985 resultados para Pulse Oximeter
Resumo:
BACKGROUND: : The systolic augmentation index (sAix), calculated from the central aortic pulse wave (reconstructed from the noninvasive recording of the radial pulse with applanation tonometry), is widely used as a simple index of central arterial stiffness, but has the disadvantage of also being influenced by the timing of the reflected with respect to the forward pressure wave, as shown by its inverse dependence on heart rate (HR). During diastole, the central aortic pulse also contains reflected waves, but their relationship to arterial stiffness and HR has not been studied. METHODS: : In 48 men and 45 women, all healthy, with ages ranging from 19 to 70 years, we measured pulse wave velocity (PWV, patients supine), a standard evaluator of arterial stiffness, and carried out radial applanation tonometry (patients sitting and supine). The impact of reflected waves on the diastolic part of the aortic pressure waveform was quantified in the form of a diastolic augmentation index (dAix). RESULTS: : Across ages, sexes, and body position, there was an inverse relationship between the sAix and the dAix. When PWV and HR were added as covariates to a prediction model including age, sex and body position as main factors, the sAix was directly related to PWV (P < 0.0001) and inversely to HR (P < 0.0001). With the same analysis, the dAix was inversely related to PWV (P < 0.0001) and independent of HR (P = 0.52). CONCLUSION: : The dAix has the same degree of linkage to arterial stiffness as the more conventional sAix, while being immune to the confounding effect of HR. The quantification of diastolic aortic pressure augmentation by reflected waves could be a useful adjunct to pulse wave analysis.
Resumo:
RESUME: L'objectif de cette étude était de déterminer l'impact de la grossesse non compliquée sur l'onde de pouls de la pression aortique centrale. Méthode 66 femmes au total avec une grossesse simple ont été réparties en trois groupes selon le stade de leur gestation: premier trimestre (T1, n=22), deuxième trimestre (T2, n=20) et troisième trimestre (T3, n=24). Le groupe contrôle (C, n=21) était constitué de femmes non enceintes, en bonne santé habituelle, prenant une contraception oestroprogestative. La tonométrie d'aplanation a été utilisée pour l'acquisition des ondes de pouls centrale un appareil disponible dans le commerce (SphygmoCor) permet l'enregistrement de l'onde de pouls périphérique avec un tonomètre d'aplanation de l'artère radiale au niveau du poignet, puis effectue sa transformation en sa forme centrale, grâce à une analyse de Fourrier et une fonction de transfert. L'influence des ondes réfléchies sur l'onde de pouls a été déterminée non seulement pendant la systole (augmentation systolique), comme on procède habituellement dans l'analyse de l'onde de pouls, mais aussi pendant la diastole (augmentation diastolique). Résultats Au cours de la grossesse, les pressions centrales systolique et diastolique sont restées inchangées et comparables aux valeurs mesurées chez les femmes qui ne sont pas enceintes. Dans le groupe contrôle, l'augmentation systolique s'élevait à 8.1±7.5% de la pression de pouls ; il n'y avait pas de différence statistiquement significative avec les valeurs obtenues chez les femmes enceintes, et ce, à n'importe quel stade de la grossesse (T1 : 4.6±11.4%, T2: 5.0±9.3%, T3 : 4.7±8.1%). Par contre, l'amplitude de l'augmentation diastolique diminuait avec la progression de la grossesse (C 6.5±2.4%, T1 : 5.2±3.1%, T2 : 3.8±2.6%; P=0.002 versus C; T3 : 2.3±2.0%; P<0.0001 versus C et P=0.004 versus T 1). Conclusion La grossesse ne modifie pas la forme de l'onde de pouls systolique centrale, ce qui implique de la part du système cardiovasculaire une adaptation fine à la demande croissante de flux sanguin, et ce, à tous les stades de la grossesse. Par contre, l'amplitude de l'onde de réflexion atteignant l'aorte pendant la diastole diminue progressivement au cours de la grossesse. Perspectives De récentes études montrent qu'une valeur anormalement haute de l'augmentation systolique de la pression centrale, comme on peut la déterminer avec la tonométrie d'aplanation, pourrait être un indice de trouble hypertensif de la grossesse débutant. Cette technique simple pourrait être d'autant plus facile à mettre en oeuvre si les valeurs normales pour l'augmentation systolique étaient indépendantes du stade de la grossesse, comme le suggèrent nos résultats, du moins pour les mesures prises en position assise.
Resumo:
Nest plasticity of Cornitermes silvestrii (Isoptera, Termitidae, Syntermitinae) in response to flood pulse in the Pantanal, Mato Grosso, Brazil. The Pantanal is one of the largest wetlands in the world. Since many areas in Pantanal are flooded during part of the year, it is expected that plants and animals would have mechanisms for their survival during the flooded period. This study investigated the existence of differences in nest shape and inquilines of Cornitermes silvestrii in areas influenced by the flood pulse. We measured the volume, height, width, and height/width ratio of 32 nests in flooded areas and 27 in dry areas, and performed an one-way-Anova with the quasi-Poisson distribution to determine if there were differences in the nest measurements between the points. To analyze the relationship of nest inquilines to flood pulse and nest shape, we performed a regression with a Poisson distribution with the inquiline richness and flood pulse, and the above measurements. The nests of C. silvestrii in flooded areas were significantly higher than nests in dry areas, and had a larger height/width ratio. Colonies in periodically flooded areas would probably make a larger effort to extend their nests vertically, to maintain at least some portion of the structure out of the water and prevent the entire colony from being submerged. Neither the size of the nest nor the flood pulses influenced the assemblage of 11 species found in nests of C. silvestrii.
Resumo:
Pulse-wave velocity (PWV) is considered as the gold-standard method to assess arterial stiffness, an independent predictor of cardiovascular morbidity and mortality. Current available devices that measure PWV need to be operated by skilled medical staff, thus, reducing the potential use of PWV in the ambulatory setting. In this paper, we present a new technique allowing continuous, unsupervised measurements of pulse transit times (PTT) in central arteries by means of a chest sensor. This technique relies on measuring the propagation time of pressure pulses from their genesis in the left ventricle to their later arrival at the cutaneous vasculature on the sternum. Combined thoracic impedance cardiography and phonocardiography are used to detect the opening of the aortic valve, from which a pre-ejection period (PEP) value is estimated. Multichannel reflective photoplethysmography at the sternum is used to detect the distal pulse-arrival time (PAT). A PTT value is then calculated as PTT = PAT - PEP. After optimizing the parameters of the chest PTT calculation algorithm on a nine-subject cohort, a prospective validation study involving 31 normo- and hypertensive subjects was performed. 1/chest PTT correlated very well with the COMPLIOR carotid to femoral PWV (r = 0.88, p < 10 (-9)). Finally, an empirical method to map chest PTT values onto chest PWV values is explored.
Resumo:
It is shown that spatially selective inversion and saturation can be achieved by concatenation of RF pulses with lower flip angles. A concatenation rule which enables global doubling of the flip angle of any given excitation pulse applied to initial z magnetization is proposed. In this fashion, the selectivity of the single pulse is preserved, making the high selectivity achievable in the low flip-angle regime available for inversion and large flip-angle saturation purposes. The profile quality achievable with exemplary concatenated pulses is investigated in comparison with adiabatic inversion. It is verified that by using concatenated inversion in the transfer insensitive labeling technique (TILT), the MT artifact is suppressed. Copyright 2000 Academic Press.
Resumo:
Introduction: Carbon monoxide (CO) poisoning is one of the mostcommon causes of fatal poisoning. Symptoms of CO poisoning arenonspecific and the documentation of elevated carboxyhemoglobin(HbCO) levels in arterial blood sample is the only standard ofconfirming suspected exposure. The treatment of CO poisoning requiresnormobaric or hyperbaric oxygen therapy, according to the symptomsand HbCO levels. A new device, the Rad-57 pulse CO-oximeter allowsnoninvasive transcutaneous measurement of blood carboxyhemoglobinlevel (SpCO) by measurement of light wavelength absorptions.Methods: Prospective cohort study with a sample of patients, admittedbetween October 2008 - March 2009 and October 2009 - March 2010,in the emergency services (ES) of a Swiss regional hospital and aSwiss university hospital (Burn Center). In case of suspected COpoisoning, three successive noninvasive measurements wereperformed, simultaneously with one arterial blood HbCO test. A controlgroup includes patients admitted in the ES for other complaints (cardiacinsufficiency, respiratory distress, acute renal failure), but necessitatingarterial blood testing. Informed consent was obtained from all patients.The primary endpoint was to assess the agreement of themeasurements made by the Rad-57 (SpCO) and the blood levels(HbCO).Results: 50 patients were enrolled, among whom 32 were admittedfor suspected CO poisoning. Baseline demographic and clinicalcharacteristics of patients are presented in table 1. The median age was37.7 ans ± 11.8, 56% being male. Median laboratory carboxyhemoglobinlevels (HbCO) were 4.25% (95% IC 0.6-28.5) for intoxicated patientsand 1.8% (95% IC 1.0-5.3) for control patients. Only five patientspresented with HbCO levels >= 15%. The results disclose relatively faircorrelations between the SpCO levels obtained by the Rad-57 and thestandard HbCO, without any false negative results. However, theRad-57 tend to under-estimate the value of SpCO for patientsintoxicated HbCO levels >10% (fig. 1).Conclusion: Noninvasive transcutaneous measurement of bloodcarboxyhemoglobin level is easy to use. The correlation seems to becorrect for low to moderate levels (<15%). For higher values, weobserve a trend of the Rad-57 to under-estimate the HbCO levels. Apartfrom this potential limitation and a few cases of false-negative resultsdescribed in the literature, the Rad-57 may be useful for initial triageand diagnosis of CO.
Resumo:
We study the collision of a gravitational wave pulse and a soliton wave on a spatially homogeneous background. This collision is described by an exact solution of Einsteins equations in a vacuum which is generated from a nondiagonal seed by means of a soliton transformation. The effect produced by the soliton on the amplitude and polarization of the wave is considered.
Resumo:
One-dimensional arrays of nonlinear electronic circuits are shown to support propagation of pulses when operating in a locally bistable regime, provided the circuits are under the influence of a global noise. These external random fluctuations are applied to the parameter that controls the transition between bistable and monostable dynamics in the individual circuits. As a result, propagating fronts become destabilized in the presence of noise, and the system self-organizes to allow the transmission of pulses. The phenomenon is also observed in weakly coupled arrays, when propagation failure arises in the absence of noise.
Resumo:
An instrument designed to measure thermal conductivity of consolidated rocks, dry or saturated, using a transient method is presented. The instrument measures relative values of the thermal conductivity, and it needs calibration to obtain absolute values. The device can be used as heat pulse line source and as continuous heat line source. Two parameters to determine thermal conductivity are proposed: TMAX, in heat pulse line source, and SLOPE, in continuous heat line source. Its performance is better, and the operation simpler, in heat pulse line-source mode with a measuring time of 170 s and a reproducibility better than 2.5%. The sample preparation is very simple on both modes. The performance has been tested with a set of ten rocks with thermal conductivity values between 1.4 and 5.2 W m¿1 K¿1 which covers the usual range for consolidated rocks.
Resumo:
The action of individual type II DNA topoisomerases has been followed in real time by observing the elastic response of single DNA molecules to sequential strand passage events. Micromanipulation methods provide a complementary approach to biochemical studies for investigating the mechanism of DNA topoisomerases.
Resumo:
We study the collision of a gravitational wave pulse and a soliton wave on a spatially homogeneous background. This collision is described by an exact solution of Einsteins equations in a vacuum which is generated from a nondiagonal seed by means of a soliton transformation. The effect produced by the soliton on the amplitude and polarization of the wave is considered.
Resumo:
We analyze the collective behavior of a lattice model of pulse-coupled oscillators. By means of computer simulations we find the relation between the intrinsic dynamics of each member of the population and their mutual interactions that ensures, in a general context, the existence of a fully synchronized regime. This condition turns out to be the same as that obtained for the globally coupled population. When the condition is not completely satisfied we find different spatial structures. This also gives some hints about self-organized criticality.