158 resultados para SAMPLERS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estuaries are poles of attraction for human settlement which is a source of pressures to surface water bodies. The implementation of the European Water Framework Directive (WDF, 2000/60/EC) has increased the investigation in order to develop methodologies to assess the Ecological Quality Status (EQS) of aquatic ecosystems. Transitional systems are naturally stressed and characterized by highly dynamic physical, chemical and hydro-morphologic conditions and by species with a higher level of tolerance to change, being more difficult to develop suitable quality indicators for these systems. The general purpose of this study is to test the ability of synthesis descriptors, including primary (S, taxa richness) and derived biological variable (H’, Shannon-Wiener diversity), biotic indices (AMBI and M-AMBI), body size properties (abundance distribution by body size classes, length, weight and length-weight relationships) and non-taxonomic indices (ISS), as well as functional indicators related to the decomposition rates of various experimental substrates, a macrophyte (Phragmites australis) and an alga (Fucus vesiculosus), to evaluate the environmental quality in transitional systems. This study was carried out in one of the most pristine channels of the Ria the Aveiro, Mira Channel, along a full salinity gradient and in a metals and metalloid sediment contamination area, the Estarreja Channel, and two reference channels (Canelas and Salreu). In this study were used different sampling techniques, the leaf-bag technique and a hand-held corer. In Mira Channel, the alga and the macrophyte presented an opposite trend in the decomposition rate along the salinity gradient, with the decomposition rates of the alga always higher than those of the macrophyte. The decomposition rates of the macrophyte and the alga were higher in the mid estuary and in higher salinity areas, respectively, corresponding to the preferencial distribution areas of each species. The macrobenthic fauna associated with the decaying and an artificial substrate (control) showed equally well the benthic succession from the marine to the freshwater areas and, despite the strong differences in the decay rates, no significant differences were found between the benthic communities associated with the alga and the macrophyte. The body size properties of the macrobenthic fauna associated with the P. australis leaf-bag (1mm and 5mm) and corer samples were studied along the full salinity gradient. The dominant species of the sub-set of measured specimens were not the same of the original macrobenthic fauna sampled but, despite that, the sub-set of measured specimens was also able to show the benthic succession from the marine to the freshwater areas. The body size abundance distribution of the benthic macroinvertebrates according to the ISS size classes did not show a particular trend in any sampler along the salinity gradient. Significant differences were found in the length, weight and length-weight relationships of Annelids, , Molluscs and even some species along the salinity gradient. No significant differences were found in the AMBI, M-AMBI and ISS values along the salinity gradient for all the samplers. The EQS of the corer samples obtained using the M-AMBI was lower than that of the leaf-bags. The EQS obtained with the ISS was higher than that obtained with the M-AMBI in the leaf-bags but not in the corer samples. The ecological effects of contaminated sediments associated with the industrial chemical effluents discharged in the Estarreja Channel were studied a decade after ceasing the emissions, using the Sediment Quality Triad approach and two reference channels. The results showed that despite the emissions ceased in 2004, the sediment remains polluted with high levels of metals and metalloid, available to bioaccumulation and with severe consequences at the community level. The sediment contamination problem was also studied using the leaf-bag technique with a macrophyte, an alga and a control substrate. The results showed that the decay rates, the associated macrofauna and the application of the AMBI, M-AMBI and ISS indices to the mesh-bag samples were not able to identify the sediment contamination. Contrarily to the AMBI, the M-AMBI and the ISS showed significant differences between the contaminated and the reference channels for the corer samples. Although such statistical significance, the interest of using these complex biotic indices could be questioned, when much simple ones, like the S and H’ allow to reach the same conclusions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Very few studies on human exposure to allergenic pollen have been conducted using direct methods, with background concentrations measured at city center monitoring stations typically taken as a proxy for exposure despite the inhomogeneous nature of atmospheric pollen concentrations. A 2003 World Health Organization report highlighted the need for an improved understanding of the relation between monitoring station data and actual exposure. Objective To investigate the relation between grass pollen dose and background concentrations measured at a monitoring station, to assess the fidelity of monitoring station data as a qualitative proxy for dose, and to evaluate the ratio of dose rate to background concentration. Methods Grass pollen dose data were collected in Aarhus, Denmark, in an area where grass pollen sources were prevalent, using Nasal Air Samplers. Sample collection lasted for approximately 25 to 30 minutes and was performed at 2-hour intervals from noon to midevening under moderate exercise by 2 individuals. Results A median ratio of dose rate to background concentration of 0.018 was recorded, with higher ratio values frequently occurring at 12 to 2 pm, the time of day when grass species likely to be present in the area are expected to flower. From 4 to 8 pm, dose rate and background concentration data were found to be strongly and significantly correlated (rs = 0.81). Averaged dose rate and background concentration data showed opposing temporal trends. Conclusion Where local emissions are not a factor, background concentration data constitute a good quantitative proxy for inhaled dose. The present ratio of dose rate to background concentration may aid the study of dose–response relations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2015

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intensification of crop production in the mid-hills of Nepal has led to concerns that nitrogen loss by leaching may increase. This study estimated the amount of N leached during two years from rainfed terraces (bari-land) at three locations in Nepal. Maize or upland rice grown in the monsoon season was given either no nutrient inputs or inputs via either nitrogen fertilizer or farmyard manure. Nitrate concentration in soil solution was measured regularly with porous ceramic cup samplers and drainage estimated from a simple soil water balance. Estimated losses of nitrogen by leaching ranged from 0 to 63.5 kg N ha(-1) depending on location and the form of nitrogen applied. Losses from plots receiving no nutrient inputs were generally small (range: 0-35 kg N ha(-1)) and losses from plots where nitrogen was applied as manure (range: 2-41 kg N ha(-1)) were typically half those from plots with nitrogen applied as fertilizer. Losses during the post-monsoon crops of finger millet were small (typically <5% of total loss) although losses from the one site with blackgram were larger (about 13%). The highest concentrations of nitrate in solution were measured early in the season as the monsoon rains began and immediately following fertilizer applications. Leaching losses are likely to be minimised if manure is applied as a basal nutrient dressing followed by fertilizer nitrogen later in the season.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bone meal amendments are being considered as a remediation method for metal-contaminated wastes. In various forms (biogenic, geogenic or synthetic), apatite, the principal mineral constituent of bone, has shown promise as an amendment to remediate metal-contaminated soils via the formation of insoluble phosphates of Pb and possibly other metals. The efficacy of commercially available bovine bone meal in this role was investigated in a field trial at Nenthead, Cumbria with a mine waste derived soil contaminated with Zn, Pb and Cd. Two 5 m(2) plots were set up: the first as a control and the second, a treatment plot where the soil was thoroughly mixed with bone meal to a depth of 50 cm at a soil to amendment ratio of 25:1 by weight. An array of soil solution samplers (Rhizon SMS (TM)) were installed in both plots and the soil pore water was collected and analysed for Ca, Cd, Zn and Pb regularly over a period of 2 a. Concurrently with the field trial, a laboratory trial with 800 mm high and 100 mm wide leaching Columns Was conducted using identical samplers and with soil from the held site. A substantial release of Zn, Pb, Cd and Ca was observed associated with the bone meal treatment. This release was transient in the case of the leaching columns, and showed seasonal variation in the case of the field trial. It is proposed that this effect resulted from metal complexation with organic acids released during breakdown of the bone meal organic fraction and was facilitated by the relatively high soil pH of 7.6-8.0. Even after this transient release effect had subsided or when incinerated bone meal was substituted in order to eliminate the organic fraction, no detectable decrease in dissolved metals was observed and no P was detected in solution, in contrast with an earlier small column laboratory study. It is concluded that due to the relative insolubility of apatite at above-neutral pH, the rate of supply of phosphate to soil solution was insufficient to result in significant precipitation of metal phosphates and that this may limit the effectiveness of the method to more acidic soils. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tracer gas techniques have been the most appropriate experimental method of determining airflows and ventilation rates in houses. However, current trends to reduce greenhouse gas effects have prompted the need for alternative techniques, such as passive sampling. In this research passive sampling techniques have been used to demonstrate the potential to fulfil these requirements by using solutions of volatile organic compounds (VOCs) and solid phase microextraction (SPME) fibres. These passive sampling techniques have been calibrated against tracer gas decay techniques and measurements from a standard orifice plate. Two constant sources of volatile organic compounds were diffused into two sections of a humidity chamber and sampled using SPME fibres. From a total of four SPME fibres (two in each section), reproducible results were obtained. Emission rates and air movement from one section to the other were predicted using developed algorithms. Comparison of the SPME fibre technique with that of the tracer gas technique and measurements from an orifice plate showed similar results with good precision and accuracy. With these fibres, infiltration rates can be measured over grab samples in a time weighted averaged period lasting from 10 minutes up to several days. Key words: passive samplers, solid phase microextraction fibre, tracer gas techniques, airflow, air infiltration, houses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Passive samplers have been predominantly used to monitor environmental conditions in single volumes. However, measurements using a calibrated passive sampler- Solid Phase Microextraction (SPME) fibre, in three houses with cold pitched roof, successfully demonstrated the potential of the SPME fibre as a device for monitoring air movement in two volumes. The roofs monitored were pitched at 15° - 30° with insulation thickness varying between 200-300 mm on the ceiling. For effective analysis, two constant sources of volatile organic compounds were diffused steadily in the house. Emission rates and air movement from the house to the roof was predicted using developed algorithms. The airflow rates which were calibrated against conventional tracer gas techniques were introduced into a HAM software package to predict the effects of air movement on other varying parameters. On average it was shown from the in situ measurements that about 20-30% of air entering the three houses left through gaps and cracks in the ceiling into the roof. Although these field measurements focus on the airflows, it is associated with energy benefits such that; if these flows are reduced then significantly energy losses would also be reduced (as modelled) consequently improving the energy efficiency of the house. Other results illustrated that condensation formation risks were dependent on the airtightness of the building envelopes including configurations of their roof constructions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The evergreen Quercus ilex L. is one of the most common trees in Italian urban environments and is considered effective in the uptake of particulate and gaseous atmospheric pollutants. However, the few available estimates on O3 and NO2 removal by urban Q. ilex originate from model-based studies (which indicate NO2/O3 removal capacity of Q. ilex) and not from direct measurements of air pollutant concentrations. Thus, in the urban area of Siena (central Italy) we began long-term monitoring of O3/NO2 concentrations using passive samplers at a distance of 1, 5, 10 m from a busy road, under the canopies of Q. ilex and in a nearby open-field. Measurements performed in the period June 2011-October 2013 showed always a greater decrease of NO2 concentrations under the Q. ilex canopy than in the open-field transect. Conversely, a decrease of average O3 concentrations under the tree canopy was found only in autumn after the typical Mediterranean post-summer rainfalls. Our results indicate that interactions between O3/NO2 concentrations and trees in Mediterranean urban ecosystems are affected by temporal variations in climatic conditions. We argue therefore that the direct measurement of atmospheric pollutant concentrations should be chosen to describe local changes of aerial pollution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The concentrations of the water-soluble inorganic aerosol species, ammonium (NH4+), nitrate (NO3-), chloride (Cl-), and sulfate (SO42-), were measured from September to November 2002 at a pasture site in the Amazon Basin (Rondnia, Brazil) (LBA-SMOCC). Measurements were conducted using a semi-continuous technique (Wet-annular denuder/Steam-Jet Aerosol Collector: WAD/SJAC) and three integrating filter-based methods, namely (1) a denuder-filter pack (DFP: Teflon and impregnated Whatman filters), (2) a stacked-filter unit (SFU: polycarbonate filters), and (3) a High Volume dichotomous sampler (HiVol: quartz fiber filters). Measurements covered the late dry season (biomass burning), a transition period, and the onset of the wet season (clean conditions). Analyses of the particles collected on filters were performed using ion chromatography (IC) and Particle-Induced X-ray Emission spectrometry (PIXE). Season-dependent discrepancies were observed between the WAD/SJAC system and the filter-based samplers. During the dry season, when PM2.5 (D-p <= 2.5 mu m) concentrations were similar to 100 mu g m(-3), aerosol NH4+ and SO42- measured by the filter-based samplers were on average two times higher than those determined by the WAD/SJAC. Concentrations of aerosol NO3- and Cl- measured with the HiVol during daytime, and with the DFP during day- and nighttime also exceeded those of the WAD/SJAC by a factor of two. In contrast, aerosol NO3- and Cl- measured with the SFU during the dry season were nearly two times lower than those measured by the WAD/SJAC. These differences declined markedly during the transition period and towards the cleaner conditions during the onset of the wet season (PM2.5 similar to 5 mu g m(-3)); when filter-based samplers measured on average 40-90% less than the WAD/SJAC. The differences were not due to consistent systematic biases of the analytical techniques, but were apparently a result of prevailing environmental conditions and different sampling procedures. For the transition period and wet season, the significance of our results is reduced by a low number of data points. We argue that the observed differences are mainly attributable to (a) positive and negative filter sampling artifacts, (b) presence of organic compounds and organosulfates on filter substrates, and (c) a SJAC sampling efficiency of less than 100%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a Bayesian approach for modeling heterogeneous data and estimate multimodal densities using mixtures of Skew Student-t-Normal distributions [Gomez, H.W., Venegas, O., Bolfarine, H., 2007. Skew-symmetric distributions generated by the distribution function of the normal distribution. Environmetrics 18, 395-407]. A stochastic representation that is useful for implementing a MCMC-type algorithm and results about existence of posterior moments are obtained. Marginal likelihood approximations are obtained, in order to compare mixture models with different number of component densities. Data sets concerning the Gross Domestic Product per capita (Human Development Report) and body mass index (National Health and Nutrition Examination Survey), previously studied in the related literature, are analyzed. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estimating the accessible prey fraction for short-billed waders, we used a new sampling device - the sediment- plane( Desholme t al. 1998) - to record prey density of the uppermost benthos communities in softbottom habitats. In contrast to "ordinary"core-samplers, the sediment plane allows a relatively quick sampling of the uppermost layers of the sediment and, thus, it should allow a more reliable estimate of the accessible benthos community especially of vertically mobile prey organisms such as polychaetes. To assess its usefulness, we compared samples collected with the sediment-plane that took only the uppermost 3cm of the sediment with samples taken with a core-sampler. These investigations showed significant differences between the two sampling methods. In comparison with the corresponding layer of the core samples, we found significantly higher numbers and a higher biomass for at least four polychaete species (e.g. Ragworm Nereis diversicolor) in the plane samples.Therefore, we recommend the use of the sediment-plane when studying the accessible fraction for foraging waders especially when studying short-billed species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Results from a direct recharge experiment conducted in the field to investigate DOC and UVA(254) attenuation rates during the direct injection of UF treated wastewater into a artificial coastal sandfill are presented in this paper. Approximately 500 m(3) of ultra-filtered wastewater was injected into the saturated zone, over a period of 9 days. The movement of the plume was tracked over 80 days, during which time samples were obtained from multilevel samplers installed in transects across the drift axis of the plume. An analysis of fluorescein in the samples obtained during the drift of the UF plume showed that DOC and UVA were attenuated beyond rates predicted by conservative mixing, by up to a maximum of 45%. A degradation coefficient of 0.0175 day(-1) was found to be applicable for DOC degradation. After a drift period of 80 days, DOC and UVA reduced to approximately 4.5 mg/l and 0.100 cm(-1), respectively, from initial values of 8.06 mg/l and 0.199 cm(-1).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We discuss the development and performance of a low-power sensor node (hardware, software and algorithms) that autonomously controls the sampling interval of a suite of sensors based on local state estimates and future predictions of water flow. The problem is motivated by the need to accurately reconstruct abrupt state changes in urban watersheds and stormwater systems. Presently, the detection of these events is limited by the temporal resolution of sensor data. It is often infeasible, however, to increase measurement frequency due to energy and sampling constraints. This is particularly true for real-time water quality measurements, where sampling frequency is limited by reagent availability, sensor power consumption, and, in the case of automated samplers, the number of available sample containers. These constraints pose a significant barrier to the ubiquitous and cost effective instrumentation of large hydraulic and hydrologic systems. Each of our sensor nodes is equipped with a low-power microcontroller and a wireless module to take advantage of urban cellular coverage. The node persistently updates a local, embedded model of flow conditions while IP-connectivity permits each node to continually query public weather servers for hourly precipitation forecasts. The sampling frequency is then adjusted to increase the likelihood of capturing abrupt changes in a sensor signal, such as the rise in the hydrograph – an event that is often difficult to capture through traditional sampling techniques. Our architecture forms an embedded processing chain, leveraging local computational resources to assess uncertainty by analyzing data as it is collected. A network is presently being deployed in an urban watershed in Michigan and initial results indicate that the system accurately reconstructs signals of interest while significantly reducing energy consumption and the use of sampling resources. We also expand our analysis by discussing the role of this approach for the efficient real-time measurement of stormwater systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The urban drainage is one of the powers of environmental sanitation and its scope is the quantitative and qualitative aspects. In decision making of managers and the engineering aspects of design are almost always taken into account only the quantitative aspects. However, the waters of the runoff have the highest concentrations of pollutants at the beginning of precipitation. Thus, if the plot pollution removed, the remaining portion can be used for other purposes. This work has aimed to present the variation of water quality of two drainage basins in the city of Natal / RN-Brazil to support the implementation of drainage to consider the qualitative aspect, and identify potential for the use of water. The basins (M and C) are analyzed closed-type, are in the urban area, are predominantly residential occupation and its waters are used for detention ponds and infiltration. The samples were divided into three phases, the first two direct to final points in a basin and the third in traps distributed over the surface drainage. The parameters had been analyzed were pH, conductivity, dissolved oxygen, Color, Turbidity, COD, Ammonia, nitrite, nitrate, total phosphorus, orthophosphate, Sediments solids, total solids, chloride, sulfate, alkalinity, calcium, magnesium, sodium, potassium, Heavy Metals (Chromium, Cadmium, Lead, Zinc and Copper), Eschichia coli and total coliforms. The parameters studied showed high initial pollution load, events and located in different proportions, except nitrite, heavy metals and biological indicators. The size of the surface drainage and topographic its features influence the quality of water. However, the form of sampling is crucial in the qualitative study in the basin. The samplers developed at work, were generated economic and representative results. The urban rainwater presents organic faecal indicators. The runoff of water from both basins shows no risk of salinity and sodicity for use in irrigation, should be noted the content of chloride in the choice of method of irrigation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)