306 resultados para Screws


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Receipt from A. Jeffrey of St. Catharines regarding payment for screws and white glue, June 30, 1876.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Receipt from Pratt and Co. of Buffalo, New York, Wholesale Dealers in Hardware for payment on screws, fasteners, locks, keys and other hardware. This document is stained, July 21, 1876.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectif: Nous avons effectué une étude chez 135 patients ayant subis une chirurgie lombo-sacrée avec vissage pédiculaire sous navigation par tomographie axiale. Nous avons évalué la précision des vis pédiculaires et les résultats cliniques. Méthodes: Cette étude comporte 44 hommes et 91 femmes (âge moyen=61, intervalle 24-90 ans). Les diamètres, longueurs et trajectoires des 836 vis ont été planifiés en préopératoire avec un système de navigation (SNN, Surgical Navigation Network, Mississauga). Les patients ont subi une fusion lombaire (55), lombo-sacrée (73) et thoraco-lombo-sacrée (7). La perforation pédiculaire, la longueur des vis et les spondylolisthesis sont évalués par tomographies axiales postopératoires. Le niveau de douleur est mesuré par autoévaluations, échelles visuelles analogues et questionnaires (Oswestry et SF-36). La fusion osseuse a été évaluée par l’examen des radiographies postopératoires. Résultats: Une perforation des pédicules est présente pour 49/836 (5.9%) des vis (2.4% latéral, 1.7% inférieur, 1.1% supérieur, 0.7% médial). Les erreurs ont été mineures (0.1-2mm, 46/49) ou intermédiaires (2.1 - 4mm, 3/49 en latéral). Il y a aucune erreur majeure (≥ 4.1mm). Certaines vis ont été jugées trop longues (66/836, 8%). Le temps moyen pour insérer une vis en navigation a été de 19.1 minutes de l΄application au retrait du cadre de référence. Un an postopératoire on note une amélioration de la douleur des jambes et lombaire de 72% et 48% en moyenne respectivement. L’amélioration reste stable après 2 ans. La dégénérescence radiologique au dessus et sous la fusion a été retrouvée chez 44 patients (33%) and 3 patients respectivement (2%). Elle est survenue en moyenne 22.2 ± 2.6 mois après la chirurgie. Les fusions se terminant à L2 ont été associées à plus de dégénération (14/25, 56%). Conclusion: La navigation spinale basée sur des images tomographiques préopératoires est une technique sécuritaire et précise. Elle donne de bons résultats à court terme justifiant l’investissement de temps chirurgical. La dégénérescence segmentaire peut avoir un impact négatif sur les résultats radiologique et cliniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introducción: El Deslizamiento Epifisiario Capital Femoral es la enfermedad de la cadera más común en adolescentes entre los 9 y 16 años. Es de causa idiopática, más frecuente en hombres, se clasifica en 4 estadios según criterios clínicos y radiológicos. Se buscó evaluar la evolución de los deslizamientos moderados y severos tratados con una de las dos técnicas propuestas. Metodología Se realizó un estudio descriptivo con pacientes que fueron llevados a fijación in situ o luxación controlada entre 2008 y 2011. Resultados: Se incluyeron 26 pacientes, los cuales el 65.4% se les realizó luxación quirúrgica controlada y el 34.6% fijación in situ. El 70,6% de pacientes tenían DECF inestable y 70,5% tenían desplazamiento severo. La evaluación de la escala WOMAC para dolor, rigidez y capacidad funcional encontró mejores beneficios para el grupo de fijación in situ, estadísticamente significativos (p<0,05), no solo en términos de dolor, rigidez y capacidad funcional sino menor frecuencia de complicaciones. Las complicaciones más frecuentes en el grupo de luxación quirúrgica controlada fueron un caso de infección, 7 casos (41,2%) de necrosis avascular de cabeza femoral, 5 casos (29,4%) de condrolisis y 2 casos (11,8%) de pseudoartrosis; En el grupo de fijación in situ, solo 1 (11,1%) presentó Infección del Sitio Operatorio y 1 (11,1%) Condrolisis. Resultados significativos solo para necrosis avascular. Discusión: Los pacientes con deslizamientos moderados y severos manejados con fijación in situ tuvieron una mejor resultado con menor proporción de complicaciones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introducción: Las fracturas intertrocantéricas han llegado a nuestros días con una mayor incidencia dado el envejecimiento de la población, con fracturas más complejas, menos estables y asociadas a osteoporosis, se estima que representan aproximadamente 1,75 millones de años de vida perdidos ajustados a discapacidad es decir 0,1% de la carga de morbilidad a nivel mundial. Existe consenso en el tratamiento quirúrgico de este tipo de fracturas, presentando una incidencia variable de fallos, principalmente cuando son inestables, entre estos el denominado “cuto ut”. La utilización de un método de fijación con placa y tornillo helicoidal (DHHS) aparentemente disminuye la incidencia de dichos fallos con respecto a otras técnicas. Metodología: Por medio de una muestra calculada en 128 de pacientes con fracturas intertrocantéricas operados con DHS y DHHS entre el 2007 y el 2012 en La Clínica San Rafael de la ciudad de Bogotá, Colombia, se realizó un análisis multivariado para determinar si existe o no diferencias significativas en los índices de fallo entre estas dos técnicas. Resultados: Los pacientes incluidos en el estudio 54 (42,1%) fueron hombres y 74 (57,8%) fueron mujeres. 75 fueron operados con DHHS y 53 con DHS; en cuanto a las comorbilidades las principales fueron Hipertensión con 40 pacientes para DHS y 30 para DHHS, para el caso de Diabetes Mellitus fueron 13 y 9 para DHS y DHHS, respectivamente; en cuanto al tipo de fractura más común la principal fue la clasificación Tronzo II con 9 pacientes para DHS y 13 para DHHS. Conclusión. Para el estudios se evidencia que para los 3 desenlaces principales evaluados, 1. El porcentaje de re intervención (p=0,282), 2. La supervivencia en el primer año (p=0,499) y 3. El desempeño funcional con la escala de Oxford (p=0,06); no hubo diferencias estadísticamente significativas entre los grupos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introducción: En la práctica neuroquirurgica el uso de tornillos pediculares torácicos ha venido en aumento en el tratamiento de diferentes patologías de la espinales. Desde la descripción original, se confirma la adecuada canalización del trayecto mediante el uso del palpador, sin embargo la validez y seguridad de dicho instrumento es limitada y existe riesgo de complicaciones complejas. En este estudio se comprueba la seguridad y validez del uso del palpador para diagnosticar la integridad del trayecto pedicular torácico. Metodología: Se canalizaron pedículos torácicos en especímenes cadavéricos los cuales de manera aleatoria se clasificaron como normales (íntegros) o anormales (violados). Posteriormente cuatro cirujanos de columna, con diferentes grados de experticia, evaluaron el trayecto pedicular. Se realizaron estudios de concordancia obteniendo coeficiente Kappa, porcentaje total de precisión, sensibilidad, especificidad, VPP y VPN y el área bajo la curva ROC para determinar la precisión de la prueba. Resultados: La precisión y validez en el diagnostico del trayecto pedicular y localización del sitio de violación tienen relación directa con la experiencia y entrenamiento del cirujano, el evaluador con mayor experiencia obtuvo los mejores resultados. El uso del palpador tiene una buena precisión, área bajo la curva ROC 0.86, para el diagnostico de las lesiones pediculares. Discusión: La evaluación precisa del trayecto pedicular, presencia o ausencia de una violación, es dependiente del grado de experiencia del cirujano, adicionalmente la precisión diagnostica de la violación varía según la localización de esta.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in other implant connection systems. The purpose of this study was to evaluate the effects of mechanical loading and repeated insertion/removal cycles on the torque loss of abutments with internal tapered connections. Sixty-eight conical implants and 68 abutments of two types were used. They were divided into four groups: groups 1 and 3 received solid abutments, and groups 2 and 4 received two-piece abutments. In groups 1 and 2, abutments were simply installed and uninstalled; torque-in and torque-out values were measured. In groups 3 and 4, abutments were installed, mechanically loaded and uninstalled; torque-in and torque-out values were measured. Under mechanical loading, two-piece abutments were frictionally locked into the implant; thus, data of group 4 were catalogued under two subgroups (4a: torque-out value necessary to loosen the fixation screw; 4b: torque-out value necessary to remove the abutment from the implant). Ten insertion/removal cycles were performed for every implant/abutment assembly. Data were analyzed with a mixed linear model (P <= 0.05). Torque loss was higher in groups 4a and 2 (over 30% loss), followed by group 1 (10.5% loss), group 3 (5.4% loss) and group 4b (39% torque gain). All the results were significantly different. As the number of insertion/removal cycles increased, removal torques tended to be lower. It was concluded that mechanical loading increased removal torque of loaded abutments in comparison with unloaded abutments, and removal torque values tended to decrease as the number of insertion/removal cycles increased. To cite this article:Ricciardi Coppede A, de Mattos MdaGC, Rodrigues RCS, Ribeiro RF. Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study.Clin. Oral Impl. Res. 20, 2009; 624-632.doi: 10.1111/j.1600-0501.2008.01690.x.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare the accuracy of fit of three types of implant-supported frameworks cast in Ni-Cr alloy: specifically, a framework cast as one piece compared to frameworks cast separately in sections to the transverse or the diagonal axis, and later laser welded. Materials and Methods: Three sets of similar implant-supported frameworks were constructed. The first group of six 3-unit implant-supported frameworks were cast as one piece, the second group of six were sectioned in the transverse axis of the pontic region prior to casting, and the last group of six were sectioned in the diagonal axis of the pontic region prior to casting. The sectioned frameworks were positioned in the matrix (10 N(.)cm torque) and laser welded. To evaluate passive fit, readings were made with an optical microscope with both screws tightened and with only one-screw tightened. Data were submitted to ANOVA and Tukey-Kramer`s test (p < 0.05). Results: When both screws were tightened, no differences were found between the three groups (p > 0.05). In the single-screw-tightened test, with readings made opposite to the tightened side, the group cast as one piece (57.02 +/- 33.48 mu m) was significantly different (p < 0.05) from the group sectioned diagonally (18.92 +/- 4.75 mu m) but no different (p > 0.05) from the group transversally sectioned (31.42 +/- 20.68 mu m). On the tightened side, no significant differences were found between the groups (p > 0.05). Conclusions: Results of this study showed that casting diagonally sectioned frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves the levels of passivity to the same frameworks when compared to structures cast as one piece.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An inappropriate prosthetic fit could cause stress over the interface implant/bone. The objective of this study was to compare stresses transmitted to implants from frameworks cast using different materials and to investigate a possible correlation between vertical misfits and these stresses. Fifteen one-piece cast frameworks simulating bars for fixed prosthesis in a model with five implants were fabricated and arranged into three different groups according to the material used for casting: CP Ti (commercially pure titanium), Co-Cr (cobalt-chromium) or Ni-Cr-Ti (nickel-chromium-titanium) alloys. Each framework was installed over the metal model with all screws tightened to a 10 N cm torque and then, vertical misfits were measured using an optical microscope. The stresses transmitted to implants were measured using quantitative photoelastic analysis in values of maximum shear stress (T), when each framework was tightened to the photoelastic model to a 10 N cm standardized torque. Stress data were statistically analyzed using one-way ANOVA and Tukey`s test and correlation tests were performed using Pearson`s rank correlation (alpha = 0.05). Mean and standard deviation values of vertical misfit are presented for CP Ti (22.40 +/- 9.05 mu m), Co-Cr (66.41 +/- 35.47 mu m) and Ni-Cr-Ti (32.20 +/- 24.47 mu m). Stresses generated by Co-Cr alloy (tau = 7.70 +/- 2.16 kPa) were significantly higher than those generated by CP Ti (tau = 5.86 +/- 1.55 kPa, p = 0.018) and Ni-Cr-Ti alloy (tau =5.74 +/- 3.05 kPa, p = 0.011), which were similar (p = 0.982). Correlations between vertical misfits and stresses around the implants were not significant as for any evaluated materials. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

P>This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P < 0 center dot 05). With both screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27 center dot 57 +/- 5 center dot 06 mu m) than other groups (I: 11 center dot 19 +/- 2 center dot 54 mu m, III: 12 center dot 88 +/- 2 center dot 93 mu m, IV: 13 center dot 77 +/- 1 center dot 51 mu m) (P < 0 center dot 05). In the single-screw-tightened test, with readings on the opposite side to the tightened side, Ni-Cr cast as one-piece (I: 58 center dot 66 +/- 14 center dot 30 mu m) was significantly different from cp Ti group after diagonal section (IV: 27 center dot 51 +/- 8 center dot 28 mu m) (P < 0 center dot 05). On the tightened side, no significant differences were found between groups (P > 0 center dot 05). Results showed that diagonally sectioning ill-fitting cp Ti frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves passivity levels of the same frameworks when compared to one-piece cast structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of the present study was to investigate the healing, integration, and maintenance of autogenous onlay bone grafts and implant osseointegration either loaded in the early or the delayed stages. Materials and Methods: A total of 5 male clogs received bilateral blocks of onlay bone grafts harvested from the contralateral alveolar ridge of the mandible. On one side, the bone block was secured by 3 dental implants (3.5 mm x 13.0 mm, Osseospeed; Astra Tech AB, Molndal, Sweden). Two implants at the extremities of the graft were loaded 2 clays after installation by abutment connection and prosthesis (simultaneous implant placement group); the implant in the middle remained unloaded and served as the control. On the other side, the block was fixed with 2 fixation screws inserted in the extremities of the graft. Four weeks later, the fixation screws were replaced with 3 dental implants. The loading procedure (delayed implant placement group) was performed 2 clays later, as described for the simultaneous implant placement sites. The animals were sacrificed 12 weeks after the grafting procedure. Implant stability was measured through resonance frequency analysis. The bone volume and density were assessed on computed tomography. The bone to implant contact and bone area in a region of interest were evaluated on histologic slides. Results: The implant stability quotient showed statistical significance in favor of the delayed loaded grafts (P=.001). The bone-to-implant contact (P=.008) and bone area in a region of interest (P=0.005) were significantly greater in the delayed group. Nevertheless, no difference was found in terms of graft volume and density between the early loaded and delayed-loaded approaches. Conclusions: The protocol in which the implant and bone graft were given delayed loading allows for effective quality of implant osseointegration and stabilization, with healing and remodeling occurring in areas near the implant resulting in denser bone architecture. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Sing 68:825-832, 2010

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to compare, by mechanical in vitro testing, a 2.0-mm system made with poly-L-DL-lactide acid with an analogue titanium-based system. Mandible replicas were used as a substrate and uniformly sectioned on the left mandibular angle. The 4-hole plates were adapted and stabilized passively in the same site in both groups using four screws, 6.0 mm long. During the resistance-to-load test, the force was applied perpendicular to the occlusal plane at three different points: first molar at the plated side; first molar at the contralateral side; and between the central incisors. At 1 mm of displacement, no statistically significant difference was found. At 2 mm displacement, a statistically significant difference was observed when an unfavourable fracture was simulated and the load was applied in the contralateral first molar and when a favourable fracture was simulated and the load was applied between the central incisors. At the failure displacement, a statistically significant difference was observed only when the favourable fracture was simulated and the load was applied on the first molar at the plated side. In conclusion, despite more failure, the poly-L-DL-lactic acid-based system was effective.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ton clinically healthy two- to three-month-old poodles weighing 1.5-2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the some longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate the stress distribution in the resin in contact with the spirals of cylindrical and conical mini-implants, when submitted to lateral load and insertion torsion. A photoelastic model was fabricated using transparent gelatin to simulate the alveolar bone. The model was observed with a plane polariscope and photographically recorded before and after activation of the two screws with a lateral force and torsion. The lateral force application caused bending moments on both mini-implants, with the uprising of fringes or isochromatics, characteristics of stresses, along the threads of the mini-implants and in the apex. When the torsion was exerted in the mini-implants, a great concentration of stress upraised close to the apex. The conclusion was that, comparing conical with cylindrical mini-implants under lateral load, the stresses were similar on the traction sides. The differences appear (1) on the apex, where the cylindrical mini-implant showed a greater concentration of stress, and (2) along the spirals, in the compression side, where the conical mini-implant showed a greater concentration of stress. The greater part of the stress produced by both mini-implants, after torsion load in insertion, were concentrated on the apex. With the cylindrical mini-implant, the greater concentration of tension was close to the apex, while with the conical one, the stresses were distributed along a greater amount of apical threads.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The functional results associated with nonoperative treatment of severely impacted valgus fractures of the proximal part of the humerus are poor, and these injuries are difficult to treat with minimally invasive percutaneous fixation techniques. The aim of this study was to review the functional and radiographic results and complications of a new operative technique in a series of twenty-five patients.

Methods: Over a two-year period, we treated twenty-nine patients with a severely impacted valgus fracture of the proximal part of the humerus. Three patients were lost to follow-up and one died, leaving twenty-five patients who were available for the study. In all of the fractures, the head-shaft angle had been tilted into =160° of valgus and the greater tuberosity was displaced by >1 cm. All patients were treated with open reduction of the fracture, and the space created behind the humeral head was filled with Norian Skeletal Repair System (SRS) bone substitute. The fractures were stabilized with either screws or buttress plate fixation. Associated rotator cuff tears were repaired. All patients underwent functional outcome assessment with use of the Constant, DASH (Disabilities of the Arm, Shoulder and Hand), and SF-36 (Short Form-36) scores at one year, and twelve patients were followed for two years.

Results: All fractures united within the first year, all reductions were maintained, and no patient had signs of osteonecrosis of the humeral head on the latest follow-up radiographs. At one year, the median Constant score was 80 points and the median DASH score was 22 points. The functional results continued to be satisfactory in the twelve patients who were followed for two years. The results in our series were better than those achieved in studies of nonoperative treatment of similar fracture configurations. There were six clinically relevant complications, although none required a reoperation and all six patients had a satisfactory short-term functional outcome.

Conclusions: Internal fixation of severely impacted valgus fractures of the proximal part of the humerus, supplemented by Norian SRS bone substitute to fill the proximal humeral metaphyseal defect, produces good early functional and radiographic outcomes. Additional follow-up will be required to assess whether these initially satisfactory outcomes are maintained over the longer term.

Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.