmente, se realiza un análisis comparativo de daños esperados en el caso de la ocurrencia del sismo de diseño, utilizando el método rápido y tomando como referencia el desplazamiento espectral del último piso; llegando a dar conclusiones y recomendaciones para el uso de sistemas de aislamiento. This study addresses the collection of new seismic design trends, focusing on base isolation technique, as the most effective and widely used, and the analysis of the advantages in buildings that apply this technique, from the structurally and economically point of view. Choosing the most common types of concrete buildings likely to be isolated, which in this case is a hospital, the fix model is subjected to various seismic codes mainly comparing base shear forces, and considering the soil-structure interaction; for this calculation attend a program of bars 6 dof per node is made in Matlab code. The isolated model includes analysis of three types of isolators combinations HDR, LPR and FPS, alternating simplified linear model of 1 and 3 dof per floor, evaluating differences in the response of the structure, and proceeding to the choice of the combination of results more convenient; for modeling nonlinear each insulation system, the explicit central difference method is used. Finally, a comparative analysis of expected damage in the case of the design earthquake, using a fast combined method and by reference to the spectral displacement of the top floor; reaching conclusions and give recommendations for the use of insulation systems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A simplified analytical model of a short span bridge is proposed. The inertial interaction effects of pier foundations and abutments has been included in order to evaluate the response sensitivities to different soil-structure interaction variables. The modification of natural frequency and damping properties is shown for typical short span bridges of the integral deck-abutment type for longitudinal vibrations or general bridges for the transverse ones.