994 resultados para STRESS MYOCARDIAL PERFUSION SCINTIGRAPHY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: We conducted a meta-analysis to evaluate the accuracy of quantitative stress myocardial contrast echocardiography (MCE) in coronary artery disease (CAD). METHODS AND RESULTS: Database search was performed through January 2008. We included studies evaluating accuracy of quantitative stress MCE for detection of CAD compared with coronary angiography or single-photon emission computed tomography (SPECT) and measuring reserve parameters of A, beta, and Abeta. Data from studies were verified and supplemented by the authors of each study. Using random effects meta-analysis, we estimated weighted mean difference (WMD), likelihood ratios (LRs), diagnostic odds ratios (DORs), and summary area under curve (AUC), all with 95% confidence interval (CI). Of 1443 studies, 13 including 627 patients (age range, 38-75 years) and comparing MCE with angiography (n = 10), SPECT (n = 1), or both (n = 2) were eligible. WMD (95% CI) were significantly less in CAD group than no-CAD group: 0.12 (0.06-0.18) (P < 0.001), 1.38 (1.28-1.52) (P < 0.001), and 1.47 (1.18-1.76) (P < 0.001) for A, beta, and Abeta reserves, respectively. Pooled LRs for positive test were 1.33 (1.13-1.57), 3.76 (2.43-5.80), and 3.64 (2.87-4.78) and LRs for negative test were 0.68 (0.55-0.83), 0.30 (0.24-0.38), and 0.27 (0.22-0.34) for A, beta, and Abeta reserves, respectively. Pooled DORs were 2.09 (1.42-3.07), 15.11 (7.90-28.91), and 14.73 (9.61-22.57) and AUCs were 0.637 (0.594-0.677), 0.851 (0.828-0.872), and 0.859 (0.842-0.750) for A, beta, and Abeta reserves, respectively. CONCLUSION: Evidence supports the use of quantitative MCE as a non-invasive test for detection of CAD. Standardizing MCE quantification analysis and adherence to reporting standards for diagnostic tests could enhance the quality of evidence in this field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Stress myocardial contrast echo (MCE) is technically challenging with exercise (Ex) because of cardiacmovementandshort duration ofhyperemia.Vasodilators solve these limitations, but are less potent for inducing abnormal wall motion (WM). We sought whether a combined dipyridamole (DI; 0.56 mg/kg i.v. 4 min) and Ex stress protocol would enable MCE to provide incremental benefit toWManalysis for detection of CAD. Methods. Standard echo images were followed by real time MCE at rest and following stress in 85 pts, 70 undergoing quantitative coronary angiography and 15 low risk pts.WMAfrom standard and LVopacification images, and then myocardial perfusion were assessed sequentially in a blinded fashion. A subgroup of 13 pts also underwent Ex alone, to assess the contribution of DI to quantitative myocardial flow reserve (MFR). Results. Significant (>50%) stenoses were present in 43 pts, involving 69 territories. Addition of MCE improved SE sensitivity for detection of CAD (91% versus 74%, P = 0.02) and better appreciation of disease extent (87% versus 65%territories, P=0.003), with a non-significant reduction in specificity. In 55 territories subtended by a significant stenosis, but with no resting WM abnormality, ability to identify ischemia was also significantly increased by MCE (82% versus 60%, P = 0.002). MFR was less with Ex alone than with DIEx stress (2.4 ± 1.6 versus 4.0 ± 1.9, P = 0.05), suggesting prolongation of hyperaemia with DI may be essential to the results. Conclusions. Dipyridamole-exercise MCE adds significant incremental benefit to standard SE, with improved diagnostic sensitivity and more accurate estimation of extent of CAD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background We validated a strategy for diagnosis of coronary artery disease ( CAD) and prediction of cardiac events in high-risk renal transplant candidates ( at least one of the following: age >= 50 years, diabetes, cardiovascular disease). Methods A diagnosis and risk assessment strategy was used in 228 renal transplant candidates to validate an algorithm. Patients underwent dipyridamole myocardial stress testing and coronary angiography and were followed up until death, renal transplantation, or cardiac events. Results The prevalence of CAD was 47%. Stress testing did not detect significant CAD in 1/3 of patients. The sensitivity, specificity, and positive and negative predictive values of the stress test for detecting CAD were 70, 74, 69, and 71%, respectively. CAD, defined by angiography, was associated with increased probability of cardiac events [log-rank: 0.001; hazard ratio: 1.90, 95% confidence interval (CI): 1.29-2.92]. Diabetes (P=0.03; hazard ratio: 1.58, 95% CI: 1.06-2.45) and angiographically defined CAD (P=0.03; hazard ratio: 1.69, 95% CI: 1.08-2.78) were the independent predictors of events. Conclusion The results validate our observations in a smaller number of high-risk transplant candidates and indicate that stress testing is not appropriate for the diagnosis of CAD or prediction of cardiac events in this group of patients. Coronary angiography was correlated with events but, because less than 50% of patients had significant disease, it seems premature to recommend the test to all high-risk renal transplant candidates. The results suggest that angiography is necessary in many high-risk renal transplant candidates and that better noninvasive methods are still lacking to identify with precision patients who will benefit from invasive procedures. Coron Artery Dis 21: 164-167 (C) 2010 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introdução – A cintigrafia de perfusão do miocárdio (CPM) é um dos exames complementares de diagnóstico mais indicados na patologia cardiovascular. A atividade extramiocárdica é um problema recorrente na aquisição e avaliação da imagem. Parâmetros como o radiofármaco (RF) administrado, o tipo de esforço, a ingestão de alimentos, o posicionamento e o processamento de imagem influenciam a atividade extramiocárdica na CPM. O objetivo deste estudo é identificar o protocolo da CPM a nível nacional e avaliar a percentagem de repetições das aquisições provocadas por este problema. Metodologia – Para a realização deste estudo, a população selecionada foram os Serviços de Medicina Nuclear (SMN) em Portugal Continental. Foram analisados 15 questionários, respondidos pelos Técnicos Coordenadores dos vários SMN. Foi realizada a associação do comportamento das variáveis, através da estatística descritiva e do Coeficiente de Correlação de Spearman. Resultados – A percentagem de repetições é menor com o uso da 99mTecnécio(Tc)-Tetrofosmina, aquisição de imagens tardias, ingestão de diversos alimentos (água, leite, sumo, pão com manteiga) e com a correção de atenuação. Conclusão – Os resultados obtidos demonstram que a maioria das soluções aplicadas nos SMN resultam numa diminuição das repetições.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear - Ramo de especialização: Radiofarmácia

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The acquisition of a Myocardial Perfusion image (MPI) is of great importance for the diagnosis of the coronary artery disease, since it allows to evaluate which areas of the heart aren’t being properly perfused, in rest and stress situations. This exam is greatly influenced by photon attenuation which creates image artifacts and affects quantification. The acquisition of a Computerized Tomography (CT) image makes it possible to get an atomic images which can be used to perform high-quality attenuation corrections of the radiopharmaceutical distribution, in the MPI image. Studies show that by using hybrid imaging to perform diagnosis of the coronary artery disease, there is an increase on the specificity when evaluating the perfusion of the right coronary artery (RCA). Using an iterative algorithm with a resolution recovery software for the reconstruction, which balances the image quality, the administered activity and the scanning time, we aim to evaluate the influence of attenuation correction on the MPI image and the outcome in perfusion quantification and imaging quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess the frequency and severity of the anomalous origin of the left coronary artery (ALCA) from the pulmonary artery (PA). DESIGN OF THE STUDY: Prospective study of case series between March 1991 and December 1994. SETTING: Referral-based Paediatric Cardiology Department of a Tertiary Care Center. PATIENTS AND METHODS: Five consecutive patients (pts) with anomalous origin of the LCA from the PA; there were three infants aged 4 months and two children one 8 year and one 9 year old. There were three girls and two boys. All pts had clinical and 2D-echo and Doppler investigation prior to cardiac catheterization (CC). Indication for CC was based in the association of symptoms and signs of myocarditis or dilated cardiomyopathy of acute or subacute onset and electrocardiographic (ECG) signs of ischemia in infants. In older patients (pts) diagnosis was suspected mainly from ECG. During CC in all pts, aortograms and when necessary selective coronary angiograms were performed. Surgical correction was performed in all children. In two pts stress exercise ECG and stress Thallium studies before and after surgery were performed. RESULTS: two pts had "adult" an three had "infantile" type of ALCA from the PA. CC was performed and diagnosis was confirmed at surgery in all cases. In one child, correct diagnosis was made by ECO prior to CC and in one case LCA to PA fistula was suspected on Colour-Doppler study. No complications were attributed to CC. Several types of surgery were performed: reimplantation of the ALCA from the PA to the aorta (three pts); tunnel connection of the aorta to the ALCA via the PA (one pt) and left internal mammary to LCA anastomosis (one pt). Two infants died intraoperatively due to extensive myocardial infarction and poor left ventricular function. All the three survivors are asymptomatic after a mean follow up of 34 months. Two oldest pts are currently in New York Heart Association functional class I with normal ECG and improved myocardial perfusion on Thallium scan despite almost total occlusion of LCA at the site of implantation in the aorta as diagnosed on coronary angiogram. CONCLUSIONS: ALCA from PA is associated with major morbidity and mortality. Diagnosis should be suspected in pts with unexplained myocardial ischemia on ECG and even more if it is associated to clinical signs of dilated cardiomyopathy or myocarditis. Careful assessment on ECO and pulsed Doppler and colour flow mapping should make the diagnosis in most cases. Although surgery can be performed based only on ECO diagnosis, we strongly advise for angiography in all cases as in our experience there are false negative diagnosis by ECO. Preoperative Thallium studies can be useful for the selection of the type of surgery as pts with very little viable myocardium will not survive the establishment of a direct systemic to coronary blood flow and may be candidates for heart transplantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMO: Este trabalho tentou contribuir para a caracterização da fisiopatologia da microcirculação coronária em diferentes formas de patologia com o auxílio da ecocardiografia transtorácica. Com a aplicação da ecocardiografia Doppler transtorácica foi efectuado o estudo da reserva coronária da artéria descendente anterior e com a ecocardiografia de contraste do miocárdio foram analisados parâmetros de perfusão do miocárdio como a velocidade da microcirculação coronária, o volume de sangue miocárdico e a reserva de fluxo miocárdico. Estas técnicas foram utilizadas em diferentes situações fisiopatológicas com particular interesse na hipertrofia ventricular esquerda de diferentes etiologias como a hipertensão arterial, estenose aórtica e cardiomiopatia hipertrófica. Também na diabetes mellitus tipo 2 e na doença coronária aterosclerótica, estudámos as alterações da microcirculação coronária. Com a mesma técnica de ecocardiografia de contraste do miocárdio foi analisada a perfusão do miocárdio num modelo experimental animal sujeito a uma dieta aterogénica. Além das conclusões específicas em relação a cada um dos trabalhos efectuados há a referir como conclusões gerais a sua fácil aplicabilidade e exequibilidade em âmbito clínico, a sua reprodutibilidade e precisão. Quando comparadas com técnicas consideradas de referência mostraram resultados com significativa correlação estatística. Em todos os doentes e nos grupos controle foi possível comprovar e quantificar o gradiente de perfusão transmural em repouso e durante a acção de stress vasodilatador, relevando a importância da perfusão sub-endocárdica na função do ventrículo esquerdo. O estudo da microcirculação coronária no grupo de doentes com hipertrofia ventricular esquerda revelou que no grupo com hipertensão arterial existe disfunção da microcirculação coronária ainda antes de se observar aumento de massa do ventrículo esquerdo, e que esta disfunção é diferente em função da geometria ventricular. Nos doentes com estenose aórtica foi demonstrado que além da disfunção da microcirculação coronária, explicada pelo fenómeno de hipertrofia, existe outro componente extrínseco que depois de corrigido através de cirurgia de substituição valvular, conduziu a uma parcial normalização dos valores de reserva coronária. Na cardiomiopatia hipertrófica observou-se uma grande heterogeneidade de perfusão transmural e foi documentado, em imagens de ecocardiografia de contraste do miocárdio e após análise paramétrica, a ausência de perfusão do miocárdio na região sub-endocárdica durante o stress vasodilatador de reserva coronária diminuídos em fases precoces de evolução da doença. Foi demonstrado que a reserva coronária na DM2 em fases mais avançadas estava significativamente diminuída. Descrevemos também em doentes com DM2 e sem doença coronária angiográfica a existência de disfunção da microcirculação coronária. Durante o stress vasodilatador, observámos e documentámos neste grupo de doentes, a existência de defeitos de perfusão transitórios ou de diminuição da velocidade da microcirculação coronária. No grupo de doentes com doença coronária confirmámos o interesse da avaliação da reserva coronária após intervenção percutânea na definição de prognóstico pós EAM, em termos de recuperação funcional do ventrículo esquerdo. Em doentes com BCRE e de difícil estratificação de risco, foi possível calcular o valor de reserva coronária e estratificar o risco de doença coronária. Num modelo experimental animal demonstrámos a exequibilidade da técnica de ECM, e verificámos que nessas condições experimentais, uma sobrecarga aterogénica na dieta, ao fim de 6 semanas, comprometia severamente a reserva coronária. Estes resultados foram parcialmente reversíveis quando à dieta foi adicionada uma estatina. Estas técnicas pela sua não invasibilidade, fácil acesso, repetibilidade e inocuidade perspectivam-se de grande utilidade na caracterização de doentes com disfunção da microcirculação coronária, nas diferentes áreas de diagnóstico, terapêutica e prevenção. A possibilidade de adaptar a técnica em modelos experimentais animais também nos parece poder vir a ter grande utilidade em investigação.----------------ABSTRACT: This work is intended to be a contribution to the study of coronary microcirculation applying new echocardiographic techniques as transthoracic Doppler echocardiography of coronary arteries and myocardial contrast echocardiography. Coronary flow reserve may be assessed by transthoracic Doppler echocardiography, and important functional microcirculation parameters as microcirculation flow velocity, myocardial blood volume and myocardial flow reserve may be evaluated through myocardial contrast echocardiography. Microcirculation was analysed in different pathophysiological settings. We addressed situations with increased left ventricular mass as systemic arterial hypertension, aortic stenosis and hypertrophic cardiomyopathy. Also coronary microcirculation was studied in type 2 Diabetes and in different clinical forms of atherosclerotic coronary artery disease. Specific and detailed conclusions were withdrawn from each experimental work. In the overall it was concluded that these two techniques were important tools to easily assess specific pathophysiological information about coronary microcirculation at bed side which would be difficult to get through other techniques. When compared with gold standard techniques, similar sensibility and specificity was found. Because of their better temporal and spatial resolution it was possible to analyse the importance of transmural perfusion gradients, both in basal and during vasodilatation, and their relation to ischemia, and mechanical wall kinetics, as wall thickening and motion. Coronary microcirculation dysfunction was found in systemic arterial hypertension early evolution stages, also related to different left ventricular geometric patterns. Different etiopathogenical explanations for aortic stenosis coronary microcirculation dysfunction were analysed and compared after aortic valve replacement. Transmural myocardial perfusion heterogeneity pattern was observed in hypertrophic cardiomyopathy which was aggravated during adenosine challenge. Coronary microcirculation dysfunction was diagnosed in type 2 diabetes both with coronary artery disease and with normal angiographic coronary arteries. Dynamic transitory subendocardial perfusion defects with adenosine vasodilatation were visualized in these patients.In patients with left branch block, transthoracic Doppler echocardiography was able to suggest a coronary reserve cut-off value for risk stratification. Also it was possible with this technique to calculate coronary flow reserve and predict restenosis after PTCA Again, in an experimental animal model, applying myocardial contrast echocardiography technique it was possible to study the consequences of an atherogenic diet and statins action on the coronary microcirculation function. Because these techniques are easily performed at bed side, are harmless, use no ionizing radiation and because of their repeatability, reproducibility and accuracythey are promissory tools to assess coronary microcirculation. Both in clinic and research areas these techniques will probably have a role in clinical diagnosis, prevention and therapeutically decision.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract: Scorpion stings are currently the leading cause of venom-related injury to humans in Brazil and are a significant public health problem globally. Only scorpions of the Tityus genus are of medical importance in Brazil, and Tityus serrulatus is responsible for the most serious envenomations and deaths. The toxic effects of scorpion envenomation are due to a massive release of sympathetic and parasympathetic neurotransmitters; the severity is related to cardiac and hemodynamic changes, with cardiogenic shock and pulmonary edema contributing to the main causes of death. The pathophysiology of cardiac involvement has been discussed for decades and has been attributed to adrenergic discharge and a possible toxic effect of venom on the myocardium, while acute pulmonary edema may have a cardiogenic and/or non-cardiogenic origin. Currently, the clinical data point to catecholamine excess as the cause for reversible scorpion cardiomyopathy . These data include electrocardiographic changes, profiling of cardiac enzymes and troponin I, echocardiographic data with global or regional left ventricle dysfunction, and myocardial perfusion alterations compatible with spasm in the coronary microcirculation. Furthermore, recent data on cardiac magnetic resonance imaging findings, which are similar to those observed for stress-induced cardiomyopathy, have also been linked to catecholamine excess. The efficiency of antivenom serum treatment is controversial in the literature. Our experience in Brazil is that the management of patients with systemic manifestations of scorpion stings is based on three approaches, all of which are extremely important. These include symptomatic treatment, antivenom serum, and cardiorespiratory support.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Comparison of doxorubicin uptake, leakage and spatial regional blood flow, and drug distribution was made for antegrade, retrograde, combined antegrade and retrograde isolated lung perfusion, and pulmonary artery infusion by endovascular inflow occlusion (blood flow occlusion), as opposed to intravenous administration in a porcine model. METHODS: White pigs underwent single-pass lung perfusion with doxorubicin (320 mug/mL), labeled 99mTc-microspheres, and Indian ink. Visual assessment of the ink distribution and perfusion scintigraphy of the perfused lung was performed. 99mTc activity and doxorubicin levels were measured by gamma counting and high-performance liquid chromatography on 15 tissue samples from each perfused lung at predetermined localizations. RESULTS: Overall doxorubicin uptake in the perfused lung was significantly higher (P = .001) and the plasma concentration was significantly lower (P < .0001) after all isolated lung perfusion techniques, compared with intravenous administration, without differences between them. Pulmonary artery infusion (blood flow occlusion) showed an equally high doxorubicin uptake in the perfused lung but a higher systemic leakage than surgical isolated lung perfusion (P < .0001). The geometric coefficients of variation of the doxorubicin lung tissue levels were 175%, 279%, 226%, and 151% for antegrade, retrograde, combined antegrade and retrograde isolated lung perfusion, and pulmonary artery infusion by endovascular inflow occlusion (blood flow occlusion), respectively, compared with 51% for intravenous administration (P = .09). 99mTc activity measurements of the samples paralleled the doxorubicin level measurements, indicating a trend to a more heterogeneous spatial regional blood flow and drug distribution after isolated lung perfusion and blood flow occlusion compared with intravenous administration. CONCLUSIONS: Cytostatic lung perfusion results in a high overall doxorubicin uptake, which is, however, heterogeneously distributed within the perfused lung.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND A catheter-based approach after fibrinolysis is recommended if fibrinolysis is likely to be successful in patients with acute ST-elevation myocardial infarction. We designed a 2x2 randomized, open-label, multicenter trial to evaluate the efficacy and safety of the paclitaxel-eluting stent and tirofiban administered after fibrinolysis but before catheterization to optimize the results of this reperfusion strategy. METHODS AND RESULTS We randomly assigned 436 patients with acute ST-elevation myocardial infarction to (1) bare-metal stent without tirofiban, (2) bare-metal stent with tirofiban, (3) paclitaxel-eluting stent without tirofiban, and (4) paclitaxel-eluting stent with tirofiban. All patients were initially treated with tenecteplase and enoxaparin. Tirofiban was started 120 minutes after tenecteplase in those patients randomly assigned to tirofiban. Cardiac catheterization was performed within the first 3 to 12 hours after inclusion, and stenting (randomized paclitaxel or bare stent) was applied to the culprit artery. The primary objectives were the rate of in-segment binary restenosis of paclitaxel-eluting stent compared with that of bare-metal stent and the effect of tirofiban on epicardial and myocardial flow before and after mechanical revascularization. At 12 months, in-segment binary restenosis was similar between paclitaxel-eluting stent and bare-metal stent (10.1% versus 11.3%; relative risk, 1.06; 95% confidence interval, 0.74 to 1.52; P=0.89). However, late lumen loss (0.04+/-0.055 mm versus 0.27+/-0.057 mm, P=0.003) was reduced in the paclitaxel-eluting stent group. No evidence was found of any association between the use of tirofiban and any improvement in the epicardial and myocardial perfusion. Major bleeding was observed in 6.1% of patients receiving tirofiban and in 2.7% of patients not receiving it (relative risk, 2.22; 95% confidence interval, 0.86 to 5.73; P=0.14). CONCLUSIONS This trial does not provide evidence to support the use of tirofiban after fibrinolysis to improve epicardial and myocardial perfusion. Compared with bare-metal stent, paclitaxel-eluting stent significantly reduced late loss but appeared not to reduce in-segment binary restenosis. CLINICAL TRIAL REGISTRATION URL: http://clinicaltrials.gov. Unique identifier: NCT00306228.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Quantification of myocardial blood flow (MBF) with generator-produced (82)Rb is an attractive alternative for centres without an on-site cyclotron. Our aim was to validate (82)Rb-measured MBF in relation to that measured using (15)O-water, as a tracer 100% of which can be extracted from the circulation even at high flow rates, in healthy control subject and patients with mild coronary artery disease (CAD). METHODS: MBF was measured at rest and during adenosine-induced hyperaemia with (82)Rb and (15)O-water PET in 33 participants (22 control subjects, aged 30 ± 13 years; 11 CAD patients without transmural infarction, aged 60 ± 13 years). A one-tissue compartment (82)Rb model with ventricular spillover correction was used. The (82)Rb flow-dependent extraction rate was derived from (15)O-water measurements in a subset of 11 control subjects. Myocardial flow reserve (MFR) was defined as the hyperaemic/rest MBF. Pearson's correlation r, Bland-Altman 95% limits of agreement (LoA), and Lin's concordance correlation ρ (c) (measuring both precision and accuracy) were used. RESULTS: Over the entire MBF range (0.66-4.7 ml/min/g), concordance was excellent for MBF (r = 0.90, [(82)Rb-(15)O-water] mean difference ± SD = 0.04 ± 0.66 ml/min/g, LoA = -1.26 to 1.33 ml/min/g, ρ(c) = 0.88) and MFR (range 1.79-5.81, r = 0.83, mean difference = 0.14 ± 0.58, LoA = -0.99 to 1.28, ρ(c) = 0.82). Hyperaemic MBF was reduced in CAD patients compared with the subset of 11 control subjects (2.53 ± 0.74 vs. 3.62 ± 0.68 ml/min/g, p = 0.002, for (15)O-water; 2.53 ± 1.01 vs. 3.82 ± 1.21 ml/min/g, p = 0.013, for (82)Rb) and this was paralleled by a lower MFR (2.65 ± 0.62 vs. 3.79 ± 0.98, p = 0.004, for (15)O-water; 2.85 ± 0.91 vs. 3.88 ± 0.91, p = 0.012, for (82)Rb). Myocardial perfusion was homogeneous in 1,114 of 1,122 segments (99.3%) and there were no differences in MBF among the coronary artery territories (p > 0.31). CONCLUSION: Quantification of MBF with (82)Rb with a newly derived correction for the nonlinear extraction function was validated against MBF measured using (15)O-water in control subjects and patients with mild CAD, where it was found to be accurate at high flow rates. (82)Rb-derived MBF estimates seem robust for clinical research, advancing a step further towards its implementation in clinical routine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The non-invasive evaluation of myocardial ischemia is a priority in cardiology. The preferred initial non-invasive test is exercise ECG, because of its high accessibility and its low cost. Stress radionuclide myocardial perfusion imaging or stress echocardiography are now routinely performed, and new non-invasive techniques such as perfusion-MRI, dobutamine stress-MRI or 82rubidium perfusion PET have recently gained acceptance in clinical practice. In the same time, an increasing attention has been accorded to the concept of myocardial viability in the decisional processes in case of ischemic heart failure. In this indication, MRI with late enhancement after intravenous injection of gadolinium and 18F-FDG PET showed an excellent diagnostic accuracy. This article will present these new imaging modalities and their accepted indications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: TIDratio indirectly reflects myocardial ischemia and is correlated with cardiacprognosis. We aimed at comparing the influence of three different softwarepackages for the assessment of TID using Rb-82 cardiac PET/CT. Methods: Intotal, data of 30 patients were used based on normal myocardial perfusion(SSS<3 and SRS<3) and stress myocardial blood flow 2mL/min/g)assessed by Rb-82 cardiac PET/CT. After reconstruction using 2D OSEM (2Iterations, 28 subsets), 3-D filtering (Butterworth, order=10, ωc=0.5), data were automatically processed, and then manually processed fordefining identical basal and apical limits on both stress and rest images.TIDratio were determined with Myometrix®, ECToolbox® and QGS®software packages. Comparisons used ANOVA, Student t-tests and Lin concordancetest (ρc). Results: All of the 90 processings were successfullyperformed. TID ratio were not statistically different between software packageswhen data were processed automatically (P=0.2) or manually (P=0.17). There was a slight, butsignificant relative overestimation of TID with automatic processing incomparison to manual processing using ECToolbox® (1.07 ± 0.13 vs 1.0± 0.13, P=0.001)and Myometrix® (1.07 ± 0.15 vs 1.01 ± 0.11, P=0.003) but not using QGS®(1.02 ±0.12 vs 1.05 ± 0.11, P=0.16). The best concordance was achieved between ECToolbox®and Myometrix® manual (ρc=0.67) processing.Conclusion: Using automatic or manual mode TID estimation was not significantlyinfluenced by software type. Using Myometrix® or ECToolbox®TID was significantly different between automatic and manual processing, butnot using QGS®. Software package should be account for when definingTID normal reference limits, as well as when used in multicenter studies. QGS®software seemed to be the most operator-independent software package, whileECToolbox® and Myometrix® produced the closest results.